Webinar Sobre QAQC-20220712
Webinar Sobre QAQC-20220712
Webinar Sobre QAQC-20220712
9.00
8.00
7.00 A1 vs A2
A1 vs A3
45
6.00 -10%
Duplicate (g/t)
10%
A2 vs A3
A1 vs A4
5.00 A2 vs A4
A3 vs A4
-30%
30%
4.00
Control Chart Standard STD 14P - Ni / February 2008
3.00 Las Aguilas-QA/QC Review Outliers Excluded
3.0
2.00
Data
1.00
2.5 Mean +/- 2
STD 14P, Ni (%)
0.00 std.dev.s
0.00 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00 9.00 10.00 11.00 12.00 13.00 14.00 15.00
Best Value
Original (g/t) 2.0
Moving Average
1.05 x Best
Fig. 2. Reproducibility of Pulp Duplicates. Low grades.
1.5 0.95 x Best
Especificaciones básicas
OSC, 2011. Repeal and Replacement of National Instrument 43-101 Standards of Disclosure for
Mineral Projects, Form 43-101f1 Technical Report, and Companion Policy 43-101cp
Webinar sobre QA/QC en la Exploración Geológica
La Persona Calificada - NI 43-101
Organizaciones
Extranjeras
Aceptadas
por NI 43-101
(2011)
Especifica las normas que establecen los requerimientos formales mínimos a ser
exigidos sobre los prospectos de exploración, recursos, y reservas mineras para
propósitos de información pública y de los mercados de capitales.
80.00
70.00
60.00
A1 vs A2
A1 vs A3
45
-10%
50.00 10%
Duplicate (g/t)
A2 vs A3
A1 vs A4
A2 vs A4
40.00 A3 vs A4
-30%
30%
30.00
20.00
10.00
0.00
0.00 10.00 20.00 30.00 40.00 50.00 60.00 70.00 80.00 90.00 100.00 110.00 120.00
Original (g/t)
9.00
8.00
7.00 A1 vs A2
A1 vs A3
45
6.00 -10%
Duplicate (g/t)
10%
A2 vs A3
A1 vs A4
5.00 A2 vs A4
A3 vs A4
-30%
4.00 30%
3.00
2.00
1.00
0.00
0.00 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00 9.00 10.00 11.00 12.00 13.00 14.00 15.00
Original (g/t)
+ 10 % - 10 %
Au in Internal Pulp Duplicate (g/t)
PD
2
45º Line
+10% Line
-10% Line
Lineal (PD)
0
0 1 2 3 4 5
Definición
Objetivo Final
La prevención de problemas
(que se supone que podrían
eventualmente ocurrir)
¿Cómo se materializa?
Drilling (1)
The drilling method will be selected by a QP(s) and should be
appropriate to the material being investigated, the objective of the
program and local drilling conditions. The drill hole size selected
should provide sufficient representative sample material for analysis
and reference. Surface and downhole locational surveys should be
undertaken using techniques appropriate for the hole size, angle and
length of holes. A representative fraction of the drill sample material
should be retained; however, if material is not retained, the QP(s)
should report and explain the reason for this decision.
Drilling (2)
Drill logs, forms or software specifically suited to the type of drilling,
the particular geological situation, and the minerals being sought,
should be used for detailed geological logging of core or cuttings.
Logs should be appropriately detailed for the type of drilling being
conducted, the geological setting, type of mineralization, and
geotechnical conditions.
Sampling
The practices and procedures used in each sampling program should
be appropriate for the objectives of the program. All sampling
programs should be carried out in a careful and diligent manner using
scientifically established sampling practices designed and tested to
ensure that the results are representative and reliable. Samples should
be collected under the supervision of a QP(s). Quality control
programs appropriate to the type of sample and the mineralization
should be planned and implemented. These programs should include
such measures as external blanks, standards and duplicate samples.
Where the volume of individual samples is reduced prior to shipping to
a laboratory for analysis, appropriate reduction procedures to obtain
representative subsamples should be applied and verified.
Sample Preparation
The selection of sample preparation procedures should be approved
by the QP and should be appropriate to the material being tested, the
elements being analyzed and should be subject to the security
measures as stated above. All samples that are reduced or split
should be processed in a manner such that the fraction analyzed or
tested is as representative of the whole sample as possible.
