DISENÞO ELECTRICO LA CEIBA PLANO-Model
DISENÞO ELECTRICO LA CEIBA PLANO-Model
DISENÞO ELECTRICO LA CEIBA PLANO-Model
N
O E
HACIA
PALIN
S
AQUA PARK
GUATEMALA
O E
BAND. BAND. BAND. 3 REMATES BAND.
REMAT. 1F TANG. 1F TANG. 1F 1F REMAT. 1F
AREA VERDE
Mz S
50 LOTES
49 48 31 25 KVA
30 13 12 13m
STUB
PC 35' S
PC 30'
73
COMPLEJO
30m 36m PC 40' 34m PC 40' 40m PC 40' 42m PC 40' 36m PC 40' 36m 42m
DEPORTIVO
74 PC 30'
15m
FRATERNO VILA
1F 1/0
T 1/0
T-11
20m
T-10
20m
20m
20m
MICROPARCELAMIENTO
20m
20m
PASO PEATONAL
EL CARMEN
71 PC 30' 47 BAND. 32 29 14 11
TANG. 1F
Mz O
50 PC 30' PC 30' PC 40' PC 30' PC 30'
30m
19 LOTES PC 30'
291191 1-10 KVA
30m
30m
30m
30m
30m
PROYECTO
30m
RESIDENCIAL PC 35' CIA/53860
LA CEIBA
25 KVA BAND.
REMAT. 1F
70 30m 69 30m Mz N
29 LOTES
25 KVA
Mz L
29 LOTES
25 KVA
Mz J
27 LOTES
25 KVA
Mz H
28 LOTES
25 KVA
Mz F
28 LOTES
25 KVA
Mz D
29 LOTES
25 KVA
Mz B
12 LOTES
NOMENCLATURA AEREA
DIAGRAMA DE UBICACION PC 30' T-19 PC 40' T-17 51 T-14 46 T-9 33 T-7 28 T-4 15 T-2 10
PC 30'
68 PC 40' PC 40' PC 40' PC 40' PC 40'
AREA VERDE
T 1/0
PC 40'
BAND. BAND. BAND. BAND. BAND. BAND. POSTE EXISTENTE
PASO PEATONAL
36m
REMAT. 1F REMAT. 1F TANG. 1F REMAT. 1F REMAT. 1F REMAT. 1F
Mz P
30m
30m
30m
17 LOTES
30m
INSTALAR
POSTE NUEVO
36m
36m
Calavera intemperie
de 32 mm. (1 1/4" Ø) 50 cms o 20" de puntas
CORTACIRCUITOS 291192
para conectar 25 KVA BAND. BAND. BAND. BAND. BAND. PC 30'
SECUNDARIO NUEVO
0.20
36m
0.20 *Máximo 1.00m expuesto 1F 1/0
41m
T-16
41m
41m
REMAT. BAND.
T 1/0
AREA VERDE AREA VERDE AREA VERDE
T-1
41m
35m
35m
1F PC 45' TANG. 2F PC 45'
Medidor de KWH
Mz Q
11 LOTES 64 22m
BAND.
TANG. 1F
BAND.
D/REMATE 2F
BAND.
D/REMATE 3F T-6
BAND.
TANG. 3F
BAND.
TANG. 3F 3 2 SECUNDARIO EXISTENTE
s
38m 38m 38m 38m 41m 3-25 KVA
45m
PC 45'
S
38m PC 45' PC 45'
17 25 KVA PC 45' AREA VERDE
4.50
PC 45'
Deberá embonar 25 KVA 30m
1 PRIMARIO EXISTENTE
correctamente PC 30'
62 PC 45'
44 35 26 3F 1/0, 8 BAND. PC 45' 418604
53
3.70
PC 35' TANG. 1F
1F 1/0
BAND. 43 BAND.
ACSR
36 BAND. 25 BAND.
18 BAND. BAND.
DOBLE
REMAT.
1.70
30m
30m
42m
30m
30m
30m
30m
Mz R
11 LOTES
BAND.
PC 40' 29 LOTES
BAND.
PC 40' 29 LOTES
BAND.
PC 40' 29 LOTES
BAND.
PC 40'
29 LOTES
BAND. PC 40' 29 LOTES
BAND.
