IGhuagw
IGhuagw
IGhuagw
AREQUIPA - PERÚ
2020
UNIVERSIDAD NACIONAL DE SAN AGUSTÍN DE AREQUIPA
FACULTAD DE GEOLOGÍA, GEOFÍSICA Y MINAS
ESCUELA PROFESIONAL DE INGENIERÍA GEOLÓGICA
JURADOS:
PRESIDENTE: MSc. JORGE DUEÑAS RAMÍREZ
VOCAL: MSc. JUAN ANIBAL LAJO SOTO
SECRETARIA: MSc. OLGA GISELLA MARTÍNEZ RODRÍGUEZ
AREQUIPA - PERÚ
2020
CONTENIDO
DEDICATORIA ............................................................................................................. i
AGRADECIMIENTOS ................................................................................................. ii
RESUMEN .............................................................................................................. iii
ABSTRACT .............................................................................................................. iv
LISTA DE TABLAS...................................................................................................... v
LISTA DE FIGURAS .................................................................................................. vi
LISTA DE ANEXOS .................................................................................................. vii
CAPÍTULO 1
CAPÍTULO 3
CAPÍTULO 4
CAPÍTULO 5
CONCLUSIONES ..................................................................................................... 98
DEDICATORIA
AGRADECIMIENTOS
RESUMEN
ABSTRACT
This research involves the progressive development of the different stages of research,
starting from the bibliographic collection, drilling methods for hydrogeological
instrumentation, methodology for the installation of piezometers and methods of
obtaining data in the field.
LISTA DE TABLAS
LISTA DE FIGURAS
Figura 4.18 Gráficas de interpretación del sondaje PZN-16 (Huillca W., 2020) ........ 80
Figura 4.19 Gráfica de interpretación del sondaje PZN-17 (Huillca W., 2020) .......... 80
Figura 4.20 Gráficas de interpretación del sondaje PZN-18 (Huillca W., 2020) ........ 81
Figura 4.21 Gráficas de interpretación del sondaje PZN-19 (Huillca W., 2020) ........ 81
Figura 4.22 Gráficas de interpretación del sondaje PZN-20 (Huillca W., 2020) ........ 82
Figura 4.23 Gráfica de interpretación del sondaje PZN-22 (Huillca W., 2020) .......... 82
Figura 4.24 Gráfica de interpretación del sondaje PZN-23 (Huillca W., 2020) .......... 83
Figura 4.25 Gráficos de descensos de Slug en el PZN-21 (W. Huillca, 2020) .......... 85
Figura 4.26 Aproximación de curvas patrón - Slug Test en el piezómetro PZN-21
(Huillca W.,2020) ....................................................................................................... 86
Figura 5.1 Variación de la conductividad hidráulica de roca caliza en profundidad
(Huillca W., 2020) ...................................................................................................... 89
Figura 5.2 Variación de la conductividad hidráulica de las areniscas y lutitas en
profundidad (Huillca W., 2020) .................................................................................. 90
Figura 5.3 Distribución del comportamiento obtenidos mediante la ejecución de
ensayos lugeon (Huillca W., 2020) ............................................................................ 91
Figura 5.4 Distribución del comportamiento para el flujo dilatación (Huillca W., 2020)
.................................................................................................................................. 92
Figura 5.5 Distribución del comportamiento obtenidas para el flujo turbulento (Huillca
W., 2020) ................................................................................................................... 92
Figura 5.6 Medios de alta permeabilidad en piezómetros de diámetro pequeño (Huillca
W., 2020) ................................................................................................................... 93
ix
LISTA DE ANEXOS
CAPÍTULO 1
1.0 EL PROBLEMA DE INVESTIGACIÓN…...
1.1 INTRODUCCIÓN
La roca caliza por naturaleza presenta una porosidad primaria definida por la
interconexión de poros y u una porosidad secundaria relacionado a estructuras
originadas por disolución de los carbonatos, permitiendo el almacenamiento y
transmisión del agua.
Así mismo, la roca caliza, en diversos proyectos y operaciones mineras, forman parte
del sistema de rocas generadoras de yacimientos, es por ello el interés de la obtención
2
Las pruebas hidráulicas tipo Lugeon y Sug Test fueron realizados en 7 sectores
definidos en función a la disponibilidad del número de pruebas para su análisis y
estimación de la conductividad hidráulica en rocas del cretáceo como son las calizas
y areniscas/Lutitas con cierto grado de contenido de carbonatos. Estas rocas
pertenecen a las formaciones del Jumasha, Pariatambo, Pariahuanca, Santa, Carhuaz
y Farrat. Las 7 zonas se encuentran alineados en la cordillera occidental del Perú entre
los departamentos de Ancash y Lima (Sierra central). La zona 1 está ubicado en la
provincia Huari en el departamento de Ancash, la zona 2 y 3 en la provincia de
Bolognesi en el departamento de Ancash, las zonas 4, 5 y 6 se encuentra en la
provincia de Oyón en el departamento de Lima y la zona 7 ubicado en la provincia de
Yauli en el departamento de Junín. La Figura 1.1 muestra la ubicación de las zonas o
áreas donde se ejecutaron las pruebas hidráulicas tipo Lugeon y Slug Test.
200000 700000 1200000 100000 150000 200000 250000 300000 350000 400000
((
((
(
(
Ki-mc
(
COORDENADAS UTM WGS 84 Qh-c
Ki-mc
Qh-c
Pi-gd/gr Ki-c
(
ZONA DE ESTE NORTE
(
(
NQ-c N-gd/to
(
( ( ( Pi-gd/gr (
(
Ki-c
UBICACIÓN DEPARTAMENTO
((
Ci-c
ESTUDIO (m) (m)
9000000
9000000
PN-c
(
Qh-c Kis-m
(
(
(
Ki-mc
(
p
(
ZONA 1 266991 8951045Ki-mc Huari Ancash
(
(
(
(
(
NQ-c
(
COLOMBIA Kis-m
(
(
ZONA 2 273508 8904629 Bolognesi Ancash Kis-m
(
ECUADOR
((
( NQ-c
(
(
(
ZONA 3 286140 8878975 Bolognesi Ancash
(
Qh-c
Ki-mc
(
Np-v
(
PT-mzg/gr
( ((
Js-m
ZONA 4 306786 8855987 Oyón Lima
(
(
(
Ks-gd-r PeA-e/gn
(
(
ZONA 5 300370 8815062 Oyón Lima
((
N-gd/to ( Ps-c
(
Nmp-c (
(
ZONA 6 314902 8800078 Oyón Lima
(
NQ-c
( ( (
NQ-c Nmp-c Kis-m
(
( (
(
8950000
8950000
(
ZONA 7 349964 8739845 Yauli Junín (
(
(
Qpl-c
(( ((
(
NQ-c P-c
Zona 1
(
(
(
Kis-m
Ki-mc
!
(
Ks-mzgr/gdi-sr
Qh-c
. TsJi-m
(
NQ-c
9500000
9500000
(
Qpl-c Nmp-c (
(
(
Qh-c Pi-gd/gr
(
(
(
Kis-vs
(
(
(
(
NQ-c
(
(
(
(
Ki-mc
(
Kis-vs
( (
(
Qpl-c Qh-c PN-vs PN-vs
( ( (
(
Nmp-c
8900000
8900000
(
Zona 2
((
(
Qh-c
(
PN-vs P-to/gd
!
.
(
Zona 3
(
(
(
(
(
Kis-vs
!
(
.
(
Nmp-c
(
(
(
( Kis-m (
(
(
(
PN-vs BRASIL Ci-c
(
(
(
Nm-vs
Ki-mc
(
Kis-vs
(
Qpl-c
(
PeA-e/gn
(
Ki-mc
PN-c
OCEÁNO PACÍFICO
(
(
P-to/gd-pu
(
Qh-c
(
(
(
(
(
Ks-mzgr/gdi-sr PN-vs
8850000
8850000
PN-vs
(
(
Zona 4
(
( PT-mzg/gr
(
Kis-vs
!
.
(
9000000
9000000
Ps-c
(
(
(
(
(
(
(
(
Qh-c
PeA-e/gn Ki-di/gb-pt
Qpl-c Ki-di/gb-pt
(
Leyenda: Geología Regional
(
(
(
!
. PeA-e/gn
Zona 5
((
(
!
.!
. Lagunas KP-to/gd cretaceo Paleg. ton/gd Kis-mc Cretaceo inf Marino, continental !
. Qh-c
(
Kis-vs
(
Nmp-c
(
!
.
Ki-c
Qh-c Cuaternario holoceno-continental.
Ks-mzgr/
gdi-c Cretaceo sup monzogran./granodiorita Ki-m Cretaceo inf Marino
Zona 6 TsJi-m
8800000
8800000
!
.
Qpl-c
!
!
. KsP-c
(
!
.
(
Qpl-c Cuaternario pleistoceno continental KsP-c Cretaceo sup subvolcanico, continental Js-c Jurasico sup continental
(
Ki-mc
(
(
(
Ps-c
(
Domos Ks-an Cretaceo sup subvolcanico Lurin JsKi-vs Jurasico sup cretaceo inf volc-sed
P-to/gd-pu
(
!
.
(
Kis-vs Np-v
(
N-an/ri Neogeno,andesita- riolitia. Ks-gd-r Superunidad Rancap Js-m Jurasico sup marino (
Qpl-c Lagunas PeA-e/gn
Qpl-c
((
(
Ks-di/to/ TsJi-m
N-gd/to Neogeno,granodirita-tonalita. gd-h Superunidad humaya TriasicoSup,Jurasico inf.marino
Qpl-c
(
( ( Qh-c
(
(
Ks-di/to/ Ks-gd/to-pa PN-vs
O-ms PN-mgr/gr Stockcs de la region Andina. Superunidad La Mina PT-mzg/gr Permico, plutones tardihercinico
gd-lm Kis-vs
((
(
Ks-mzgr/
Paleozoico-tonalita/granodiorita. Superunidad Aynaca PT-to/gd Permico,Plutones Tardihercinicos
(
P-to/gd-sy gdi-ay
8750000
8750000
Qpl-c (
Kis-vs
(
8500000
8500000
P-to/gd-pu pluton Puscao Ks-gd/to-p Superunidad Paccho Ps-c Permico sup. continental Kis-m
(
TsJi-m
E-ms Ks-mzgr/gdi-sr
(
Ks-mzg/
P-to/gd Tonalita y granodio. paleogensa gdi-sr Superunidad Santa Rosa Pis-mc Permico, sup-inf marino, continental PN-vs (
Qh-c (
(
O-ms
P-to/gd-po Paleogeno, tonalita Ks-gd/to-pa Superunidad Pampahuasi CsP-m Carbonifero sup-permico
Kis-vs
Zona 7
OCEÁNO PACÍFICO Ks-mzgr/ !
!
. Kis-m (
(
P-to/gd-sj Pluton San Jeronimo Superunidad tiabaya Ci-c Carbonifero inferior, continental
gdi-t
Nmp-v
Nm-v Ks-mzgr/
NQ-c Neogeno cuaternario-continental Cretaceo inf microgran./granodio. D-m Devonico marino Ks-gd/to-pa
(
gd-par
BOLIVIA
(
Np-v Neogeno plioceno-volcanico Ki-mzgr/gd Cretaceo inf monzogran./granodio. Dc-mzg/gr Devonico, plutones Ki-m
8700000
8700000
Ps-c
(
Kis-vs
(
Kis-m
Nm-v Neogeno mioceno-volcanico Ki-di/gb-bt diorita gabrodiorita SD-ms Silurico- devonico, metased Nm-vs (
Kis-vs ( ((
Nmp-v Neogeno mioceno plioceno-volcanico. Ki-di/gb Superunidad Patap O-ms Ordovicico- metased.
(
Ks-mzgr/gdi-sr (
Qpl KsP-c
Nm-vs Neogeno mioceno, volc-sedimentario Ki-to/ di-i Superunidad Ilo Pi-gd/gr Paleozóico inf. granod-granito JsKi-vs
(
Qpl
PN-vs Paleogeno Neogeno,Volc.Sed. Kis-vs Cretaceo superior inferior,volc-sed. PeA/gn Precambrico neoproterozoico Nm-vs
(
10 5 0 10 20 30 Kis-m
PN-c Paleogeno neogeno cont. Ki-c Cretaceo inferior continental PeA-e/gn Precambrico
Kis-vs
(
Kis-m
KILÓMETROS (
P-c Paleoceno continental Kis-m Cretaceo inf sup marino Nm-vs
1:1,500,000 (
(
200000 700000 1200000 100000 150000 200000 250000 300000 350000 400000
DIBUJADO POR: PLANO Nº:
UNIVERSIDAD NACIONAL DE SAN AGUSTÍN DE
0 37.5 75 150 225 300 W. Huillca Aguilar AREQUIPA
1.1
FECHA: FACULTAD DE GEOLOGÌA, GEOFÍSICA Y MINAS
ESCUELA PROFESIONAL DE INGENIERÍA GEOLOGÍCA
KILÓMETROS Setiembre 2020
1:8,000,000 ESCALA:
Indicada UBICACIÓN DE ZONAS DE EJECUCIÒN
PROYECCIÓN: UTM DE PRUEBAS HIDRÁULICAS
DATUM: WGS 84 Z ONA:17S, 18S, 19 S
4
1.7 HIPÓTESIS
Si se realiza una prueba hidráulica tipo Lugeon y Slug test, siguiendo la metodología
adecuada, entonces se obtendrá valores de conductividad hidráulica más
representativos al medio ensayado.
• XA = Tipo de relleno.
• XB = Abertura de discontinuidades.
• XC = Frecuencia de fracturas.
1.8.3 INDICADORES
• Granulometría de relleno.
• Grado de fracturación.
• Grado de disolución.
• Persistencia de las fracturas.
• Espesor de abertura.
• Profundidad de prueba.
1.9.1 ALCANCES
1.9.2 LIMITACIONES
CAPÍTULO 2
2.0 MARCO TEÓRICO……
2.1 INTRODUCCIÓN
El Ciclo Hidrogeológico describe el movimiento del agua, pasando por todas sus fases.
Debido a su denominación como ciclo, esta no presenta un principio ni un final. Lo
más intuitivo, es considerar una primera fase del agua que precipita, el vapor de agua
contenido en la atmósfera se condensa alrededor de las partículas, y por el peso cae
y se desplaza de la atmósfera a la superficie terrestre. Durante este trayecto el agua
precipitada puede seguir diferentes caminos (FICHS, 2009):
• •Puede caer sobre la superficie terrestre. En este caso, una parte del agua
continuará circulando en superficie (escorrentía superficial), dando origen a
torrentes, ríos y lagos.
• •Pero otra parte empezará a rellenar los poros del subsuelo, dando origen a la
infiltración a una velocidad que dependerá de la porosidad del terreno
(disposición y tamaño de los huecos entre los granos que componen el terreno),
de su grado de humedad. De esta agua infiltrada, una parte circulará por la
zona más superficial (escorrentía subsuperficial o hipodérmica) pudiendo
aflorar en superficie durante su circulación y dando lugar a manantiales
(afloramientos).
La parte restante del agua infiltrada, seguirá descendiendo por gravedad y llegará a
la zona saturada del subsuelo, pasando a formar parte de las aguas subterráneas
(escorrentía subterránea). La Figura 2.1 muestra un esquema de funcionamiento
hidrodinámico.
La definición de la palabra “Acuífero” proviene del vocablo latín “aqua” que significa
“agua” y “fero” que equivale a “llevar”.
Formación geológica que contiene agua en cantidades apreciables y que permite que
circule a través de ella con facilidad.
• Acuíferos libres, Son aquellos en los que el límite de la zona saturada queda
definido por la superficie freática, ésta varía su posición ascendiendo y
descendiendo, respondiendo a la recarga y descarga del acuífero.
• Capa Confinante: unidad hidrogeológica que actúa como una barrera para
el flujo o como sello para un acuífero.
13
k=k0
Dónde:
K = conductividad hidráulica
K0 = permeabilidad intrínseca, específica, geométrica o coeficiente de
permeabilidad del terreno
= densidad o masa específica
g = aceleración de la gravedad
µ = viscosidad dinámica del fluido
La prueba de Lugeon (Packer test), puede ser usado dependiendo del detalle de la
información requerida.
/
= ln
2 (∆ℎ)
Dónde:
: Conductividad Hidráulica
Q: Caudal de entrada
L: Tramo de ensayo,
Δh: Carga hidráulica causado por la inyección de agua
R: radio de influencia, distancia a la cual las condiciones iniciales del nivel de
agua no cambian debido a la inyección de agua.
: Radio del sondaje.
/
= 1.12 ∗
∆ℎ
/ 0)
&'() *+ , +)- = .. .
0
Dónde:
ln 23 5
1= 4
2 06
Dónde:
20
1, transmisividad (m2/día)
, caudal de inyección (m3/día)
, radio de influencia (m)
, radio de perforación (m), y
06, presión de inyección neta (m)
06 = 0 + ℎ + ℎ8 − ℎ:
Dónde:
Las consideraciones, para la realización de una prueba hidráulica tipo Lugeon, son:
ensayo al punto medio. Es decir, la presión no debe de exceder 1 psi por pie
(0.3048 m) de profundidad.
• La prueba debe ser realizado, en un medio rocoso y tramo saturado
(Hidrogeología).
• Cada prueba en cada presión o estadio, debe ser continua, hasta alcanzar la
condición estacionaria.
llegar a la Pmáx., una vez que se alcance la Pmáx, las presiones disminuyen,
siguiendo las mismas etapas de presión utilizadas en los estadios anteriores (ver
Tabla 2.3).
Una práctica usual de interpretación de las pruebas de Lugeon, se basa en los trabajos
realizados por Houlsby (1976), quien propuso que se seleccionen valores de
conductividad hidráulica representativos basados en el comportamiento de los valores
de Lugeon, calculados para cada etapa de presión.
De forma resumida, la Tabla 2.4 resume los 5 comportamientos típicos propuestos por
Houlsby en 1976.
23
1 0
Ψ= .
. 0)
Factor de presión adimensional.
Dónde:
0), Presión de referencia igual a 1MPa o 145 psi=10 bares.
0, Presión de agua inyectada en cada etapa.
. , factor de conversión, valor de 1 cuando se utiliza unidades en el SI (q=l/min,
L=m y P =MPa) y valores de 12.42 cuando se utiliza valores en sistema Ingles
(q=gal/min, L=pies y P=psi.
El conjunto de valores de Lugeon (Lu) correspondiente a las cinco (05) etapas de una
prueba, se grafican en un diagrama bidimensional entre q/L vs ᴪ, donde se observa
la relación de las presiones. La forma del ciclo, describe el comportamiento de los
valores de Lugeon a medida que se desarrolla la prueba.
Al igual que el comportamiento de cada una de las 5 categorías descritas por Houlsby
(1976), propuso la interpretación de los ensayos de Lugeon, haciendo uso de los
25
Hvorslev (1951), desarrollo una relación empírica que describe la respuesta del nivel
de agua, en un acuífero confinado (también aplicable a acuíferos libres) ocasionado
por la inyección o extracción instantánea de agua, de un pozo, expresado por la
ecuación:
28
Dónde:
(1984). Asimismo, Cooper et.al, desarrolló un método de curvas tipo para las pruebas
Slug, este método no requiere de bombeo o pozos de observación. La inyección
instantánea de un volumen conocido (V), en un pozo de diámetro 2rw, provoca un
ascenso del nivel del agua (h0) en el pozo, es expresado por la ecuación:
&
ℎS = Y
X
ℎZ
= [(., \)
ℎS
Y
]
.= Y
X
1I
\= Y
X
Dónde:
T= transmisividad
S= coeficiente de almacenamiento
F= función integral que depende de las fórmulas de Bessel de orden 0 y 1.
rw= radio del pozo
rc= radio de la tubería de acceso
t= tiempo
La Figura 2.9 representa las curvas tipo propuesta por Cooper (1967), que
posteriormente fue cuestionado y validado por Bredehoeft and Papadopulos (1980)
para la estimación de propiedades hidráulicas de pruebas Slug en rocas cristalinas de
baja conductividad hidráulica.
