Planta Estructura de Techos + Losas: Escala 1:75
Planta Estructura de Techos + Losas: Escala 1:75
Planta Estructura de Techos + Losas: Escala 1:75
RT
E
1 2 3
4.85 25.25
19.95 5.15
4.43 4.43 4.43 4.43 4.44 4.43
C
0.77
EMPARILLADO NO. 3 @ 0.15 MTS.
0.96
REF. NO. 3 @ 0.18 MTS.
1.25 1.25
4.00
Indica solera corona 1.00 1.00
0.96
TIPO "C" DE 2" * 3"
0.77
B
10.00
Emparrillado No.3 @ 0.15 S = 29 %
S = 29 %
5.85
CUBIERTA
LAMINA TROQUELADA CAL. 28
A
PLANTA
Escala 1:75
estructura de techos + losas
ACERO: CARGAS:
1- EL ACERO DEBERA TENER UN f'y = 2,800 Kg/cm2 1- CONCRETO: 2,400 Kg/Cm3
2- GANCHOS DIAMETRO MINIMO DE DOBLEZ PARA VARILLAS DEL 2- VIVA TECHO 150 kg/Cm3
No. 3 AL No. 8, 6 DIAMETROS DE LA VARILLA 3- SOBRE CARGA 15 Kg/Cm2
3- LONGITUD DE VARILLAS SUJETAS A TENSION Y TRASLAPES 4- MUROS 200 Kg/Cm2 CENEFA
No. 3 = 0.30 mTS. DE PVC
nO. 4 = 0.30 Mts. CENEFA
No. 5 = 0.36 Mts. DE PVC
4- TODAS LAS VARILLAS SE DOBLARAN EN FRIO NOTAS: PERNO
5- CODIGOS DE DISEÑO, ACI 318 - 71 Ø=1/2''
S.A. = SOLERA DE AMARRE
S.H. = SOLERA HIDRÓFUGA ESTRUCTURA DE ALUMINIO ESTRUCTURA DE ALUMINIO
C-1 = COLUMNA TIPO UNO
MUROS: Z-1 = ZAPATA TIPO
DE 3" * 2" DE 3" * 2"
1- LOS MUROS SE LEVANTARAN CON BLOCK DE 0.14 X 0.19 X 0.39 Mts. CC-1 = CIMIENTO CORRIDO TIPO UNO
UNIDOS CON SABIETA EN PROPORCION 1:3 (cemento + arena de río) V-1 = VIGA AEREA TIPO UNO HOJA DE:
2- EL PESO DE LOS MUROS SERA IGUAL A 200 Kg/cm2
ESTRUCTURA DE TECHOS + LOSAS
CONCRETO:
SOLERA
+ DETALLE DE CENEFA
1- EL CONCRETO DEBERA TENER UN f'c = 210 Kg/cm2
SOLERA VER DETALLE EN HOJA 4/10
2- LA RELACION AGUA CEMENTO MÁXIMA PERMISIBLE 29.3 Lts/Sc DE CEMENTO
3- EL AGREGADO GRUESO DEBERA TENER UN DIÁMETRO MÍNIMO DE 1/2" Y MÁXIMO VER DETALLE EN HOJA 4/10
PROYECTO:
DE 1,1/2" FECHA: DIBUJO:
4- RECUBRIMINETOS MÍNIMOS: NOVIEMBRE 2022 SALON DE EVENTOS L.A.D.V
HOJA NO.
6
PROPIETARIO PLANIFICADOR
DE: 10