Tubosistemas BIAXIAL de PAVCO WAVIN 5


Características 6
Resistencia ................................................................................................................ 6
Fortaleza .................................................................................................................... 8
Resistencia Química a la Corrosión .............................................................................. 10
Resistencia a los Efectos Ambientales ......................................................................... 10
Paredes Internas Lisas ............................................................................................... 11
Procesos contructivos .................................................................................................. 11
Referencias normativas ............................................................................................. 11

Portafolio 12
Tuberías BIAXIAL® de PAVCO ............................................................................................... 12
Accesorios BIAXIAL® de PAVCO ........................................................................................... 13

Diseño 15
Diseño ........................................................................................................................ 15
Diseño Hidráulico ....................................................................................................... 16
Cálculo del Golpe de Ariete .......................................................................................... 24
Diseño de Anclajes ...................................................................................................... 24
Diseño de Curvatura Longitudinal ................................................................................ 25

Cálculo de la Cimentación 28

3
CONTENIDO

Guía de Instalación 29
Recepción, transporte y almacenamiento .................................................................... 29
Manipulación ............................................................................................................. 30
Instalación ............................................................................................................... 30

Mantenimiento 32

Puesta en Servicio 33
Prueba Hidrostática ............................................................................................... 33
Prueba de Hermaticidad ........................................................................................... 33
Limpieza y Desinfección ........................................................................................... 34

Rotulado 34

Anexo 35

4
Tubosistemas BIAXIAL® de PAVCO WAVIN
para Agua Potable a Presión

Tecnología

El Policloruro de Vinilo, PVC es el plástico por excelencia,


básicamente inerte y virtualmente indestructible.

El desarrollo de la tecnología industrial ha permitido la manu-


factura en masa de este polímero para múltiples aplicaciones.

En la fabricación de Tubería para sistemas de agua potable,


tradicionalmente se ha trabajado con el PVC rígido, PVC-U, en
su estado polimérico normal, rígido sin plastificar brindando
características muy exitosas en el uso específico.

Detrás de este éxito y crecimiento, hay un continuo desarrollo


como el avance tecnológico de los procesos de fabricación,
mejoramiento de los sistemas de unión, mejoramiento de
calidad y ensayos, así como desarrollos en el conocimiento
fundamental de la estructura de la molécula de PVC.

Ese conocimiento de la estructura misma de la molécula en la


formación del producto, permite desarrollar sistemas y
procesos de fabricación de alta tecnología para orientar las
moléculas de PVC-U dentro del proceso mismo de fabricación
de los tubos y así obtener tubos de características superiores,
el Super PVC, PVC-O-BIAXIAL de PAVCO, la mejor tecnología
disponible hoy para uso en redes de agua potable.

La tecnología PVC-O-BIAXIAL de PAVCO es la tecnología por


medio de la cual se estiran en línea las moléculas del polímero,
obteniéndose su orientación, en el sentido circunferencial y
longitudinal, generando planos de orientación molecular, una
real estructura laminada en capas, incrementando significati-
vamente la resistencia mecánica y fortaleza del material.

5
Características

Gracias a la reorganización de las moléculas, la tubería de Resistencia a la Tensión


PVC-O-BIAXIAL mejora las características del PVC-U,
aumentando su resistencia y fortaleza. El gráfico mostrado líneas abajo muestra el incremento en
resistencia a la tensión de la tubería PVC-O-BIAXIAL
respecto al PVC-U y PE100.
Resistencia Para la tubería PVC-O-BIAXIAL su resistencia última a la
tensión es de 60 MPa y para el HDPE es 23 MPa. Se puede
La máxima tensión a la falla. Es la propiedad de las tubería observar que el PVC-O es 15% más resistente que el
de resistir la rotura debido a la presión interna en los PVC-U y 161% más resistente que el HDPE.
conductos de agua.