30
Figura 2.9 Curvas tipo de interpretación ensayos slug, propuesta por Cooper.
Dónde:
h, transformación Laplace de h (L)
H0, desplazamiento inicial en el pozo (L)
K1, función de Bessel del segundo grado, orden 1
p, variable de transformación de Laplace
rc, radio del casing (piezómetros)
rw, radio del pozo (Sondaje)
S, Almacenamiento
t, tiempo
T, transmisividad.
31
Figura 2.11 Representación gráfica propuesta por Bouwer - Rice (1976), para
acuíferos confinados.
Hyder et.al (1994) desarrollo un modelo transitorio completo, conocido como KGS
Model, para interpretar pruebas Slug en acuíferos confinados, para pozos que
33
penetran total o parcialmente. La solución simula la respuesta del nivel del agua del
pozo de prueba y pozos de observación, e incluye una zona denominado “piel” de
espesor finito que envuelve el pozo de prueba (ver Figura 2.12).
Figura 2.12 Esquema representativo del KGS Model (Hyder et. al. 1994)
Butler y Zhan (2004) integran una solución analítica para pruebas Slug en pozos total
o parcialmente penetrantes, en acuíferos confinados de alta conductividad hidráulica
que presenta pérdida por fricción en pozos de pequeño diámetro y efectos estáticos
en el pozo de prueba y pozos de observación de gran diámetro. La solución de Butler-
Zhan, permite analizar datos de comportamiento oscilatorio, de pruebas Slug en uno
o varios pozos.
34
Dónde:
b, longitud del filtro del pozo
L, longitud teórica de columna de agua (Zurbuchen et.al, 2002).
l, longitud de columna de agua por debajo del filtro del pozo
rc, radio del casing o entubado
rw, radio del pozo
Barker y Black (1983) propusieron una solución analítica para las pruebas Slug test,
en piezómetro totalmente penetrantes en medios fracturados, asumiendo una doble
porosidad con bloques de matriz en forma de losa y cúbica.
fractura
Matrix
Es importante también analizar el origen de los depósitos (fluvial, eólico, coluvial, etc.),
los ambientes sedimentarios y su edad. En cuanto a este último parámetro debemos
37
considerar de interés principalmente los depósitos del Terciario y Cuaternario, que son
los menos consolidados y en consecuencia más porosos y permeables.
Una formación geológica que rendirá cantidades significativas de agua puede ser
definida como acuífero. Un requerimiento principal, es su capacidad de almacenar
agua en la porosidad de la roca, la porosidad puede ser procedente del espacio
intergranular o de fracturas.
Las características de una fractura más relevante para fines de hidrogeología son:
orientación, abertura, persistencia (continuidad), relleno, rugosidad y condición
hidrogeológica (agua). Estas características dependen de la resistencia ofrecida por
la roca a la fuerza externas. Quiere decir, en rocas duras las fracturas son extensas,
grandes y densificadas en comparación con aquellas rocas más blandas, que son de
extensión limitada, relativamente pequeñas y de baja densificación.
Las fracturas (a menos que se llenen con material cementante) facilitan el flujo de
agua a través de la roca. Además, en comparación con un medio poroso, un medio
fracturado ofrece relativamente menos resistencia al movimiento del agua porque las
moléculas de agua no están sujetas a barreras dentro de la fractura. Es lógico decir
que, cuanto más largas son las fracturas y más suave es su pared, más fácilmente se
transmite el agua. Debido a que las fracturas dominan el movimiento de aguas
subterráneas, es necesario realizar un reconocimiento del entorno geológico-
estructural, en estudios de hidrogeología e hidrología, así como en ingeniería
hidráulica.
38
secas, las fracturas están saturadas con carbonato por lo que esta zona no tiene
fracturas abiertas. Sin embargo, el nivel base cambia a lo largo del tiempo geológico.
Es característico a partir de las cavidades de la disolución terminan ya sea como
manantiales de flujo libre o como salidas ocultas bajo el Cuaternario superficial y
sedimentos terciarios o cuerpos de agua superficiales como lagos, ríos y mares.
La fluctuación del nivel del agua en el sumidero indica recarga y descarga a las
formaciones kársticas. Las formaciones kársticas están completamente desarrolladas
en las regiones húmedas y semiáridas donde los lagos generalmente están
interconectados con la red subyacente de solución-cavidad.
La disolución de los carbonatos de calcio por el agua hace que las aguas subterráneas
importantes se encuentren acuíferos en roca caliza. Además, al disolverse la roca,
esta tiende a aumentar su porosidad y permeabilidad con el tiempo. El desarrollo de
la disolución de roca caliza en un terreno kárstico se caracteriza por la presencia de
canales de solución y drenajes subterráneos a través de sumideros y cavernas. Tales
zonas contienen por lo general grandes cantidades de agua subterránea.
2.7.2.1 CALIZAS
a) Karst
El término Karst es usado para describir formas particulares de paisaje con cavernas
y sistemas extensos de agua subterránea que se desarrollan en rocas solubles como
calizas, mármol y yeso. La meteorización producto de los procesos fluviales y
glaciares juega un rol importante y crucial para el desarrollo de Karst. El desarrollo
completo de Karst es alcanzado en zonas donde la roca caliza es relativamente pura
(con más del 80% de Ca CO3), capas potentes, mecánicamente dura y presentan
discontinuidades para que el flujo de agua se concentre a lo largo de las
discontinuidades en lugar de pasar a través de la masa rocosa. Es así que, el resultado
de procesos de meteorización química de las rocas carbonatadas, fundamentalmente
roca caliza, presentes en una determinada zona de estudio da lugar a rasgos Kársticos
que pueden ser evidenciados en superficie. El desarrollo de karst puede ser
diferenciado en 3 grandes grupos de acuerdo a la escala de las formas. (1) Pequeña
escala referida a formas de dimensiones comúnmente < a 10 m, (2) a mediana escala
con dimensiones en el rango de 10 a 1000 m y (3) a gran escala donde las
dimensiones son mayores a 1000 m.
Figura 2.17 Seis principales tipos de Dolinas A.C. Williams y P.G. Fookes, 2003.
42
Las 07 zonas de estudio dentro del marco regional están ubicadas principalmente en
una secuencia sedimentaria-carbonatada identificada como la Formación Jumasha,
Fm. Pariatambo, Fm. Chúlec, Fm. Pariahunca, y Grupo Goyllarisquizga.
La Formación Farrat (Ki-fa) está compuesta por areniscas blancas friable de grano
medio y limolitas rojizas. Se considera que la formación Farrat fue depositada durante
el Aptiense cuyo espesor se estima en 20 m.
La Formación Santa (Ki-sa) está compuesta por calizas de color gris azulado, aparece
suprayaciendo a la formación Chimú (secuencia concordante). Se le estima un
espesor de 100 a 180 m. Su edad es del Valangiense Superior.
CAPÍTULO 3
3.0 MEDOTOLOGÍA DE ESTUDIO Y ADQUISICIÓN DE DATOS IN SITU…….
3.1 INTRODUCCIÓN
3.2 ANTECEDENTES
a) Perforación diamantina
Dentro de la tubería de perforación hay otro tubo interno (tubo interior) que contiene
un mecanismo de cierre conectado a un cable de acero. Al final de cada serie de 1.5
m, el cable se utiliza para izar el tubo que contiene el testigo de roca a la superficie, el
testigo se almacena en cajas especiales que contienen compartimientos para el
testigo (Ver Figura 3.1).
48
Figura 3.1 Cabezal para recuperación de testigo - tubo Interior (MBI Drilling
Products, 2020)
Las Figura 3.3 y Figura 3.4 muestran las máquinas de perforación que fueron
utilizadas para la instrumentación de piezómetros tipo Casagrande.
Así mismo, La Figura 3.8 presenta un ejemplo del diseño constructivo de piezómetros
tipo Casagrande.
Las pruebas Lugeon (LU) son pruebas de inyección a carga constante que se llevan
a cabo bajo condiciones de régimen permanente para 3 diferentes presiones de
inyección (25%, 50% y 75% de presión máxima). Las presiones son incrementadas
para sucesivas pruebas hasta alcanzar el valor máximo y luego reducida para repetir
las pruebas para las dos presiones más bajas (total 5 pruebas o estadios). El flujo es
medido a intervalos de 1 minuto utilizándose la tasa de flujo promedio de los valores
estables para determinar la conductividad hidráulica. Asimismo, en la Figura 3.9 se
muestra la ejecución de ensayo, como; el inflado del packer neumático con la presión
adecuada y las lecturas de consumo durante el ensayo.
• Para dar inicio a la prueba de Lugeon, el sondaje debe ser lavado con agua
limpia a presión (sin presencia de partículas sólidas suspendidas u otra
sustancia presente). Con la finalidad de limpiar los sólidos presentes en el
sondaje, generados por efecto del proceso de perforación (lama de
perforación), la cual podrían llevarnos a datos erróneos de permeabilidad.
• Elección del tramo de ensayo, de manera rápida se deberá de evaluar las cajas
portatestigos (cores) para identificar un tramo competente para la instalación
del Packer. La Figura 3.10 muestra un tramo adecuado para obturar.
• En hidrogeología, para una mejor representatividad de parámetros hidráulicos,
es recomendable realizar pruebas tipo Lugeon con longitud libre de ensayo
entre 5 y 25 metros.
57
0 = 0.9 ∗ _+ ∗ ` − (ℎ + O1a)
Dónde:
Pg, presión Manométrica (m).
Ge, gravedad específica de la roca (2.5 - 2.7).
Z, profundidad al punto medio del tramo de prueba (m).
hg, altura del manómetro sobre la superficie (m).
DTW, profundidad del nivel freático o profundidad al punto medio de la prueba
(m).
La Figura 3.11 muestra un ejemplo de las presiones utilizadas para 5 estadio de una
prueba tipo Lugeon y la perdida de flujo (l/min/m) en función del cambio de presión
b
(bc, presión de agua inyectada/presión de referencia).
Para la ejecución y registro de datos de los ensayos Slug Test se utilizaron los
siguientes equipos, herramientas y materiales:
• Laptop
• Sensores de presión Diver y/o Level troll
• Cable de transmisión USB.
• Barra de 1.50 m de longitud y 0.038 m de diámetro.
• Cronómetro.
• Flexómetro de 5.00 m.
• Wincha y plomada para medir la profundidad del piezómetro.
• Sonda eléctrica WLM (Water Level Meter, marca Solinst).
• Libreta de campo y lapicero.
• Cable acerado para descenso de la barra.
En la Figura 3.12 se muestra los elementos para la ejecución de ensayo al slug test.
Mediante la prueba de Slug se logra ejecutar dos ensayos (al sumergir la barra y al
retiro de la barra), la cual serán denominados como Slug Descenso y Slug
Recuperación para diferenciarlos durante el proceso de interpretación. La Figura 3.13
muestra el registro del ensayo slug test mediante un sensor de presión durante el
descenso y recuperación del nivel de agua a diferentes tiempos.
Figura 3.12 Elementos para la realización de un Slug Test (Huillca W., 2020)
62
En la Figura 3.14 se muestra el formato de los datos que deben ser registrados durante
el desarrollo de una prueba tipo Lugeon y se presenta el registro de datos de la prueba
de Lugeon ejecutado en el sondaje PZN-01 (color azul).
Figura 3.14 Datos de prueba Tipo Lugeon en el Sondaje PZ-01 (Huillca W.,
2020)
Los ensayos de barra “Slug Test” requieren de cuidado cuando se dispone a realizar
un cambio instantáneo del nivel de agua. En la Figura 3.15 muestra el registro para la
ejecución de los dos ensayos (Slug de descenso y recuperación para diferentes
tiempos) y la información necesaria requerida de campo.
64
CAPÍTULO 4
4.0 ANÁLISIS E INTERPRETACIÓN DE PRUEBAS HIDRÁULICAS
4.1 INTRODUCCIÓN
Para la representación y análisis de los ensayos tipo Lugeon, pruebas que son
desarrolladas durante el proceso de las actividades de perforación (en sondaje), se
realizaron ensayos en macizo rocoso a diferentes profundidades. Para la presente
tesis se ha considerado 62 pruebas tipo Lugeon ejecutados en roca caliza, distribuidos
en 21 sondajes.
66
Se realizó un ensayo tipo Lugeon hasta la profundidad de avance (20.0 m). Para ello
se registró la profundidad de avance de perforación, profundidad del nivel de agua y
se evaluó los testigos del sondaje para la adecuada ubicación, instalación y obturación
del Packer (14.10-15.00 m). Considerando la secuencia y cuidados descritos en la
sección 3.3.1.
Los datos iniciales para la realización de ensayo tipo Lugeon en el sondaje PZN-03 se
muestran en la Tabla 4.1.
Figura 4.1 Elección del ensayo lugeon en el software Aquifer Test (Huillca W.,
2020)
69
.
70
Figura 4.2 Ingreso de datos iniciales al Aquifer Test (Huillca W., 2020)
71
Figura 4.3 Ingreso de datos y análisis de resultado de pruebas Lugeon mediante software aquifer test (Huillca W.,
2020)
72
a) Zona 1
En esta zona se encuentra el punto de evaluación PZN-01 compuesta por roca caliza.
b) Zona 2
Figura 4.5 Gráficas de interpretación del sondaje PZN-02 (Huillca W., 2020)
Figura 4.6 Gráficas de interpretación del sondaje PZN-03 (Huillca W., 2020)
74
c) Zona 3
En esta zona se encuentran los puntos de evaluación PZN-04 y PZN-05 los cuales
están distribuidas en roca caliza.
Figura 4.7 Gráficas para interpretación sondaje PZN-04 (Huillca W., 2020)
Figura 4.8 Gráfica de interpretación del sondaje PZN-05 (Huillca W., 2020)
d) Zona 4
Esta zona se encuentra conformado por 03 puntos de análisis PZN-06, PZN-07 y PZN-
08 representados por roca caliza.
rocoso presenta comportamiento de dilatación (02 pruebas) y laminar (01 prueba) con
permeabilidades entre de 2.40x10-2 m/día a 3.84x10-3 m/día. Ver (Figura 4.9).
Figura 4.9 Gráficas de interpretación del sondaje PZN-06 (Huillca W., 2020)
Figura 4.10 Gráficas de interpretación del sondaje PZN-07 (Huillca W., 2020)
76
e) Zona 5
Figura 4.11 Gráficas de interpretación del sondaje PZN-08 (Huillca W., 2020)
Figura 4.12 Gráfica de interpretación del sondaje PZN-10 (Huillca W., 2020)
Figura 4.13 Gráficas de interpretación del sondaje PZN-11 (Huillca W., 2020)
Figura 4.14 Gráficas de interpretación del sondaje PZN-12 (Huillca W., 2020)
78
Figura 4.15 Gráficas de interpretación del sondaje PZN-13 (Huillca W., 2020)
79
Figura 4.16 Gráficas de interpretación del sondaje PZN-14 (Huillca W., 2020)
Figura 4.17 Gráficas de interpretación del sondaje PZN-15 (Huillca W., 2020)
80
Figura 4.18 Gráficas de interpretación del sondaje PZN-16 (Huillca W., 2020)
f) Zona 6
En esta zona se ejecutaron ensayos en los sondajes PZN-17, PZN-18, PZN-19 y PZN-
20 en macizo roca entre caliza, arenisca y lutita.
Figura 4.19 Gráfica de interpretación del sondaje PZN-17 (Huillca W., 2020)
81
Figura 4.20 Gráficas de interpretación del sondaje PZN-18 (Huillca W., 2020)
Figura 4.21 Gráficas de interpretación del sondaje PZN-19 (Huillca W., 2020)
Figura 4.22 Gráficas de interpretación del sondaje PZN-20 (Huillca W., 2020)
g) Zona 7
Esta zona se encuentra conformado por 03 puntos de análisis PZN-22, PZN-23 y PZN-
24 representados por roca caliza.
Figura 4.23 Gráfica de interpretación del sondaje PZN-22 (Huillca W., 2020)
83
Figura 4.24 Gráfica de interpretación del sondaje PZN-23 (Huillca W., 2020)
Las pruebas Slug consistieron en la variación instantánea del nivel de agua inicial
mediante la introducción de un pulso instantáneo, que involucra un cambio rápido en
la posición del nivel estático en el piezómetro ensayado (h0). Este pulso fue generado
por una barra (Slug) de dimensiones de 1.50 m de longitud y 0.038 m de diámetro.
Después de originado el pulso, inmediatamente se registraron las variaciones del nivel
de agua para diferentes tiempos (s), hasta llegar nuevamente a las condiciones
estáticas iniciales, permitiéndonos estimar la conductividad hidráulica horizontal local
del material en el entorno del tramo de ensayo (Filtro) (L).
Curva de
Curva de
aproximación
aproximación
Descenso
medido
Descenso
medido
Así como, la elección de la solución por la cual optamos (KGS model) también se
puede analizar utilizando curvas de aproximación propuesta por otros autores
(Hvorslev, Butler-Zhan, Barker-Black), considerando criterios del medio ensayado.
Para contraste de aproximación y estimación de parámetros hidráulicos se ha utilizado
como mínimo una solución adicional.
La Tabla 4.10 muestra el resumen de los resultados obtenidos de los Slug Test
realizados en piezómetros Casagrande. Asimismo, las gráficas resultantes de los 20
ensayos Slug Test ejecutados se detalla en el anexo A.2.
87
CAPÍTULO 5
5.0 DISCUSIÓN DE RESULTADOS.
5.1 INTRODUCCIÓN
Así mismo, puede apreciarse que las calizas de la formación Pariatambo presenta
permeabilidades más bajas en comparación con las demás, con un rango entre
1.91x10-2 y 1.12x10-4 m/día, seguido por las calizas de la formación Santa (entre
6.60x10-2 y 6.93x10-4 m/día).
El rango de valores de conductividad hidráulica para las calizas, según B.B.S. Singhal,
R.P. Gupta mostrado en el apartado 2.5.1 se clasifican como rocas de permeabilidad
moderadas a bajas.
90
Otro grupo de rocas evaluadas como parte del presente fueron las constituidas por
areniscas, lutitas y/o intercalación de estas. Fueron elegidas ya que presentan
carbonatos en su matriz, resultado del tipo de proceso de sedimentación y formación
de roca (sedimentos marinos del cretáceo). La Figura 5.2 presenta la variación de la
conductividad hidráulica de rocas de composición de areniscas y lutitas en
profundidad, se observan valores de conductividad hidráulica que varían entre 1m/día
y 10-3 m/día. Los valores altos están principalmente asociadas a zonas con el grado
de densidad de fracturas, tipo de relleno y abertura de las discontinuidades.
