DEE Planta - Bulnes Solar - Paño E3 SE Larqui - C
DEE Planta - Bulnes Solar - Paño E3 SE Larqui - C
DEE Planta - Bulnes Solar - Paño E3 SE Larqui - C
3500 7250 2200 1550 1550 2200 DESCONECTADOR CUCHILLA VERTICAL 69 kV, APERTURA CENTRAL MOTORIZADA, SIN PUESTA A TIERRA
I NOM: 1250 A, Icc: 40 kA, BIL: 325 kV
2 1 89BT1
3600 3650 9750 3500 3200 5000 5300 1000 MARCA: ABB
CHILLÁN CHILLÁN VIEJO MODELO: SDF-72.5
PARRON 66 kV
PARRON 66 kV
ESTRUCTURA
ESTRUCTURA
SEPARADOR
ESTANQUE
ACMAFOR
ACMAFOR
INTERRUPTOR DE PODER 66 kV EN SF6, TANQUE VIVO.
VIALIDAD
CERCO
CERCO
I NOM: 2000 A, Icc: 31.5 kA, BIL: 325 kV
3 1 52BT1
MARCA: GRID SOLUTIONS
ACCESO PRINCIPAL MODELO: GL309 - F1
CERCO PERIMETRAL
LETRERO
CIRCUITO 1x66 kV HACIA TRANSFORMADOR DE POTENCIAL 72,5kV
SE LUCERO
IDENTIFICACIÓN BULNES 4 3 TPBP
69/√3 : 0.115/√3, 15VA-1x3P, 15VA-2x0.2.
TIPO BULLDOG
SUBESTACIÓN MARCA: ARTECHE
AAAC ALLIANCE (24,25 MVA) MODELO: UTD-72
5500
ɸ3 ɸ2 ɸ1 TRANSFORMADOR DE POTENCIAL 72,5kV
69/√3 : 0.115/√3, 15VA-1x3P, 15VA-1x0.2.
5 1 TPB1
MARCA: ARTECHE
MODELO: UTD-72
9100
TRANSFORMADORES DE CORRIENTE, 72.5kV
VIALIDAD INTERNA 100-200/1-1-1-1-1 A, 15VA, 3x5P20+2x0.2
5000
VIALIDAD 6 3 TCBT1
1 BULNES
MARCA: ARTECHE
MODELO: CA-72
ESC.: 1:250.000
1000
AISLADOR DE PEDESTAL POLIMÉRICO 66 kV
CERCO CERCO
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
8 18 - DISTANCIA MÍNIMA DE FUGA ≥ 1900 mm
ACMAFOR ACMAFOR
X
X BIL: 325 kV - PESO: 7,7 kg
REFERENCIA: MACLEAN NPP20XG27S
X
X
2500
X
7 7 5
X
X
CONJUNTO DE AISLACIÓN DE ANCLAJE
X
X
DISTANCIA DE FUGA 2210 mm APROX.
9.1 3 -
X
X
PARARRAYOS
2 SIMBOLOGÍA MODELO: LAPP RODURFLEX CS5-045-EB-087-A (REFERENCIAL)
5400
X
DETALLE EN PLANO: SE025R019-P-EE-01-006 - DETALLE 1
X
1900
X
CONJUNTO DE AISLACIÓN DE ANCLAJE
X
N° INDICA EQUIPO DISTANCIA DE FUGA 2210 mm APROX.
X
CANALETA
X
9.2 6 -
3 MODELO: LAPP RODURFLEX CS5-045-EB-087-A (REFERENCIAL)
X
5000 1000
X ESTANQUE DETALLE EN PLANO: SE025R019-P-EE-01-006 - DETALLE 4
9.3 9.3 9.3
X
X
ESTANQUE
N° INDICA EJE
X
AGUA-ACEITE
X
X
PAÑO B1 MODELO: LAPP RODURFLEX CS5-045-EB-087-A (REFERENCIAL)
X
X
ESTRUCTURA
4
X
PARRON 66 kV
X
X
X
10 1 T1 INCLUYE CTBC, PPRR EN MT y AT.
X
8 8 8 X X X X X
X
MARCA: WEG
ACMAFOR
X
X
5
X
ɸ1
X
BARRA
CERCO TIPO ACMAFOR
X
PRINCIPAL 66 kV
X
X X X X X
9.2 9.1 4 X X X X X
DISTANCIA DE FUGA 1900 mm APROX.