Al ser orientadas las moléculas en la tubería de PVC-O-BI-


Resistencia Hidrostática
AXIAL, éstas pueden soportar más presión. La fuerza El esfuerzo máximo de servicio en los materiales plásticos,
requerida para tensionar la estructura molecular orientada depende del tiempo. Es por esto necesario definir el
es mucho mayor, la presión es soportada por las fuerzas esfuerzo máximo de servicio en un tiempo de vida útil. Se
atómicas dentro de las cadenas moleculares. La fuerza ha escogido para los plásticos, 50 años. Este tiempo
requerida para estirar las moléculas ya estiradas, es puede ser mayor, dependiendo del coeficiente de diseño.
mucho mayor.
Para conocer el comportamiento del material en los 50
años se toman muestras de tubería y se hacen ensayos de
presión desde 10h hasta 9000h a 20°C. Estos datos se
grafican usando escala logarítmica y los 50 años son
obtenidos por análisis de regresión lineal múltiple de
acuerdo con la ISO 9080 e ISO 12162.

La tubería PVC-O-BIAXIAL está diseñada de acuerdo con


la NTP ISO 16422 donde:
RMR: Resistencia Mínima Requerida; es el valor requerido
del límite inferior de confianza de la resistencia hidrostáti-
ca prevista (σ LPL) a una temperatura de 20°C y un tiempo
(t) de 50 años.

70.0

60.0

52.0 PVC-O (Biaxial)

45.0
Esfuerzo (MPa)

PVC-U

30.0

23

15.0 HDPE (PE100)

0.0
0.0 75.0 150.0 225.0 300.0

Deformación (%)

6
C: Coeficiente de diseño será C=2.0 La relación con RMR, Ecuación ISO: PN=20 RMR/(S-
DR-1)C, donde SDR=DN/e, “e” es espesor mínimo de
σ: Esfuerzo de diseño. Es la tensión estimada en la pared pared y DN es el diámetro nominal exterior.
de la tubería en la dirección circunferencial generada por la
presión hidrostática que puede ser aplicada en forma Los conceptos descritos líneas arriba se aplican de
continua con un alto grado de certeza de que la tubería no manera similar a otros materiales; la comparación de los
va a fallar. σ=RMR/C valores de los diferentes materiales, permite observar que
el PVC-O tiene ventajas estructurales, por lo tanto el
P: Presión de Trabajo . Presión máxima que puede soportar PVC-O (tubería BIAXIALPAVCO) ofrece mayor seguridad en
un sistema de tubería en uso contínuo sin sobrepresión. los sistemas presurizados.

Descripción PVC U PVC-O BIAXIAL PE 100

RMR 25 MPa 45 MPa 10 MPa


C 2.5 2.0 1.25
σ 10 MPa 22.5 MPa 8 MPa
P 10 bar (SDR 21) 10 bar (SDR 45) 10 bar (SDR 17)

*Nota: Para otras presiones nominales consulten al departamento técnico.

Resistencia Hidrostática a Largo Plazo


75
68

60 Línea de Regresión PVC-O


Esfuerzo (MPa)

RMR PVC-O
45
42 Tiempo Log (horas)
Línea de Regresión PVC-U
30
RMR PVC-U
25
Línea de Regresión HDPE
15
RMR HDPE (PE100)
10

0.0
0.0 10 10 000 100 000 50 años

Tiempo Log (Horas)

La vida útil es de 50 años*


*Esta información no es una Garantía de Producto dado que PAVCO no ejerce control
sobre todos los aspectos que se presentan en la instalación y que afectan directamente el
desempeño y la vida útil del producto.

7
Fortaleza

Los planos moleculares biorientados que se generan en Resistencia al Impacto


el proceso de biorientación aumenta considerablemente
su fortaleza. Estos planos responden a las fallas en forma Cualquier tubería en obra puede fisurarse por el maltrato
independiente, sin transmitir la falla a los planos siguien- propio en obra. Para una condición de fisura (ver foto
tes. Esta fortaleza se ve reflejada en la resistencia a la adjunta) similar para tubería PVC-U y PVC-O, ésta última al
falla frágil. Es la resistencia al daño externo por impacto recibir un impacto resistirá de manera mucho más
y a la propagación lenta de fracturas. Es respuesta dúctil favorable que un tubo de PVC-U.
en el evento de fallas.
Resistencia a la Fractura Frágil Secuencia
Resistencia a la Falla Frágil (Fractura)
La estructura laminada, por capas, producto de la
biorientación ofrece
excelente resistencia a la falla frágil.