Representative fractions of the material to be analyzed or tested
should be retained for an appropriate period of time, as decided by
the QP. Quality control checks should be undertaken as determined
by the QP.
Sample Assaying
Analysis and testing of samples should be done by a reputable and
preferably accredited laboratory qualified for the particular material to be
analyzed or tested. The selection of a laboratory, testing or mineral
processing facility and the analytical methods used will be the
responsibility of the QP. The analytical methods chosen must be
documented and justified. All analytical or test results should be supported
by duly signed certificates or technical reports issued by the laboratory or
testing facility and should be accompanied by a statement of the methods
used. The reliability of the analytical and testing results should be
measured using the results of the quality control samples inserted in the
process by the QP. Duplicate analyses at other laboratories should be
undertaken.
Definición
Objetivo Final
¿Cómo se materializa?
Precisión
• La habilidad de repetir consistentemente los resultados de una
medición en condiciones similares
Exactitud
• La proximidad de una medición a un valor “real” o aceptado
como “apropiado”
Contaminación
• La transferencia involuntaria de material de una muestra o del
medio circundante a otra muestra
Precisión y Exactitud
Precisión y Exactitud
Se debe a la ocurrencia de
➢ Errores Aleatorios
➢ Errores Sistemáticos
Errores Aleatorios
Errores Sistemáticos
Tipos de Errores
Error sistemático
Errores groseros
Error aleatorio
Errores Groseros
Segunda aproximación
¿Cómo actúa?
Muestreo Representativo
Errores en el muestreo
Webinar sobre QA/QC en la Exploración Geológica
La Calidad del Muestreo
Errores en el muestreo
Webinar sobre QA/QC en la Exploración Geológica
La Calidad de la Preparación
Preparación
División de 400 g
Pulverización a
95%-0.106 mm
Ejemplo de Nomograma de
División de 200 g: ????
Preparación
Muestras con Metales
Toma División de 100 g: ERROR
de Básicos
alícuota
de 0.5 g (Cu, Pb, Zn, Mo, etc.)
Errores frecuentes
en la preparación de las muestras
Precisión
Repetición de acciones en
Precisión condiciones tan cercanas a las
originales como sea posible:
DUPLICADOS
Ejemplos de uso:
baja o alta precisión, precisión aceptable
Regresion Line
3.00
Cu in Twin Samples (%)
- 30 %
TS
2.00 45º Line
+30% Line
-30% Line
Lineal (TS)
1.00
0.00
0.00 1.00 2.00 3.00 4.00
Cu in Original Samples (%)
precisión no tiene en
cuenta el sentido de las
desviaciones, sino su
magnitud o valor
absoluto.
2 * |Vo-Vd|
ER= -------------------
(Vo+Vd)
Valor Mínimo
Webinar sobre QA/QC en la Exploración Geológica
Control de la Calidad
y = mx
y=x
Valor Máximo
Valor Mínimo
Webinar sobre QA/QC en la Exploración Geológica
Control de la Calidad
4 41135
Max Cu (%)
TS
45º Line
Failure Line-30% Rel. Error
3
Failures
39101
41946
39530
2 39465
41985
39705
40987
38866
41465
1 41738
40866
0
0 1 2 3 4 5 6 7
Min Cu (%)
41465
0.9
0.8 41738
y=mx
42788
0.7
0.6 40866
Max Cu (%)
0.5 TS
45º Line
Failure Line-30% Rel. Error
0.4
Failures
0.3
0.2
Menor Precisión
0.1
cerca del
0.0
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Limite de Detección
Min Cu (%)
10
8
Max CuT (%)
PD
45º Line
6 Failure Line
Failures
4
Number of samples
81
Failures
2
6 7.4%
0
0 2 4 6 8 10 12
Min CuT (%)
5.5
5.0
4.5
4.0
3.0 PD
45º Line
2.5 Failure Line
Failures
2.0 Number of samples
1979
1.5
Failures
1.0 54 2.7%
0.5
0.0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5
