CRITERIOS DE DISEÑO
POBLACIÓN DE PROYECTO
Df = 104.0 l/hab/dia
Df = 104.0 l/hab/dia
CAUDALES DE DISEÑO - SISTEMA DE AGUA POTABLE ACHUMA
Qm = 0.263 l/s
ADUCCIÓN
DATOS INICIALES:
SUMATORIA DE LONGITUDES
DE A PROGRESIVA LONGITUD COTA TUBERIA
m m.s.n.m
1 POZO E1 0.00 37.07 1,921.00
2 E1 E2 37.07 22.22 1,920.50
3 E2 E3 73.07 36.00 1,920.00
4 E3 E4 173.07 100.00 1,920.00
5 E4 E5 273.07 100.00 1,920.00
6 E5 E6 373.07 100.00 1,920.00
7 E6 C1 413.07 40.00 1,920.00
8 C1 BPA 433.07 20.00 3,146.72
9 BPA E7 473.07 40.00 3,144.22
10 E7 E8 573.07 100.00 3,141.26
11 E8 E9 673.07 100.00 3,140.54
12 E9 E10 773.07 100.00 3,135.83
13 E10 E11 873.07 100.00 3,140.74
14 E11 E12 973.07 100.00 3,140.90
15 E12 E13 1,073.07 100.00 3,138.79
16 E13 E14 1,173.07 100.00 3,131.72
17 E14 C2 1,253.07 80.00 3,124.42
18 C2 E15 1,273.07 20.00 3,123.56
19 E15 E16 1,373.07 100.00 3,123.76
20 E16 E17 1,473.07 100.00 3,133.50
21 E17 TANQUE 1,493.07 20.00 3,135.81
TOTAL LT = 1,515.29 m
RED DE DISTRIBUCION
DATOS INICIALES:
FACTOR DE CÁLCULO:
FC = Q/Nº CONEX l/s/CONEX
FC = 0.024 l/s/conex consumo promedio en cada conexión
RAMAL 2
DATOS INICIALES:
Caudal de diseño: Qd = 0.87 l/s
Tubería PVC C = 140 HASSEN WILLIANS
FACTOR DE CÁLCULO:
FC = Q/Nº CONEX l/s/CONEX