En la secuencia de fotos puede verse, como la tubería


PVC-O-BIAXIAL va inflándose por efecto de la sobre
presión interna, hasta producirse una falla dúctil. La
tubería es capaz de absorber sobre presiones causadas
por lo efectos del golpe de ariete.

ENERGÍA AL IMPACTO
PVC-U PVC-O
Ø Kg*m Kg*m
90 0.96 10
110 1.60 12.60
160 3.20 16.00
200 4.00 20.00
250 5.00 25.00
315 6.40 25.00
355 6.40 25.00
400 6.40 25.00

RESISTENCIA AL IMPACTO

PVC - U

PVC-O Biaxial

8
Propagación de Facturas
BIAXIAL® de PAVCO WAVIN
La estructura laminada de la tubería PVC-O-BIAXIAL evita
la transmisión de fisuras a través de la pared de la tubería.
PAVCO ha realizado el ensayo de comprobación, simulan-
do esta condición con fisuras en ambas tuberías PVC-O y
PVC-U, sometiéndolas a tensión, de tal forma que se abre
el anillo y se puede comparar el comportamiento de la
fisura.
PVC - U

El diseño de producto y el desempeño en un sistema de


tubería para transporte de fluídos, como el caso de los La tubería PVC-O-BIAXIAL mejora considerablemente
sistemas de conducción de agua presurizada, depende del estas dos características, ofreciendo ventajas y beneficios
balance de estos dos criterios, Resistencia y Fortaleza. a los sistemas, como son:

Característica Beneficio

Mayor resistencia Posee mayor resistencia a la presión hidrostática y a la tensión, conser-


vando alta rigidez y mayor durabilidad. Tubería más liviana para la
misma presión de servicio.

Mejora la resistencia al impacto a bajas temperaturas, mayor resisten-


cia a la falla frágil, mayor resistencia a la propagación lenta de fisuras.
Mayor fortaleza
Los golpes causados durante la manipulación no conducen a daños en
el corto o mediano plazo. Respuesta dúctil. Es tolerante al maltrato.

Al realizar la comparación entre la tubería PVC-O-BIAXIAL y PVC-U con


Menor diámetro el mismo diámetro nominal (DN) y presión nominal (PN), obtenemos
mayor capacidad hidráulica para el PVC-O BIAXIAL generando menos
pérdida de carga.

Mayor grado de curvatura de la tubería. Menos cantidad de accesorios


Mayor flexibilidad curvos. Recuperación bondadosa de ovalidad. Ahorro en proceso de
instalación.

Proceso en línea La orientación molecular en los ejes longitudinal y circunferencial en el


mismo proceso, hace que garantice la duración y calidad del producto.

Campana con anillo El refuerzo de polipropileno (PP) elimina riesgo de desplazamiento del
anillo elastómerico durante el ensamble. Otorga confiabilidad en la
elastomérico instalado
hermeticidad al emplear anillo normado.
en fábrica

Además, la tubería PVC-O-BIAXIAL ofrece los beneficios propios de la tubería para conducción de aguas presurizadas PVC-U tradicionales.

9
Resistencia Química a la Corrosión

La tubería de PVC es inmune a casi todos los tipos de [PFA] = ft x [PN]


corrosión, químicas y electroquímicas, que pueden encon- Y
trarse en un sistema de tubería enterrada. Efectos galváni-
cos y electroquímicos no existen en sistemas con tubería
de PVC, ya que el PVC no es conductor de la electricidad. 1

La tubería de PVC no sufren daños por aguas o suelos


agresivos, en consecuencia no requieren protecciones
catódicas, recubrimientos especiales o pinturas. Esto 0,8
significa ahorro en costos iniciales de los sistemas y
garantía de larga vida de éstos, durabilidad.
0,6

