Pombo
Pombo
Pombo
INFORMACIÓN DE PRODUCTO,
SERVICE E INSTALACIÓN
ROOFTOP R410A
Capacidad Nominal 6 TR a 20TR
Calefacción por bomba
MCCH-R072N1--ACA
MCCH-R100N1--ACA
MCCH-R120N1--ACA
MCCH-R140N1--ACA
MCCH-R180N1--ACA
MCCH-R240N1--ACA
midea.com.ar
ÍNDICE
Presentación del Producto .............................................................................................................................................3
Apariencia Externa..........................................................................................................................................................3
Nomenclatura .................................................................................................................................................................4
Características..................................................................................................................................................................4
..............................................................................................................................................................7
Planos de Dimensiones..................................................................................................................................................10
Diagramas del Cableado ...............................................................................................................................................14
Datos de Desempeño....................................................................................................................................................20
Datos Eléctricos..............................................................................................................................................................32
Datos de Desempeño del Ventilador...........................................................................................................................32
.............................................................................................................................38
Diagrama del Ciclo del Refrigerante
Límite de Operación.....................................................................................................................................................40
Instalación.......................................................................................................................................................................41
Control Remoto con Cable..........................................................................................................................................44
Código de Error..............................................................................................................................................................49
Mantenimiento y Cuidado ..........................................................................................................................................59
Apéndice........................................................................................................................................................................60
2 MCCH-R072-240N1
PRESENTACIÓN DEL PRODUCTO
Capacidad de enfriamiento Modelo
Refrigerante Suministro de energía
nominal Nombre de Modelo Función
6TR MCCH-R072N1--ACA
MCCH-R100N1--ACA
10TR MCCH-R120N1--ACA
Bomba de calor R410A 380-41 Ph 50Hz
12TR MCCH-R140N1--ACA
15TR MCCH-R180N1--ACA
20TR MCCH-R240N1--ACA
APARIENCIA EXTERNA
6 / 8,5 TR 10 / 12 TR
15 TR 20 TR
3
NOMENCLATURA
M C C H -R 2 4 0 N 1 - - A C A
A: Versión de diseño
C: Descarga lateral
A:
No utilizados
Tensión: 380-3-50
H:
C:
Rooftop Midea
CARACTERÍSTICAS
galvanizada es de 275g/m2.
4 MCCH-R072-240N1
Nuevo diseño del conducto del ventilador 3.2 Fácil instalación y servicio
de intercambio de calor.
traslado.
Se puede seleccionar el techo o piso para la insta-
lación.
Polea ajustable
-
amiento de la polea montada en el eje de trans-
-
ero / reinicia el compresor y este
demorará tres minutos en
funcionar; cuando la tempera-
Puertas de acceso muy accesibles
El instalador no necesita ingresar por la puerta. Sola-
compresor se iniciará luego de una demora de siete mente por fuera de las puertas.
minutos.
del sistema para mantenimiento y servicio.
el cual tiene dos compresores.
El sistema cortará el funcionamiento de un compre-
sor en condiciones de carga parcial. de control.
Caja de control
Operación debida del ciclo del compresor
Panel de acceso
Cuando la temperatura de ajuste y la temperatura caja de control
Motor interior
5
Conexiones de baja tensión
Todos los puertos de los cables de baja
tensión están integrados al tablero
Descarga horizontal
Calentadores de cárter del compresor
Evaporador accionado por correa del ventilador
Motor del ventilador del evaporador - tipo ODP (tipo TEFC opcional)
Ventilador de accionamiento directo del condensador, tipo hélice (excepto 5 ton)
Ventilador de accionamiento directo del condensador - tipo axial (solo 5 ton)
Motor del ventilador del condensador de tipo totalmente cerrado para movimiento de aire
Protección de sobrecarga del compresor
Interruptor de baja y alta presión
Termostato de frío y calor
Protección del ventilador del condensador
Protección de la serpentina del condensador
Control por cable KJR-12B
6 MCCH-R072-240N1
ESPECIFICACIONES
Tonelada nominal 6 8,5
Modelo MCCH-R072N1--ACA MCCH-R100N1--ACA
Alimentación eléctrica V, Ph, Hz
Btu/h 72000 100000
Capacidad de enfriamiento nominal
Enfriamiento kW 21 29.3
Entrada de energía kW 6.6 7.9
Btu/h 72000 100000
Capacidad de calentamiento nominal 21 29.3
Calentamiento kW
Entrada de energía kW 7.5 8.9
Entrada de consumo máximo kW 8.6 12.0
Corriente máxima A 18.3 24.8
Flujo de aire del ventilador interior CFM 2800 2830
Desempeño ESP Pa 80 80
EER Btu/W.h 11.4 11.3
COP Btu/W.h 11.8 11.6
4 3
mm 1.3 1.3
Serpentina interior Espacio entre aletas
FPI 19 19
mm 7 7
Diámetro de la tubería
pulg 9/32 9/32
Tipo
Cantidad 1 1
Ventilador interior Tipo de accionamiento Directo Directo
Cantidad de motores 1 1
Modelo del motor YDK750-4E YDK750-4E
Tipo Scroll Scroll
Cantidad 1 1
Compresor Modelo ZP72KCE-TDF-52E HCJ106
Marca Copeland Danfoss
Capacidad Btu/h 58345 89053
Carga de aceite del refrigerante ml 1656 2400
2.5 3
mm 1.5 1.5
Serpentina exterior Espacio entre aletas
FPI 17 17
mm 7 7
Diámetro de la tubería
pulg 9/32 9/32
Tipo Hélice Hélice
Cantidad 1 1
Ventilador exterior Tipo de accionamiento Directo Directo
Cantidad de motores 1 1
Modelo del motor YDK450-6C YDK580-6C
Tipo R410A R410A
Refrigerante Volumen del refrigerante kg 5 4.8
Control del refrigerante Pistón Pistón
Peso neto kg 229 244
Peso bruto kg 234 249
Dimensión neta An. x Al. x Prof. mm
Envoltorio An. x Al. x Prof. mm
NOTA
Los datos se basan en las siguientes condiciones:
Enfriamiento:
Calentamiento y entrada de energía:
7
Tonelada nominal 10 12
Modelo MCCH-R120N1--ACA MCCH-R140N1--ACA
Alimentación eléctrica V, Ph, Hz
Btu/h 120000 140000
Capacidad de enfriamiento nominal
Enfriamiento kW 35.2 41
Entrada de energía kW 9.3 10.7
Btu/h 120000 140000
Capacidad de calentamiento nominal 35.2 41
Calentamiento kW
Entrada de energía kW 10.6 11.9
Entrada de consumo máximo kW 13.6 15.0