Del 40% de comportamiento tipo Dilatación Figura 5.4, el 72% corresponde a ensayos
ejecutados en calizas y el 28% a rocas de intercalaciones de areniscas y lutitas. Esto
quiere decir, que se ha ocasionado una dilatación o abertura temporal de las fracturas
del macizo rocoso (principalmente en Calizas) durante el desarrollo del ensayo.
92
Figura 5.4 Distribución del comportamiento para el flujo dilatación (Huillca W.,
2020)
Así mismo, la Figura 5.5 muestra que, del 25% correspondiente a comportamiento de
Flujo Turbulento, el 69% fueron resultado de los ensayos ejecutados en
areniscas/lutitas y el 31% en calizas. Esto significa que, las discontinuidades del
macizo rocoso se encuentran parcial o moderadamente abiertas.
Prof.
Zona de Código de Tipo de Conductividad Formación Grado de
Promedio de Litología
Estudio Perforación Ensayo Hidraúlica (m/día) Geológica Fracturación
Ensayo (m)
Prof.
Zona de Código de Tipo de Conductividad Formación Grado de
Promedio de Litología
Estudio Perforación Ensayo Hidraúlica (m/día) Geológica Fracturación
Ensayo (m)
Prof.
Zona de Código de Tipo de Conductividad Formación Grado de
Promedio de Litología
Estudio Perforación Ensayo Hidraúlica (m/día) Geológica Fracturación
Ensayo (m)
Prof.
Zona de Código de Tipo de Conductividad Formación Grado de
Promedio de Litología
Estudio Perforación Ensayo Hidraúlica (m/día) Geológica Fracturación
Ensayo (m)
CONCLUSIONES
el centro y norte del Perú, la cual puede ser utilizada como partida para
evaluaciones futuras.
3 Haciendo uso de los Software Aqtesolv (para Slug Test) y Aquifer Test (para
pruebas Lugeon), los métodos analíticos utilizados para el análisis y estimación
de la conductividad hidráulica que representaron mejor ajuste y
representatividad de los valores de permeabilidad fueron las curvas propuesta
por KGS Model (1994), Barker-Black (1983), Butler-Zhan (2004) y Hvrslev
(1951) y Houlsby (1976).
RECOMENDACIONES
REFERENCIAS BIBLIOGRÁFICAS
BARKER, J.A., 1988. A generalized radial flow model for hydraulic tests in fractured
rock, Water Resources Research, vol. 24, no. 10, pp. 1796-1804.
FETTER, JR. (2014) Applied Hydrogeology. (4ta. ed.). United State of America:
Pearson New International.
GONZALES DE VALLEJO, L., FERRER M., ORTUÑO L.& OTEO C. (2002). Ingeniería
geológica. Madrid: Pearson Educación.
TODD, D., LARRY, W. (1980). Groundwater Hydrology (3ra. ed.). United States of
America: John Wiley & Sons, Inc.
Number: -----
Client: -----
Lithology: Caliza
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-5 -2
1 30.0 0.00500 0.00460 0.00500 0.00480 0.00500 0.00510 0.00520 0.00530 0.00530 0.00510 0.00504 2.4339829 × 10 2.103 × 10 1.9
-5 -2
2 45.0 0.01770 0.01800 0.01750 0.01800 0.01800 0.01800 0.01800 0.01800 0.01830 0.01830 0.01798 6.8719245 × 10 5.937 × 10 5.3
-4 -1
3 60.0 0.05400 0.05400 0.05400 0.05400 0.05400 0.05400 0.05500 0.05600 0.05500 0.05400 0.05440 1.7203179 × 10 1.486 × 10 13.4
-5 -2
4 45.0 0.02040 0.02020 0.02180 0.02040 0.02090 0.02070 0.02040 0.02060 0.02040 0.02050 0.02063 7.8847499 × 10 6.812 × 10 6.1
-5 -2
5 30.0 0.00500 0.00450 0.00500 0.00460 0.00500 0.00500 0.00500 0.00500 0.00500 0.00500 0.00491 2.3712016 × 10 2.049 × 10 1.8
-5 -2
Average 7.3530076 × 10 6.353 × 10 5.7
0.075
1 0.06 1
Flow [m³/min]
2 2
0.045
Step
Step
3 3
0.03
4 4
5 0.015 5
0
0 20 40 60 80 0 20 40 60 80 0 3 6 9 12 15
Pressure [psi] Pressure [psi] Lugeons
Dilation
Lugeon: 1.9
Hydraulic Conductivity: 2.4339829E-5 cm/s
Hydraulic Conductivity: 2.103E-2 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Lithology: Caliza
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-6 -3
1 6.0 0.00090 0.00080 0.00080 0.00080 0.00080 0.00080 0.00080 0.00080 0.00080 0.00510 0.00124 3.8442357 × 10 3.321 × 10 0.3
-6 -3
2 12.0 0.00120 0.00120 0.00130 0.00120 0.00130 0.00120 0.00120 0.00120 0.00130 0.01830 0.00294 8.4959970 × 10 7.341 × 10 0.6
-5 -2
3 18.0 0.00120 0.00110 0.00120 0.00120 0.00120 0.00120 0.00120 0.00120 0.00120 0.05400 0.00647 1.7508738 × 10 1.513 × 10 1.3
-6 -3
4 12.0 0.00110 0.00100 0.00100 0.00100 0.00100 0.00100 0.00100 0.00100 0.00100 0.02050 0.00296 8.5537929 × 10 7.390 × 10 0.7
-6 -3
5 6.0 0.00070 0.00060 0.00060 0.00060 0.00060 0.00060 0.00060 0.00060 0.00060 0.00850 0.00140 4.3402661 × 10 3.750 × 10 0.3
-6 -3
Average 8.5486060 × 10 7.386 × 10 0.7
0.0075
1 0.006 1
Flow [m³/min]
2 2
0.0045
Step
Step
3 3
0.003
4 4
5 0.0015 5
0
0 5 10 15 20 0 5 10 15 20 0 0.3 0.6 0.9 1.2 1.5
Pressure [psi] Pressure [psi] Lugeons
Dilation
Lugeon: 0.1
Hydraulic Conductivity: 1.4467554E-6 cm/s
Hydraulic Conductivity: 1.250E-3 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Lithology: Caliza
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-7 -4
1 40.0 0.00007 0.00007 0.00007 0.00007 0.00007 0.00007 0.00007 0.00007 0.00007 0.00007 0.00007 1.3713917 × 10 1.185 × 10 0.0
-7 -4
2 85.0 0.00011 0.00011 0.00011 0.00011 0.00011 0.00011 0.00011 0.00011 0.00011 0.00011 0.00011 1.6627004 × 10 1.437 × 10 0.0
-7 -4
3 135.0 0.00015 0.00015 0.00015 0.00015 0.00015 0.00015 0.00015 0.00015 0.00015 0.00015 0.00015 1.8082918 × 10 1.562 × 10 0.0
-7 -4
4 85.0 0.00009 0.00009 0.00009 0.00009 0.00009 0.00009 0.00009 0.00009 0.00009 0.00009 0.00009 1.3603912 × 10 1.175 × 10 0.0
-7 -4
5 40.0 0.00006 0.00006 0.00006 0.00006 0.00006 0.00006 0.00006 0.00006 0.00006 0.00006 0.00006 1.1754786 × 10 1.016 × 10 0.0
-7 -4
Average 1.4756507 × 10 1.275 × 10 0.0
0.00015
1 0.00012 1
Flow [m³/min]
2 2
9E-5
Step
Step
3 3
6E-5
4 4
5 3E-5 5
0
0 40 80 120 160 0 40 80 120 160 0 0 0 0 0.0 0.0
Pressure [psi] Pressure [psi] Lugeons
Dilation
Lugeon: 0.0
Hydraulic Conductivity: 1.2867222E-7 cm/s
Hydraulic Conductivity: 1.112E-4 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Lithology: Caliza
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-6 -3
1 60.0 0.00198 0.00196 0.00188 0.00188 0.00188 0.00192 0.00194 0.00196 0.00196 0.00196 0.00193 2.6657515 × 10 2.303 × 10 0.2
-6 -3
2 90.0 0.00424 0.00426 0.00428 0.00436 0.00428 0.00432 0.00432 0.00440 0.00464 0.00464 0.00437 5.0991955 × 10 4.406 × 10 0.4
-6 -3
3 120.0 0.00870 0.00910 0.00910 0.00914 0.00920 0.00940 0.00936 0.00940 0.00920 0.00920 0.00918 9.2650905 × 10 8.005 × 10 0.7
-6 -3
4 90.0 0.00630 0.00624 0.00642 0.00644 0.00640 0.00636 0.00640 0.00624 0.00636 0.00620 0.00634 7.3864890 × 10 6.382 × 10 0.5
-6 -3
5 60.0 0.00368 0.00374 0.00386 0.00374 0.00380 0.00380 0.00380 0.00380 0.00380 0.00390 0.00379 5.2321583 × 10 4.521 × 10 0.4
-6 -3
Average 5.9297370 × 10 5.123 × 10 0.4
0.01
1 0.008 1
Flow [m³/min]
2 2
0.006
Step
Step
3 3
0.004
4 4
5 0.002 5
0
0 40 80 120 160 0 40 80 120 160 0 0.2 0.3 0.5 0.6 0.8
Pressure [psi] Pressure [psi] Lugeons
Dilation
Lugeon: 0.2
Hydraulic Conductivity: 2.6657515E-6 cm/s
Hydraulic Conductivity: 2.303E-3 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Lithology: Caliza
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-7 -4
1 30.0 0.00034 0.00034 0.00035 0.00034 0.00034 0.00034 0.00032 0.00035 0.00035 0.00035 0.00034 5.7798089 × 10 4.994 × 10 0.0
-7 -4
2 45.0 0.00038 0.00037 0.00035 0.00036 0.00038 0.00035 0.00037 0.00038 0.00034 0.00037 0.00037 5.5451582 × 10 4.791 × 10 0.0
-7 -4
3 75.0 0.00042 0.00043 0.00040 0.00047 0.00038 0.00039 0.00043 0.00040 0.00043 0.00043 0.00042 5.2826767 × 10 4.564 × 10 0.0
-7 -4
4 45.0 0.00037 0.00037 0.00037 0.00037 0.00030 0.00032 0.00031 0.00030 0.00033 0.00032 0.00034 5.1045840 × 10 4.410 × 10 0.0
-7 -4
5 30.0 0.00036 0.00032 0.00032 0.00026 0.00030 0.00032 0.00034 0.00031 0.00031 0.00032 0.00032 5.3404082 × 10 4.614 × 10 0.0
-7 -4
Average 5.4105272 × 10 4.675 × 10 0.0
0.0005
1 0.0004 1
Flow [m³/min]
2 2
0.0003
Step
Step
3 3
0.0002
4 4
5 0.0001 5
0
0 20 40 60 80 0 20 40 60 80 0 0 0.0 0.0 0.0 0.0
Pressure [psi] Pressure [psi] Lugeons
Laminar
Lugeon: 0.0
Hydraulic Conductivity: 5.4105272E-7 cm/s
Hydraulic Conductivity: 4.675E-4 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Lithology: Caliza
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-6 -3
1 2.0 0.00080 0.00050 0.00040 0.00020 0.00030 0.00030 0.00030 0.00040 0.00040 0.00030 0.00039 7.2679261 × 10 6.279 × 10 0.6
-6 -3
2 4.0 0.00070 0.00040 0.00060 0.00060 0.00050 0.00050 0.00070 0.00060 0.00060 0.00050 0.00057 9.6015910 × 10 8.296 × 10 0.8
-5 -2
3 6.0 0.00070 0.00090 0.00090 0.00100 0.00090 0.00090 0.00100 0.00090 0.00100 0.00110 0.00093 1.4292323 × 10 1.235 × 10 1.2
-6 -3
4 4.0 0.00050 0.00050 0.00060 0.00050 0.00050 0.00050 0.00050 0.00050 0.00050 0.00050 0.00051 8.5908972 × 10 7.423 × 10 0.7
-6 -3
5 2.0 0.00030 0.00030 0.00040 0.00030 0.00040 0.00040 0.00040 0.00040 0.00020 0.00040 0.00035 6.5224978 × 10 5.635 × 10 0.5
-6 -3
Average 9.2550470 × 10 7.996 × 10 0.8
0.001
1 0.0008 1
Flow [m³/min]
2 2
0.0006
Step
Step
3 3
0.0004
4 4
5 0.0002 5
0
0 2 4 6 8 0 2 4 6 8 0 0.3 0.6 0.9 1.2 1.5
Pressure [psi] Pressure [psi] Lugeons
Dilation
Lugeon: 0.5
Hydraulic Conductivity: 6.1497836E-6 cm/s
Hydraulic Conductivity: 5.313E-3 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Lithology: Caliza
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-6 -3
1 2.0 0.00070 0.00030 0.00060 0.00050 0.00040 0.00040 0.00060 0.00050 0.00060 0.00050 0.00051 9.1580013 × 10 7.913 × 10 0.8
-5 -2
2 4.0 0.00080 0.00060 0.00090 0.00080 0.00090 0.00080 0.00090 0.00070 0.00080 0.00080 0.00080 1.3030644 × 10 1.126 × 10 1.1
-5 -2
3 7.0 0.00160 0.00160 0.00160 0.00150 0.00150 0.00160 0.00180 0.00170 0.00160 0.00160 0.00161 2.3016161 × 10 1.989 × 10 1.9
-5 -2
4 4.0 0.00120 0.00120 0.00120 0.00150 0.00130 0.00130 0.00140 0.00150 0.00070 0.00140 0.00127 2.0686147 × 10 1.787 × 10 1.7
-5 -2
5 2.0 0.00080 0.00090 0.00100 0.00090 0.00090 0.00100 0.00100 0.00110 0.00070 0.00090 0.00092 1.6520316 × 10 1.427 × 10 1.4
-5 -2
Average 1.6482254 × 10 1.424 × 10 1.4
0.002
1 0.0016 1
Flow [m³/min]
2 2
0.0012
Step
Step
3 3
0.0008
4 4
5 0.0004 5
0
0 2 4 6 8 0 2 4 6 8 0 0.4 0.8 1.2 1.6 2
Pressure [psi] Pressure [psi] Lugeons
Dilation
Lugeon: 0.8
Hydraulic Conductivity: 9.1580013E-6 cm/s
Hydraulic Conductivity: 7.913E-3 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Lithology: Caliza
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-6 -3
1 2.0 0.00020 0.00040 0.00030 0.00030 0.00030 0.00030 0.00030 0.00030 0.00030 0.00030 0.00030 3.0509298 × 10 2.636 × 10 0.2
-6 -3
2 4.0 0.00120 0.00100 0.00080 0.00090 0.00090 0.00090 0.00080 0.00090 0.00090 0.00080 0.00091 8.4057728 × 10 7.263 × 10 0.6
-5 -2
3 8.0 0.00170 0.00170 0.00160 0.00160 0.00170 0.00160 0.00170 0.00160 0.00170 0.00160 0.00165 1.2879010 × 10 1.113 × 10 0.9
-6 -3
4 4.0 0.00090 0.00090 0.00080 0.00090 0.00090 0.00080 0.00090 0.00090 0.00080 0.00090 0.00087 8.0362883 × 10 6.943 × 10 0.6
-6 -3
5 2.0 0.00020 0.00020 0.00020 0.00020 0.00030 0.00020 0.00020 0.00020 0.00020 0.00020 0.00021 2.1356508 × 10 1.845 × 10 0.2
-6 -3
Average 6.9015303 × 10 5.963 × 10 0.5
0.002
1 0.0016 1
Flow [m³/min]
2 2
0.0012
Step
Step
3 3
0.0008
4 4
5 0.0004 5
0
0 2.5 5 7.5 10 0 2.5 5 7.5 10 0 0.2 0.4 0.6 0.8 1
Pressure [psi] Pressure [psi] Lugeons
Dilation
Lugeon: 0.2
Hydraulic Conductivity: 3.0509298E-6 cm/s
Hydraulic Conductivity: 2.636E-3 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Lithology: Caliza
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-6 -3
1 28.4 0.00030 0.00030 0.00040 0.00020 0.00030 0.00030 0.00030 0.00040 0.00040 0.00030 0.00032 3.5153841 × 10 3.037 × 10 0.3
-6 -3
2 56.9 0.00040 0.00040 0.00060 0.00060 0.00050 0.00050 0.00040 0.00060 0.00040 0.00050 0.00049 2.8435310 × 10 2.457 × 10 0.2
-6 -3
3 85.3 0.00070 0.00090 0.00090 0.00100 0.00090 0.00090 0.00100 0.00010 0.00100 0.00110 0.00085 3.3553308 × 10 2.899 × 10 0.3
-6 -3
4 56.9 0.00050 0.00050 0.00060 0.00050 0.00050 0.00050 0.00050 0.00050 0.00050 0.00050 0.00051 2.9595935 × 10 2.557 × 10 0.2
-6 -3
5 28.4 0.00030 0.00030 0.00040 0.00030 0.00040 0.00040 0.00040 0.00040 0.00020 0.00040 0.00035 3.8449513 × 10 3.322 × 10 0.3
-6 -3
Average 3.3037582 × 10 2.854 × 10 0.3
0.001
1 0.0008 1
Flow [m³/min]
2 2
0.0006
Step
Step
3 3
0.0004
4 4
5 0.0002 5
0
0 25 50 75 100 0 25 50 75 100 0 0.1 0.2 0.2 0.3 0.4
Pressure [psi] Pressure [psi] Lugeons
Laminar
Lugeon: 0.3
Hydraulic Conductivity: 3.4185793E-6 cm/s
Hydraulic Conductivity: 2.954E-3 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Lithology: Caliza
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-5 -2
1 28.4 0.00100 0.00100 0.00100 0.00100 0.00100 0.00100 0.00100 0.00100 0.00100 0.00100 0.00100 1.1914915 × 10 1.029 × 10 1.0
-6 -3
2 56.9 0.00120 0.00130 0.00120 0.00120 0.00120 0.00120 0.00120 0.00120 0.00120 0.00120 0.00121 7.3235277 × 10 6.328 × 10 0.6
-6 -3
3 99.6 0.00160 0.00160 0.00160 0.00150 0.00150 0.00160 0.00180 0.00170 0.00160 0.00160 0.00161 5.6094228 × 10 4.847 × 10 0.5
-6 -3
4 56.9 0.00120 0.00120 0.00120 0.00150 0.00130 0.00130 0.00140 0.00150 0.00130 0.00140 0.00133 8.0498279 × 10 6.955 × 10 0.7