Resistencia a los Efectos


Ambientales 0,4

Temperatura 10

Leyenda
20 30 40 50 X

La temperatura de operación tiene significación importante


X es la temperatura en °C
en el comportamiento de la tubería de PVC, teniendo en Y es el factor de reducción en ft
cuenta que este es un material termoplástico. La tubería Gráfico - Coeficiente de reducción ft en función de la temperatura de servicio
está diseñada para operar a 20°C, como temperatura
promedio.
Clima
Si la temperatura decrece, su rigidez y resistencia a la Largas exposiciones a la radiación ultravioleta, UV, prove-
tensión incrementa, por lo que su capacidad de presión y nientes de la luz solar, pueden causar deterioro en la
habilidad de soportar cargas aumenta. superficie de la tubería de PVC. Este término es llamado
Degradación Ultravioleta. El deterioro causa disminución en
Pero si la temperatura aumenta, disminuye su rigidez y la resistencia al impacto y a la presión. La tubería de PVC
resistencia a la tensión, lo que significa que debe tenerse no son recomendadas para aplicaciones donde van a estar
mayor cuidado en la instalación y que su capacidad de expuestas en forma permanente a la luz solar, a menos
resistencia a la presión interna disminuye y debe tenerse que se provea alguna protección física como pintura o
en cuenta anticipadamente en el diseño. Ver cuadro a recubrimientos.
continuación.
Abrasión
Factores para Correción de Presión de Alta resistencia a la abrasión gracias a la resiliencia del
Trabajo por Aumento de Temperatura compuesto de PVC. Supera a todos los materiales conven-
cionales.
La presión de funcionamiento admisible, PFA, para
temperaturas hasta 25°C es igual a la presión nominal, PN. Formación de Incrustaciones
Los elementos incrustantes solubles, tales como carbonato
Para determinar la presión de funcionamiento admisible, de calcio, no se incrusten en las paredes lisas de la tubería
PFA, para temperaturas entre 25°C y 45°C, se debe de PVC.
aplicar un factor de reducción suplementario, ft, a la
presión nominal, PN, como se indica en el gráfico: Ataque Biológico
Es la degradación o deterioro causada por la acción de
micro y macroorganismos. El PVC no es atacado, ya que no
sirve como nutriente a estos organismos. Esto significa que
no se requiere especiales consideraciones de instalación
para prevenir ataque biológico en sistemas de Tubería de
PVC.

10
Paredes Internas Lisas Procesos Constructivos
En la instalación de tubería, se deben tomar en cuenta
diversos factores y con la tubería Biaxial se optimizan todos
Ofrecen baja resistencia al flujo, lo que permite mayores los procesos. Algunos de los aspectos son:
capacidades hidráulicas. Dificultan la formación de
biopelículas y facilitan su desprendimiento en las opera- -Facilidad de transporte y manipulación
ciones de limpieza. -Facilidad de instalación
-Flexibilidad
-No requiere equipos pesados
n = 0.009 (manning)
-Capacidad de acomodarse en curvaturas moderadas sin
Ks = 1.5 x 10-6m Rugosidad Absoluta
afectación estructural de la tubería a las condiciones de
C = 150 (Hazen & Williams)
terreno

La tubería PVC-O-Biaxial es la Mejor Opción


Para Conducciones de Aguas Presurizadas
con Tubosistemas Dúctiles, Flexibles, más
Resistentes a la Propagación de Fisuras y
Livianos.

Referencias Normativas
• La tubería PVC-O-BIAXIAL es fabricada de acuerdo con la
Norma Técnica Peruana (NTP) ISO 16422: 2020, tubos y
uniones de poli cloruro de vinilo no plastificado orientado
(PVC-O) para conducción de agua a presión.
• Los acoples de tubería son de unión flexible (UF)
empleando anillos elastoméricos que cumplen la Norma
NTP ISO 4633
• Recomendaciones de instalación según NTP ISO TR
4191 2016
• Resistencia a la tracción Norma ISO 6259-2
• Resistencia a la presión hidrostática Norma ISO NTP
1167
• Resistencia a impacto externo a 0°C Norma ISO 3127
• Rigidez Anular Norma ISO 9969
• Determinación de la resistencia hidrostática a largo plazo
Norma ISO 9080

11
Portafolio Tubería BIAXIAL de PAVCO WAVIN

La tubería se fabrica campana – espigo, con el anillo


instalado en fábrica, con un refuerzo de Polipropileno que
garantiza un ensamble adecuado y no permite que el anillo
se corra o se muerda.