Corriente máxima A 26.5 28.8
Flujo de aire del ventilador interior CFM 3500 4100
Desempeño ESP Pa 80 90
EER Btu/W.h 11.1 11.2
COP Btu/W.h 11.3 11.5
4 4
mm 1.5 1.5
Serpentina interior Espacio entre aletas
FPI 17 17
mm 7 7
Diámetro de la tubería
pulg 9/32 9/32
Tipo
Cantidad 1 1
Ventilador interior Tipo de accionamiento Correa Correa
Cantidad de motores 1 1
Modelo del motor
Tipo Scroll Scroll
Cantidad 2 2
Compresor Modelo
Marca Hitachi Hitachi
Capacidad Btu/h
Carga de aceite del refrigerante ml
2.5 2.5
mm 1.5 1.5
Serpentina exterior Espacio entre aletas
FPI 17 17
mm 7 7
Diámetro de la tubería
pulg 9/32 9/32
Tipo Hélice Hélice
Cantidad 1 1
Ventilador exterior Tipo de accionamiento Directo Directo
Cantidad de motores 1 1
Modelo del motor YDK580-6C YS1100-6P
Tipo R410A R410A
Refrigerante Volumen del refrigerante kg 2.5+2.5 2.6+2.6
Control del refrigerante Pistón Pistón
Peso neto kg 340 343
Peso bruto kg 350 354
Dimensión neta An. x Al. x Prof. mm
Envoltorio An. x Al. x Prof. mm
NOTA
Los datos se basan en las siguientes condiciones:
Enfriamiento:
Calentamiento y entrada de energía:
8 MCCH-R072-240N1
Tonelada nominal 15 20
Modelo MCCH-R180N1--ACA MCCH-R240N1--ACA
Alimentación eléctrica V, Ph, Hz
Btu/h 180000 240000
Capacidad de enfriamiento nominal
Enfriamiento kW 52.7 70.3
Entrada de energía kW 13.3 19.1
Btu/h 180000 240000
Capacidad de calentamiento nominal 52.7 70.3
Calentamiento kW
Entrada de energía kW 13.2 19.5
Entrada de consumo máximo kW 19.7 27.0
Corriente máxima A 38.2 55.4
Flujo de aire del ventilador interior CFM 5500 7600
Desempeño ESP Pa 110 110
EER Btu/W.h 11.3 10.9
COP Btu/W.h 11.7 11.2
4 3
mm 1.3 1.3
Serpentina interior Espacio entre aletas
FPI 19 20
mm 7 7
Diámetro de la tubería
pulg 9/32 9/32
Tipo
Cantidad 1 1
Ventilador interior Tipo de accionamiento Correa Correa
Cantidad de motores 1 1
Modelo del motor YE2-112M-4-4KW
Tipo Scroll Scroll
Cantidad 2 2
Compresor Modelo ZP61KCE-TFD-522+ZP122KCE-TFD-522
Marca Copeland Copeland
Capacidad Btu/h 49986+102018
Carga de aceite del refrigerante ml 1656+2513
3 2.5
mm 1.5 1.5
Serpentina exterior Espacio entre aletas
FPI 17 17
mm 7 7
Diámetro de la tubería
pulg 9/32 9/32
Tipo Hélice Hélice
Cantidad 1 2
Ventilador exterior Tipo de accionamiento Directo Directo
Cantidad de motores 1 2
Modelo del motor YDK550-6E YDK550-6E
Tipo R410A R410A
Refrigerante Volumen del refrigerante kg 2.1+3.4 5.5+5.5
Control del refrigerante Pistón Pistón
Peso neto kg 451 615
Peso bruto kg 471 645
Dimensión neta An. x Al. x Prof. mm
Envoltorio An. x Al. x Prof. mm
NOTA
Los datos se basan en las siguientes condiciones:
Enfriamiento:
Calentamiento y entrada de energía:
9
PLANOS DE DIMENSIONES
Modelos 6 y 8,5 TR Nominal
15
11 145
9 Ventilador del condensador
840
66
147 8
5
857 0
1 13
189
42
60
306
10
2
10 MCCH-R072-240N1
Modelos 10 y 12 TR Nominal
Ventilador del condensador
1462
7 1
11
1222
123
0
56
700
5
388 123 10 84
2
3
42 2
39
369
338
604
580
165
9 52
820
1 13 82
9
655
11
Modelo 15 TR Nominal
1227
196
5
1 130
75
508
800
165 67
508 666
75 67 165
335
467
665
555
232
12 MCCH-R072-240N1
Modelo 20 TR Nominal
Ventilador del condensador
1654
2171
1247
Panel del compresor
125
125
800 800
1670 2192
434 125 125 695
Abertura horizontal
de suministro
Abertura horizontal
de retorno
Panel de control
13
DIAGRAMAS DEL CABLEADO
Aplicación T1 - MCCH-R072N1--ACA
XT4
VA V
MARRON
VERDE
ROJO
B Y C R CN33 CN48
CN1 MARRON
CN49
CN4
T6 CN7
CN2
CN8
DIAGRAMA DEL CABLEADO CT
CN13 CN3 CN32 CN34 4 CN36 CN37CN15 CN30 CN6
CÓDIGO TÍTULO
RY
COMP Compresor T5 RT3 RT4
XS2XP2
XS1XP1
VENT1 Vent. interior XP5
ROJO
COM NO XS5
VENT2
CAP1 Vent. interior CAP RT2
24V
CAP2 P MARRON O K2
XT2 A/V
MARRON
VENT2 VENT1 MARRON
XP1-5 Conectores K1 RT1
ROJO
XS1-5 Conectores
ROJO
14 MCCH-R072-240N1
MCCH-R100N1--ACA
XT4 VA V
MARRON
ROJO
VERDE
B Y C R CN33 CN48
CN1 MARRON
CN49
CN4
T6 CN7
CN2
CN8
DIAGRAMA DEL CABLEADO CT
CÓDIGO TÍTULO CN13 CN3 CN32 CN34 4 CN36CN37CN15 CN30 CN6
RY
COMP Compresor T5 RT3 RT4
XS2XP2
XS1XP1
VENT1 Vent. interior
ROJO
XP5
COMNO XS5
VENT2
CAP1 Vent. interior CAP RT2
24V
CAP2 P MARRON O K2
XT2 A/V
VENT2 VENT1 MARRON
MARRON
XP1-5 Conectores K1 RT1
XS1-5 Conectores
ROJO
ROJO
MARRON
A/V CAP1 XP3 XS3
RT1-4 Sensor de Temp.
KM1 AC Contactor CAP2 KM1
T5 Transformador(24V~) W
XT1 A1 A2 UROJOCOMP A/V
T6 Transformador ROJO 1 2
K1 3 4 V
1 2 3 N 5 6
K2
O A/V 21 22
XT1
XT2 Terminal media
XT4
15
MCCH-R120N1--ACA
S1 S2
RT3_ 1
RT4
PARA SER CONECTADO KJR-12B
RT3_2
RT2_1
RT2_2
H-PRO
H-PRO
RT1
XP1-2
-PRO K1 ROJO
-PRO K2
XS1-2
XS3
SW3
CN7
CN28
CN40
A B
CN36
VERDE
ROJO
NOTA
MARRON
MARRON
VERDE
T1
ROJO
T2
SW3 KJR-12B
MODO
KJR-25B
CÓDIGO TÍTULO
ROJO B Compresor
ROJO VENT_EXT1、2
MARRON MARRON MARRON N Vent. interior
KM1-KM4 Contactor
2 Transformador
CT1-CT4
ROJO
XT1
CT4
CT2
CT1
CT3
XT2
KM1 KM3
KM2 R S T 4
MARRON
A1
A1
A1
21
2
21
21
3
5
3
5
3
5
1
RT4
KM4
COM NC NO H-PRO
4
4
6
6
2
2
22
22
O
A2
A2
22
A2
MARRON
MARRON
MARRON
MARRON
MARRON
XS1-3 Conectores
Conectores
ROJO
16 MCCH-R072-240N1
MCCH-R140N1--ACA
S1 S2
RT3_ 1
RT4
PARA SER CONECTADO KJR-12B
RT3_2
RT2_1
RT2_2
H-PRO
H-PRO
RT1
XP1-2
-PRO K1 ROJO
-PRO K2
XS1-2
XS3
SW3
CN7
CN28
VERDE
CN40
A B
ROJO
CN36
NOTA VENT_O-PRO1
VERDE
MARRON
T1
T2
KJR-12B
SW 3
MODO
KJR-25B
CÓDIGO TÍTULO
ROJO B Compresor
ROJO VENT_EXT1、2
MARRON MARRON MARRON MARRON
N Vent. interior
KM1-KM4 Contactor
2 Transformador
CT1-CT4
ROJO
XT1
CT4
CT2
CT1
CT3
XT2
KM1 KM2 R S T 2
MARRON
A1
A1
A1
21
A1
21
RT4
21
21
3
5
3
5
3
5
3
5
Y
1
H-PRO
KM3 KM4
COM NC NO O
4
4
6
6
2
2
22
22
A2
A2
22
22
A2
XS1-3 Conectores
MARRON
MARRON
MARRON
MARRON
MARRON
MARRON
XP1-2 Conectores
2 protección de temp.
XT1 A/V
RT1 Sensor de Temp. interior habitación
T2(V) T3(W) T2(V) T3(W) W W 1 2 3 N
V U RT2_1、RT2_2
RT2
A /V A /V VENT_O-PRO1-2
T1(U ) T1(U ) U V
Y/
17
MCCH-R180N1--ACA
S1 S2
RT3_1
RT4
PARA SER CONECTADO KJR-12B
RT3_2
RT2_1
RT2_2
H-PRO
H-PRO
RT1
XP1-2
-PRO K1 ROJO
-PRO K2
XS1-2
XS3
CN28
CN40
VERDE
A B
CN36
ROJO
NOTA
VENT_O-PRO1
MARRON
MARRON
VERDE
T1
ROJO
T2
SW3 KJR-12B
MODE
KJR-25B
CÓDIGO TÍTULO
ROJO B Compresor
ROJO VENT_EXT1、2
MARRON MARRON MARRON MARRON
N Vent. interior
KM1-KM4 Contactor
2 Transformador
ROJO CT1-CT4
CT4
CT2
CT1
XT1
CT3
A1
A1
A1
2
41
41
3
5
3
5
3
5
3
5
1
6
2
2
H-PRO
4
4
4
4
42
42
A2
A2
A2
A2
MARRON
MARRON
MARRON
MARRON
O
MARRON
MARRON
XS1-3 Conectores
XT1 A/V XP1-2 Conectores
T2(V) T3(W) T2(V) T3(W) W W 1 2 3 N 2 protección de temp.
V U
A/V A/V RT1 Sensor de Temp. interior habitación
T1(U) T1(U) U V
A/V RT2_1、RT2_2
RT2
COMP_A COMP_B VENT_EXT N VENT_O-PRO1-2
18 MCCH-R072-240N1
MCCH-R240N1--ACA
S1 S2
RT3_ 1
RT4
PARA SER CONECTADO KJR-12B
RT3_2
RT2_ 1
RT2_2
H-PRO
H-PRO
RT1
XP1-2
-PRO K1
-PRO K2
XS1-2
XS3
( WH TE)
( B ACK)
JP1
B UE
RED
CN9 CN22 CN20 CN21 CN23 CN24 CN25 CN13
CN29
SW3
CN7
CN28
CN40
A B
CN36
VERDE
ROJO
NOTA
MARRON
MARRON
VERDE
ROJO
T1 XT4
KJR-12B
SW3
T2 MODO
KJR-25B
CÓDIGO TÍTULO
B Compresor
ROJO VENT_EXT1、2
ROJO N Vent. interior
MARRON MARRON MARRON KM1-KM5 Contactor
2 Transformador
CT1-CT4
XT1
ROJO
XT2
CT4
CT2
MARRON
CT1
XT
CT3
KM1 KM2 R S T
2
MARRON
MARRON
A1
A1
A1
A1
21
21
RT4
21
21
3
5
3
5
3
5
5
3
1
1
KM5 H-PRO
KM3 COMNC NO O
4
4
6
6
2
2
22
22
22
A2
A2
A2
A2
22
XS1-3 Conectores
ROJO
ROJO
MARRON
MARRON
MARRON
XT3
XT1 XP1-2 Conectores
1 2 3N A/V RT1
2 protección de temp.