Min Cu (%)
y = 0.9926x + 0.0204
Cu in Coarse Duplicates R2 = 0.9749
+ 20 %
45º Line
4.00
- 20 %
Cu in Coarse Duplicates (%)
3.00
CD
Regresion Line 45º Line
+20% Line
2.00
-20% Line
Lineal (CD)
1.00
0.00
0.00 1.00 2.00 3.00 4.00
Cu in Original Samples (%)
6
Max CO3 (%)
CD
45º Line
4 Failure Line
Failures
Number of samples
2 116
Failures
22 19%
0
0 2 4 6 8
Min CO3 (%)
Webinar sobre QA/QC en la Exploración Geológica
Control de la Calidad
Duplicados Gruesos – ER = 20% : y2 = m2x2 + b2
(All Samples)
Max Au (DD) (ppm)
FD
45º Line
2
Failure Line
Failures
Number of samples
960
1 Failures
107 11.1%
0
0 1 2 3 4
Min Au (DD) (ppm)
1.0
0.8
(All Samples)
Max Au (RC) (ppm)
FD
0.6 45º Line
Failure Line
Failures
Number of samples
0.4
130
Failures
16 12.3%
0.2
0.0
0 0 0 1 1 1 1
Min Au (RC) (ppm)
LD: 0.001 % Cu
LPD: 0.010 % Cu
LD: 0.001 % Cu
LD: 0.005 %
Webinar sobre QA/QC en la Exploración Geológica
Control de la Calidad
Investigación de Errores: Ejemplo Práctico 6b
LPD: 0.010 %
Webinar sobre QA/QC en la Exploración Geológica
Control de la Calidad
No más de 10% de los pares de muestras debe quedar fuera del campo delimitado
por la línea y=x y la hipérbola y2=m2x2+b2, con pendiente m de la asíntota
calculada para b=0 y errores relativos (ER) según el tipo de muestra:
(Min, Max) TS
45º Line b: Max ≤ Hip = OK
Failure Line-30% Rel. Error
3
Failures
39101
41946 (Min, Hip)
39530
2 39465
41985
39705
40987
38866
41465
1 41738
40866
0
0 1 2 3 4 5 6 7
Min Cu (%)
Exactitud
En el mismo laboratorio:
▪https://en.wikipedia.org/wiki/Estimator
Webinar sobre QA/QC en la Exploración Geológica
Control de la Calidad
Evaluación de la Exactitud
Criterio de Aceptación
El sesgo resultante del análisis, una vez excluidos los valores fuera de
control, debe encontrarse dentro de los límites aceptables:
El Gráfico de Control
El gráfico de control fue inventado por Walter A. Shewhart en los años 1920s,
mientras trabajaba para Bell Labs, con el fin de mejorar la confiabilidad de los
sistemas de transmisión telefónica.
Walter A. Shewhart
Inventor del gráfico de control
https://en.wikipedia.org/wiki/Control_chart
Webinar sobre QA/QC en la Exploración Geológica
Control de la Calidad
El Gráfico de Control
En mayo de 1924, Shewhart escribió un memorándum interno de apenas una
página en el que propuso el gráfico de control como herramienta para
distinguir entre dos tipos de variaciones en un proceso, que llamó de causa
común y de causa especial. Un tercio de la página contenía lo que hoy
conocemos de modo esquemático como gráfico de control.
Shewhart concluyó que todo proceso presenta variaciones, pero alguna son
variaciones controladas, naturales al proceso (de causa común), mientras que
otras son variaciones no controladas, que no están presentes todo el tiempo
(de causa especial).
El Gráfico de Control
Los gráficos de control se usan para:
https://asq.org/quality-resources/control-chart
Webinar sobre QA/QC en la Exploración Geológica
Control de la Calidad
El Gráfico de Control
En un gráfico de control, los datos deben ser ploteados en una secuencia
temporal.
https://asq.org/quality-resources/control-chart
Webinar sobre QA/QC en la Exploración Geológica
Control de la Calidad
Precisión y Exactitud
https://asq.org/quality-resources/control-chart
Webinar sobre QA/QC en la Exploración Geológica
Control de la Calidad
- Por otro lado, si un dato fuera de control es provocado por una causa
especial, puede que no sea de suficiente magnitud como para demandar
acciones correctivas inmediatas.