CARACTERISTICAS TÉCNICAS DE LA TUBERÍA DE PVC-O (Biorientado)


PARA LA CONDUCCIÓN DE AGUA POTABLE A PRESIÓN
Tubos para Agua Potable a Presión - Unión Flexible (UF) NTP ISO 16422: 2020

Diámetro Diámetro PN (8bar) PN 10 (10 bar) PN 16 (16 bar) Longitud


Nominal(DN) Exterior(DE) Diámetro Diámetro Diámetro (mm)
mm mm Interior (mm) Interior (mm) Interior (mm) Total Útil
Coeficiente de Diseño C= 2.0

90 90 85.60 84.20 6.00 5.904


110 110 105.20 105.00 *102.20 6.00 5.896
160 160 153.00 152.80 148.80 6.00 5.881
200 200 191.20 191.00 186.00 6.00 5.871
250 250 239.00 238.80 232.60 6.00 5.857
315 315 301.20 301.00 293.20 6.00 5.840
355 355 339.40 339.20 330.40 6.00 5.831
400 400 382.40 382.20 6.00 5.822
Para todos los diámetros en PN 16 el esfuerzo de diseño requerido es de 23 Mpa, según NTP 16422: 2012(SDR 29)
Para todos los diámetros en PN 10 el esfuerzo de diseño requerido es de 23 Mpa, según NTP 16422: 2012(SDR 45.8)
Para todos los diámetros en PN 8 el esfuerzo de diseño requerido es de 18 Mpa, según NTP 16422: 2012(SDR 45.8)
Para todos los diámetros en 90 mm 10 y PN 8 el esfuerzo de diseño requerido es de 16 Mpa (SDR 33, SDR 41respectivamente)
*Consultar con el representante de ventas
*NOTA: El RDE de las tuberias biaxial no corresponde al rde del pvc-u convencional

12
Accesorios PVC-U para Tubería BIAXIAL

Tee Inyectada con acoples


A
Tee Inyectada Totalmente
(PN 10) C/Reducción (PN 10)
L
L

Diámetro L A Diámetro L A
Nominal mm mm Nominal mm mm
90 x 90 330 228 110 x 90 550 180
110 x 110 370 260.5 160 x 90 710 210
160 x 160 462 337.5 160 x 110 710 240
200 x 200 545 403.5 200 x 90 760 220
250 x 250 1012 658.5 200 x 110 760 270
315 x 315 1194 788 200 x 160 760 330
250 x 110 800 200
250 x 160 800 350
250 x 200 850 450
315 x 160 900 380
315 x 200 900 470
315 x 250 900 520

A
Tee Inyectada Totalmente
C/Reducción (PN 10)
L

Reducción campana UF X Espigo


Diámetro
Nominal
L
mm
A
mm
A PN 10(presión 145 psi)
L
90 x 63 330 217
110 x 63
110 x 90
370
370
241.5
252.5
e Diámetro
Nominal
L
mm
A
mm
160 x 63 462 301.5 110 x 90 310 180
160 x 90 462 312.5 160 x 110 380 230
160 x 110 462 320.5 200 x 160 400 230
200 x 90 545 362.5 250 x 160 470 270
200 x 110 545 370.5 250 x 200 470 290
200 x 160 545 396.5 315 x 200 480 290
315 x 250 480 375

A A
Tee Inyectada acoples Tapón Inyectado con
(PN 10) Acople (PN 10)
L L

Diámetro L A Diámetro L A
Nominal mm mm Nominal mm mm
90 180 530 90 225 155
110 200 550 110 250 180
160 420 710 160 300 21
200 460 760 200 350 240
250 480 810 250 390 280
315 500 830 315 410 330

*Todos los accesorios cumplen con la NTP ISO 1452-3

13
Z

A
Unión Corrediza PN 10 R
Curva de Gran Radio 90º
(Presión 145psi) Z 90°
L L

Diámetro L A Diámetro L A Radio de Curvatura


Nominal mm mm Nominal mm mm (mm)
90 320 120 90 168 298 315
110 355 144 110 166 325 385
160 410 202 160 203 435 560
200 460 238 200 234 524 700
250 545 305 250 361 723 875
315 635 382 315 363 819 1103
355 670 425 355 459 973 1203
400 695 475 400 528 1107 1400