Sensor de Temp. interior habitación
T2(V) T3(W) T2(V) T3(W) W
U
RT2_1、RT2_2
RT2
ROJO
ROJO
19
DATOS DE DESEMPEÑO
Aplicación T1 - Capacidad de enfriamiento para 6 toneladas nominal
Flujo de aire (CFM) 2400 2600 2800
Ent (DB) (°C) 24 26 30 32 24 26 30 32 24 26 30 32
TC 61.3 62.8 64.0 65.3 65.4 66.8 68.2 69.6 69.5 70.9 72.4 74.0
16 SC 53.1 60.3 65.3 66.6 57.1 63.6 67.8 69.6 61.1 66.9 70.2 72.7
5325.4 5469.4 5710.3 5992.2 5614.7 5758.7 6011.6 6299.6 5904.0 6048.0 6313.0 6606.9
TC 74.9 76.5 78.0 79.7 75.8 77.4 79.0 80.7 76.7 78.4 80.0 81.7
29 20 SC 40.6 50.6 61.8 73.7 42.6 53.8 64.8 75.4 44.7 57.0 67.9 77.1
6104.2 6279.2 6710.7 7060.7 6170.5 6345.5 6783.1 7133.1 6236.8 6411.8 6855.4 7205.4
TC 78.5 80.2 81.9 83.6 79.0 80.7 82.4 84.1 79.5 81.2 82.9 84.6
23 SC 26.3 39.0 47.8 54.6 26.7 38.8 48.1 56.9 27.2 38.5 48.3 59.1
7524.0 7724.0 8074.0 8467.9 7560.1 7760.1 8110.1 8504.1 7596.3 7796.3 8146.3 8540.3
TC 60.1 61.4 62.7 64.0 62.1 63.5 64.8 66.2 64.1 65.5 66.9 68.4
16 SC 52.2 57.0 58.9 61.2 54.5 59.6 61.6 64.5 56.8 62.1 64.3 67.8
6273.9 6452.9 6705.8 6993.8 6418.5 6597.5 6856.5 7150.5 6563.2 6742.2 7007.2 7307.2
TC 66.8 63.9 64.6 66.3 68.0 69.5 71.0 72.4 69.3 75.0 77.3 78.5
35 20 SC 39.2 49.7 60.5 64.2 41.2 52.9 64.6 68.5 43.2 56.1 68.8 72.9
5975.0 5692.7 6039.1 6407.2 6065.4 6096.5 6491.2 6841.2 6155.8 6500.3 6943.2 7275.1
TC 77.9 79.6 81.3 83.0 78.4 80.0 81.7 83.4 78.8 80.5 82.2 83.9
Temperatura ambiente
23 SC 25.4 37.2 46.8 56.3 25.8 38.1 48.3 58.6 26.2 38.9 49.8 61.0
7940.2 8190.2 8697.9 9097.9 7970.3 8220.3 8728.0 9128.0 8000.4 8250.4 8758.1 9158.1
TC 54.7 55.8 57.0 58.2 56.6 57.8 59.1 60.3 58.6 59.8 61.1 62.4
16 SC 47.7 49.9 51.7 53.1 51.8 53.4 55.9 57.5 55.8 56.9 60.2 61.9
6367.6 6590.5 6968.1 7256.1 6506.2 6735.2 7112.8 7406.7 6644.8 6879.8 7257.4 7557.4
TC 65.4 66.8 68.2 69.7 67.0 68.5 69.9 71.4 68.6 70.1 71.6 73.1
40 20 SC 36.5 49.6 57.7 65.2 38.8 50.6 62.6 68.6 41.0 51.6 67.5 72.0
6575.5 6819.4 7197.0 7541.0 6690.0 6934.0 7317.6 7661.6 6804.5 7048.5 7438.1 7782.1
TC 76.3 77.9 79.7 81.2 76.2 77.8 79.5 81.1 76.2 77.8 79.4 81.1
23 SC 24.6 35.7 48.7 58.9 24.5 37.0 49.9 60.6 24.5 38.2 51.1 62.3
8604.0 8884.0 9497.7 9885.7 8597.9 8877.9 9485.7 9879.6 8591.9 8871.9 9473.6 9873.6
TC 47.2 48.3 49.4 50.5 48.9 50.0 51.1 52.2 50.5 51.6 52.7 53.9
16 SC 48.8 48.5 48.8 51.2 47.1 48.3 49.8 51.6 45.4 48.0 50.8 52.1
6978.7 7222.6 7440.6 7734.6 7093.2 7337.2 7561.1 7855.1 7207.7 7451.7 7681.7 7975.6
TC 57.0 58.2 59.5 60.9 58.5 59.8 61.1 62.5 60.0 61.4 62.7 64.1
46 20 SC 31.8 42.8 54.9 59.9 34.0 46.1 57.4 61.5 36.3 49.4 59.9 63.1
7272.4 7599.6 7918.9 8262.9 7380.9 7649.8 8033.5 8377.4 7489.4 7700.1 8148.0 8491.9
TC 74.5 76.1 77.8 79.5 70.4 72.0 73.6 75.2 66.4 67.8 69.3 70.9
23 SC 20.5 31.0 43.4 56.8 21.0 32.8 45.4 58.2 21.5 34.6 47.3 59.7
9130.1 9430.1 10043.9 10449.9 8840.8 9134.8 9742.5 10142.5 8551.5 8839.5 9441.2 9835.2
NOTA
1. Todas las capacidades son en bruto y no se ha considerado el calor del ventilador interior. Para obtener la capacidad de
enfriamiento NETA restar el calor del ventilador interior.
2. TC= capacidad total (Unidad: 1000Btu/h)
3. SC= capacidad sensible (Unidad: 1000Btu/h)
20 MCCH-R072-240N1
Capacidad de calentamiento para 6 toneladas nominal
Capacidades netas (kW)-2800 CFM
Temp. Exterior (
70%RH 15 20 24 27 15 20 24 27
-9 14.2 13.7 13.4 12.9 5.6 5.9 6.1 6.3
-6 15.7 15.2 14.8 14.3 5.9 6.2 6.4 6.6
-3 17.4 16.9 16.4 15.9 6.2 6.5 6.7 6.9
0 19.3 18.8 18.2 17.7 6.6 6.8 7.1 7.3
3 22.8 22.1 21.4 20.8 6.9 7.2 7.4 7.7
7 26.8 26 25.2 24.5 7.3 7.5 7.8 8.1
9 28.7 27.8 27 26.2 7.4 8.2 8.7 9.2
12 30.4 29.5 28.6 27.7 7.7 8.6 9 9.6
15 32.2 31.3 30.3 29.4 7.8 8.8 9.2 9.8
18 34.1 33.1 32.1 31.2 8.1 8.9 9.5 10.1
21 36.2 35.1 34.1 33 8.2 9.1 9.6 10.1
24 38.3 37.2 36.1 35 8.4 9.2 10 10.3
NOTA
zona de escarcha.
21
Aplicación T1 - Capacidad de enfriamiento para 8,5 toneladas nominal
Flujo de aire (CFM) 2400 2600 2830
Ent (DB) (°C) 24 26 30 32 24 26 30 32 24 26 30 32
TC 72.8 74.6 76.1 77.8 77.6 79.4 81.1 82.9 82.4 84.2 86.1 88.0
16 SC 63.1 71.7 77.7 76.5 67.8 75.6 80.6 81.5 72.5 79.5 83.5 86.5
6775.5 6920.6 7165.9 7451.2 7012.8 7157.9 7413.1 7703.3 7250.1 7395.2 7660.3 7955.5
TC 88.8 90.8 92.7 94.8 89.9 91.9 93.9 96.0 91.0 93.0 95.1 97.2
29 20 SC 48.3 60.2 73.5 87.7 50.7 64.0 77.1 89.7 53.1 67.8 80.7 91.7
7405.6 7580.7 7986.6 8336.7 7460.0 7635.1 8045.9 8396.0 7514.3 7689.4 8105.3 8455.4
TC 93.1 95.2 97.3 99.4 93.7 95.8 97.9 100.0 94.3 96.4 98.5 100.6
23 SC 31.4 46.5 57.0 65.1 31.9 46.2 57.3 67.8 32.4 45.9 57.6 70.5
8464.7 8664.8 9014.9 9410.1 8494.4 8694.5 9044.6 9439.8 8524.1 8724.2 9074.3 9469.4
TC 71.3 73.0 74.6 76.2 73.7 75.4 77.1 78.8 76.1 77.8 79.6 81.4
16 SC 62.0 67.8 70.1 72.9 64.7 70.8 73.3 76.8 67.4 73.8 76.5 80.7
7457.3 7637.5 7892.7 8182.9 7576.0 7756.1 8016.3 8311.4 7694.6 7874.8 8139.9 8440.0
TC 79.2 76.0 76.9 79.0 80.7 82.5 84.4 86.2 82.2 89.0 91.9 93.4
35 20 SC 46.6 59.2 72.0 76.5 49.0 62.9 76.9 81.6 51.4 66.6 81.8 86.7
7223.0 7288.3 7359.1 7724.0 7297.2 7494.3 7729.9 8080.0 7371.3 7700.2 8100.7 8435.9
TC 92.4 94.5 96.6 98.7 92.9 95.0 97.1 99.2 93.4 95.5 97.6 99.7
Temperatura ambiente
23 SC 30.3 44.4 55.8 67.1 30.8 45.4 57.6 69.9 31.3 46.4 59.4 72.7
8906.2 9156.3 9631.9 10032.0 8930.9 9181.0 9656.6 10056.7 8955.7 9205.8 9681.4 10081.5
0 7 5
TC 64.9 66.3 67.9 69.4 67.2 68.7 70.3 71.9 69.5 71.1 72.7 74.4
16 SC 56.7 59.4 61.6 63.4 61.5 63.5 66.6 68.6 66.3 67.6 71.6 73.8
7636.9 7862.2 8213.0 8503.2 7750.7 7980.8 8331.7 8626.8 7864.4 8099.5 8450.3 8750.4
TC 77.6 79.4 81.1 83.0 79.5 81.3 83.1 85.0 81.4 83.2 85.1 87.0
40 20 SC 43.4 59.0 68.7 77.7 46.1 60.2 74.5 81.7 48.8 61.4 80.3 85.7
7823.2 8068.3 8419.2 8764.4 7917.1 8162.3 8518.1 8863.2 8011.0 8256.2 8617.0 8962.1
TC 90.5 92.5 94.7 96.6 90.4 92.4 94.5 96.5 90.3 92.3 94.3 96.4
23 SC 29.4 42.6 58.1 70.2 29.3 44.1 59.5 72.2 29.2 45.6 60.9 74.2
9655.2 9935.3 10515.9 10906.1 9650.3 9930.4 10506.0 10901.1 9645.3 9925.4 10496.1 10896.2
9 1 0 1 1 2
TC 52.8 54.2 55.5 57.0 54.7 56.1 57.5 59.0 56.6 58.0 59.5 61.0
16 SC 54.6 54.4 54.8 57.8 52.6 54.1 56.0 58.3 50.6 53.8 57.2 58.8
8213.5 8458.6 8678.9 8974.0 8307.4 8552.6 8777.7 9072.9 8401.4 8646.5 8876.6 9171.8
TC 64.3 65.8 67.5 69.2 66.1 67.7 69.4 71.1 67.9 69.6 71.3 73.0
46 20 SC 34.5 47.7 62.1 68.0 37.2 51.6 65.0 69.9 39.9 55.5 67.9 71.8
8247.1 8512.3 8868.1 9213.3 8336.1 8606.2 8962.1 9307.2 8425.1 8700.2 9056.0 9401.2
TC 85.0 87.0 89.1 91.2 80.2 82.1 84.1 86.1 75.4 77.2 79.1 81.0
23 SC 21. 2 33.7 48.5 64.4 21.8 35.8 50.8 66.1 22.4 37.9 53.1 67.8
9958.8 10258.9 10839.4 11244.5 9721.5 10016.7 10592.2 10992.3 9484.2 9774.4 10345.1 10740.2
9 4 5 7 2 3 1 2
NOTA
1. Todas las capacidades son en bruto y no se ha considerado el calor del ventilador interior. Para obtener la capacidad de
enfriamiento NETA restar el calor del ventilador interior.