-5 -2
5 28.4 0.00110 0.00110 0.00100 0.00090 0.00090 0.00100 0.00100 0.00110 0.00130 0.00110 0.00105 1.2510661 × 10 1.081 × 10 1.0
-6 -3
Average 9.0816707 × 10 7.847 × 10 0.8
0.002
1 0.0016 1
Flow [m³/min]
2 2
0.0012
Step
Step
3 3
0.0008
4 4
5 0.0004 5
0
0 30 60 90 120 0 30 60 90 120 0 0.3 0.6 0.9 1.2 1.5
Pressure [psi] Pressure [psi] Lugeons
Turbulent
Lugeon: 0.6
Hydraulic Conductivity: 7.3235277E-6 cm/s
Hydraulic Conductivity: 6.328E-3 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Lithology: Caliza
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-6 -3
1 28.4 0.00040 0.00040 0.00030 0.00030 0.00030 0.00030 0.00030 0.00030 0.00030 0.00030 0.00032 2.1908049 × 10 1.893 × 10 0.2
-6 -3
2 56.9 0.00080 0.00100 0.00080 0.00090 0.00090 0.00090 0.00080 0.00090 0.00090 0.00080 0.00087 3.0256382 × 10 2.614 × 10 0.2
-6 -3
3 113.8 0.00170 0.00186 0.00160 0.00160 0.00160 0.00160 0.00160 0.00170 0.00160 0.00165 2.8966789 × 10 2.503 × 10 0.2
-6 -3
4 56.9 0.00090 0.00090 0.00080 0.00090 0.00090 0.00080 0.00090 0.00090 0.00080 0.00090 0.00087 3.0256382 × 10 2.614 × 10 0.2
-6 -3
5 28.4 0.00020 0.00020 0.00020 0.00020 0.00030 0.00020 0.00020 0.00020 0.00020 0.00020 0.00021 1.4377157 × 10 1.242 × 10 0.1
-6 -3
Average 2.5152952 × 10 2.173 × 10 0.2
0.002
1 0.0016 1
Flow [m³/min]
2 2
0.0012
Step
Step
3 3
0.0008
4 4
5 0.0004 5
0
0 30 60 90 120 0 30 60 90 120 0 0.1 0.1 0.2 0.2 0.3
Pressure [psi] Pressure [psi] Lugeons
Laminar
Lugeon: 0.2
Hydraulic Conductivity: 2.5152952E-6 cm/s
Hydraulic Conductivity: 2.173E-3 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Lithology: Caliza
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-5 -2
1 6.0 0.00400 0.00350 0.00350 0.00400 0.00400 0.00350 0.00400 0.00400 0.00400 0.00400 0.00385 3.8845546 × 10 3.356 × 10 2.7
-5 -2
2 12.0 0.00400 0.00400 0.00350 0.00400 0.00350 0.00380 0.00400 0.00400 0.00400 0.00400 0.00388 2.9550852 × 10 2.553 × 10 2.1
-5 -2
3 20.0 0.00400 0.00400 0.00400 0.00400 0.00400 0.00400 0.00400 0.00400 0.00400 0.00400 0.00400 2.2959837 × 10 1.984 × 10 1.6
-5 -2
4 12.0 0.00400 0.00400 0.00400 0.00400 0.00350 0.00400 0.00400 0.00400 0.00400 0.00400 0.00395 3.0083986 × 10 2.599 × 10 2.1
-5 -2
5 6.0 0.00400 0.00400 0.00400 0.00400 0.00350 0.00400 0.00400 0.00400 0.00400 0.00400 0.00395 3.9854521 × 10 3.443 × 10 2.8
-5 -2
Average 3.2258948 × 10 2.787 × 10 2.3
0.005
1 0.004 1
Flow [m³/min]
2 2
0.003
Step
Step
3 3
0.002
4 4
5 0.001 5
0
0 7.5 15 22.5 30 0 7.5 15 22.5 30 0 0.6 1.2 1.8 2.4 3
Pressure [psi] Pressure [psi] Lugeons
Turbulent
Lugeon: 2.1
Hydraulic Conductivity: 2.9550852E-5 cm/s
Hydraulic Conductivity: 2.553E-2 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Lithology: Caliza
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-5 -2
1 10.0 0.00300 0.00300 0.00400 0.00400 0.00300 0.00400 0.00400 0.00400 0.00400 0.00400 0.00370 2.6080120 × 10 2.253 × 10 1.7
-5 -2
2 15.0 0.00500 0.00400 0.00500 0.00500 0.00400 0.00500 0.00500 0.00500 0.00500 0.00500 0.00480 2.5833161 × 10 2.232 × 10 1.6
-5 -2
3 25.0 0.00600 0.00600 0.00700 0.00700 0.00700 0.00700 0.00700 0.00700 0.00700 0.00700 0.00680 2.4846351 × 10 2.147 × 10 1.6
-5 -2
4 15.0 0.00500 0.00400 0.00400 0.00400 0.00400 0.00400 0.00400 0.00400 0.00400 0.00400 0.00410 2.2065825 × 10 1.906 × 10 1.4
-5 -2
5 10.0 0.00400 0.00300 0.00300 0.00300 0.00300 0.00300 0.00300 0.00300 0.00300 0.00300 0.00310 2.1850911 × 10 1.888 × 10 1.4
-5 -2
Average 2.4135274 × 10 2.085 × 10 1.5
0.0075
1 0.006 1
Flow [m³/min]
2 2
0.0045
Step
Step
3 3
0.003
4 4
5 0.0015 5
0
0 7.5 15 22.5 30 0 7.5 15 22.5 30 0 0.4 0.8 1.2 1.6 2
Pressure [psi] Pressure [psi] Lugeons
Laminar
Lugeon: 1.5
Hydraulic Conductivity: 2.4135274E-5 cm/s
Hydraulic Conductivity: 2.085E-2 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Lithology: Caliza
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-6 -3
1 15.0 0.00140 0.00130 0.00140 0.00140 0.00150 0.00140 0.00150 0.00140 0.00140 0.00140 0.00141 4.4463330 × 10 3.842 × 10 0.3
-6 -3
2 30.0 0.00320 0.00320 0.00350 0.00350 0.00370 0.00380 0.00370 0.00370 0.00380 0.00380 0.00359 7.9870713 × 10 6.901 × 10 0.5
-6 -3
3 45.0 0.00490 0.00490 0.00500 0.00490 0.00500 0.00480 0.00500 0.00510 0.00520 0.00490 0.00497 8.5419033 × 10 7.380 × 10 0.5
-6 -3
4 30.0 0.00380 0.00380 0.00380 0.00380 0.00380 0.00380 0.00380 0.00380 0.00380 0.00380 0.00380 8.4542816 × 10 7.304 × 10 0.5
-6 -3
5 15.0 0.00230 0.00210 0.00230 0.00230 0.00230 0.00220 0.00220 0.00230 0.00220 0.00220 0.00224 7.0636780 × 10 6.103 × 10 0.4
-6 -3
Average 7.2986534 × 10 6.306 × 10 0.5
0.005
1 0.004 1
Flow [m³/min]
2 2
0.003
Step
Step
3 3
0.002
4 4
5 0.001 5
0
0 12.5 25 37.5 50 0 12.5 25 37.5 50 0 0.2 0.3 0.5 0.6 0.8
Pressure [psi] Pressure [psi] Lugeons
Dilation
Lugeon: 0.3
Hydraulic Conductivity: 4.4463330E-6 cm/s
Hydraulic Conductivity: 3.842E-3 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Lithology: Caliza
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-6 -3
1 15.0 0.00160 0.00160 0.00160 0.00150 0.00160 0.00150 0.00150 0.00150 0.00160 0.00150 0.00155 4.7653779 × 10 4.117 × 10 0.3
-6 -3
2 30.0 0.00200 0.00190 0.00190 0.00190 0.00200 0.00200 0.00190 0.00190 0.00190 0.00190 0.00193 3.8555611 × 10 3.331 × 10 0.2
-6 -3
3 45.0 0.00300 0.00290 0.00290 0.00300 0.00290 0.00300 0.00290 0.00300 0.00300 0.00290 0.00295 4.3646250 × 10 3.771 × 10 0.3
-6 -3
4 30.0 0.00160 0.00160 0.00160 0.00150 0.00160 0.00150 0.00150 0.00160 0.00170 0.00170 0.00159 3.1763431 × 10 2.744 × 10 0.2
-6 -3
5 15.0 0.00130 0.00120 0.00130 0.00120 0.00130 0.00120 0.00130 0.00120 0.00130 0.00120 0.00125 3.8430467 × 10 3.320 × 10 0.2
-6 -3
Average 4.0009907 × 10 3.457 × 10 0.2
0.003
1 0.0024 1
Flow [m³/min]
2 2
0.0018
Step
Step
3 3
0.0012
4 4
5 0.0006 5
0
0 12.5 25 37.5 50 0 12.5 25 37.5 50 0 0.1 0.1 0.2 0.2 0.3
Pressure [psi] Pressure [psi] Lugeons
Laminar
Lugeon: 0.2
Hydraulic Conductivity: 4.0009907E-6 cm/s
Hydraulic Conductivity: 3.457E-3 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Lithology: Caliza
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-5 -2
1 30.0 0.02790 0.02780 0.02760 0.02790 0.02780 0.02760 0.02750 0.02790 0.02780 0.02760 0.02774 2.7807548 × 10 2.403 × 10 1.8
-5 -2
2 40.0 0.05600 0.05610 0.05630 0.05610 0.05660 0.05610 0.05640 0.05610 0.05620 0.05660 0.05625 5.1822052 × 10 4.477 × 10 3.3
-5 -2
3 50.0 0.06810 0.06790 0.06680 0.06780 0.06790 0.06760 0.06770 0.06710 0.06780 0.06750 0.06762 5.7631357 × 10 4.979 × 10 3.7
-5 -2
4 40.0 0.06150 0.06010 0.05910 0.05810 0.05710 0.05740 0.05790 0.05710 0.05760 0.05700 0.05829 5.3701465 × 10 4.640 × 10 3.4
-5 -2
5 30.0 0.02760 0.02700 0.02840 0.02850 0.02800 0.02800 0.02810 0.02840 0.02800 0.02830 0.02803 2.8098254 × 10 2.428 × 10 1.8
-5 -2
Average 4.3812135 × 10 3.785 × 10 2.8
0.075
1 0.06 1
Flow [m³/min]
2 2
0.045
Step
Step
3 3
0.03
4 4
5 0.015 5
0
0 15 30 45 60 0 15 30 45 60 0 0.8 1.6 2.4 3.2 4
Pressure [psi] Pressure [psi] Lugeons
Dilation
Lugeon: 1.8
Hydraulic Conductivity: 2.7807548E-5 cm/s
Hydraulic Conductivity: 2.403E-2 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Lithology: Caliza
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-4 -1
1 5.0 0.05500 0.05400 0.05400 0.05100 0.05200 0.05200 0.05200 0.05100 0.05200 0.05100 0.05240 1.8237303 × 10 1.576 × 10 11.3
-4 -1
2 10.0 0.08800 0.08600 0.08500 0.08800 0.08600 0.08600 0.08600 0.08400 0.08800 0.08700 0.08640 2.5524298 × 10 2.205 × 10 15.8
-4 -1
3 13.5 0.10500 0.10300 0.10150 0.10250 0.10300 0.10200 0.10200 0.10200 0.10200 0.10100 0.10240 2.7355875 × 10 2.364 × 10 16.9
-4 -1
4 10.0 0.09100 0.09100 0.09000 0.09100 0.09000 0.09100 0.09000 0.09000 0.09100 0.08900 0.09040 2.6705979 × 10 2.307 × 10 16.5
-4 -1
5 5.0 0.06500 0.06400 0.06300 0.06300 0.06300 0.06300 0.06300 0.06300 0.06300 0.06200 0.06320 2.1996137 × 10 1.900 × 10 13.6
-4 -1
Average 2.3963918 × 10 2.070 × 10 14.8
0.15
1 0.12 1
Flow [m³/min]
2 2
0.09
Step
Step
3 3
0.06
4 4
5 0.03 5
0
0 4 8 12 16 0 4 8 12 16 0 4 8 12 16 20
Pressure [psi] Pressure [psi] Lugeons
Dilation
Lugeon: 11.3
Hydraulic Conductivity: 1.8237303E-4 cm/s
Hydraulic Conductivity: 1.576E-1 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Lithology: Caliza
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-5 -2
1 6.0 0.06800 0.06700 0.06800 0.06900 0.06700 0.06900 0.06700 0.06700 0.06800 0.06900 0.06790 4.2019286 × 10 3.630 × 10 2.4
-5 -2
2 10.0 0.08000 0.08000 0.08400 0.08400 0.08000 0.08200 0.08300 0.08200 0.08300 0.08000 0.08180 4.8690936 × 10 4.207 × 10 2.8
-5 -2
3 14.0 0.09500 0.09400 0.09400 0.09900 0.09600 0.09800 0.09400 0.09600 0.09500 0.09600 0.09570 5.4872481 × 10 4.741 × 10 3.1
-5 -2
4 10.0 0.08200 0.08100 0.08300 0.08000 0.08100 0.08300 0.08600 0.08600 0.08600 0.08000 0.08280 4.9286180 × 10 4.258 × 10 2.8
-5 -2
5 6.0 0.07000 0.07000 0.07000 0.06800 0.07000 0.06900 0.06800 0.06800 0.06800 0.07000 0.06910 4.2761895 × 10 3.695 × 10 2.4
-5 -2
Average 4.7526156 × 10 4.106 × 10 2.7
0.1
1 0.08 1
Flow [m³/min]
2 2
0.06
Step
Step
3 3
0.04
4 4
5 0.02 5
0
0 4 8 12 16 0 4 8 12 16 0 0.8 1.6 2.4 3.2 4
Pressure [psi] Pressure [psi] Lugeons
Dilation
Lugeon: 2.4
Hydraulic Conductivity: 4.2019286E-5 cm/s
Hydraulic Conductivity: 3.630E-2 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Lithology: Caliza
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-6 -3
1 15.0 0.00500 0.00500 0.00500 0.00500 0.00400 0.00500 0.00500 0.00600 0.00500 0.00500 0.00500 5.4555007 × 10 4.714 × 10 0.4
-5 -3
2 30.0 0.01100 0.01100 0.01000 0.01000 0.01100 0.01100 0.01200 0.01100 0.01200 0.01100 0.01100 1.0554118 × 10 9.119 × 10 0.7
-5 -2
3 45.0 0.02500 0.02500 0.02600 0.02500 0.02700 0.02700 0.02700 0.02700 0.02700 0.02600 0.02620 2.2431731 × 10 1.938 × 10 1.4
-5 -3
4 30.0 0.01200 0.00900 0.01200 0.01100 0.01200 0.01200 0.01100 0.01000 0.01300 0.01200 0.01140 1.0937904 × 10 9.450 × 10 0.7
-6 -3
5 15.0 0.00700 0.00800 0.00700 0.00800 0.00700 0.00700 0.00900 0.00800 0.00700 0.00800 0.00760 8.2923611 × 10 7.165 × 10 0.5
-5 -3
Average 1.1534323 × 10 9.966 × 10 0.7
0.03
1 0.024 1
Flow [m³/min]
2 2
0.018
Step
Step
3 3
0.012
4 4
5 0.006 5
0
0 12.5 25 37.5 50 0 12.5 25 37.5 50 0 0.3 0.6 0.9 1.2 1.5
Pressure [psi] Pressure [psi] Lugeons
Dilation
Lugeon: 0.4
Hydraulic Conductivity: 5.4555007E-6 cm/s
Hydraulic Conductivity: 4.714E-3 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Lithology: Caliza
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-5 -2
1 5.0 0.01700 0.01700 0.01700 0.01700 0.01600 0.01700 0.01700 0.01700 0.01700 0.01700 0.01690 6.7825999 × 10 5.860 × 10 3.9
-4 -2
2 10.0 0.03400 0.03400 0.03400 0.03400 0.03400 0.03400 0.03400 0.03400 0.03400 0.03400 0.03400 1.0603900 × 10 9.162 × 10 6.2
-4 -1
3 15.0 0.04700 0.04700 0.04700 0.04700 0.04700 0.04700 0.04700 0.04700 0.04700 0.04700 0.04700 1.1986540 × 10 1.036 × 10 7.0
-4 -2
4 10.0 0.03600 0.03500 0.03500 0.03500 0.03500 0.03500 0.03500 0.03500 0.03500 0.03500 0.03510 1.0946968 × 10 9.458 × 10 6.4
-5 -2
5 5.0 0.02300 0.02200 0.02200 0.02200 0.02200 0.02200 0.02200 0.02200 0.02200 0.02200 0.02210 8.8695537 × 10 7.663 × 10 5.2
-5 -2
Average 9.8379124 × 10 8.500 × 10 5.7
0.05
1 0.04 1
Flow [m³/min]
2 2
0.03
Step
Step
3 3
0.02
4 4
5 0.01 5
0
0 4 8 12 16 0 4 8 12 16 0 1.5 3 4.5 6 7.5
Pressure [psi] Pressure [psi] Lugeons
Dilation
Lugeon: 3.9
Hydraulic Conductivity: 6.7825999E-5 cm/s
Hydraulic Conductivity: 5.860E-2 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Lithology: Caliza
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-5 -2
1 3.0 0.03800 0.03800 0.03800 0.03800 0.03800 0.03800 0.03800 0.03800 0.03800 0.03800 0.03800 9.7724212 × 10 8.443 × 10 5.6
-4 -1
2 6.0 0.05700 0.05800 0.05800 0.05800 0.05800 0.05800 0.05800 0.05800 0.05800 0.05800 0.05790 1.3290901 × 10 1.148 × 10 7.6
-4 -1
3 9.5 0.07700 0.07700 0.07700 0.07700 0.07700 0.07700 0.07700 0.07700 0.07700 0.07700 0.07700 1.5707195 × 10 1.357 × 10 9.0
-4 -1
4 6.0 0.06200 0.06200 0.06200 0.06200 0.06200 0.06200 0.06200 0.06200 0.06200 0.06200 0.06200 1.4232053 × 10 1.230 × 10 8.1
-4 -2
5 3.0 0.04100 0.04100 0.04000 0.04100 0.04000 0.04000 0.04000 0.04000 0.04000 0.04000 0.04030 1.0363910 × 10 8.954 × 10 5.9
-4 -1
Average 1.2673296 × 10 1.095 × 10 7.3
0.1
1 0.08 1
Flow [m³/min]
2 2
0.06
Step
Step
3 3
0.04
4 4
5 0.02 5
0
0 2.5 5 7.5 10 0 2.5 5 7.5 10 0 2 4 6 8 10
Pressure [psi] Pressure [psi] Lugeons
Dilation
Lugeon: 5.6
Hydraulic Conductivity: 9.7724212E-5 cm/s
Hydraulic Conductivity: 8.443E-2 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Lithology: Caliza
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-5 -2
1 3.0 0.00170 0.00170 0.00170 0.00160 0.00170 0.00180 0.00170 0.00170 0.00160 0.00170 0.00169 4.5522182 × 10 3.933 × 10 2.9
-5 -2
2 5.0 0.00210 0.00210 0.00210 0.00220 0.00210 0.00210 0.00220 0.00210 0.00210 0.00210 0.00212 3.8146037 × 10 3.296 × 10 2.4
-5 -2
