FAULTS AND PROTECTION SYSTEM

Professor: MsC. Jorge Ivan Silva Ortega


Electrical and electronic Engineer
Energetic

WEEK 3
TOPIC 1: CONCEPTS OF
PROTECTION SYSTEMS
Concept 12: ANSI/IEEE
protection function
Concept 12: ANSI/IEEE
protection function
Concept 12: ANSI/IEEE
protection function
Concept 12: ANSI/IEEE
protection function
Concept 12: ANSI/IEEE
protection function
Concept 12: ANSI/IEEE
protection function
Concept 12: ANSI/IEEE
protection function
Concept 12: ANSI/IEEE
protection function
Concept 12: ANSI/IEEE
protection function
Concept 12: ANSI/IEEE
protection function
Concept 13: Measurement
Transformer
Concept 13: Measurement
Transformer
Concept 13: Measurement Transformer

Potential transformer
Concept 13: Measurement Transformer

Precision error (TP)


Concept 13: Measurement Transformer

Current transformer
Concept 13: Measurement Transformer

COMBINED TRANSFORMERS
Concept 13: Measurement Transformer

COMBINED TRANSFORMERS
Concept 14: DC POWER
BATTERIES
Concept 15:
Switch (disyuntor o interrputor)
Concept 15:
Switch (disyuntor o interrputor)
CONCLUSIONES DE ESTA
ETAPA
• Se presentaron 15 conceptos introductorios
al curso de fallas y cortocircuitos.

• Estos conceptos serán utilizados y


considerados durante el desarrollo del curso y
se recomienda su total conceptualización.

• Se asignó tarea para la conceptualización de


los tipos de relés y su aplicación.
FAULTS AND PROTECTION SYSTEM
Professor: MsC. Jorge Ivan Silva Ortega
Electrical and electronic Engineer
Energetic

WEEK 6
TOPIC 2: FAULTS & SHORTCIRCUITS
Concept 1: sequence Networks
TEOREMA DE FORTESCUE: Tres fasores desbalanceados de un
sistema trifásico se pueden descomponer en tres sistemas
balanceados. Estos conjuntos balanceados son:

• Componentes de secuencia positiva: están formados por tres


fasores de igual módulo, desfasados en 120 ° que giran con
secuencia positiva (ABC),igual al sistema principal.

• Componentes de secuencia negativa: están formados por tres


fasores de igual módulo, desfasados en 120 ° que giran con
secuencia negativa (ACB), contrario al sistema principal.

• Componentes de secuencia cero: están formados por tres vectores


de igual módulo, pero en fase.
Concept 1: sequence Networks
• En condiciones normales un sistema únicamente
tiene una sola secuencia, “La secuencia positiva”.

• Si existen secuencias cero es debido a que el


neutro está conectado a la tierra.

• La secuencia negativa representa los aportes que


el sistema realiza con la posible conexión de otras
dos líneas.
Concept 1: sequence Networks
Concept 1: sequence Networks
Concept 2: Sequence Network
assembling
• The reactance of positive and negative sequence are equal each
other.
• The reactance of sequence cero is different according of the type
GENERADORES
of generation.

• The reactance of positive and negative sequence are the same


• The reactance of cero sequence could be the same as positive and negative
sequence or it could be infinite.
TRANSFORMERS • The resistance value of the windings (Devanados) is not considered due to is
approximately cero.

• The impedance of positive and negative sequence are the same.


• The impedance of cero sequence is 2,5 the impedance of
LINES positive sequence.
Concept 2: Sequence Network
assembling
Concept 2: Sequence Network
assembling
Concept 2: Sequence Network assembling

Falla Trifasica
Concept 2: Sequence Network assembling

Falla Bifasica
Concept 2: Sequence Network assembling

Falla Monofasica
Concept 2: Sequence Network assembling

Falla Bifasica a Tierra


Concept 2: Sequence Network assembling

Resumen de conexiones
Concept 3: P.U. Values
Concept 3: P.U. Values
• Justificación
1) Se reduce la dificultad de cálculo al manejar unidades del
orden M o k.
2) Facilidad de análisis. Poder interpretar los datos partes de un
unifilar.
3) El llevar todo a un sistema de impedancias equivalentes
permitirá cálculos y procedimientos más rápidos.
4) Fácil identificación de condiciones nominales del Sistema.
Ejemplo: valores de referencia máximos o mínimos.
• Tensión nominal: 0,9 < Vn (pu) < 1,05 (90% < Vn (%) < 105%
• Cargabilidad: 125% 1,25 pu
Concept 3: P.U. Values
EJERCICIO COMPLETO

ZONA 1
ZONA 2

ZONA 3
CALCULO DE VALORES BASES
Valor Base ZONA 1 ZONA 2 ZONA 3
Sbase (MVA) 50 50 50
Vbase (kV) 115 13,8 34,5
Ibase (A) 251,022 2091,849 836,740
Zbase (ohm) 264,5 3,8088 23,805

• Procedimiento.
1. Definir las zonas del sistema, las cuales están distribuidas
por nivel de tensión presente.
2. Definir S(base) = y V(base)
3. Convertir todos los elementos presentes en el sistema a
impedancias características.