2. TC= capacidad total (Unidad: 1000Btu/h)
3. SC= capacidad sensible (Unidad: 1000Btu/h)
22 MCCH-R072-240N1
Capacidad de calentamiento para 8,5 toneladas nominal
Capacidades netas (kW)-2830 CFM
Temp. Exterior (
70%RH 15 20 24 27 15 20 24 27
-9 17 16.5 16.4 16.4 7.2 7.9 8.3 8.9
-6 17.8 17.3 17.1 16.9 7.3 8 8.4 9
-3 18.8 18.5 18.4 18.1 7.4 8.1 8.6 9.2
0 20.3 20 19.7 19.4 7.5 8.2 8.7 9.3
3 23.3 23.1 22.7 22.4 7.6 8.4 8.9 9.4
7 30.3 30 29.6 29.2 7.9 8.9 9.2 9.7
9 30.5 30.2 29.9 29.6 8.2 9.1 9.6 10.2
12 32.4 33.5 33.4 33.1 8.5 9.5 10 10.6
15 35 34.4 34.2 33.8 8.7 9.7 10.2 10.8
18 37.1 36.4 36 35.7 9 9.9 10.5 11.1
21 39.8 38.9 38.4 37.9 9.1 10.1 10.6 11.1
24 42 40.9 40.2 39.8 9.3 10.2 11 11.4
NOTA
zona de escarcha.
23
Aplicación T1 - Capacidad de enfriamiento para 10 toneladas nominal
Flujo de aire (CFM) 3000 3250 3500
Ent (DB) (°C) 24 26 30 32 24 26 30 32 24 26 30 32
TC 86.6 88.5 90.5 92.5 89.1 91.0 93.1 95.2 91.5 93.6 95.7 97.8
16 SC 71.5 73.0 74.8 76.5 77.0 78.7 80.5 82.3 82.5 84.4 86.3 88.2
8302.6 8445.9 8707.6 9001.0 8400.4 8547.1 8808.9 9105.6 8498.3 8648.4 8910.1 9210.2
TC 98.7 101.0 103.2 105.6 99.8 102.0 104.3 106.6 100.8 103.0 105.3 107.6
29 20 SC 54.7 71.0 83.2 98.1 56.7 73.0 87.0 101.3 58.8 74.9 90.9 104.4
8784.5 8959.6 9207.0 9557.1 8825.0 9000.1 9247.5 9597.6 8865.5 9040.6 9288.0 9638.1
TC 103.3 105.6 107.9 110.2 103.6 106.0 108.3 110.6 104.0 106.3 108.6 111.0
23 SC 34.4 49.0 61.1 74.8 34.9 49.7 62.4 76.0 35.4 50.5 63.8 77.2
9502.6 9702.7 10052.8 10446.1 9516.1 9716.2 10066.3 10463.0 9529.6 9729.7 10079.8 10479.9
8 1 3 0 8 9
TC 79.5 81.4 83.2 85.0 82.1 84.0 85.9 87.8 84.8 86.7 88.7 90.6
16 SC 67.9 69.5 71.0 72.7 73.5 75.2 76.8 78.6 79.0 80.8 82.7 84.6
8637.6 8819.3 9077.7 9367.7 8742.2 8923.9 9185.6 9479.0 8846.8 9028.5 9293.6 9590.3
TC 92.5 92.8 95.8 98.8 95.7 97.9 100.1 102.3 99.0 103.0 104.3 105.8
35 20 SC 51.7 66.8 82.7 99.3 54.7 71.1 87.3 100.1 57.7 75.4 91.9 100.8
8508.3 8601.8 8890.3 9233.7 8636.5 8800.9 9059.0 9372.0 8764.7 9000.0 9227.7 9510.4
Temperatura ambiente
TC 102.4 104.7 107.0 109.4 102.7 104.9 107.3 109.7 102.9 105.2 107.5 109.9
23 SC 32.9 49.0 61.7 74.6 33.7 50.2 64.1 78.1 34.5 51.3 66.5 81.6
10064.0 10310.8 10621.8 11025.3 10074.2 10320.9 10631.9 11035.4 10084.3 10331.0 10642.0 11045.5
0 8 8 3 2 9 9 4 3 0 0 5
TC 72.2 73.8 75.5 77.3 75.0 76.7 78.5 80.3 77.8 79.6 81.5 83.3
16 SC 64.3 65.8 67.4 68.9 69.9 71.6 73.2 74.9 75.6 77.3 79.1 80.9
8967.7 9196.1 9380.1 9676.9 9079.1 9310.8 9498.2 9795.0 9190.4 9425.5 9616.3 9913.0
TC 86.3 88.2 90.3 92.4 88.5 90.5 92.6 94.7 90.8 92.8 94.9 97.0
40 20 SC 48.8 63.3 78.3 91.4 51.9 68.2 85.0 93.4 55.1 73.0 91.7 95.4
9225.3 9468.7 9659.4 10006.2 9313.0 9559.8 9750.5 10097.3 9400.8 9650.9 9841.6 10188.4
2 3 4
TC 99.4 101.7 103.9 106.2 100.1 102.4 104.6 106.9 100.8 1 03.0 105.3 107.6
23 SC 31.2 46.2 59.9 73.9 32.0 48.3 63.6 78.6 32.7 50.3 67.3 83.2
10661.9 10942.0 11349.7 11749.8 10688.9 10969.0 11376.7 11776.8 10715.9 10996.0 11403.7 11803.8
9 0 7 8 9 0 7 8 9 0 7 8
TC 60.4 61.9 63.5 65.1 62.9 64.4 66.1 67.7 65.4 67.0 68.6 70.4
16 SC 60.0 61.6 63.1 64.7 61.4 63.0 64.5 66.2 62.8 64.3 66.0 67.6
9314.2 9557.6 9784.3 10077. 9412.1 9658.8 9885.5 10182. 9509.9 9760.0 9986.7 10286.
6 2 8
TC 74.1 74.4 77.7 79.6 75.7 77.5 79.4 81.3 77.4 80.7 81.2 83.1
46 20 SC 40.1 56.0 73.9 75.6 43.3 60.3 76.6 78.4 46.6 64.6 79.4 81.3
9819.6 10210.6 10275.4 10622.1 9883.7 10155.5 10342.9 10689.6 9947.8 10100.3 10410.3 10757.1
6 4 1 5 9 6 3 3 1
TC 90.3 92.5 94.5 96.8 91.1 93.2 95.4 97.6 91.8 94.0 96.2 98.5
23 SC 24.5 39.1 54.2 69.2 25.1 41.5 57.8 73.8 25.7 43.9 61.4 78.4
10834.0 11134.1 11538.4 11938.5 10864.4 11164.5 11572.1 11972.2 10894.7 11194.8 11605.9 12006.0
0 1 4 5 4 5 1 2 7 8 9 0
NOTA
1. Todas las capacidades son en bruto y no se ha considerado el calor del ventilador interior. Para obtener la capacidad de
enfriamiento NETA restar el calor del ventilador interior.
2. TC= capacidad total (Unidad: 1000Btu/h)
3. SC= capacidad sensible (Unidad: 1000Btu/h)
24 MCCH-R072-240N1
Capacidad de calentamiento para 10 toneladas nominal
Capacidades netas (kW)-3500 CFM
Temp. Exterior (
70%RH 15 20 24 27 15 20 24 27
-9 21.4 20.8 20.6 20.6 9.3 9.5 10 10.5
-6 22.4 21.8 21.6 21.3 9.4 9.7 10.3 10.7
-3 23.7 23.4 23.2 22.8 9.5 10 1 0.5 10.9
0 25.5 25.2 24.8 24.5 9.6 10.2 10.7 11.2
3 29.4 29.1 28.7 28.3 9.8 10.4 10.9 11.4
7 35.4 35 33 32.8 10.1 10.6 11.1 11.6
9 38.5 38 37.7 37.3 10.3 10.8 11.3 11.9
12 40.9 42.3 42.1 41.7 10.5 11 11.5 12.1
15 44.1 43.4 43.1 42.7 10.7 11.3 11.8 12.5
18 46.7 45.9 45.4 45 10.9 11.5 12.1 12.7
21 50.1 49.1 48.4 47.8 11.3 11.8 12.3 12.9
24 53 51.6 50.7 50.1 11.5 12 12.6 13.2
NOTA
zona de escarcha.