3 7.0 0.00450 0.00450 0.00450 0.00450 0.00450 0.00450 0.00450 0.00450 0.00450 0.00450 0.00450 6.0788610 × 10 5.252 × 10 3.8
-5 -2
4 5.0 0.00240 0.00250 0.00240 0.00240 0.00250 0.00250 0.00250 0.00250 0.00250 0.00250 0.00247 4.4443731 × 10 3.840 × 10 2.8
-5 -2
5 3.0 0.00220 0.00210 0.00220 0.00220 0.00220 0.00220 0.00220 0.00220 0.00220 0.00220 0.00219 5.8990283 × 10 5.097 × 10 3.7
-5 -2
Average 4.9578168 × 10 4.284 × 10 3.1
0.005
1 0.004 1
Flow [m³/min]
2 2
0.003
Step
Step
3 3
0.002
4 4
5 0.001 5
0
0 2 4 6 8 0 2 4 6 8 0 0.8 1.6 2.4 3.2 4
Pressure [psi] Pressure [psi] Lugeons
Laminar
Lugeon: 3.1
Hydraulic Conductivity: 4.9578168E-5 cm/s
Hydraulic Conductivity: 4.284E-2 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Lithology: Caliza
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-6 -3
1 21.8 0.00210 0.00250 0.00260 0.00260 0.00260 0.00260 0.00260 0.00260 0.00260 0.00260 0.00254 6.6389497 × 10 5.736 × 10 0.4
-5 -2
2 43.5 0.00660 0.00700 0.00740 0.00770 0.00800 0.00890 0.00930 0.00960 0.00800 0.00820 0.00807 1.4387802 × 10 1.243 × 10 0.9
-5 -2
3 79.8 0.01790 0.01720 0.01890 0.01830 0.01820 0.01840 0.01950 0.01730 0.01850 0.01870 0.01829 2.1315516 × 10 1.842 × 10 1.4
-5 -2
4 43.5 0.00850 0.00930 0.00930 0.00950 0.00970 0.00970 0.00960 0.00960 0.00940 0.00960 0.00942 1.6794683 × 10 1.451 × 10 1.1
-5 -2
5 21.8 0.00520 0.00510 0.00530 0.00510 0.00510 0.00500 0.00540 0.00520 0.00520 0.00530 0.00519 1.3565413 × 10 1.172 × 10 0.9
-5 -2
Average 1.4540473 × 10 1.256 × 10 0.9
0.02
1 0.016 1
Flow [m³/min]
2 2
0.012
Step
Step
3 3
0.008
4 4
5 0.004 5
0
0 25 50 75 100 0 25 50 75 100 0 0.3 0.6 0.9 1.2 1.5
Pressure [psi] Pressure [psi] Lugeons
Dilation
Lugeon: 0.4
Hydraulic Conductivity: 6.6389497E-6 cm/s
Hydraulic Conductivity: 5.736E-3 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Lithology: Caliza
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-5 -2
1 10.0 0.04800 0.04800 0.04800 0.04800 0.04800 0.04800 0.04800 0.04800 0.04800 0.04800 0.04800 8.3679488 × 10 7.230 × 10 4.9
-4 -2
2 15.0 0.06500 0.06500 0.06500 0.06500 0.06500 0.06500 0.06500 0.06500 0.06500 0.06500 0.06500 1.0085476 × 10 8.714 × 10 5.9
-5 -2
3 22.0 0.07400 0.07400 0.07400 0.07400 0.07400 0.07400 0.07400 0.07400 0.07400 0.07400 0.07400 9.9500542 × 10 8.597 × 10 5.8
-4 -2
4 15.0 0.06600 0.06600 0.06600 0.06600 0.06600 0.06600 0.06600 0.06600 0.06600 0.06600 0.06600 1.0240637 × 10 8.848 × 10 6.0
-4 -2
5 10.0 0.05800 0.05800 0.05800 0.05800 0.05800 0.05800 0.05800 0.05800 0.05800 0.05800 0.05800 1.0111272 × 10 8.736 × 10 5.9
-5 -2
Average 9.7510776 × 10 8.425 × 10 5.7
0.075
1 0.06 1
Flow [m³/min]
2 2
0.045
Step
Step
3 3
0.03
4 4
5 0.015 5
0
0 7.5 15 22.5 30 0 7.5 15 22.5 30 0 1.5 3 4.5 6 7.5
Pressure [psi] Pressure [psi] Lugeons
Laminar
Lugeon: 5.7
Hydraulic Conductivity: 9.7510776E-5 cm/s
Hydraulic Conductivity: 8.425E-2 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Lithology: Caliza
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-5 -2
1 3.0 0.03800 0.03800 0.03800 0.03800 0.03800 0.03800 0.03800 0.03800 0.03800 0.03800 0.03800 8.1566978 × 10 7.047 × 10 4.7
-5 -2
2 6.5 0.04700 0.04700 0.04600 0.04600 0.04600 0.04600 0.04600 0.04600 0.04600 0.04600 0.04620 8.8567870 × 10 7.652 × 10 5.1
-5 -2
3 15.0 0.06200 0.06200 0.06200 0.06200 0.06200 0.06200 0.06200 0.06200 0.06200 0.06200 0.06200 9.4361344 × 10 8.153 × 10 5.4
-5 -2
4 6.5 0.04200 0.04300 0.04300 0.04300 0.04300 0.04300 0.04300 0.04300 0.04300 0.04300 0.04290 8.2241593 × 10 7.106 × 10 4.7
-5 -2
5 3.0 0.03500 0.03500 0.03500 0.03500 0.03500 0.03500 0.03500 0.03500 0.03500 0.03500 0.03500 7.5127480 × 10 6.491 × 10 4.3
-5 -2
Average 8.4373053 × 10 7.290 × 10 4.8
0.075
1 0.06 1
Flow [m³/min]
2 2
0.045
Step
Step
3 3
0.03
4 4
5 0.015 5
0
0 4 8 12 16 0 4 8 12 16 0 1.5 3 4.5 6 7.5
Pressure [psi] Pressure [psi] Lugeons
Dilation
Lugeon: 4.7
Hydraulic Conductivity: 8.1566978E-5 cm/s
Hydraulic Conductivity: 7.047E-2 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Lithology: Caliza
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-6 -3
1 14.5 0.00020 0.00020 0.00020 0.00020 0.00020 0.00020 0.00020 0.00020 0.00020 0.00020 0.00020 1.4240853 × 10 1.230 × 10 0.1
-6 -3
2 21.8 0.00100 0.00100 0.00100 0.00100 0.00100 0.00100 0.00100 0.00100 0.00100 0.00100 0.00100 5.3065198 × 10 4.585 × 10 0.4
-6 -3
3 29.0 0.00200 0.00210 0.00200 0.00200 0.00200 0.00200 0.00200 0.00200 0.00210 0.00200 0.00202 8.5667199 × 10 7.402 × 10 0.6
-6 -3
4 21.8 0.00120 0.00120 0.00120 0.00120 0.00120 0.00120 0.00120 0.00120 0.00120 0.00120 0.00120 6.3678238 × 10 5.502 × 10 0.4
-6 -3
5 14.5 0.00030 0.00030 0.00030 0.00030 0.00030 0.00030 0.00030 0.00030 0.00030 0.00030 0.00030 2.1361279 × 10 1.846 × 10 0.1
-6 -3
Average 4.7602553 × 10 4.113 × 10 0.3
0.003
1 0.0024 1
Flow [m³/min]
2 2
0.0018
Step
Step
3 3
0.0012
4 4
5 0.0006 5
0
0 7.5 15 22.5 30 0 7.5 15 22.5 30 0 0.2 0.3 0.5 0.6 0.8
Pressure [psi] Pressure [psi] Lugeons
Dilation
Lugeon: 0.1
Hydraulic Conductivity: 1.4240853E-6 cm/s
Hydraulic Conductivity: 1.230E-3 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Lithology: Caliza
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-5 -2
1 14.5 0.00900 0.00900 0.00880 0.00890 0.00880 0.00880 0.00870 0.00870 0.00870 0.00860 0.00880 3.7046603 × 10 3.201 × 10 2.2
-5 -2
2 21.8 0.01220 0.01220 0.01220 0.01220 0.01210 0.01210 0.01210 0.01210 0.01210 0.01210 0.01214 3.6094203 × 10 3.119 × 10 2.1
-5 -2
3 29.0 0.01620 0.01620 0.01630 0.01630 0.01620 0.01630 0.01630 0.01620 0.01610 0.01670 0.01628 3.7412769 × 10 3.232 × 10 2.2
-5 -2
4 21.8 0.01180 0.01180 0.01180 0.01180 0.01180 0.01180 0.01180 0.01180 0.01180 0.01180 0.01180 3.5083327 × 10 3.031 × 10 2.1
-5 -2
5 14.5 0.00870 0.00880 0.00880 0.00870 0.00890 0.00890 0.00870 0.00880 0.00880 0.00880 0.00879 3.7004504 × 10 3.197 × 10 2.2
-5 -2
Average 3.6528281 × 10 3.156 × 10 2.1
0.02
1 0.016 1
Flow [m³/min]
2 2
0.012
Step
Step
3 3
0.008
4 4
5 0.004 5
0
0 7.5 15 22.5 30 0 7.5 15 22.5 30 0 0.6 1.2 1.8 2.4 3
Pressure [psi] Pressure [psi] Lugeons
Laminar
Lugeon: 2.1
Hydraulic Conductivity: 3.6528281E-5 cm/s
Hydraulic Conductivity: 3.156E-2 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Lithology: Caliza
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-6 -3
1 20.0 0.00140 0.00140 0.00140 0.00140 0.00140 0.00140 0.00140 0.00140 0.00140 0.00140 0.00140 3.3371145 × 10 2.883 × 10 0.2
-6 -3
2 40.0 0.00290 0.00280 0.00280 0.00290 0.00290 0.00280 0.00280 0.00290 0.00290 0.00290 0.00286 3.6391672 × 10 3.144 × 10 0.2
-6 -3
3 60.0 0.00520 0.00520 0.00550 0.00540 0.00590 0.00510 0.00530 0.00520 0.00530 0.00570 0.00538 4.6690686 × 10 4.034 × 10 0.3
-6 -3
4 40.0 0.00480 0.00480 0.00460 0.00470 0.00460 0.00460 0.00460 0.00450 0.00440 0.00440 0.00460 5.8532060 × 10 5.057 × 10 0.3
-6 -3
5 20.0 0.00300 0.00300 0.00300 0.00300 0.00300 0.00300 0.00300 0.00300 0.00300 0.00300 0.00300 7.1509596 × 10 6.178 × 10 0.4
-6 -3
Average 4.9299032 × 10 4.259 × 10 0.3
0.0075
1 0.006 1
Flow [m³/min]
2 2
0.0045
Step
Step
3 3
0.003
4 4
5 0.0015 5
0
0 20 40 60 80 0 20 40 60 80 0 0.1 0.2 0.2 0.3 0.4
Pressure [psi] Pressure [psi] Lugeons
Wash out
Lugeon: 0.4
Hydraulic Conductivity: 7.1509596E-6 cm/s
Hydraulic Conductivity: 6.178E-3 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Lithology: Caliza
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-4 -1
1 5.0 0.04540 0.04530 0.04540 0.04540 0.04520 0.04520 0.04520 0.04520 0.04520 0.04520 0.04527 3.7741348 × 10 3.261 × 10 26.0
-4 -1
2 10.0 0.06640 0.06650 0.06550 0.06550 0.06550 0.06540 0.06540 0.06540 0.06540 0.06540 0.06564 4.3668468 × 10 3.773 × 10 30.1
-4 -1
3 15.0 0.09530 0.09430 0.09520 0.09430 0.09420 0.09410 0.09420 0.09430 0.09430 0.09440 0.09446 5.2280042 × 10 4.517 × 10 36.0
-4 -1
4 10.0 0.06740 0.06650 0.06620 0.06600 0.06580 0.06570 0.06570 0.06540 0.06530 0.06540 0.06594 4.3868049 × 10 3.790 × 10 30.2
-4 -1
5 5.0 0.04780 0.04630 0.04600 0.04560 0.04550 0.04540 0.04550 0.04530 0.04530 0.04530 0.04580 3.8183206 × 10 3.299 × 10 26.3
-4 -1
Average 4.3148223 × 10 3.728 × 10 29.7
0.1
1 0.08 1
Flow [m³/min]
2 2
0.06
Step
Step
3 3
0.04
4 4
5 0.02 5
0
0 4 8 12 16 0 4 8 12 16 0 8 16 24 32 40
Pressure [psi] Pressure [psi] Lugeons
Dilation
Lugeon: 26.0
Hydraulic Conductivity: 3.7741348E-4 cm/s
Hydraulic Conductivity: 3.261E-1 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Lithology: Caliza
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-4 -1
1 6.0 0.10190 0.10280 0.10080 0.10110 0.10150 0.10150 0.10150 0.10160 0.10070 0.10110 0.10145 7.1311480 × 10 6.161 × 10 50.2
-4 -1
2 12.0 0.11770 0.11650 0.11670 0.11670 0.11780 0.11790 0.11770 0.11780 0.11770 0.11750 0.11740 6.7021835 × 10 5.791 × 10 47.2
-4 -1
3 18.0 0.13190 0.13090 0.13180 0.13080 0.13130 0.13140 0.13100 0.13100 0.13070 0.13050 0.13113 6.3021945 × 10 5.445 × 10 44.4
-4 -1
4 12.0 0.11980 0.11930 0.12000 0.11890 0.11840 0.11900 0.11800 0.11840 0.11870 0.11830 0.11888 6.7866744 × 10 5.864 × 10 47.8
-4 -1
5 6.0 0.10290 0.10200 0.10270 0.10320 0.10310 0.10290 0.10290 0.10240 0.10250 0.10270 0.10273 7.2211221 × 10 6.239 × 10 50.8
-4 -1
Average 6.8286645 × 10 5.900 × 10 48.1
0.15
1 0.12 1
Flow [m³/min]
2 2
0.09
Step
Step
3 3
0.06
4 4
5 0.03 5
0
0 5 10 15 20 0 5 10 15 20 0 15 30 45 60 75
Pressure [psi] Pressure [psi] Lugeons
Turbulent
Lugeon: 47.2
Hydraulic Conductivity: 6.7021835E-4 cm/s
Hydraulic Conductivity: 5.791E-1 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-5 -2
1 7.5 0.00600 0.00600 0.00600 0.00610 0.00600 0.00620 0.00620 0.00620 0.00620 0.00630 0.00612 5.6588542 × 10 4.889 × 10 4.1
-5 -2
2 14.5 0.00650 0.00670 0.00670 0.00660 0.00660 0.00660 0.00660 0.00570 0.00750 0.00660 0.00661 4.5984722 × 10 3.973 × 10 3.3
-5 -2
3 21.8 0.00770 0.00760 0.00770 0.00770 0.00770 0.00770 0.00770 0.00750 0.00770 0.00770 0.00767 4.2467450 × 10 3.669 × 10 3.0
-5 -2
4 14.5 0.00650 0.00650 0.00650 0.00650 0.00650 0.00660 0.00650 0.00660 0.00650 0.00630 0.00650 4.5219469 × 10 3.907 × 10 3.2
-5 -2
5 7.5 0.00560 0.00530 0.00570 0.00570 0.00580 0.00580 0.00590 0.00590 0.00550 0.00500 0.00562 5.1965295 × 10 4.490 × 10 3.7
-5 -2
Average 4.8445096 × 10 4.186 × 10 3.5
0.01
1 0.008 1
Flow [m³/min]
2 2
0.006
Step
Step
3 3
0.004
4 4
5 0.002 5
0
0 7.5 15 22.5 30 0 7.5 15 22.5 30 0 1 2 3 4 5
Pressure [psi] Pressure [psi] Lugeons
Turbulent
Lugeon: 3.3
Hydraulic Conductivity: 4.5984722E-5 cm/s
Hydraulic Conductivity: 3.973E-2 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-5 -2
1 12.5 0.01000 0.01000 0.00980 0.00990 0.00980 0.00980 0.00970 0.00970 0.00970 0.00970 0.00981 4.8008835 × 10 4.148 × 10 3.0
-5 -2
2 25.0 0.01220 0.01230 0.01220 0.01220 0.01210 0.01230 0.01220 0.01210 0.01220 0.01220 0.01220 3.6277339 × 10 3.134 × 10 2.2
-5 -2
3 50.0 0.01760 0.01760 0.01750 0.01770 0.01750 0.01760 0.01690 0.01680 0.01710 0.01670 0.01730 2.8822789 × 10 2.490 × 10 1.8
-5 -2
4 25.0 0.01150 0.01170 0.01160 0.01160 0.01160 0.01160 0.01160 0.01150 0.01160 0.01160 0.01159 3.4463472 × 10 2.978 × 10 2.1
-5 -2
5 12.5 0.00870 0.00880 0.00880 0.00870 0.00890 0.00890 0.00870 0.00880 0.00880 0.00880 0.00879 4.3017090 × 10 3.717 × 10 2.6
-5 -2
Average 3.8117905 × 10 3.293 × 10 2.3
0.02
1 0.016 1
Flow [m³/min]
2 2
0.012
Step
Step
3 3
0.008
4 4
5 0.004 5
0
0 15 30 45 60 0 15 30 45 60 0 0.6 1.2 1.8 2.4 3
Pressure [psi] Pressure [psi] Lugeons
Turbulent
Lugeon: 2.2
Hydraulic Conductivity: 3.6277339E-5 cm/s
Hydraulic Conductivity: 3.134E-2 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-5 -2
1 7.3 0.00420 0.00410 0.00420 0.00410 0.00410 0.00410 0.00400 0.00400 0.00380 0.00400 0.00406 4.9710590 × 10 4.295 × 10 3.2
-5 -2
2 14.5 0.00590 0.00570 0.00580 0.00580 0.00570 0.00490 0.00560 0.00570 0.00560 0.00560 0.00563 4.0167017 × 10 3.470 × 10 2.6
-5 -2
3 29.0 0.00960 0.00950 0.00940 0.00960 0.00950 0.00980 0.00940 0.00950 0.00960 0.00960 0.00955 3.7138033 × 10 3.209 × 10 2.4
-5 -2
4 14.5 0.00560 0.00560 0.00560 0.00550 0.00560 0.00550 0.00550 0.00610 0.00490 0.00560 0.00555 3.9596260 × 10 3.421 × 10 2.6
-5 -2
5 7.3 0.00430 0.00420 0.00430 0.00420 0.00430 0.00420 0.00420 0.00420 0.00440 0.00420 0.00425 5.2036947 × 10 4.496 × 10 3.4
-5 -2
Average 4.3729769 × 10 3.778 × 10 2.8
0.01
1 0.008 1
Flow [m³/min]
2 2
0.006
Step
Step
3 3
0.004
4 4
5 0.002 5
0
0 7.5 15 22.5 30 0 7.5 15 22.5 30 0 0.8 1.6 2.4 3.2 4
Pressure [psi] Pressure [psi] Lugeons
Turbulent
Lugeon: 2.6
Hydraulic Conductivity: 4.0167017E-5 cm/s
Hydraulic Conductivity: 3.470E-2 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-6 -3
1 14.5 0.00190 0.00190 0.00190 0.00190 0.00190 0.00190 0.00190 0.00190 0.00190 0.00190 0.00190 8.1286278 × 10 7.023 × 10 0.5
-6 -3
2 29.0 0.00270 0.00270 0.00270 0.00270 0.00270 0.00270 0.00270 0.00270 0.00270 0.00270 0.00270 5.9726087 × 10 5.160 × 10 0.3
-6 -3
3 43.5 0.00340 0.00340 0.00340 0.00330 0.00330 0.00330 0.00330 0.00330 0.00340 0.00320 0.00333 4.9672893 × 10 4.292 × 10 0.3