PC 40' 14 LOTES
BCO. TF NUEVO
NOTA:
*CUANDO NO ATRAVIESA LA CALLE LA ALTURA
61 41m
BAND.
REMAT. 1F REMAT. 1F TANG. 1F REMAT. 1F REMAT. 1F REMAT. 1F
ANCLA EXISTENTE
30m
30m
25 KVA
30m
30m
30m
30m
DEL GANCHO ES DE 4.50m REMAT. 1F
*CUANDO ATRAVIESA LA CALLE LA ALTURA DEL
30m
GANCHO ES DE 5.50m Mz U
5 LOTES
ANCLA NUEVA
ACOMETIDA TIPICA PC 30' PC 30'
BAND. 38 PC 30' PC 30' PC 30'
TANG. 1F 5
PC 30'
56 41 PC 40' 23 20 ANCLA BANDERA NUEVA
20m
20m
20m
20m
20m
20m
15m
59 37.5 KVA
S
1F STUB TRATAMIENTO
Mz T
AREA VERDE
AREA VERDE
37 LOTES PC 35'
25 KVA 25 KVA
PLANILLA TRANSFORMADORES
B B
T-11 T-10 #
# USUARIOS FASE CAPACIDAD
3.00 3.00
EN PLANO.-
T-20 C B B A A A - PRIMARIO NUEVO 1F 1/0, G 1/0 ACSR EN EL RESTO DEL PROYECTO.- T-4 26 A 25 KVA 120/240 V.
25 KVA - SECUNDARIO NUEVO TRIPLEX 1/0 ACSR TODO FORRADO EN TODO
T-5 24 A 25 KVA 120/240 V.
T-16 25 KVA T-1 EL PROYECTO.-
BC ABC
C C BC BC ABC
T-6 ABC - NEUTRAL NUEVO 1/0 ACSR FORRADO.- 22 A 25 KVA 120/240 V.
T-6
25 KVA A
GABARITO CALLE - TIRANTE 1/4" H. S. INDICADO EN PLANO.-
3-25 KVA - INSTALAR 3-25 KVA CSP 120/240 V. EN T-1.- T-7 26 A 25 KVA 120/240 V.
C C B
SECUNDARIA
B A A A - INSTALAR 1-25 KVA CSP 120/240 V. DE T-2 A T-12 Y DE T-14 A T-21.-
- INSTALAR 1-37.5 KVA CSP 120/240 V. EN T-13.- T-8 26 A 25 KVA 120/240 V.
1.00 8.50 1.00
- INSTALAR CORTACIRCUITOS EN POSTE #2.-
T-18 T-15 T-12 T-8 T-5 T-3 26
T-21 - HACER CONSTRUCCIONES COMO SE INDICA EN PLANO.- T-9 B 25 KVA 120/240 V.
25 KVA 25 KVA 25 KVA 25 KVA 25 KVA 25 KVA 4.25 4.25
25 KVA - INSTALAR STUB PC 25' CON ANCLA EN POSTES #
T-10 27 B 25 KVA 120/240 V.
B - INSTALAR ANCLA DE DOS OJOS UN TIRANTE EN POSTES #3, #58, #67 Y #70.-
- INSTALAR ANCLA BANDERA DE UN METRO EN EL RESTO DEL PROYECTO T-11 27 B 25 KVA 120/240 V.
COMO SE INDICA EN PLANO.-
T-13 25 KVA 120/240 V.
T-12 24 B
37.5 KVA
GABARITO BOULEVARD
PRINCIPAL T-13 37 B 37.5 KVA 120/240 V.
NOTA:
T-14 24 B 25 KVA 120/240 V.
DIAGRAMA DE FASEO DETALLE DE GABARITOS
- EN POSTES #1 SE DEBERA DEJAR SUFICIENTE CABLE Y LOS
T-15 24 B 25 KVA 120/240 V.
SIN ESCALA MATERIALES NECESARIOS PARA CONECTAR A RED DE EEGSA.-
SIN ESCALA - LA CAPACIDAD Y VOLTAJE DE LOS TRANFORMADORES TRIFASICOS
T-16 23 C 25 KVA 120/240 V.
572 PUEDEN VARIAR, DEPENDIENDO DE LAS ESPECIFICACIONES DE LA
BOMBA DE AGUA.- T-17 24 C 25 KVA 120/240 V.
RESIDENCIALES LA CEIBA
PROYECTO: