PL - Ie - Salm y CHR - 15042024 - Rev00-Ie-02
PL - Ie - Salm y CHR - 15042024 - Rev00-Ie-02
PL - Ie - Salm y CHR - 15042024 - Rev00-Ie-02
P
BOULEVARD SALOOM
L E Y E N D A
0.40
LISTADO DE CLAVES
TD-G (EMPOTRADO, 220V,60Hz,3F)
DESCRIPCIÓN
Pinst =10.46kW
6pm-6am
ITM Riel ID4x25A
Dmax=7.32kW 3x20 30mA
C-1 3x20A 3-1x10mm2(L)+1x6mm2(T)NYY
10kA 6pm-6am ILUMINACION EXT. O PROY.
ITM Riel ID4x25A
3x20 30mA
C-2 3x20A 3-1x10mm2(L)+1x6mm2(T)NYY
10kA 6pm-6am ILUMINACION EXT. O PROY.
ITM CM Reg ITM Riel ID4x25A
3x50 3x10 30mA
C-3 3x20A 3-1x6mm2(L)+1x6mm2(T)N2XOH Tub 40mmØ PVC-P
25kA 10kA CORONA
AR CM ITM Riel ID4x25A
3x6 30mA
3-1x6mm2(L)+1x6mm2(T)N2XOH Tub 40mmØ PVC-P
BARRA DE CU, 20kA
C-4
10kA 6pm-6am BOMBA PILETA
ITM Riel ID4x25A
3-1x16mm2(L)N2XOH+1x10mm2(T)N2XOH Tub 50mmØ PVC-P
3x6 30mA
C-5 3-1x6mm2(L)+1x6mm2(T)N2XOH Tub 40mmØ PVC-P
10kA 6pm-6am ILUMINACION PILETA
ITM Riel ID4x25A
3x6 30mA
C-6 3-1x4mm2(L)+1x4mm2(T)N2XOH Tub 33mmØ PVC-P
10kA ILUMINACION CRUZ
R-2
RESERVA 3ɸ
R-3
RESERVA 3ɸ
R-4
Viene de medidor
RESERVA 3ɸ
R-5
RESERVA 3ɸ
1.00
POTENCIA PROYECTADA ES DE 9.9kW. Se deberá constatar la existencia de este suministro para TG-N caso contrario solicitar la factibilidad del mismo (gestion a cargo del contratista con el concesionario).
PROYECTO:
"REMODELACIÓN DE ESPACIO DE CIRCULACIÓN PEATONAL HORIZONTAL Y/O
VERTICAL; CONSTRUCCIÓN DE PILETA PÚBLICA; EN EL(LA) BOULEVARD
COCHRANE - SALOOM, DISTRITO CALLAO, PROVINCIA CONSTITUCIONAL DEL COD. LAMINA:
CALLAO, DEPARTAMENTO CALLAO" CON CUI Nº2640808
GG. OD SERVICIOS A LA
CIUDAD Y PROTECCION DEL
MEDIO AMBIENTE:
ESPECIALIDAD: INSTALACIONES ELECTRICAS IE-02
ABOG. SERGIO A. PAREDES PLANO: PLANO DE INSTALACIONES
PALACIOS ELECTRICAS - B. SALOOM