25
Aplicación T1 - Capacidad de enfriamiento para 12 toneladas nominal
Flujo de aire (CFM) 3500 3800 4100
Ent (DB) (°C) 24 26 30 32 24 26 30 32 24 26 30 32
TC 103.6 106.0 108.4 110.7 106.6 109.0 11 1.4 113.7 109.6 112.0 114.4 116.7
16 SC 89.5 91.6 93.7 95.7 92.5 94.6 96.7 98.7 95.5 97.6 99.7 101.7
9115.8 9427.3 9784.5 10298.9 9374.6 9686.2 10043.3 10557.7 9633.5 9945.0 10302.2 10816.6
TC 116.1 118.8 121.4 124.0
9 119.1 121.8 124.4
3 127.0
7 1 22.1 124.8 127.4
2 130.0
6
29 20 SC 65.9 84.9 101.3 117.8 68.9 87.9 104.3 120.8 71.9 90.9 107.3 123.8
10196.6 10531.8 10906.2 11439.2 10455.4 10790.6 11165.0 11698.0 10714.3 11049.5 11423.9 11956.9
TC 120.6
6 123.4
8 126.1
2 128.7
2 123.6
4 126.4
6 129.1
0 131.7
0 126.6
3 129.4
5 132.1
9 134.7
9
23
SC 40.4 57.8 72.6 88.3 43.4 60.8 75.6 91.3 46.4 63.8 78.6 94.3
10578.5 10928.7 11311.7 11853.1 10837.3 11187.5 11570.6 12111.9 11096.2 11446.4 11829.4 12370.8
TC 95.5
5 97.8
7 100.0
7 102.1
1 98.5
3 100.8
5 103.0
6 105.1
9 101.5
2 103.8
4 106.0
4 108.1
8
16
SC 85.4 87.5 89.4 91.4 88.4 90.5 92.4 94.4 91.4 93.5 95.4 97.4
8494.5 8814.7 9240.9 9755.3 8753.4 9073.6 9499.7 10014.1 9012.2 9332.4 9758.6 10273.0
TC 111.4 114.0 116.5 119.0 114.4 117.0 119.5 122.0
1 117.4 120.0 122.5 125.0
0
35 20
SC 63.5 82.7 101.6 116.4 66.5 85.7 104.6 119.4 69.5 88.7 107.6 122.4
9848.5 10022.5 10454.6 11065.2 10107.4 10261.4 10713.4 11324.1 10366.2 10500.2 10972.3 11582.9
TC 119.5 122.2
5 124.9
6 127.6
2 122.5
4 125.2
4 127.9
4 130.6
1 125.5
2 128.2
2 130.9
3 133.6
9
Temperatura ambiente
23
SC 39.0 58.3 74.5 90.8 42.0 61.3 77.5 93.8 45.0 64.3 80.5 96.8
10569.8 10920.0 11389.4 11939.4 10828.7 11178.9 11648.2 12198.2 11087.6 11437.8 11907.1 12457.1
TC 87.2
8 89.3
0 91.3
4 93.3
4 90.2
7 92.3
9 94.3
2 96.3
2 93.2
6 95.3
8 97.3
1 99.3
1
16
SC 81.3 83.3 85.2 87.0 84.3 86.3 88.2 90.0 87.3 89.3 91.2 93.0
9806.0 10117.6 10457.5 10980.5 10064.9 10376.5 10716.4 11239.4 10323.7 10635.3 10975.2 11498.2
TC 103.0 105.4
6 107.8
5 110.1
5 106.0
9 108.4
5 110.8
4 113.1
4 109.0
7 111.4
3 113.8
2 116.1
2
40 20
SC 60.3 79.3 98.9 108.6 63.3 82.3 101.9 111.6 66.3 85.3 104.9 114.6
11180.2 11506.8 11881.2 12414.2 11439.1 11765.6 12140.0 12673.0 11697.9 12024.5 12398.9 12931.9
TC 116.5
2 119.2
8 121.8
2 124.4
2 119.5
1 122.2
6 124.8
0 127.4
0 122.5
9 125.2
5 127.8
9 130.4
9
23
SC 37.0 56.1 74.0 91.3 40.0 59.1 77.0 94.3 43.0 62.1 80.0 97.3
12347.3 12697.5 13089.2 13639.2 12606.2 12956.4 13348.0 13898.0 12865.0 13215.2 13606.9 14156.9
TC 77.0
3 78.9
5 80.8
2 82.6
2 80.0
2 81.9
4 83.8
0 85.6
0 83.0
0 84.9
2 86.8
9 88.6
9
16
SC 75.3 77.2 79.0 80.8 78.3 80.2 82.0 83.8 81.3 83.2 85.0 86.8
10435.3 10746.9 11242.1 11756.5 10694.2 11005.7 11500.9 12015.3 10953.0 11264.6 11759.8 12274.2
TC 92.0
3 94.2
9 96.4
1 98.5
5 95.0
2 97.2
7 99.4
9 101.5
3 98.0
0 100.2
6 102.4
8 104.5
2
46 20
SC 54.2 74.1 93.1 95.1 57.2 77.1 96.1 98.1 60.2 80.1 99.1 101.1
11802.4 11982.3 12503.4 13036.4 12061.3 12241.2 12762.3 13295.3 12320.1 12500.0 13021.1 13554.1
TC 109.9
4 112.5
3 115.0
4 117.5
4 112.9
3 115.5
2 118.0
3 120.5
3 115.9
1 118.5
0 121.0
1 123.5
1
23
SC 32.9 52.2 71.1 89.7 35.9 55.2 74.1 92.7 38.9 58.2 77.1 95.7
13295.8 13646.0 14193.0 14743.0 13554.7 13904.9 14451.9 15001.9 13813.5 14163.7 14710.7 15260.7
NOTA
1. Todas las capacidades son en bruto y no se ha considerado el calor del ventilador interior. Para obtener la capacidad de
enfriamiento NETA restar el calor del ventilador interior.
2. TC= capacidad total (Unidad: 1000Btu/h)
3. SC= capacidad sensible (Unidad: 1000Btu/h)
26 MCCH-R072-240N1
Capacidad de calentamiento para 12 toneladas nominal
Capacidades netas (kW)-4100 CFM
Temp. Exterior (
70%RH 15 20 24 27 15 20 24 27
-9 25.6 25 24.8 24.8 10.5 11.4 11.9 12.7
-6 26.7 26 25.8 25.5 10.6 11.5 12.1 12.9
-3 28.1 27.7 27.5 27.1 10.7 11.6 12.3 13.1
0 30 29.6 29.2 28.9 10.8 11.8 12.5 13.2
3 34.1 33.8 33.3 32.9 11 12 12.7 13.4
7 40.8 40 39.3 38.7 11.4 11.9 12.9 13.8
9 43.7 43.2 42.8 42.4 11.8 13 13.7 14.5
12 46.2 47.7 47.5 47.1 12.2 13.5 14.2 15
15 49.6 48.9 48.6 48.1 12.5 13.8 14.5 15.3
18 52.4 51.5 51 50.6 12.8 14.1 14.9 15.6
21 56 54.9 54.2 53.5 13 14.3 15 15.7
24 59 57.5 56.6 56 13.3 14.5 15.5 16
NOTA
zona de escarcha.