-6 -3
4 29.0 0.00260 0.00260 0.00260 0.00260 0.00260 0.00260 0.00260 0.00260 0.00260 0.00250 0.00259 5.7292802 × 10 4.950 × 10 0.3
-6 -3
5 14.5 0.00190 0.00190 0.00180 0.00190 0.00190 0.00180 0.00180 0.00180 0.00190 0.00190 0.00186 7.9574987 × 10 6.875 × 10 0.5
-6 -3
Average 6.5510609 × 10 5.660 × 10 0.4
0.004
1 0.0032 1
Flow [m³/min]
2 2
0.0024
Step
Step
3 3
0.0016
4 4
5 0.0008 5
0
0 12.5 25 37.5 50 0 12.5 25 37.5 50 0 0.1 0.2 0.3 0.4 0.5
Pressure [psi] Pressure [psi] Lugeons
Turbulent
Lugeon: 0.3
Hydraulic Conductivity: 5.9726087E-6 cm/s
Hydraulic Conductivity: 5.160E-3 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-5 -2
1 7.3 0.01280 0.01300 0.01320 0.01340 0.01340 0.01380 0.01320 0.01370 0.01410 0.01440 0.01350 3.0915337 × 10 2.671 × 10 1.7
-5 -2
2 14.5 0.02720 0.02640 0.02740 0.02750 0.02730 0.02750 0.02720 0.02750 0.02730 0.02750 0.02728 4.7099594 × 10 4.069 × 10 2.6
-5 -2
3 21.8 0.04390 0.04370 0.04350 0.04380 0.04370 0.04380 0.04390 0.04370 0.04370 0.04390 0.04376 6.0632939 × 10 5.239 × 10 3.3
-5 -2
4 14.5 0.03620 0.03690 0.03700 0.03670 0.03690 0.03650 0.03690 0.03690 0.03690 0.03690 0.03678 6.3501579 × 10 5.487 × 10 3.5
-5 -2
5 7.3 0.02860 0.02890 0.02860 0.02860 0.02850 0.02850 0.02840 0.02840 0.02810 0.02830 0.02849 6.5242811 × 10 5.637 × 10 3.6
-5 -2
Average 5.3478452 × 10 4.621 × 10 2.9
0.05
1 0.04 1
Flow [m³/min]
2 2
0.03
Step
Step
3 3
0.02
4 4
5 0.01 5
0
0 7.5 15 22.5 30 0 7.5 15 22.5 30 0 0.8 1.6 2.4 3.2 4
Pressure [psi] Pressure [psi] Lugeons
Wash out
Lugeon: 3.6
Hydraulic Conductivity: 6.5242811E-5 cm/s
Hydraulic Conductivity: 5.637E-2 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-4 -1
1 7.3 0.04430 0.04430 0.04490 0.04410 0.04450 0.04490 0.04520 0.04500 0.04490 0.04480 0.04469 1.1952469 × 10 1.033 × 10 6.8
-4 -2
2 14.5 0.05530 0.05530 0.05380 0.05510 0.05450 0.05490 0.05070 0.05910 0.05390 0.05400 0.05466 1.1021723 × 10 9.523 × 10 6.2
-4 -2
3 21.8 0.06560 0.06640 0.06590 0.06580 0.06680 0.06620 0.06580 0.06670 0.06530 0.06630 0.06608 1.0693218 × 10 9.239 × 10 6.0
-4 -1
4 14.5 0.05760 0.05770 0.05700 0.05720 0.05750 0.05730 0.05780 0.05800 0.05740 0.05770 0.05752 1.1598418 × 10 1.002 × 10 6.6
-4 -1
5 7.3 0.04590 0.04690 0.04440 0.04410 0.04670 0.04690 0.04540 0.04520 0.04690 0.04600 0.04584 1.2260040 × 10 1.059 × 10 6.9
-4 -2
Average 1.1505174 × 10 9.940 × 10 6.5
0.075
1 0.06 1
Flow [m³/min]
2 2
0.045
Step
Step
3 3
0.03
4 4
5 0.015 5
0
0 7.5 15 22.5 30 0 7.5 15 22.5 30 0 1.5 3 4.5 6 7.5
Pressure [psi] Pressure [psi] Lugeons
Turbulent
Lugeon: 6.2
Hydraulic Conductivity: 1.1021723E-4 cm/s
Hydraulic Conductivity: 9.523E-2 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-4 -1
1 6.0 0.02310 0.02320 0.02250 0.02310 0.02290 0.02300 0.02300 0.02320 0.02290 0.02290 0.02298 4.5731403 × 10 3.951 × 10 39.7
-4 -1
2 12.0 0.04280 0.04270 0.04280 0.04260 0.04280 0.04270 0.04240 0.04260 0.04260 0.04280 0.04268 6.6035333 × 10 5.705 × 10 57.4
-4 -1
3 18.0 0.05860 0.05750 0.05780 0.05730 0.05780 0.05740 0.05770 0.05770 0.05780 0.05810 0.05777 7.3113443 × 10 6.317 × 10 63.5
-4 -1
4 12.0 0.05110 0.05120 0.05060 0.05090 0.05070 0.05130 0.05090 0.05080 0.05080 0.05090 0.05092 7.8784423 × 10 6.807 × 10 68.5
-4 -1
5 6.0 0.04160 0.04120 0.04110 0.04120 0.04100 0.04070 0.04010 0.04080 0.04100 0.04120 0.04099 8.1572246 × 10 7.048 × 10 70.9
-4 -1
Average 6.9047369 × 10 5.966 × 10 60.0
0.075
1 0.06 1
Flow [m³/min]
2 2
0.045
Step
Step
3 3
0.03
4 4
5 0.015 5
0
0 5 10 15 20 0 5 10 15 20 0 15 30 45 60 75
Pressure [psi] Pressure [psi] Lugeons
Wash out
Lugeon: 70.9
Hydraulic Conductivity: 8.1572246E-4 cm/s
Hydraulic Conductivity: 7.048E-1 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-4 -1
1 4.0 0.03270 0.03220 0.03230 0.03160 0.03200 0.03160 0.03180 0.03150 0.03140 0.03110 0.03182 2.4106546 × 10 2.083 × 10 15.4
-4 -1
2 8.0 0.06710 0.06650 0.06680 0.06680 0.06710 0.06710 0.06760 0.06770 0.06750 0.06820 0.06724 4.0441313 × 10 3.494 × 10 25.9
-4 -1
3 12.0 0.10050 0.10020 0.10020 0.09990 0.09990 0.10000 0.10060 0.10030 0.10000 0.10010 0.10017 4.9951654 × 10 4.316 × 10 32.0
-4 -1
4 8.0 0.09120 0.08970 0.09000 0.08950 0.09030 0.08960 0.08970 0.08960 0.08960 0.08960 0.08988 5.4058079 × 10 4.671 × 10 34.6
-4 -1
5 4.0 0.07950 0.07700 0.07320 0.07140 0.07080 0.07790 0.07790 0.07790 0.07790 0.07780 0.07613 5.7675405 × 10 4.983 × 10 36.9
-4 -1
Average 4.5246599 × 10 3.909 × 10 29.0
0.15
1 0.12 1
Flow [m³/min]
2 2
0.09
Step
Step
3 3
0.06
4 4
5 0.03 5
0
0 4 8 12 16 0 4 8 12 16 0 8 16 24 32 40
Pressure [psi] Pressure [psi] Lugeons
Wash out
Lugeon: 36.9
Hydraulic Conductivity: 5.7675405E-4 cm/s
Hydraulic Conductivity: 4.983E-1 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-4 -1
1 6.0 0.09850 0.09760 0.09750 0.09720 0.09800 0.09710 0.09700 0.09770 0.09760 0.09790 0.09761 6.8093244 × 10 5.883 × 10 44.0
-4 -1
2 12.0 0.11730 0.11600 0.11620 0.11600 0.11640 0.11610 0.11600 0.11640 0.11620 0.11760 0.11642 6.0397482 × 10 5.218 × 10 39.0
-4 -1
3 18.0 0.13790 0.13610 0.13610 0.13720 0.13810 0.13550 0.13620 0.13650 0.13650 0.13650 0.13666 5.6432549 × 10 4.876 × 10 36.4
-4 -1
4 12.0 0.12020 0.11960 0.11810 0.11950 0.11900 0.11940 0.11910 0.11940 0.11910 0.11920 0.11926 6.1870844 × 10 5.346 × 10 39.9
-4 -1
5 6.0 0.10080 0.10030 0.10010 0.09980 0.09990 0.10010 0.10050 0.10020 0.10020 0.10020 0.10021 6.9907017 × 10 6.040 × 10 45.1
-4 -1
Average 6.3340227 × 10 5.473 × 10 40.9
0.15
1 0.12 1
Flow [m³/min]
2 2
0.09
Step
Step
3 3
0.06
4 4
5 0.03 5
0
0 5 10 15 20 0 5 10 15 20 0 10 20 30 40 50
Pressure [psi] Pressure [psi] Lugeons
Turbulent
Lugeon: 39.0
Hydraulic Conductivity: 6.0397482E-4 cm/s
Hydraulic Conductivity: 5.218E-1 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-4 -1
1 3.0 0.09130 0.09120 0.09140 0.09150 0.09150 0.09150 0.09140 0.09140 0.09140 0.09140 0.09140 4.2039205 × 10 3.632 × 10 24.2
-4 -1
2 6.0 0.10190 0.10130 0.10140 0.10100 0.10140 0.10040 0.10070 0.10070 0.10070 0.10060 0.10101 3.8452539 × 10 3.322 × 10 22.1
-4 -1
3 9.0 0.11120 0.11150 0.11100 0.11100 0.11130 0.11090 0.11100 0.11100 0.11120 0.11110 0.11112 3.6082745 × 10 3.118 × 10 20.8
-4 -1
4 6.2 0.10180 0.10060 0.10100 0.10180 0.10170 0.10130 0.10190 0.10140 0.10140 0.10140 0.10143 3.8173834 × 10 3.298 × 10 22.0
-4 -1
5 3.3 0.09010 0.09020 0.09060 0.09040 0.09060 0.09040 0.09030 0.09030 0.09040 0.09040 0.09037 4.0717618 × 10 3.518 × 10 23.5
-4 -1
Average 3.9093188 × 10 3.378 × 10 22.5
0.15
1 0.12 1
Flow [m³/min]
2 2
0.09
Step
Step
3 3
0.06
4 4
5 0.03 5
0
0 2.5 5 7.5 10 0 2.5 5 7.5 10 0 6 12 18 24 30
Pressure [psi] Pressure [psi] Lugeons
Turbulent
Lugeon: 22.1
Hydraulic Conductivity: 3.8452539E-4 cm/s
Hydraulic Conductivity: 3.322E-1 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-4 -1
1 3.0 0.03580 0.03550 0.03570 0.03570 0.03590 0.03570 0.03560 0.03580 0.03580 0.03570 0.03572 1.9445291 × 10 1.680 × 10 11.5
-4 -1
2 6.0 0.07380 0.07330 0.07320 0.07480 0.07510 0.07520 0.07500 0.07530 0.07540 0.07510 0.07462 3.3620997 × 10 2.905 × 10 20.0
-4 -1
3 9.0 0.11000 0.10990 0.10860 0.10810 0.10890 0.10850 0.10850 0.10910 0.10970 0.10930 0.10906 4.1914812 × 10 3.621 × 10 24.9
-4 -1
4 6.0 0.10240 0.10280 0.10300 0.10250 0.10290 0.10200 0.10220 0.10250 0.10190 0.10230 0.10245 4.6160160 × 10 3.988 × 10 27.4
-4 -1
5 3.0 0.08700 0.08700 0.09750 0.09750 0.09740 0.09670 0.09820 0.09850 0.09890 0.09860 0.09573 5.2113597 × 10 4.503 × 10 30.9
-4 -1
Average 3.8650971 × 10 3.339 × 10 22.9
0.15
1 0.12 1
Flow [m³/min]
2 2
0.09
Step
Step
3 3
0.06
4 4
5 0.03 5
0
0 2.5 5 7.5 10 0 2.5 5 7.5 10 0 8 16 24 32 40
Pressure [psi] Pressure [psi] Lugeons
Wash out
Lugeon: 30.9
Hydraulic Conductivity: 5.2113597E-4 cm/s
Hydraulic Conductivity: 4.503E-1 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-4 -1
1 4.0 0.09500 0.09500 0.09510 0.09560 0.09470 0.09540 0.09550 0.09540 0.09560 0.09530 0.09526 4.8100483 × 10 4.156 × 10 28.7
-4 -1
2 8.0 0.11460 0.11380 0.11340 0.11350 0.11390 0.11300 0.11350 0.11350 0.11350 0.11360 0.11363 4.5805067 × 10 3.958 × 10 27.3
-4 -1
3 12.0 0.13200 0.13210 0.13250 0.13280 0.13280 0.13890 0.13550 0.13410 0.13410 0.13410 0.13389 4.4914121 × 10 3.881 × 10 26.8
-4 -1
4 8.0 0.11230 0.11240 0.11240 0.11250 0.11250 0.11260 0.11300 0.11260 0.11300 0.11240 0.11257 4.5377773 × 10 3.921 × 10 27.0
-4 -1
5 4.0 0.09330 0.09370 0.09330 0.09310 0.09400 0.09300 0.09390 0.09310 0.09390 0.09390 0.09352 4.7221889 × 10 4.080 × 10 28.1
-4 -1
Average 4.6283866 × 10 3.999 × 10 27.6
0.15
1 0.12 1
Flow [m³/min]
2 2
0.09
Step
Step
3 3
0.06
4 4
5 0.03 5
0
0 4 8 12 16 0 4 8 12 16 0 6 12 18 24 30
Pressure [psi] Pressure [psi] Lugeons
Turbulent
Lugeon: 27.3
Hydraulic Conductivity: 4.5805067E-4 cm/s
Hydraulic Conductivity: 3.958E-1 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-4 -1
1 4.0 0.04590 0.04550 0.04540 0.04540 0.04540 0.04540 0.04540 0.04530 0.04540 0.04540 0.04545 1.5024693 × 10 1.298 × 10 8.3
-4 -1
2 8.0 0.10480 0.10330 0.10430 0.10430 0.10460 0.10470 0.10380 0.10460 0.10420 0.10390 0.10425 2.7512461 × 10 2.377 × 10 15.2
-4 -1
3 12.0 0.10510 0.11520 0.11590 0.11510 0.11560 0.11550 0.11510 0.11540 0.11580 0.11580 0.11445 2.5135263 × 10 2.172 × 10 13.9
-4 -1
4 8.0 0.10450 0.10420 0.10420 0.10460 0.10430 0.10390 0.10420 0.10460 0.10450 0.10450 0.10435 2.7538852 × 10 2.379 × 10 15.2
-4 -1
5 4.0 0.04700 0.04750 0.04780 0.04710 0.04680 0.04650 0.04650 0.04590 0.04580 0.04580 0.04667 1.5427996 × 10 1.333 × 10 8.5
-4 -1
Average 2.2127853 × 10 1.912 × 10 12.2
0.15
1 0.12 1
Flow [m³/min]
2 2
0.09
Step
Step
3 3
0.06
4 4
5 0.03 5
0
0 4 8 12 16 0 4 8 12 16 0 4 8 12 16 20
Pressure [psi] Pressure [psi] Lugeons
Laminar
Lugeon: 12.2
Hydraulic Conductivity: 2.2127853E-4 cm/s
Hydraulic Conductivity: 1.912E-1 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Lithology: Caliza
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-4 -1
1 5.0 0.00840 0.00840 0.00830 0.00830 0.00820 0.00820 0.00800 0.00820 0.00810 0.00810 0.00822 1.4796959 × 10 1.278 × 10 9.4
-5 -2
2 10.0 0.00990 0.00990 0.01000 0.00990 0.01000 0.00990 0.01000 0.00990 0.00980 0.00980 0.00991 9.9517228 × 10 8.598 × 10 6.3
-5 -2
3 15.0 0.01170 0.01190 0.01190 0.01180 0.01170 0.01160 0.01160 0.01170 0.01160 0.01170 0.01172 8.1610176 × 10 7.051 × 10 5.2
-5 -2
4 10.0 0.00960 0.00950 0.00930 0.00930 0.00920 0.00920 0.00920 0.00930 0.00920 0.00920 0.00930 9.3391546 × 10 8.069 × 10 5.9
-4 -1
5 5.0 0.00650 0.00640 0.00650 0.00650 0.00650 0.00630 0.00650 0.00640 0.00640 0.00650 0.00645 1.1610753 × 10 1.003 × 10 7.4
-4 -2
Average 1.0771921 × 10 9.307 × 10 6.9
0.015
1 0.012 1
Flow [m³/min]
2 2
0.009
Step
Step
3 3
0.006
4 4
5 0.003 5
0
0 4 8 12 16 0 4 8 12 16 0 2 4 6 8 10
Pressure [psi] Pressure [psi] Lugeons
Turbulent
Lugeon: 6.3
Hydraulic Conductivity: 9.9517228E-5 cm/s
Hydraulic Conductivity: 8.598E-2 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Lithology: Caliza
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-5 -2
1 14.5 0.00470 0.00460 0.00460 0.00460 0.00450 0.00450 0.00460 0.00450 0.00450 0.00450 0.00456 2.3821024 × 10 2.058 × 10 1.4
-5 -2
2 29.0 0.00750 0.00760 0.00750 0.00750 0.00740 0.00740 0.00730 0.00730 0.00730 0.00730 0.00741 2.0233582 × 10 1.748 × 10 1.2
-5 -2
3 43.5 0.00940 0.00930 0.00930 0.00930 0.00940 0.00920 0.00920 0.00930 0.00920 0.00920 0.00928 1.7152844 × 10 1.482 × 10 1.0
-5 -2
4 29.0 0.00660 0.00670 0.00660 0.00660 0.00670 0.00650 0.00650 0.00660 0.00650 0.00650 0.00658 1.7967203 × 10 1.552 × 10 1.1
-5 -2
5 14.5 0.00410 0.00420 0.00430 0.00430 0.00420 0.00430 0.00430 0.00430 0.00430 0.00430 0.00426 2.2253852 × 10 1.923 × 10 1.3
-5 -2
Average 2.0285701 × 10 1.753 × 10 1.2
0.01
1 0.008 1
Flow [m³/min]
2 2
0.006
Step
Step
3 3
0.004
4 4
5 0.002 5
0
0 12.5 25 37.5 50 0 12.5 25 37.5 50 0 0.3 0.6 0.9 1.2 1.5
Pressure [psi] Pressure [psi] Lugeons
Turbulent
Lugeon: 1.2
Hydraulic Conductivity: 2.0233582E-5 cm/s
Hydraulic Conductivity: 1.748E-2 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Lithology: Caliza
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-5 -2
1 20.0 0.01970 0.01920 0.01960 0.01990 0.01930 0.01940 0.02000 0.01980 0.01980 0.01970 0.01964 6.5416538 × 10 5.652 × 10 3.8
-5 -2
2 40.0 0.02640 0.02620 0.02600 0.02530 0.02540 0.02510 0.02500 0.02510 0.02520 0.02520 0.02549 4.3667798 × 10 3.773 × 10 2.5
-5 -2
3 60.0 0.03110 0.03050 0.02970 0.03000 0.02940 0.02850 0.02850 0.02840 0.02840 0.02840 0.02929 3.3774560 × 10 2.918 × 10 2.0
-5 -2
4 40.0 0.01770 0.01740 0.01770 0.01740 0.01720 0.01710 0.01720 0.01740 0.01730 0.01720 0.01736 2.9740015 × 10 2.570 × 10 1.7
-5 -2
5 20.0 0.00890 0.00950 0.00890 0.00890 0.00890 0.00890 0.00900 0.00890 0.00870 0.00820 0.00888 2.9577335 × 10 2.555 × 10 1.7
-5 -2
Average 4.0435249 × 10 3.494 × 10 2.4
0.03
1 0.024 1
Flow [m³/min]
2 2
0.018
Step
Step
3 3
0.012
4 4
5 0.006 5
0