X
BARRA 66 kV
AAAC CANTON REMOVIBLE 11 3 -
PAÑO TTPP
X
MODELO: LAPP RODURFLEX CS2-040-YB-072-A (REFERENCIAL)
X
X
ɸ2 DETALLE EN PLANO: SE025R019-P-EE-01-006 - DETALLE 2
X
X
1600
X
X
X
12 1 52ET1
X
7 ɸ3 MARCA: ABB
X
1000 800
X
1800
INTERRUPTOR 2
X
DE PODER 52E1
17800
ESTRUCTURA VIALIDAD I NOM: 800 A, Icc: 25 kA, BIL: 170 kV
X
X
MARCA: ABB
1000
INTERNA
X
6000
MODELO: OVB-VBF
X
8 8
X
X
X
X
PAÑO BT1
X
9 14 2
89ET1-1 I NOM: 1250 A, Icc: 25 kA, BIL 150 kV
X
X
X
X
MODELO: GTMS-AC
X
X
X
DESCONECTADOR CUCHILLA VERTICAL 24 kV, APERTURA CENTRAL, MANDO MANUAL
X
5500
89ER-1, 89ER-2,
I NOM: 630 A, Icc: 25 kA, BIL 150 kV
X
15 6 89E1-1, 89E1-3,
MARCA: GTMS
X
X
89E2-1, 89E2,3
CERCO MODELO: GTMS-AC
X
X
VEHICULAR A PATIOS DESCONECTADOR CUCHILLA VERTICAL 24 kV, APERTURA CENTRAL, MANDO MOTORIZADO
X
X
VIALIDAD
10 VIALIDAD INTERNA
X
X
MODELO: GTMS-AC
X
X
89ETPBP-F
63000
I MÁX: 200 A, Icc: 12 kA
X
X
17 6
89ETSSAA-F DISTANCIA DE FUGA: 660 mm
X
X
650
X
X
TRANSFORMADOR DE POTENCIAL 23 kV
14,4 : 0,12 kV - 10 VA - 1x3P, 10 VA-1x0.2,.
X
X
7500
VIALIDAD INTERNA
18 3 TPEBP
MARCA: BALTEAU
3000
X
X
MODELO: VEL-24
X
X
10
X
X TRANSFORMADOR DE CORRIENTE 23 kV
ɸ3 ɸ2 ɸ1 1750 3200
X
MARCA: BALTEAU
X
TEMPERATURA
X
TRANSFORMADORES DE CORRIENTE, 23 kV
TRANSFORMADOR H3 TCE1 200-400/1-1-1-1 A, 15 VA, 2x5P20+2x0.2
X
11 x0
H1
x1 x2
H2
x3
1000
20 6
TCE2 MARCA: ABB
X
MARCA: RHONA
X
PARARRAYOS Vmáx: 25 kV
X
12200
22 6
PAÑO PRE2 MARCA: INAEL
X
TTPP 23 kV 12
14000
REFERENCIA: INZSP 2410/N
24 24 24
X
18 21 ESTACIONAMIENTOS
X
ɸ1
14 BARRA Cu EHPS Ø1-1/2" REFERENCIA: TR-208
X
17 19
23 kV
2800
17
4000
ɸ2 24 3 -
MODELO: AISLADORES GAMMA PS0250011 (REFERENCIAL)
26 13 13 13
X
ɸ3
27 15 15 15
X
GRUPO ELECTRÓGENO
BARRA TRANSFERENCIA
25 1 -
X
PILAR PARRON 23 kV
13 ɸ1
35 kVA, 380 V
X
GRUPO ELECTRÓGENO
23
X
ɸ2
23 kV
1800
X
5150
3500
ɸ3
X
30
PAÑO E3 28 PAÑO E2 20 PAÑO E1
25
X
PAÑO ER
1650
X X X X X X
BAÑO 5000
1000
1000
X
CAMARÍN
X
2500
ESTRUCTURAS 29 22 22
X
14 TTCC - PPRR 23 kV X
GRUPO
LISTADO DE EQUIPOS PROYECTADOS
X
98 98 X ELECTRÓGENO N°
2000
X X X X X X
X
CANT.
X
1575
CÁMARAS
X
X
ACCESO
1400
26 1 52E3
5850
X
CERCO
7000
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
ACMAFOR
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X MODELO: POR DEFINIR
1000
CASETA SISTEMA AGUA POTABLE DESCONECTADOR CUCHILLA VERTICAL 23 kV, APERTURA CENTRAL, MANDO MOTORIZADO
89E3-1
I NOM: 600 A, Icc: 25 kA, BIL 145 kV
27 3 89E3-2
3600
29 3 PRE3
MARCA: POR DEFINIR
66 kV 23 kV MODELO: POR DEFINIR
TRANSFORMADOR DE POTENCIAL 23 kV
CÁMARAS FOSA FOSA ENTRE FASES FASE Y TIERRA FASES FASE Y TIERRA 23/√3 : 0.115/√3 kV - 10 VA 1x3P, 10 VA-1x0.2,.
SÉPTICA SÉPTICA
30 1 TPE3
MARCA: POR DEFINIR
1450
1350
ESTRUCTURAS
ELECTRÓGENO
GRUPO
SALA DE CONTROL
PARRÓN 23 kV
PARRÓN 23 kV
TTCC - PPRR 23 kV
TTCC - PPRR 23 kV
ANTENA
VIALIDAD
DESDE PMGD
ALTURA MÍNIMA
3200 2750
PARTES ENERGIZADAS
2000 2000 1500 2500 2000 2000 2000 2000 5850 7700 3850 3100 6500 6200
ALTURA MÍNIMA DE BARRAS
6000 4000 4000 4000 4000
A G H J K L CALCULADO EN BASE A ESTANDAR IEC-61936-1
46000