27
Aplicación T1 - Capacidad de enfriamiento para 15 toneladas nominal
Flujo de aire (CFM) 4000 5000 5500
Ent (DB) (°C) 24 26 30 32 24 26 30 32 24 26 30 32
TC 127.3 129.8 132.7 135.3 130.8 133.4 136.3 139.0 134.3 137.0 139.9 142.8
16 SC 106.2 108.2 110.6 112.9 113.9 116.1 118.6 121.0 121.5 124.1 126.7 129.2
10063.2 10360.5 10811.1 11311.4 10392.2 10700.9 11151.5 11663.2 10721.3 11041.3 11492.0 12015.0
2 5 1 4 2 9 5 2 3 3 0 0
TC 144.3 147.3 150.4 153.6 145.8 148.8 151.9 155.0 147.2 150.2 153.3 156.4
29 20 SC 82.7 105.3 122.4 143.1 85.5 108.1 127.8 147.6 88.4 11 0.9 133.2 152.0
11682.2 12017.2 12490.6 13023.6 11818.4 12153.4 12626.7 13159.7 11954.6 12289.6 12762.9 13295.9
2 2 6 6 4 4 7 7 6 6 9 9
TC 150.7 153.8 157.0 160.0 151.2 154.3 157.5 160.6 151.7 154.8 158.0 161.2
23 SC 54.2 74.5 91.4 110.5 54.9 75.6 93.3 112.2 55.7 76.7 95.2 113.8
12280.0 12630.0 13114.7 13642.0 12325.4 12675.4 13160.1 13698.7 12370.8 12720.8 13205.5 13755.5
0 0 7 0 4 4 1 7 8 8 5 5
TC 117.3 119.9 122.4 124.8 121.1 123.6 126.2 128.7 124.8 127.3 130.0 132.7
16 SC 101.1 103.3 105.3 107.6 108.9 111.2 113.5 115.9 1 16.7 119.1 121.6 124.2
10131.7 10440.4 11072.6 11561.6 10483.5 10792.2 11435.7 11936.0 10835.3 11144.0 11798.9 12310.5
7 4 6 6 5 2 7 0 3 0 9 5
TC 135.6 136.0 140.0 144.1 140.1 143.0 146.0 149.0 144.7 150.0 152.0 153.9
35 20 SC 78.5 99.5 121.6 144.8 82.7 105.5 128.1 145.9 86.9 111.4 134.6 147.0
11768.6 11661.0 12440.7 12951.0 12199.8 12330.5 13008.1 13416.3 12631.0 13000.0 13575.5 13881.5
6 0 7 0 8 5 1 3 0 0 5 5
TC 149.5 152.5 155.7 159.0 149.9 152.9 156.1 159.3 150.2 153.2 156.4 159.7
Temperatura ambiente
23 SC 52.2 74.6 92.2 110.2 53.3 76.2 95.6 115 .2 54.3 77.7 99.0 120.1
13188.3 13527.0 14227.3 14788.6 13222.4 13561.0 14261.3 14822.7 13256.4 13595.1 14295.4 14856.7
3 0 3 6 4 0 3 7 4 1 4 7
TC 107.1 109.3 111.6 114.0 111.1 113.4 115.8 118.2 115.1 117.5 120.0 122.4
16 SC 96.1 98.1 100.3 102.2 104.0 106.2 108.4 110.6 111.9 114.2 116.6 119.0
11661.8 11959.1 12387.0 12898.7 12036.3 12344.9 12784.2 13295.9 12410.7 12730.7 13181.4 13693.0
8 1 0 7 3 9 2 9 7 7 4 0
TC 126.9 129.5 132.3 135.1 130.1 132.7 135.6 138.3 133.2 135.9 138.8 141.6
40 20 SC 74.4 94.5 115.5 133.8 78.8 101.4 124.9 136.5 83.3 108.2 134.2 139.3
13553.2 13865.5 14350.2 14871.9 13848.3 14171.9 14656.6 15178.2 14143.3 14478.3 14963.0 15484.6
2 5 2 9 3 9 6 2 3 3 0 6
TC 145.3 148.3 151.4 154.5 146.3 149.3 152.4 155.5 147.2 150.2 153.3 156.4
23 SC 49.8 70.7 89.8 109.3 50.9 73.5 95.0 115.8 51.9 76.4 100.2 122.2
15297.1 15647.1 16154.5 16704.5 15387.9 15737.9 16245.3 16795.3 15478.7 15828.7 16336.1 16886.1
1 1 5 5 9 9 3 3 7 7 1 1
TC 97.1 99.0 101.3 103.3 100.6 102.6 104.9 107.0 104.0 106.2 108.5 110.7
16 SC 96.6 98.6 100.7 102.8 98.5 100.6 102.7 104.9 100.4 102.5 104.7 106.9
13281.6 13578.9 14018.2 14518.5 13610.7 13919.3 14358.6 14870.3 13939.7 14259.7 14699.0 15222.0
6 9 2 5 7 3 6 3 7 7 0 0
TC 116.3 116.5 121.2 123.7 118.6 121.0 123.6 126.1 120.8 125.4 126.0 128.5
46 20 SC 68.6 90.8 115.8 118.1 73.2 96.8 119.6 122.0 77.8 102.8 123.5 126.0
14941.3 15060.6 15726.9 16248.5 15156.9 15480.5 15953.9 16475.5 15372.5 15900.4 16180.8 16702.5
3 6 9 5 9 5 9 5 5 4 8 5
TC 139.0 141.8 144.7 147.7 140.0 142.9 145.9 148.9 141.1 144.0 147.1 150.1
23 SC 46.8 67.2 88.2 109.1 47.6 70.6 93.2 115.5 48.5 73.9 98.3 122.0
17280.0 17630.0 18126.1 18676.1 17382.1 17732.1 18239.5 18789.5 17484.3 17834.3 18353.0 18903.0
0 0 1 1 1 1 5 5 3 3 0 0
NOTA
1. Todas las capacidades son en bruto y no se ha considerado el calor del ventilador interior. Para obtener la capacidad de
enfriamiento NETA restar el calor del ventilador interior.
2. TC= capacidad total (Unidad: 1000Btu/h)
3. SC= capacidad sensible (Unidad: 1000Btu/h)
28 MCCH-R072-240N1
Capacidad de calentamiento para 15 toneladas nominal
Capacidades netas (kW)-5500 CFM
Temp. Exterior (
70%RH 15 20 24 27 15 20 24 27
-9 30.6 30 29.8 29.8 11.8 12.7 13.2 14
-6 31.7 31 30.8 30.5 11.9 12.8 13.4 14.2
-3 33.1 32.7 32.5 32.1 12 12.9 13.6 14.4
0 35 34.6 34.2 33.9 12.1 13.1 13.8 14.5
3 39.1 38.8 38.3 37.9 12.3 13.3 14 14.7
7 45.8 45 44.3 43.7 12.7 13.2 14.2 15.1
9 48.7 48.2 47.8 47.4 13.1 14.3 15 15.8
12 51.2 52.7 52.5 52.1 13.5 14.8 15.5 16.3
15 54.6 53.9 53.6 53.1 13.8 15.1 15.8 16.6
18 57.4 56.5 56 55.6 14.1 15.4 16.2 16.9
21 61 59.9 59.2 58.5 14.3 15.6 16.3 17
24 64 62.5 61.6 61 14.6 15.8 16.8 17.3
NOTA
zona de escarcha.
29
Aplicación T1 - Capacidad de enfriamiento para 20 toneladas nominal
Flujo de aire (CFM) 6400 7000 7600
Ent (DB) (°C) 24 26 30 32 24 26 30 32 24 26 30 32
TC 185.6 188.0 196.5 207.7 190.7 193.1 201.6 212.8 195.8 198.2 206.7 217.9
16 SC 148.8 176.8 188.5 199.2 153.9 181.9 193.6 204.3 159.0 187.0 198.7 209.4
13087.1 13343.7 15919.1 16204.6 13977.6 14237.2 16404.4 16689.9 14868.1 15130.7 16889.7 17175.2
1 7 1 6 6 2 4 9 1 7 7 2
TC 208.2 210.8 213.3 216.3 213.3 215.9 218.4 221.4 218.4 221.0 223.5 226.5
29 20 SC 118.1 144.6 170.0 196.5 123.2 149.7 175.1 201.6 128.3 154.8 180.2 206.7
15361.3 15617.9 18193.3 18478.8 16251.8 16511.4 18678.6 18964.0 17142.3 17404.9 19163.9 19449.3
3 9 3 8 8 4 6 0 3 9 9 3
TC 220.0 224.3 227.3 230.1 225.1 229.4 232.4 235.2 230.2 234.5 237.5 240.3
23 SC 80.8 109.1 132.4 154.6 85.9 114.2 137.5 159.7 91.0 119.3 142.6 164.8
16528.4 16785.0 19060.4 19445.9 17368.9 17628.5 19545.7 19881.2 18209.4 18472.0 20031.0 20316.5
4 0 4 9 9 5 7 2 4 0 0 5
TC 173.9 178.2 186.8 199.3 179.0 183.3 191.9 204.4 184.1 188.4 197.0 209.5
16 SC 141.7 169.9 181.1 193.2 146.8 175.0 186.2 198.3 151.9 180.1 191.3 203.4
14883.2 15139.8 17415.3 17800.8 15723.7 15983.3 17900.6 18236.0 16564.2 16826.8 18385.9 18671.3
2 8 3 8 7 3 6 0 2 8 9 3
TC 194.9 197.8 200.7 204.8 200.0 202.9 205.8 209.9 205.1 208.0 210.9 215.0
35 20 SC 112.6 139.1 165.7 192.2 117.7 144.2 170.8 197.3 122.8 149.3 175.9 202.4
16657.4 16915.0 19189.5 19574.9 17497.9 16679.4
17757.5 19674.7 20010.2 18338.4 18600.0 20160.0 20445.5
5
TC 214.5 217.2 220.1 223.1 219.6 222.3 225.2 228.2 224.7 227.4 230.3 233.3
Temperatura ambiente
23 SC 77.1 104.9 129.8 153.2 82.2 110.0 134.9 158.3 87.3 115.1 140.0 163.4
18324.5 18581.1 20606.6 21092.0 19115.0 19374.6 21091.9 21477.3 19905.5 20168.1 21577.1 21862.6
5 1 6 0 0 6 9 3 5 1 1 6
TC 161.6 166.0 174.6 188.7 166.7 171.1 179.7 193.8 171.8 176.2 184.8 198.9
16 SC 135.1 159.2 167.4 181.0 140.2 164.3 172.5 186.1 145.3 169.4 177.6 191.2
16679.4 16936.0 18961.4 19446.9 17469.9 17729.5 19446.7 19832.2 18260.4 18523.0 19932.0 20217.5
4 0 4 9 9 5 7 2 4 0 0 5
TC 185.6 188.6 192.8 194.3 190.7 193.7 197.9 199.4 195.8 198.8 203.0 204.5
40 20 SC 106.5 133.5 160.2 188.2 111.6 138.6 165.3 193.3 116.7 143.7 170.4 198.4
18953.5 19210.1 21185.6 21671.1 19744.0 20003.6 21670.9 22056.3 20534.5 20797.1 22156.2 22441.6
5 1 6 1 0 6 9 3 5 1 2 6
TC 210.9 212.5 214.0 215.4 216.0 217.6 219.1 220.5 221.1 222.7 224.2 225.6
23 SC 73.2 100.4 126.3 150.5 78.3 105.5 131.4 155.6 83.4 110.6 136.5 160.7
21383.9 21640.5 23438.0 24023.5 22124.4 22384.0 23923.3 24358.8 22864.9 23127.5 24408.6 24694.1
9 5 0 5 4 0 3 8 9 5 6 1
TC 141.2 146.9 161.1 175.3 146.3 152.0 166.2 180.4 151.4 157.1 171.3 185.5
16 SC 123.0 142.2 156.1 169.7 128.1 147.3 161.2 174.8 133.2 152.4 166.3 179.9
18759.7 19016.3 20813.8 21399.3 19500.2 19759.8 21299.1 21734.6 20240.7 20503.3 21784.4 22069.8
7 3 8 3 2 8 1 6 7 3 4 8
TC 168.1 168.0 172.4 175.3 173.2 176.0 177.5 180.4 178.3 184.0 182.6 185.5
46 20 SC 104.5 121.8 148.4 175.3 109.6 126.9 153.5 180.4 114.7 132.0 158.6 185.5
20893.2 20986.5 22897.3 23482.8 21633.7 21893.3 23382.6 23818.1 22374.2 22800.1 23867.9 24153.4
2 5 3 8 7 3 6 1 2 1 9 4
TC 190.5 193.5 196.5 197.8 195.6 198.6 201.6 202.9 200.7 203.7 206.7 208.0
23 SC 62.9 90.0 116.8 142.8 68.0 95.1 121.9 147.9 73.1 100.2 127.0 153.0
23197.7 23454.3 25101.8 25787.3 23888.2 24147.8 25587.1 26072.5 24578.7 24841.3 26072.4 26357.8
7 3 8 3 2 8 1 5 7 3 4 8
NOTA
1. Todas las capacidades son en bruto y no se ha considerado el calor del ventilador interior. Para obtener la capacidad de
enfriamiento NETA restar el calor del ventilador interior.