0 20 40 60 80 0 20 40 60 80 0 0.8 1.6 2.4 3.2 4
Pressure [psi] Pressure [psi] Lugeons
Void filling
Lugeon: 1.7
Hydraulic Conductivity: 2.9577335E-5 cm/s
Hydraulic Conductivity: 2.555E-2 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Lithology: Caliza
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-4 -2
1 20.0 0.01970 0.01920 0.01960 0.01990 0.01930 0.01940 0.02000 0.01980 0.01980 0.01970 0.01964 1.0212281 × 10 8.823 × 10 6.5
-5 -2
2 40.0 0.02640 0.02620 0.02600 0.02530 0.02540 0.02510 0.02500 0.02510 0.02520 0.02520 0.02549 6.8170500 × 10 5.890 × 10 4.3
-5 -2
3 60.0 0.03110 0.03050 0.02970 0.03000 0.02940 0.02850 0.02850 0.02840 0.02840 0.02840 0.02929 5.2726006 × 10 4.556 × 10 3.3
-5 -2
4 40.0 0.01770 0.01740 0.01770 0.01740 0.01720 0.01710 0.01720 0.01740 0.01730 0.01720 0.01736 4.6427614 × 10 4.011 × 10 2.9
-5 -2
5 20.0 0.00890 0.00950 0.00890 0.00890 0.00890 0.00890 0.00900 0.00890 0.00870 0.00820 0.00888 4.6173652 × 10 3.989 × 10 2.9
-5 -2
Average 6.3124116 × 10 5.454 × 10 4.0
0.03
1 0.024 1
Flow [m³/min]
2 2
0.018
Step
Step
3 3
0.012
4 4
5 0.006 5
0
0 20 40 60 80 0 20 40 60 80 0 1.5 3 4.5 6 7.5
Pressure [psi] Pressure [psi] Lugeons
Void filling
Lugeon: 2.9
Hydraulic Conductivity: 4.6173652E-5 cm/s
Hydraulic Conductivity: 3.989E-2 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Location: ----- Lugeon Test: PZN-16-01 Tested bore: PZN-16-01
Lithology: Caliza
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-4 -2
1 8.0 0.01630 0.01690 0.01690 0.01680 0.01670 0.01690 0.01670 0.01650 0.01640 0.01650 0.01666 1.0780283 × 10 9.314 × 10 7.2
-4 -2
2 16.0 0.02290 0.02270 0.02280 0.02290 0.02280 0.02280 0.02280 0.02270 0.02270 0.02280 0.02279 1.0888878 × 10 9.408 × 10 7.3
-4 -2
3 24.0 0.02910 0.02900 0.02970 0.02740 0.02850 0.02930 0.02760 0.02810 0.02830 0.02820 0.02852 1.0800949 × 10 9.332 × 10 7.2
-4 -2
4 16.0 0.02300 0.02300 0.02300 0.02290 0.02290 0.02280 0.02290 0.02280 0.02280 0.02280 0.02289 1.0936657 × 10 9.449 × 10 7.3
-4 -2
5 8.0 0.01720 0.01720 0.01730 0.01710 0.01730 0.01720 0.01710 0.01720 0.01720 0.01720 0.01720 1.1129704 × 10 9.616 × 10 7.5
-4 -2
Average 1.0907294 × 10 9.424 × 10 7.3
0.03
1 0.024 1
Flow [m³/min]
2 2
0.018
Step
Step
3 3
0.012
4 4
5 0.006 5
0
0 7.5 15 22.5 30 0 7.5 15 22.5 30 0 1.5 3 4.5 6 7.5
Pressure [psi] Pressure [psi] Lugeons
Laminar
Lugeon: 7.3
Hydraulic Conductivity: 1.0907294E-4 cm/s
Hydraulic Conductivity: 9.424E-2 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Location: ----- Lugeon Test: PZN-16-02 Tested bore: PZN-16-02
Lithology: Caliza
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-5 -2
1 2.0 0.01600 0.01580 0.01690 0.01610 0.01610 0.01690 0.01610 0.01610 0.01620 0.01510 0.01613 7.6490684 × 10 6.609 × 10 4.5
-4 -1
2 4.0 0.03540 0.03570 0.03550 0.03350 0.03370 0.03380 0.03390 0.03390 0.03380 0.03420 0.03434 1.4491740 × 10 1.252 × 10 8.6
-4 -1
3 6.0 0.06330 0.06330 0.06390 0.06370 0.06400 0.06310 0.06370 0.06340 0.06360 0.06360 0.06356 2.4162727 × 10 2.088 × 10 14.3
-4 -1
4 4.0 0.05720 0.05720 0.05720 0.05710 0.05720 0.05720 0.05730 0.05720 0.05720 0.05720 0.05720 2.4138834 × 10 2.086 × 10 14.3
-4 -1
5 2.0 0.05280 0.05300 0.05280 0.05260 0.05280 0.05280 0.05270 0.05240 0.05240 0.05260 0.05269 2.4986325 × 10 2.159 × 10 14.8
-4 -1
Average 1.9085739 × 10 1.649 × 10 11.3
0.075
1 0.06 1
Flow [m³/min]
2 2
0.045
Step
Step
3 3
0.03
4 4
5 0.015 5
0
0 2 4 6 8 0 2 4 6 8 0 3 6 9 12 15
Pressure [psi] Pressure [psi] Lugeons
Wash out
Lugeon: 14.8
Hydraulic Conductivity: 2.4986325E-4 cm/s
Hydraulic Conductivity: 2.159E-1 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Location: ----- Lugeon Test: PZN-16-03 Tested bore: PZN-16-03
Lithology: Caliza
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-4 -1
1 2.0 0.02420 0.02440 0.02420 0.02420 0.02410 0.02420 0.02420 0.02420 0.02420 0.02420 0.02421 1.9508532 × 10 1.686 × 10 12.8
-4 -1
2 4.0 0.03560 0.03430 0.03560 0.03430 0.03520 0.03450 0.03490 0.03540 0.03440 0.03470 0.03489 2.5019397 × 10 2.162 × 10 16.4
-4 -1
3 6.0 0.04790 0.04420 0.04430 0.04430 0.04430 0.04430 0.04430 0.04430 0.04440 0.04440 0.04467 2.8855833 × 10 2.493 × 10 18.9
-4 -1
4 4.0 0.03660 0.03830 0.03650 0.03760 0.03850 0.03700 0.03770 0.03770 0.03780 0.03820 0.03759 2.6955550 × 10 2.329 × 10 17.7
-4 -1
5 2.0 0.02770 0.02800 0.02740 0.02760 0.02760 0.02760 0.02750 0.02760 0.02740 0.02740 0.02758 2.2224094 × 10 1.920 × 10 14.6
-4 -1
Average 2.4512681 × 10 2.118 × 10 16.1
0.05
1 0.04 1
Flow [m³/min]
2 2
0.03
Step
Step
3 3
0.02
4 4
5 0.01 5
0
0 2 4 6 8 0 2 4 6 8 0 4 8 12 16 20
Pressure [psi] Pressure [psi] Lugeons
Dilation
Lugeon: 12.8
Hydraulic Conductivity: 1.9508532E-4 cm/s
Hydraulic Conductivity: 1.686E-1 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Location: ----- Lugeon Test: PZN-16-04 Tested bore: PZN-16-04
Lithology: Caliza
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-4 -2
1 3.2 0.02370 0.02440 0.02610 0.02460 0.02490 0.02590 0.02510 0.02490 0.02610 0.02460 0.02503 1.1507241 × 10 9.942 × 10 6.9
-4 -1
2 6.4 0.04260 0.04290 0.04340 0.04500 0.04380 0.04370 0.04280 0.04380 0.04370 0.04340 0.04351 1.6890913 × 10 1.459 × 10 10.1
-4 -1
3 9.1 0.05690 0.05660 0.05650 0.05520 0.05640 0.05610 0.05570 0.05650 0.05640 0.05630 0.05626 1.9306085 × 10 1.668 × 10 11.5
-4 -1
4 6.0 0.04560 0.04630 0.04600 0.04550 0.04460 0.04620 0.04580 0.04520 0.04580 0.04590 0.04569 1.8089013 × 10 1.563 × 10 10.8
-4 -1
5 3.0 0.03090 0.03180 0.03140 0.03230 0.03080 0.03130 0.03170 0.03150 0.03120 0.03120 0.03141 1.4608604 × 10 1.262 × 10 8.7
-4 -1
Average 1.6080371 × 10 1.389 × 10 9.6
0.075
1 0.06 1
Flow [m³/min]
2 2
0.045
Step
Step
3 3
0.03
4 4
5 0.015 5
0
0 2.5 5 7.5 10 0 2.5 5 7.5 10 0 3 6 9 12 15
Pressure [psi] Pressure [psi] Lugeons
Dilation
Lugeon: 6.9
Hydraulic Conductivity: 1.1507241E-4 cm/s
Hydraulic Conductivity: 9.942E-2 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Location: ----- Lugeon Test: PZN-17-01 Tested bore: PZN-17-01
Lithology: Caliza/arenisca
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-5 -2
1 3.5 0.02100 0.02100 0.02100 0.02100 0.02100 0.02100 0.02100 0.02100 0.02100 0.02100 0.02100 2.9014484 × 10 2.507 × 10 1.8
-5 -2
2 6.5 0.02750 0.02750 0.02750 0.02800 0.02800 0.02800 0.02800 0.02800 0.02800 0.02800 0.02785 3.6944282 × 10 3.192 × 10 2.3
-5 -2
3 8.5 0.03700 0.03700 0.03700 0.03700 0.03700 0.03700 0.03700 0.03700 0.03700 0.03700 0.03700 4.7811098 × 10 4.131 × 10 3.0
-5 -2
4 6.5 0.02500 0.02500 0.02500 0.02500 0.02500 0.02500 0.02500 0.02500 0.02500 0.02500 0.02500 3.3163628 × 10 2.865 × 10 2.1
-5 -2
5 3.5 0.01900 0.01900 0.01900 0.01900 0.01900 0.01900 0.01900 0.01900 0.01900 0.01900 0.01900 2.6251200 × 10 2.268 × 10 1.6
-5 -2
Average 3.4636939 × 10 2.993 × 10 2.2
0.04
1 0.032 1
Flow [m³/min]
2 2
0.024
Step
Step
3 3
0.016
4 4
5 0.008 5
0
0 2.5 5 7.5 10 0 2.5 5 7.5 10 0 0.6 1.2 1.8 2.4 3
Pressure [psi] Pressure [psi] Lugeons
Dilation
Lugeon: 1.8
Hydraulic Conductivity: 2.9014484E-5 cm/s
Hydraulic Conductivity: 2.507E-2 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Location: ----- Lugeon Test: PZN-18-01 Tested bore: PZN-18-01
Lithology: Caliza
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-6 -3
1 6.0 0.00040 0.00040 0.00050 0.00050 0.00040 0.00040 0.00040 0.00040 0.00050 0.00040 0.00043 3.8170717 × 10 3.298 × 10 0.2
-6 -3
2 12.0 0.00050 0.00050 0.00050 0.00050 0.00060 0.00060 0.00060 0.00060 0.00060 0.00060 0.00056 3.3772382 × 10 2.918 × 10 0.2
-6 -3
3 18.0 0.00060 0.00060 0.00060 0.00060 0.00060 0.00060 0.00060 0.00050 0.00050 0.00050 0.00057 2.6029760 × 10 2.249 × 10 0.2
-6 -3
4 12.0 0.00060 0.00060 0.00060 0.00050 0.00050 0.00040 0.00030 0.00030 0.00030 0.00040 0.00045 2.7138521 × 10 2.345 × 10 0.2
-6 -3
5 6.0 0.00040 0.00040 0.00040 0.00020 0.00030 0.00030 0.00040 0.00040 0.00040 0.00040 0.00036 3.1956879 × 10 2.761 × 10 0.2
-6 -3
Average 3.1413652 × 10 2.714 × 10 0.2
0.00075
1 0.0006 1
Flow [m³/min]
2 2
0.00045
Step
Step
3 3
0.0003
4 4
5 0.00015 5
0
0 5 10 15 20 0 5 10 15 20 0 0.1 0.1 0.2 0.2 0.3
Pressure [psi] Pressure [psi] Lugeons
Turbulent
Lugeon: 0.2
Hydraulic Conductivity: 3.3772382E-6 cm/s
Hydraulic Conductivity: 2.918E-3 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Lithology: Caliza
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-6 -3
1 12.0 0.00100 0.00100 0.00100 0.00100 0.00100 0.00100 0.00100 0.00100 0.00100 0.00100 0.00100 2.7700684 × 10 2.393 × 10 0.2
-6 -3
2 24.0 0.00170 0.00170 0.00170 0.00170 0.00150 0.00150 0.00150 0.00150 0.00150 0.00150 0.00158 3.0505521 × 10 2.636 × 10 0.2
-6 -3
3 36.0 0.00220 0.00210 0.00220 0.00220 0.00220 0.00220 0.00220 0.00210 0.00210 0.00220 0.00217 3.2154048 × 10 2.778 × 10 0.2
-6 -3
4 24.0 0.00180 0.00180 0.00180 0.00180 0.00180 0.00180 0.00180 0.00180 0.00180 0.00180 0.00180 3.4753125 × 10 3.003 × 10 0.2
-6 -3
5 14.0 0.00170 0.00170 0.00170 0.00170 0.00170 0.00160 0.00160 0.00160 0.00160 0.00160 0.00165 4.2618248 × 10 3.682 × 10 0.3
-6 -3
Average 3.3546325 × 10 2.898 × 10 0.2
0.003
1 0.0024 1
Flow [m³/min]
2 2
0.0018
Step
Step
3 3
0.0012
4 4
5 0.0006 5
0
0 10 20 30 40 0 10 20 30 40 0 0.1 0.1 0.2 0.2 0.3
Pressure [psi] Pressure [psi] Lugeons
Wash out
Lugeon: 0.3
Hydraulic Conductivity: 4.2618248E-6 cm/s
Hydraulic Conductivity: 3.682E-3 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Lithology: Caliza
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-6 -3
1 15.0 0.00070 0.00070 0.00070 0.00070 0.00070 0.00070 0.00070 0.00070 0.00070 0.00070 0.00070 1.4036914 × 10 1.213 × 10 0.1
-6 -4
2 34.0 0.00090 0.00090 0.00090 0.00090 0.00090 0.00090 0.00090 0.00090 0.00090 0.00090 0.00090 1.1553592 × 10 9.982 × 10 0.1
-6 -4
3 45.0 0.00100 0.00100 0.00100 0.00100 0.00100 0.00100 0.00100 0.00100 0.00100 0.00100 0.00100 1.0624129 × 10 9.179 × 10 0.1
-7 -4
4 34.0 0.00070 0.00070 0.00070 0.00070 0.00070 0.00070 0.00070 0.00070 0.00070 0.00070 0.00070 8.9861271 × 10 7.764 × 10 0.1
-7 -4
5 15.0 0.00040 0.00040 0.00040 0.00040 0.00040 0.00040 0.00040 0.00040 0.00040 0.00040 0.00040 8.0210937 × 10 6.930 × 10 0.0
-6 -4
Average 1.0644371 × 10 9.197 × 10 0.1
0.0015
1 0.0012 1
Flow [m³/min]
2 2
0.0009
Step
Step
3 3
0.0006
4 4
5 0.0003 5
0
0 12.5 25 37.5 50 0 12.5 25 37.5 50 0 0.0 0.0 0.1 0.1 0.1
Pressure [psi] Pressure [psi] Lugeons
Void filling
Lugeon: 0.0
Hydraulic Conductivity: 8.0210937E-7 cm/s
Hydraulic Conductivity: 6.930E-4 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Location: ----- Lugeon Test: PZN-19-01 Tested bore: PZN-19-01
Lithology: Caliza
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-5 -2
1 5.0 0.00070 0.00070 0.00070 0.00070 0.00070 0.00070 0.00070 0.00070 0.00070 0.00070 0.00070 1.2510328 × 10 1.081 × 10 0.8
-5 -3
2 10.0 0.00100 0.00100 0.00100 0.00100 0.00100 0.00100 0.00100 0.00100 0.00100 0.00100 0.00100 1.0558691 × 10 9.123 × 10 0.7
-5 -2
3 15.0 0.00180 0.00180 0.00180 0.00180 0.00180 0.00180 0.00180 0.00180 0.00180 0.00180 0.00180 1.3486817 × 10 1.165 × 10 0.9
-5 -2
4 10.0 0.00110 0.00110 0.00110 0.00110 0.00110 0.00110 0.00110 0.00110 0.00110 0.00110 0.00110 1.1614560 × 10 1.003 × 10 0.8
-5 -2
5 5.0 0.00080 0.00080 0.00080 0.00080 0.00080 0.00080 0.00080 0.00080 0.00080 0.00080 0.00080 1.4297518 × 10 1.235 × 10 0.9
-5 -2
Average 1.2493583 × 10 1.079 × 10 0.8
0.002
1 0.0016 1
Flow [m³/min]
2 2
0.0012
Step
Step
3 3
0.0008
4 4
5 0.0004 5
0
0 4 8 12 16 0 4 8 12 16 0 0.2 0.4 0.6 0.8 1
Pressure [psi] Pressure [psi] Lugeons
Laminar
Lugeon: 0.8
Hydraulic Conductivity: 1.2493583E-5 cm/s
Hydraulic Conductivity: 1.079E-2 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Location: ----- Lugeon Test: PZN-19-02 Tested bore: PZN-19-02
Lithology: Lutitas/arenisca
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-6 -3
1 5.0 0.00110 0.00110 0.00110 0.00110 0.00110 0.00110 0.00110 0.00110 0.00110 0.00110 0.00110 7.8513194 × 10 6.784 × 10 0.4
-6 -3
2 12.0 0.00150 0.00150 0.00150 0.00150 0.00150 0.00150 0.00150 0.00150 0.00150 0.00150 0.00150 5.3661451 × 10 4.636 × 10 0.3
-6 -3
3 22.0 0.00160 0.00160 0.00160 0.00160 0.00160 0.00160 0.00160 0.00160 0.00160 0.00160 0.00160 3.3423096 × 10 2.888 × 10 0.2
-6 -3
4 12.0 0.00140 0.00140 0.00140 0.00140 0.00140 0.00140 0.00140 0.00140 0.00140 0.00140 0.00140 5.0084021 × 10 4.327 × 10 0.3
-6 -3
5 5.0 0.00090 0.00090 0.00090 0.00090 0.00090 0.00090 0.00090 0.00090 0.00090 0.00090 0.00090 6.4238068 × 10 5.550 × 10 0.4
-6 -3
Average 5.5983966 × 10 4.837 × 10 0.3
0.002
1 0.0016 1
Flow [m³/min]
2 2
0.0012
Step
Step
3 3
0.0008
4 4
5 0.0004 5
0
0 7.5 15 22.5 30 0 7.5 15 22.5 30 0 0.1 0.2 0.3 0.4 0.5
Pressure [psi] Pressure [psi] Lugeons
Turbulent
Lugeon: 0.3
Hydraulic Conductivity: 5.3661451E-6 cm/s
Hydraulic Conductivity: 4.636E-3 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Lithology: Caliza
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-4 -2