Z
Z

Z
R 22.5° Curva de Gran Radio 22.5º Z Curva de Gran Radio 45º
L L

Diámetro L A Radio de Curvatura Diámetro L A Radio de Curvatura


Nominal mm mm (mm) Nominal mm mm (mm)
90 168 298 315 90 168 298 315
110 166 325 385 110 166 325 385
160 203 435 560 160 203 435 560
200 234 524 700 200 234 524 700
250 361 723 875 250 361 723 875
315 363 819 1103 315 363 819 1103
355 459 973 1203 355 459 973 1203
400 528 1107 1400 400 528 1107 1400

RENDIMIENTO LUBRICANTE PAVCO


Longitud de Entrada Rendimiento
Diámetro Nominal
de los Espigos por galón

mm mm
90 105 400
110 139 378
160 161 253
200 180 241
250 203 144
315 211 100
355 220 58
400 232 38

Características
• Procedencia vegetal
• Inocuo para los anillos UF
• No irrita ojos ni piel
• Presentación de 01 galón

14
Uniones Resistentes al Efecto Axial

Las uniones resistentes al efecto axial se destinan a la


unión de tubos de PVC-U con diámetros que se ajustan a Presión de trabajo 10 bar
NTP ISO 1452 O NTP ISO 16422 cuando se esperan Material PVC-U
fuerzas longitudionales sobre las uniones. Las uniones Norma ISO 1452
resistentes al efecto axial con juntas de anillo de sello
elastomerico y un dispositivo de bloqueo.

Unión Resistente al Efecto Axial Tipo 3 Unión Resistente al Efecto Axial Tipo 5

0 (mm) 63 110 160 200 250

Diseño
El estudio sobre el comportamiento hidráulico y la determi-
nación de coeficiente de rugosidad en tubería para agua
presurizada, forma parte de uno diferentes temas de inves-
0 (mm) 315 355 400 tigación que desarrolla el centro de investigaciones en
Acueductos y Alcantarillados (CIACUA) de la universidad de
los Andes a través de la “Cátedra PAVCO” período 2001 -
Unión Resistente al Efecto Axial Tipo 4 2002, proyecto de investigación patrocinado por PAVCO
desde hace 13 años.

El estudio consistió en la modelación de las pérdidas por


fricción generadas por diferentes regímenes de flujo a
partir de la disposición de un montaje realizado en el
laboratorio de hidráulica de la Universidad de los Andes con
la tubería BIAXIAL PAVCO y la valoración de la información
observada es valorada por un modelo matemático.

0 (mm) 63 110 160

15
A partir del montaje del modelo físico a esacala real para Se encontró que para que se cumpla lo anterior la magni-
simular las pérdidas de energía generadas bajo diferentes tud del caudal debe ser muy alta, correspondientes a
caudales, se obtienen datos experimentales de la presión velocidades que superan ampliamente las velocidade
aplicando las ecuacionesd de Bernoulli para las pérdidas máximas permitidas por las empresas operadoras del
por fricción, de Darcy-Weisbach para la valoración de los servicio de agua potable, por lo que se pueda asegurar que
resultados, el entendimiento del diagrama de Moody y de la tubería BIAXIAL siempre van a estar trabajando bajo flujo
los diferentes tipos de flujes presentes en las tuberías con hidráulicamente liso y por lo tanto la rugosidad del material
flujo de presión (flujos laminar, turbulento hidráulicamente no va afectar las pérdidas de energía que se generen. La
liso, hidráulicamente rugoso y flujo trancisional ). principal conlusión del ensayo permite asegurar que las
pérdidas de energía que se generen. La principal
Apartir de los resultados se obtienen curvas experimental- conclusión del ensayo permite asegurar que las pérdidas
es que son graficadas en el digráma de Moody en donde el de energía que se van a producir en una tubería BIAXIAL
principal objetivo es analizar el desempeño de la tubería son muy pequeñas en comparación con otros materiales y
BIAXIAL bajo diferentes condiciones de caudal y establecer que además su rugosidad (Ks) no va a afectar el régimen
establecer la rugosidad absoluta del material de la tubería. de flujo.