2. TC= capacidad total (Unidad: 1000Btu/h)
3. SC= capacidad sensible (Unidad: 1000Btu/h)
30 MCCH-R072-240N1
Capacidad de calentamiento para 20 toneladas nominal
Capacidades netas (kW)-7600 CFM
Temp. Exterior (
70%RH 15 20 24 27 15 20 24 27
-9 37.7 36.6 36.2 36.2 15.9 17.3 18.2 19.6
-6 39.7 38.4 38 37.6 16 17.6 18.6 19.9
-3 42.2 41.5 41.2 40.4 16.2 1 7.7 18.9 20.3
0 45.6 44.9 44.2 43.7 16.3 18 19.2 20.4
3 53 52.4 51.6 50.9 16.7 18.3 19.6 20.7
7 65.5 64 59.9 59.5 17.3 19.5 20.3 21.4
9 70.3 69.4 68.6 67.9 18 20 21.3 22.6
12 74.8 77.5 77.2 76.4 18.7 20.9 22.1 23.4
15 80.9 79.7 79.1 78.2 19.2 21.4 22.6 24
18 85.9 84.4 83.4 82.7 19.7 22 23.3 24.4
21 92.4 90.5 89.2 88 20 22.3 23.4 24.7
24 97.8 95.2 93.5 92.4 20.6 22.6 24.3 25.1
NOTA
zona de escarcha.
31
DATOS ELÉCTRICOS
Suministro de energía Compresor Motor del ventilador Motor del ventilador
del evaporador del condensador
Modelo RNC IPT
MCA TOCA MFA STC RNC IPT Cant. RNC IPT Cant. (c/u) (c/u) Cant.
MCCH-R072N1--ACA 23.5 28.9 33.2 75 9.7 5.65 1 7.22 1.62 1 3.65 0.83 1
MCCH-R100N1--ACA 29.4 36.5 43.7 121.2 14.3 8.08 1 7.18 1.61 1 3.93 0.88 1
MCCH-R120N1--ACA 29.6 36.3 47.2 62 8.8 5.13 2 2.90 1.39 1 3.93 0.88 1
MCCH-R140N1--ACA 30.2 37.3 49.4 66 9.6 5.7 2 3.50 1.84 1 2.51 0.98 1
MCCH-R180N1--ACA 41.5 52.9 66.4 64+139 8.3+16.6 4.75+9.16 1+1 4.84 2.03 1 3.66 0.83 1
MCCH-R240N1--ACA 57.4 68.1 90.6 139 16.6 9.16 2 6.60 3.03 1 3.53 0.80 2
32 MCCH-R072-240N1
Modelo 6 toneladas nominal
Presión estática (Pa) Alta velocidad Velocidad Media Velocidad baja
Velocidad del ventilador (RPM) 1001 901 810
0 Entrada de energía (W) 1665 1386 1164
Flujo de aire (CFM) 3001 2647 2356
Velocidad del ventilador (RPM) 1063 972 899
50 Entrada de energía (W) 1607 1341 1133
Flujo de aire (CFM) 2909 2564 2270
Velocidad del ventilador (RPM) 1098 1016 946
80 Entrada de energía (W) 1582 1317 1120
Flujo de aire (CFM) 2825 2503 2190
Velocidad del ventilador (RPM) 1122 1047 977
100 Entrada de energía (W) 1526 1280 1079
Flujo de aire (CFM) 2759 2401 2105
Velocidad del ventilador (RPM) 1173 1106 /
150 Entrada de energía (W) 1452 1230 /
Flujo de aire (CFM) 2560 2250 /
Velocidad del ventilador (RPM) 1219 1162 /
200 Entrada de energía (W) 1375 1182 /
Flujo de aire (CFM) 2367 2109 /
Velocidad del ventilador (RPM) 1265 / /
250 Entrada de energía (W) 1305 / /
Flujo de aire (CFM) 2182 / /
33
Modelo 10 toneladas nominal
NOTA
34 MCCH-R072-240N1
Modelo 12 toneladas nominal
NOTA
35
Modelo 15 toneladas nominal
NOTA
36 MCCH-R072-240N1
Modelo 20 toneladas
NOTA
37
DIAGRAMA DEL CICLO DEL REFRIGERANTE
6 y 8,5 toneladas nominal
Modelo bomba de calor
T3
Condensador
Válvula de 4 vías
Interruptor de
Pistón
alta presión
TP Evaporador
Interruptor de
Comp
baja presión
T2
T3
T3
Válvula de 4 vías Válvula de 4 vías Condensador
Interruptor Interruptor de
de alta presión alta presión
Pistón
Pistón
TP TP
Interruptor de
baja presión Interruptor de baja presión
Comp A
Comp B
Evaporador
T2
T2
38 MCCH-R072-240N1
LÍMITE DE OPERACIÓN
Aplicación T1 50
45
30
25
20
15
10
5
10 15 20 25 30 35
Temperatura interior (°C DB)
Temperatura Temperatura exterior Temperatura interior
Modo
Modo Enfriamiento 10°C~46°C 17°C~31°C
30
25
Condición operativa de calor
20
Temperatura exterior (°C DB)
15
10
-5
-10
-15
-5 0 5 10 15 20 25 30 35
Temperatura interior (°C DB)
NOTA
39
INSTALACIÓN
12.1 Izaje Unidad: mm
instalación de la unidad.
60° 3. Asegurar los conductos al techo.
4. Colocar la unidad sobre la estructura o el borde del
techo.
12.2 Espacio para el mantenimiento 5. Asegurar la unidad a la estructura o borde del techo.
1. El espacio recomendado para las instalaciones de
-
sello impermeable en el lugar de entrada del
eración importante al decidir la ubicación de la
conducto a la estructura.
7. Complete la instalación de acuerdo a las instruc-
ciones.
indicada en estas ilustraciones pueden originar una Aplicación típica de techo con estructura
40 MCCH-R072-240N1
13.4 A nivel del piso – Unidades horizontales 13.5 Instalación de la cañería de desagüe del con-
Para las instalaciones a nivel del piso la unidad se densador
procedimiento:
sumi-
nistro a la unidad.
41
NOTA Selección del tamaño de los cables y el fusible para la
fuente principal de energía.
sólidos.
Unidad
motor del ventilador del condensador y la corriente
Conducto en el emplazamiento
unidad deberá estar determinado de acuerdo a la sigu-
cableado a tierra.
Componentes requeridos
42
CONTROL REMOTO CON CABLE Descripción de iconos
Icono
Control por cable estándar: KJR-12B/DP (T)-E
caracteres a un lado.
Advertencia
ADVERTENCIA
Instalación delegada
Por favor encomiende a un profesional o distribui-
dor la instalación de la unidad. Estos profesionales
PRECAUCIONES DE SEGURIDAD
ADVERTENCIA DE USO
-
piado puede provocar muerte y Condiciones de uso
PRECAUCIÓN
-
piado puede provocar lesiones o 2. Temperatura de operación: -15ºC-+43ºC
CUIDADO pérdida de la propiedad.
NOTA
1.
eléctrica
pero no la hospitalización.
-
dad y materiales.
43 MCCH-R072-240N1
RESUMEN DE LAS FUNCIONES
Función principal
Función Follow me
del ventilador
Temporizador ON/OFF
Zona de visualización de temperatura
de lo contrario desaparece.
Calentamiento Solo venti-
lador 5. Indicación de la velocidad del ventilador
omite el modo calentamiento.
- 6. Bloqueo
3. Función Follow me
7. Zona de visualización de temperatura
las dos temperaturas y el espacio del control por cable se puede ajustar presionando el botón de ajuste de
temperatura y
- el display.
tamiento.
44
MÉTODO DE INSTALACIÓN 1. Botón de modo
AUTO
Control por cable
(automático) (enfriamiento
NOTA
Cable blindado
de 5 hilos
modo calentamiento.
Tablero del
interruptor interior
Unidad interior
2. Botón del temporizador On
Presione este botón y se activará al función tempori-
infrarrojo con una pistola de agua cerca al receptor en
4. Botón follow me
45 MCCH-R072-240N1
interior. Cuando este encendido presione este botón tiva este modo (esta función puede no ser efectiva
y el indicador estará en Off y enviará instrucciones. Si para algunos modelos).
este ajuste y luego enviará instrucciones para detener 12. Botón de velocidad del motor
el aparato. Presione este botón consecutivamente y la velocidad
del ventilador girará de la siguiente manera:
8. Botón de ajuste
9. Botón de ajuste
46
MÉTODO DE USO
Operación automática nuevo el botón ON/OFF y la función se detendrá.
interior.
auto.
temporizador On.
NOTA a 1h.
ninguna temperatura.
47 MCCH-R072-240N1
NOTA
Cambio del temporizador una demora luego de la hora de ajuste (por ejem-
plo la hora de ajuste es 8:05 AM). Por lo tanto
presione el botón correspondiente para revisar la hora.
Si la hora del temporizador se cancela la hora se hora estándar.
cambia a 0.0.
CÓDIGO DE ERROR
14.1 Código de error para 6 y 8.5 toneladas nominal
48
Error de código para 10 toneladas nominal y superior
49 MCCH-R072-240N1
SOLUCIÓN DE PROBLEMAS
1) 0: Error en la secuencia de la fase del compresor o incumplimiento de la fase
es normal.
No
Si
No
Si
No
Si
Reemplace
el tablero principal.