1 4.0 0.00850 0.00850 0.00840 0.00830 0.00800 0.00800 0.00760 0.00760 0.00760 0.00750 0.00800 1.0182325 × 10 8.798 × 10 6.3
-5 -2
2 8.0 0.01180 0.01160 0.01160 0.01160 0.01130 0.01100 0.01100 0.01080 0.01000 0.01000 0.01107 9.3413123 × 10 8.071 × 10 5.8
-5 -2
3 12.0 0.01400 0.01400 0.01350 0.01350 0.01350 0.01340 0.01340 0.01340 0.01340 0.01340 0.01355 8.5519092 × 10 7.389 × 10 5.3
-5 -2
4 8.0 0.00950 0.00950 0.00950 0.00930 0.00930 0.00920 0.00920 0.00920 0.00920 0.00920 0.00931 7.8561533 × 10 6.788 × 10 4.9
-5 -2
5 4.0 0.00600 0.00600 0.00600 0.00600 0.00600 0.00600 0.00600 0.00600 0.00600 0.00600 0.00600 7.6367439 × 10 6.598 × 10 4.7
-5 -2
Average 8.7136888 × 10 7.529 × 10 5.4
0.015
1 0.012 1
Flow [m³/min]
2 2
0.009
Step
Step
3 3
0.006
4 4
5 0.003 5
0
0 4 8 12 16 0 4 8 12 16 0 1.5 3 4.5 6 7.5
Pressure [psi] Pressure [psi] Lugeons
Void filling
Lugeon: 4.7
Hydraulic Conductivity: 7.6367439E-5 cm/s
Hydraulic Conductivity: 6.598E-2 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Lithology: Caliza
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-5 -2
1 6.0 0.00600 0.00600 0.00600 0.00600 0.00600 0.00600 0.00600 0.00600 0.00600 0.00600 0.00600 3.9109777 × 10 3.379 × 10 2.2
-5 -2
2 12.0 0.00910 0.00910 0.00910 0.00910 0.00910 0.00910 0.00910 0.00910 0.00910 0.00910 0.00910 3.6889024 × 10 3.187 × 10 2.1
-5 -2
3 22.0 0.01210 0.01210 0.01210 0.01210 0.01210 0.01210 0.01210 0.01210 0.01210 0.01210 0.01210 3.0089146 × 10 2.600 × 10 1.7
-5 -2
4 12.0 0.00620 0.00620 0.00620 0.00620 0.00620 0.00620 0.00620 0.00620 0.00620 0.00620 0.00620 2.5133181 × 10 2.172 × 10 1.4
-5 -2
5 6.0 0.00340 0.00340 0.00340 0.00340 0.00340 0.00340 0.00340 0.00340 0.00340 0.00340 0.00340 2.2162207 × 10 1.915 × 10 1.3
-5 -2
Average 3.0676667 × 10 2.650 × 10 1.8
0.015
1 0.012 1
Flow [m³/min]
2 2
0.009
Step
Step
3 3
0.006
4 4
5 0.003 5
0
0 7.5 15 22.5 30 0 7.5 15 22.5 30 0 0.6 1.2 1.8 2.4 3
Pressure [psi] Pressure [psi] Lugeons
Void filling
Lugeon: 1.3
Hydraulic Conductivity: 2.2162207E-5 cm/s
Hydraulic Conductivity: 1.915E-2 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Lithology: Caliza
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-5 -2
1 5.0 0.01200 0.01200 0.01200 0.01200 0.01200 0.01200 0.01200 0.01200 0.01200 0.01200 0.01200 6.3398462 × 10 5.478 × 10 3.8
-5 -2
2 12.0 0.02300 0.02300 0.02300 0.02300 0.02300 0.02300 0.02300 0.02300 0.02300 0.02300 0.02300 8.3560767 × 10 7.220 × 10 5.0
-5 -2
3 19.0 0.03600 0.03600 0.03600 0.03600 0.03600 0.03600 0.03600 0.03600 0.03600 0.03600 0.03600 9.9662659 × 10 8.611 × 10 6.0
-5 -2
4 12.0 0.02400 0.02400 0.02400 0.02400 0.02400 0.02400 0.02400 0.02400 0.02400 0.02400 0.02400 8.7193844 × 10 7.534 × 10 5.2
-5 -2
5 5.0 0.01400 0.01400 0.01400 0.01400 0.01400 0.01400 0.01400 0.01400 0.01400 0.01400 0.01400 7.3964872 × 10 6.391 × 10 4.4
-5 -2
Average 8.1556121 × 10 7.046 × 10 4.9
0.04
1 0.032 1
Flow [m³/min]
2 2
0.024
Step
Step
3 3
0.016
4 4
5 0.008 5
0
0 5 10 15 20 0 5 10 15 20 0 1.5 3 4.5 6 7.5
Pressure [psi] Pressure [psi] Lugeons
Dilation
Lugeon: 3.8
Hydraulic Conductivity: 6.3398462E-5 cm/s
Hydraulic Conductivity: 5.478E-2 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Lithology: Caliza
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-4 -1
1 15.0 0.01200 0.01200 0.01200 0.01200 0.01200 0.01200 0.01200 0.01200 0.01200 0.01200 0.01200 2.4105949 × 10 2.083 × 10 20.0
-4 -1
2 30.0 0.02100 0.02100 0.02100 0.02100 0.02100 0.02100 0.02100 0.02100 0.02100 0.02300 0.02120 2.3070264 × 10 1.993 × 10 19.2
-4 -1
3 45.0 0.02550 0.02550 0.02550 0.02550 0.02550 0.02550 0.02550 0.02550 0.02550 0.02550 0.02550 1.9028981 × 10 1.644 × 10 15.8
-4 -1
4 30.0 0.02100 0.02100 0.02100 0.02100 0.02100 0.02100 0.02100 0.02100 0.02100 0.02100 0.02100 2.2852620 × 10 1.974 × 10 19.0
-4 -1
5 15.0 0.01100 0.01100 0.01100 0.01100 0.01100 0.01100 0.01100 0.01100 0.01100 0.01100 0.01100 2.2097120 × 10 1.909 × 10 18.4
-4 -1
Average 2.2230987 × 10 1.921 × 10 18.5
0.03
1 0.024 1
Flow [m³/min]
2 2
0.018
Step
Step
3 3
0.012
4 4
5 0.006 5
0
0 12.5 25 37.5 50 0 12.5 25 37.5 50 0 6 12 18 24 30
Pressure [psi] Pressure [psi] Lugeons
Laminar
Lugeon: 18.5
Hydraulic Conductivity: 2.2230987E-4 cm/s
Hydraulic Conductivity: 1.921E-1 m/d
Lugeon Test Analysis Report
Project: -----
Number: -----
Client: -----
Location: ----- Lugeon Test: PZN-22-01 Tested bore: PZN-22-01
Lithology: Caliza
Step Pressure [psi] Flow Meter Readings [m³/min] Average Flow Rate [m³/min] Hydraulic Conductivity
1 2 3 4 5 6 7 8 9 10 [cm/s] [m/d] Lugeon
-5 -3
1 12.0 0.00570 0.00520 0.00570 0.00560 0.00550 0.00530 0.00560 0.00540 0.00550 0.00560 0.00551 1.0293127 × 10 8.893 × 10 0.7
-5 -2
2 25.0 0.00770 0.00660 0.00770 0.00760 0.00760 0.00750 0.00760 0.00770 0.00770 0.00760 0.00753 1.1802260 × 10 1.020 × 10 0.8
-5 -2
3 35.0 0.00990 0.00980 0.00970 0.00980 0.00970 0.00980 0.00970 0.00980 0.00970 0.00970 0.00976 1.3611950 × 10 1.176 × 10 0.9
-5 -3
4 25.0 0.00640 0.00660 0.00660 0.00660 0.00660 0.00660 0.00670 0.00660 0.00670 0.00650 0.00659 1.0328937 × 10 8.924 × 10 0.7
-6 -3
5 12.0 0.00450 0.00450 0.00450 0.00450 0.00450 0.00450 0.00450 0.00450 0.00450 0.00450 0.00450 8.4063647 × 10 7.263 × 10 0.5
-5 -3
Average 1.0888527 × 10 9.408 × 10 0.7
0.01
1 0.008 1
Flow [m³/min]
2 2
0.006
Step
Step
3 3
0.004
4 4
5 0.002 5
0
0 10 20 30 40 0 10 20 30 40 0 0.2 0.4 0.6 0.8 1
Pressure [psi] Pressure [psi] Lugeons
Dilation
Lugeon: 0.7
Hydraulic Conductivity: 1.0293127E-5 cm/s
Hydraulic Conductivity: 8.893E-3 m/d
ANEXO A.2
RESULTADOS DE ENSAYOS SLUG
TEST
1.
Displacement (m)
0.1
0. 400. 800. 1.2E+3 1.6E+3 2.0E+3
Time (min)
PROJECT INFORMATION
Company: ---
Client: ---
Project: ---
Location: ---
Test Well: Sulg recuperación PZN-04
AQUIFER DATA
Saturated Thickness: 56.6 m Anisotropy Ratio (Kz/Kr): 1.
SOLUTION
Aquifer Model: Confined Solution Method: Hvorslev
K = 0.0001339 m/day y0 = 0.7526 m
1.
0.1
Displacement (m)
0.01
0.001
0. 4. 8. 12. 16. 20.
Time (min)
PROJECT INFORMATION
Company: ----
Client: ---
Project: ---
Test Well: Slug descenso PZN-08
AQUIFER DATA
Saturated Thickness: 76.87 m Anisotropy Ratio (Kz/Kr): 1.
SOLUTION
Aquifer Model: Confined Solution Method: Hvorslev
K = 0.004761 m/day y0 = 0.03352 m
0.3
0.24
Displacement (m)
0.18
0.12
0.06
0.
0. 4. 8. 12. 16. 20.
Time (min)
PROJECT INFORMATION
Company: ---
Client: ---
Project: ---
Test Well: Slug Descenso PZN-09
AQUIFER DATA
Saturated Thickness: 71.3 m
SOLUTION
Aquifer Model: Confined Solution Method: KGS Model w/skin
Kr = 0.0002071 m/day Ss = 4.209E-5 m-1
Kz/Kr = 1. Kr' = 5.964E-5 m/day
Ss' = 1. m-1 Kz/Kr' = 0.02116
0.8
0.64
Displacement (m)
0.48
0.32
0.16
0.
0.01 0.1 1. 10. 100.
Time (min)
PROJECT INFORMATION
Company: ---
Client: ---
Project: ---
Test Well: Slug descenso PZN-11
AQUIFER DATA
Saturated Thickness: 146.2 m
SOLUTION
Aquifer Model: Confined Solution Method: KGS Model w/skin
Kr = 0.007648 m/day Ss = 5.583E-6 m-1
Kz/Kr = 1. Kr' = 0.04613 m/day
Ss' = 0.000241 m-1 Kz/Kr' = 1.
0.7
0.556
Displacement (m)
0.412
0.268
0.124
-0.02
0.01 0.1 1. 10.
Time (min)
PROJECT INFORMATION
Company: ---
Client: ---
Project: ---
Location: ---
Test Well: Slug Descenso PZN-12
AQUIFER DATA
Saturated Thickness: 180.1 m
SOLUTION
Aquifer Model: Confined Solution Method: KGS Model
Kr = 0.06422 m/day Ss = 2.066E-5 m-1
Kz/Kr = 1.
2.
1.6
Displacement (m)
1.2
0.8
0.4
0.
0.01 0.1 1. 10.
Time (min)
PROJECT INFORMATION
Company: ---
Client: ---
Project: ---
Location: ---
Test Well: Slug descenso PZN-13
Test Date: 14-12-17
AQUIFER DATA
Saturated Thickness: 196.7 m
SOLUTION
Aquifer Model: Confined Solution Method: KGS Model w/skin
Kr = 0.03889 m/day Ss = 8.734E-5 m-1
Kz/Kr = 1. Kr' = 0.02259 m/day
Ss' = 4.416E-5 m-1 Kz/Kr' = 0.001
1.
0.72
Displacement (m)
0.44
0.16
-0.12
-0.4
0.01 0.1 1. 10.
Time (min)
PROJECT INFORMATION
Company: ---
Client: ---
Project: ---
Location: ---
Test Well: Descenso slug PZN-16
Test Date: 14-12-17
AQUIFER DATA
Saturated Thickness: 187.6 m Anisotropy Ratio (Kz/Kr): 0.01122
SOLUTION
Aquifer Model: Confined Solution Method: Butler-Zhan
Kr = 0.239 m/day Ss = 0.0005332 m-1
Kz/Kr = 0.01122 Le = 81.69 m
Le(o) = 29.5 m
0.8
0.64
Displacement (m)
0.48
0.32
0.16
0.
0.01 0.1 1. 10. 100.
Time (min)
PROJECT INFORMATION
Company: ---
Client: ---
Project: ---
Location: ---
Test Well: Slug Descenso PZN-21
AQUIFER DATA
Saturated Thickness: 25.57 m
SOLUTION
Aquifer Model: Confined Solution Method: KGS Model
Kr = 0.009182 m/day Ss = 0.0001113 m-1
Kz/Kr = 1.
0.5
0.4
Displacement (m)
0.3
0.2
0.1
0.
0.01 0.1 1.
Time (min)
PROJECT INFORMATION
Company: ---
Client: ---
Project: ---
Location: ---
Test Well: Slug Descenso PZN-23
AQUIFER DATA
Saturated Thickness: 8.785 m
SOLUTION
Aquifer Model: Confined Solution Method: KGS Model
Kr = 2.156 m/day Ss = 0.002169 m-1
Kz/Kr = 1.
0.5
0.399
Displacement (m)
0.297
0.196
0.0944
-0.007
0.01 0.1 1. 10. 100.
Time (min)
PROJECT INFORMATION
Company: ---
Client: ---
Project: ---
Location: ---
Test Well: Slug Descenso PZN-24
Test Date: 16/07/2018
AQUIFER DATA
Saturated Thickness: 50. m
SOLUTION
Aquifer Model: Unconfined Solution Method: KGS Model w/skin
Kr = 0.0019 m/day Ss = 2.5E-5 m-1
Kz/Kr = 1. Kr' = 0.01399 m/day
Ss' = 0.001 m-1 Kz/Kr' = 1.
1.
Displacement (m)
0.1
0.01
0. 180. 360. 540. 720. 900.
Time (min)
PROJECT INFORMATION
Company: ---
Client: ---
Project: ---
Location: ---
Test Well: Slug recuperación PZN-04
AQUIFER DATA
Saturated Thickness: 56.9 m Anisotropy Ratio (Kz/Kr): 1.
SOLUTION
Aquifer Model: Confined Solution Method: Hvorslev
K = 0.000193 m/day y0 = 0.5481 m
1.
Displacement (m)
0.1
0.01
0. 2.4 4.8 7.2 9.6 12.
Time (min)
PROJECT INFORMATION
Company: ---
Client: ---
Project: ---
Test Well: Slug recuperación PZN-08
AQUIFER DATA
Saturated Thickness: 76.87 m Anisotropy Ratio (Kz/Kr): 1.
SOLUTION
Aquifer Model: Confined Solution Method: Hvorslev
K = 0.001059 m/day y0 = 0.05099 m
0.3
0.24
Transformed Displacement (m)
0.18
0.12
0.06
0.
0. 4. 8. 12. 16. 20.
Time (min)
PROJECT INFORMATION
Company: ---
Client: ---
Project: ---
Test Well: Slug recuperación PZN-09
AQUIFER DATA
Saturated Thickness: 71.3 m
SOLUTION
Aquifer Model: Confined Solution Method: KGS Model w/skin
Kr = 0.0002849 m/day Ss = 1.236E-11 m-1
Kz/Kr = 1. Kr' = 0.03759 m/day
Ss' = 1.215E-5 m-1 Kz/Kr' = 0.001
0.3
0.24
Displacement (m)
0.18
0.12
0.06
0.
0.01 0.1 1. 10. 100.
Time (min)
PROJECT INFORMATION
Company: ---
Client: ---
Project: ---
Test Well: Slug recuperación PZN-11
AQUIFER DATA
Saturated Thickness: 146.2 m
SOLUTION
Aquifer Model: Unconfined Solution Method: KGS Model w/skin
Kr = 0.00438 m/day Ss = 0.0006838 m-1
Kz/Kr = 1. Kr' = 0.05881 m/day
Ss' = 0.0001833 m-1 Kz/Kr' = 1.
0.5
0.4
Displacement (m)
0.3
0.2
0.1
0.
0.01 0.1 1. 10.
Time (min)
PROJECT INFORMATION
Company: ---
Client: ---
Project: ---
Location: ---
Test Well: Slug Recuperación PZN-12
Test Date: 13/12/2017
AQUIFER DATA
Saturated Thickness: 180.1 m
SOLUTION
Aquifer Model: Confined Solution Method: KGS Model w/skin
Kr = 0.001411 m/day Ss = 0.01156 m-1
Kz/Kr = 1. Kr' = 0.07948 m/day
Ss' = 1.259E-6 m-1 Kz/Kr' = 0.001
0.9
0.72
Displacement (m)
0.54
0.36
0.18
0.
0.01 0.1 1. 10.
Time (min)
PROJECT INFORMATION
Company: ---
Client: ---
Project: ---
Location: ---
Test Well: Slug recuperación PZN-13
Test Date: 14-12-17
AQUIFER DATA
Saturated Thickness: 196.7 m
SOLUTION
Aquifer Model: Confined Solution Method: KGS Model
Kr = 0.03259 m/day Ss = 4.085E-8 m-1
Kz/Kr = 1.
1.
0.72
Displacement (m)
0.44
0.16
-0.12
-0.4
0.01 0.1 1. 10.
Time (min)
PROJECT INFORMATION
Company: ---
Client: ---
Project: ---
Location: ---
Test Well: RECUPERACIÓN MLLP17-06
Test Date: 14-12-17
AQUIFER DATA
Saturated Thickness: 187.6 m Anisotropy Ratio (Kz/Kr): 1.
SOLUTION
Aquifer Model: Confined Solution Method: Butler-Zhan
Kr = 0.2078 m/day Ss = 0.0005332 m-1
Kz/Kr = 1. Le = 93.18 m
Le(o) = 29.5 m
0.9
0.72
Displacement (m)
0.54
0.36
0.18
0.
0.01 0.1 1. 10. 100.
Time (min)
PROJECT INFORMATION
Company: ---
Client: ---
Project: ---
Location: ---
Test Well: Slug Recuperación PZN -21
AQUIFER DATA
Saturated Thickness: 25.57 m
SOLUTION
Aquifer Model: Confined Solution Method: KGS Model
Kr = 0.009265 m/day Ss = 0.0006626 m-1
Kz/Kr = 1.
0.4
0.32
Displacement (m)
0.24
0.16
0.08
0.
0.01 0.1 1. 10.
Time (min)
PROJECT INFORMATION
Company: ---
Client: ---
Project: ---
Location: ---
Test Well: Slug Recuperación PZN-22
AQUIFER DATA
Saturated Thickness: 25.97 m
SOLUTION
Aquifer Model: Confined Solution Method: KGS Model
Kr = 0.5861 m/day Ss = 3.851E-5 m-1
Kz/Kr = 1.
0.6
0.48
Displacement (m)
0.36
0.24
0.12
0.
0.01 0.1 1. 10. 100.
Time (min)
PROJECT INFORMATION
Company: ---
Client: ---
Project: ---
Test Well: Slug Recuperación PZN-24
Test Date: 16/07/2018
AQUIFER DATA
Saturated Thickness: 50. m
SOLUTION
Aquifer Model: Unconfined Solution Method: KGS Model w/skin
Kr = 0.001639 m/day Ss = 2.5E-5 m-1
Kz/Kr = 1. Kr' = 0.009267 m/day
Ss' = 0.001 m-1 Kz/Kr' = 1.