https://en.wikipedia.org/wiki/Control_chart
Webinar sobre QA/QC en la Exploración Geológica
Control de la Calidad
Aparentes Contradicciones
¿Qué sentido tiene preparar gráficos de control para evaluar la exactitud si los límites de
control se fijan a partir de la desviación estándar, que es un parámetro relacionado con la
precisión?
https://asq.org/quality-resources/control-chart
Webinar sobre QA/QC en la Exploración Geológica
Control de la Calidad
Aparentes Contradicciones
¿Qué sentido tiene preparar gráficos de control para evaluar la exactitud si los límites de
control se fijan a partir de la desviación estándar, que es un parámetro relacionado con la
precisión?
El gráfico de control no fue concebido para evaluar la exactitud, sino la precisión del proceso de
medición. Cada análisis del material de referencia es un duplicado de sí mismo. En el análisis
del material de referencia en el laboratorio, es posible evaluar la precisión mediante el
coeficiente de variación, que debe ser preferiblemente menor o igual a 5%.
Para identificar los valores fuera de control, que deben ser excluidos del cálculo del sesgo, es
decir, de la evaluación de la exactitud.
https://asq.org/quality-resources/control-chart
Webinar sobre QA/QC en la Exploración Geológica
Control de la Calidad
Gráfico de Control
Límite de
Medición
control superior
Promedio
Límite de
control inferior
Tiempo
Promedio y límites de control calculados a partir de los datos realmente
obtenidos durante el experimento
Correcto: Ajustado al Proceso!!!
Webinar sobre QA/QC en la Exploración Geológica
Control de la Calidad
Gráfico de Control
MV + 3σ
Medición
MV
MV - 3σ
Tiempo
Línea central y límites de control tomados
de los datos del certificado del material de referencia
MR: material de refêrencia; Médiaso: média depois de excluir as AFC; MV: melhor valor; AFC: amostras fora de controle
Webinar sobre QA/QC en la Exploración Geológica
Control de la Calidad
En otro laboratorio
Contaminación
• La transferencia involuntaria de material de una muestra o del
medio circundante a otra muestra
Durante el análisis
Criterios de Aceptación
140
120
100
80
Blank
60
40
20
0
0 200 400 600 800 1000 1200 1400 1600
I (p p m)
Pr e ce ding Sam ple Saf eV alue
Lineal (I (p p m))
2.5
2.0
Blank1.5
1.0
0.5
0.0
0 5 10 15 20 25 30
Pr e ce ding Sam ple NaNO3 (%)
Saf e V alue
Lineal (NaNO3 (%))
0.9
0.8
0.7
0.6
0.5
Blank
Bi
0.4 Safe Limit
Regression
0.3
0.2
0.1
0.0
0 100 200 300 400 500 600
Preceding Sample
140
120
100
Blanco
80
60
40
20
0
0 1000 2000 3000 4000 5000 6000 7000 8000
Lineal (M o (ppm))
Duplicados de pulpa** DP 2%
Materiales de referencia** MR 6% MRs (6%)
Blancos gruesos* BG 2%
Blancos (4%)
Blancos finos** BF 2%
Controles Externos*** CE 4% Controles Externos (4%)
* Para ser analizadas en el laboratorio primario
** Para ser analizadas en los laboratorios primario y secundario
*** Para ser analizadas en el laboratorio secundario (las cifras no incluyen las muestras de control de
estos lotes, las que deben ser consideradas de modo adicional)
Tomado de Simón (2007)
Webinar sobre QA/QC en la Exploración Geológica
¿Qué hacer cuando aparecen errores?
En todos los casos
•Identificar posibles errores groseros (revisar el “ADN” o la “huella digital”,
cotejar con muestras vecinas y/u otros materiales de referencia)
Muestras Gemelas
• Chequear físicamente los intervalos de muestreo
Duplicados en General
• No repetir las muestras fallidas; se debe investigar la causa probable y
corregir el problema en la medida de lo posible
Materiales de Referencia
• Repetir las muestras con problemas y algunas muestras vecinas, o incluso
del lote entero, si es necesario
Blancos
• Requerir mejoras en procedimientos de preparación y análisis
SÓLO EL ORIGINAL