Resultados
Luego de analizar el ensayo de laboratorio de logró
establecer el caudal necesario para que la rugosidad
teórica de la tubería BIAXIAL (0.0015) empiece a efectar
ñas pérdidas pro fricción que se generan, es decir el caudal
necesario para que la subcapa laminar viscosa disminuya
hasta que la rugosidad teórica supere el límite de 0.305 ,
donde corresponde al espesor de la subcapa laminar
Comportamiento del límite de los flujos en los datos experimentales
viscosa.

Diseño Hidráulico

Metodología según la Fórmula William & Hazen Donde:


Hf: Pérdida de presión en m.a.c/1mt
Fórmula:
Q: Flujo m3/s
D: Diámetro interior en m
10,64 x Q1,852
Hf = C: Factor de fricción constante = 150
C1.852 x D4.871
Nota:
Q1.852
Hf = 0.000927 Los parámetros de diseño de un proyecto y obra son
D4.871 responsabilidad exclusiva del diseñador.

16
Metodología Darcy-Weisbach Donde:
Para diseñar de acuerdo con la metodología de Darcy-Weisbach se utilizan
Hf: Pérdida de cabeza a lo largo del tramo (m)
las siguientes ecuaciones:
f: Factor de fricción de Darcy (Adimensional)
Ecuación de Darcy-Weisbach l: Longitud del tramo de tubería (m)
d: Diámetro interior de la tubería (m)
l V2 Velocidad media de flujo (m/s)
Hf = f v:
d 2g V.d g.: Aceleración de la gravedad (m/s2)
Re =
ν Ks: Rugosidad absoluta de la tubería (m).
Ecuación de Colebrook-White Para PVC = 1.5*10-6m
Re: Número de Reynolds = V d/v (Adimensional)
1 Ks 2.51
= -2log10 + ν: Viscocidad cinemática del fluido (m2/s)
f 3.7d Re f

Viscocidad Cinemática del Agua


Tomado de Tuberías, tomo 1 J.M. Mayol

Temperatura Viscosidad Cinemática


o
C cm2/sg
0 0,0176
10 0,0131
12 0,0124
20 0,0100
30 0,0080
40 0,0066
60 0,0048
80 0,0036
100 0,0030