Detecte si la temperatura
del sensor es normal.
Si No
50
3) E9: Incumplimiento T2 del sensor de temperatura de la serpentina interior
Si No
si los terminales T2_1, T2_2, T3_2, T4 están conectados a un circuito corto. Si no sucede eso por favor
conecte todo a un circuito corto a menos que reemplace el tablero principal
5) Eb: Error de salida del control por cable. (Solo para KJR-23B o KJR-25B)
Evite las siguientes tres condiciones:
6) P0: Protección de sobre corriente del compresor. (El valor de protección de sobre corriente es 16A)
Si No
51 MCCH-R072-240N1
7) P3: Protección completa para el ventilador exterior
Si
No
el protector de tres fases COM y si no Reemplace el protector de tres fases
y vuelva hacer la detección.
Si
8) P4: Protector para presión alta/baja o temperatura de escape (Valor de protección de alta presión: 4.4MPa,
Valor de protección de alta presión: 0.14MPa; Valor de protección de temp. de descarga de aire; por encima
de 130ºC)
Si
No
el interruptor de alta/baja presión laterales y el Reemplace el interruptor de alta/baja presión
interruptor de descarga de aire de los laterales
detecte nuevamente.
Si
52
9) El motor del ventilador interior no funciona
No
Reemplace el tablero principal.
principal al ventilador interior.
Si
No
detéctelo nuevamente. Controle si el ventilador Reemplace el ventilador interior.
interior funciona.
Si
Elimine el problema.
No
Reemplace el tablero principal.
Si
No
detéctelo nuevamente. Controle si el ventilador
Si
Elimine el problema.
53 MCCH-R072-240N1
1. El motor del ventilador interior no funciona.
-
mación.
No
No
Si No
Si No Si No
Reemplace el Reemplace el
Reemplace el motor.
Contactor. fusible. tensión secundario es normal.
Si No
Reemplace Reemplace el
PCB transformador
54
es el rango requerido. Si el compresor no funciona, Ud. puede analizar lo siguiente)
COMP2 y N.
Si No
Si No Si No
Si No
Reemplace Reemplace el
PCB transformador
respuesta al Apéndice 1?
Si No
Si No
Reemplace PCB.
55 MCCH-R072-240N1
5. El motor del ventilador exterior está dañado.
OVENT2 y N.
Si No
Si No Si No
Si No
Reemplace Reemplace el
PCB transformador
Si No
Detecte si el fusible en
o la serpentina.
Si No
Reemplace el
fusible tensión secundario es normal.
Si No
Reemplace Reemplace el
PCB transformador
56
7. Protección de alta temperatura del condensador.
Si Reemplace el sensor
Si
Eliminar el problema
No
Eliminar el problema
del manómetro.
No
Eliminar el problema
No
57 MCCH-R072-240N1
MANTENIMIENTO Y CUIDADO
Mantenimiento y cuidado normal
El mantenimiento y cuidado normal de algunos com-
Caja de control
de tensión.
Panel de acceso
a la caja de control
NOTA
Se deberá colocar una capa resistente al fuego de
58
APÉNDICE
Tabla de Valor de Resistencia del Sensor de Temp. de la Cañería y Temp. Interior (8.5 toneladas nominal y
superior)
°C K Ohm °C K Ohm °C K Ohm °C K Ohm
-20 115.266 20 12.6431 60 2.35774 100 0.62973
-19 108.146 21 12.0561 61 2.27249 101 0.61148
-18 101.517 22 11.5000 62 2.19073 102 0.59386
-17 96.3423 23 10.9731 63 2.11241 103 0.57683
-16 89.5865 24 10.4736 64 2.03732 104 0.56038
-15 84.2190 25 10.000 65 1.96532 105 0.54448
-14 79.3110 26 9.55074 66 1.89627 106 0.52912
-13 74.5360 27 9.12445 67 1.83003 107 0.51426
-12 70.1698 28 8.71983 68 1.76647 108 0.49989
-11 66.0898 29 8.33566 69 1.70547 109 0.48600
-10 62.2756 30 7.97078 70 1.64691 110 0.47256
-9 58.7079 31 7.62411 71 1.59068 111 0.45957
-8 56.3694 32 7.29464 72 1.53668 112 0.44699
-7 52.2438 33 6.98142 73 1.48481 113 0.43482
-6 49.3161 34 6.68355 74 1.43498 114 0.42304
-5 46.5725 35 6.40021 75 1.38703 115 0.41164
-4 44.0000 36 6.13059 76 1.34105 116 0.40060
-3 41.5878 37 5.87359 77 1.29078 117 0.38991
-2 39.8239 38 5.62961 78 1.25423 118 0.37956
-1 37.1988 39 5.39689 79 1.21330 119 0.36954
0 35.2024 40 5.17519 80 1.17393 120 0.35982
1 33.3269 41 4.96392 81 1.13604 121 0.35042
2 31.5635 42 4.76253 82 1.09958 122 0.3413
3 29.9058 43 4.57050 83 1.06448 123 0.33246
4 28.3459 44 4.38736 84 1.03069 124 0.32390
5 26.8778 45 4.21263 85 0.99815 125 0.31559
6 25.4954 46 4.04589 86 0.96681 126 0.30754
7 24.1932 47 3.88673 87 0.93662 127 0.29974
8 22.5662 48 3.73476 88 0.90753 12 8 0.29216
9 21.8094 49 3.58962 89 0.87950 129 0.28482
10 20.7184 50 3.45097 90 0.85248 130 0.27770
11 19.6891 51 3.31847 91 0.82643 131 0.27078
12 18.7177 52 3.19183 92 0.80132 132 0.26408
13 17.8005 53 3.07075 93 0.77709 133 0.25757
14 16.9341 54 2.95896 94 0.75373 134 0.25125
15 16.1156 55 2.84421 95 0.73119 135 0.24512
16 15.3418 56 2.73823 96 0.70944 136 0.23916
17 14.6181 57 2.63682 97 0.68844 137 0.23338
18 13.9180 58 2.53973 98 0.66818 138 0.22776
19 13.2631 59 2.44677 99 0.64862 139 0.22231
59 MCCH-R072-240N1
Tabla de Valor de Resistencia del Sensor de Temp. de la Cañería y Temp. Interior (6 toneladas nominal)
60
Temp Resistencia (K ) Resist.tol (%) Temp.tol (°C)
(°C) Rmax R(t)
)Normal Rmin MAX(+) MIN(-) MAX(+) MIN(-)
29 8.621 8.337 8.055 3.41 3.38 0.77 0.74
30 8.252 7.972 7.695 3.51 3.47 0.80 0.77
31 7.900 7.625 7.353 3.61 3.57 0.83 0.79
32 7.566 7.296 7.029 3.70 3.66 0.85 0.82
33 7.247 6.982 6.721 3.80 3.74 0.88 0.84
34 6.944 6.684 6.428 3.89 3.83 0.91 0.87
35 6.656 6.401 6.150 3.98 3.92 0.93 0.90
36 6.381 6.131 5.886 4.08 4.00 0.96 0.93
37 6.119 5.874 5.634 4.17 4.09 0.98 0.95
38 5.870 5.630 5.395 4.26 4.17 1.01 0.98
39 5.631 5.397 5.167 4.34 4.26 1.03 1.01
40 5.404 5.175 4.951 4.43 4.34 1.06 1.03
41 5.188 4.964 4.745 4.52 4.42 1.09 1.06
42 4.982 4.763 4.549 4.60 4.50 1.12 1.09
43 4.785 4.571 4.362 4.69 4.58 1.14 1.12
44 4.596 4.387 4.183 4.77 4.66 1.17 1.14
45 4.417 4.213 4.014 4.85 4.74 1.19 1.17
46 4.246 4.046 3.851 4.93 4.81 1.22 1.20
47 4.082 3.887 3.697 5.02 4.89 1.25 1.23
48 3.925 3.735 3.550 5.10 4.97 1.28 1.25
49 3.776 3.590 3.409 5.18 5.04 1.30 1.28
50 3.632 3.451 3.274 5.25 5.12 1.33 1.30
51 3.495 3.318 3.146 5.33 5.19 1.35 1.33
52 3.363 3.191 3.023 5.41 5.26 1.41 1.36
53 3.237 3.069 2.905 5.49 5.34 1.43 1.38
54 3.116 2.952 2.793 5.56 5.41 1.46 1.41
55 3.001 2.841 2.685 5.64 5.48 1.48 1.44
56 2.890 2.734 2.582 5.71 5.55 1.51 1.46
57 2.784 2.632 2.484 5.79 5.62 1.54 1.49
58 2.682 2.534 2.390 5.86 5.69 1.56 1.52
59 2.585 2.440 2.299 5.93 5.76 1.59 1.54
60 2.491 2.350 2.213 6.01 5.83 1.62 1.57
61 2.401 2.264 2.130 6.08 5.90 1.64 1.60
62 2.315 2.181 2.051 6.15 5.96 1.67 1.62
63 2.233 2.102 1.975 6.22 6.03 1.70 1.65
64 2.154 2.026 1.903 6.29 6.10 1.72 1.68
65 2.077 1.953 1.833 6.36 6.1 6 1.75 1.70
66 2.004 1.883 1.766 6.42 6.23 1.77 1.73
67 1.934 1.816 1.702 6.49 6.29 1.80 1.76
68 1.867 1.752 1.641 6.56 6.35 1.83 1.78
69 1.802 1.690 1.582 6.62 6.41 1.85 1.81
70 1.740 1.631 1.525 6.69 6.48 1.88 1.84
71 1.680 1.574 1.471 6.75 6.54 1. 91 1.86
72 1.622 1.519 1.419 6.82 6.60 1.93 1.89
73 1.567 1.466 1.369 6.88 6.66 1.96 1.92
74 1.514 1.416 1.321 6.94 6.71 1.98 1.94
75 1.463 1.367 1.275 7.00 6.77 2.01 1.97
61 MCCH-R072-240N1