17
ECUACIÓN HAZEN WILLIAMS Chw 150 Presión Nominal 8 BAR
Diámetro Nominal mm 90 110 160 200 250 315 355 400
Diámetro Interior mm 85.6 105.2 153 191.2 239 301.2 339.4 382.4
CAUDAL Vel. hf Vel. hf Vel. hf Vel. hf Vel. hf Vel. hf Vel. hf Vel. hf
l/s m/s m m/s m m/s m m/s m m/s m m/s m m/s m m/s m
1.00 0.174 0.0004
2.00 0.348 0.0016
3.00 0.521 0.0034
4.00 0.695 0.0057
5.00 0.869 0.0087 0.575 0.0032
6.00 1.043 0.0121 0.690 0.0044
7.00 1.216 0.0162 0.805 0.0059
8.00 1.390 0.0207 0.920 0.0076
9.00 1.564 0.0257 1.035 0.0094
10.00 1.738 0.0313 1.150 0.0115 0.544 0.0018
11.00 1.911 0.0373 1.266 0.0137 0.598 0.0022
12.00 2.085 0.0438 1.381 0.0161 0.653 0.0026
13.00 2.259 0.0509 1.496 0.0186 0.707 0.0030
14.00 2.433 0.0583 1.611 0.0214 0.761 0.0034
15.00 2.606 0.0663 1.726 0.0243 0.816 0.0039 0.522 0.0013
20.00 3.475 0.1129 2.301 0.0414 1.088 0.0067 0.697 0.0023
25.00 2.876 0.0625 1.360 0.0101 0.871 0.0034 0.557 0.0011
30.00 3.451 0.0876 1.632 0.0141 1.045 0.0048 0.669 0.0016
35.00 4.027 0.1166 1.904 0.0188 1.219 0.0064 0.780 0.0021
40.00 2.176 0.0241 1.393 0.0081 0.892 0.0027 0.561 0.0009
45.00 2.448 0.0300 1.567 0.0101 1.003 0.0034 0.632 0.0011
50.00 2.720 0.0364 1.741 0.0123 1.115 0.0041 0.702 0.0013 0.553 0.0008
55.00 2.992 0.0434 1.916 0.0147 1.226 0.0049 0.772 0.0016 0.608 0.0009
60.00 3.263 0.0510 2.090 0.0172 1.337 0.0058 0.842 0.0019 0.663 0.0011
65.00 3.535 0.0592 2.264 0.0200 1.449 0.0067 0.912 0.0022 0.718 0.0012 0.566 0.0007
70.00 3.807 0.0679 2.438 0.0229 1.560 0.0077 0.982 0.0025 0.774 0.0014 0.609 0.0008
75.00 4.079 0.0772 2.612 0.0261 1.672 0.0088 1.053 0.0028 0.829 0.0016 0.653 0.0009
80.00 4.351 0.0870 2.786 0.0294 1.783 0.0099 1.123 0.0032 0.884 0.0018 0.697 0.0010
85.00 4.623 0.0973 2.960 0.0329 1.895 0.0111 1.193 0.0036 0.940 0.0020 0.740 0.0011
90.00 4.895 0.1081 3.135 0.0365 2.006 0.0123 1.263 0.0040 0.995 0.0022 0.784 0.0012
95.00 5.167 0.1195 3.309 0.0404 2.118 0.0136 1.333 0.0044 1.050 0.0025 0.827 0.0014
100.00 3.483 0.0444 2.229 0.0150 1.403 0.0049 1.105 0.0027 0.871 0.0015
110.00 3.831 0.0530 2.452 0.0179 1.544 0.0058 1.216 0.0032 0.958 0.0018
120.00 4.179 0.0622 2.675 0.0210 1.684 0.0068 1.326 0.0038 1.045 0.0021
130.00 4.528 0.0722 2.898 0.0243 1.824 0.0079 1.437 0.0044 1.132 0.0025
140.00 4.876 0.0828 3.121 0.0279 1.965 0.0091 1.547 0.0051 1.219 0.0028
150.00 5.224 0.0941 3.344 0.0317 2.105 0.0103 1.658 0.0057 1.306 0.0032
160.00 5.573 0.1060 3.566 0.0358 2.246 0.0116 1.769 0.0065 1.393 0.0036
170.00 5.921 0.1186 3.789 0.0400 2.386 0.0130 1.879 0.0072 1.480 0.0041
180.00 4.012 0.0445 2.526 0.0144 1.990 0.0081 1.567 0.0045
190.00 4.235 0.0492 2.667 0.0159 2.100 0.0089 1.654 0.0050
200.00 4.458 0.0540 2.807 0.0175 2.211 0.0098 1.741 0.0055
210.00 4.681 0.0592 2.947 0.0192 2.321 0.0107 1.828 0.0060
220.00 4.904 0.0645 3.088 0.0209 2.432 0.0117 1.916 0.0065
230.00 5.127 0.0700 3.228 0.0227 2.542 0.0127 2.003 0.0071
240.00 5.350 0.0758 3.368 0.0246 2.653 0.0137 2.090 0.0077
250.00 5.573 0.0817 3.509 0.0265 2.763 0.0148 2.177 0.0083
260.00 5.795 0.0879 3.649 0.0285 2.874 0.0159 2.264 0.0089
270.00 6.018 0.0942 3.789 0.0305 2.984 0.0171 2.351 0.0096
280.00 6.241 0.1008 3.930 0.0327 3.095 0.0183 2.438 0.0102
290.00 6.464 0.1076 4.070 0.0349 3.205 0.0195 2.525 0.0109
300.00 6.687 0.1145 4.210 0.0371 3.316 0.0208 2.612 0.0116
320.00 4.491 0.0418 3.537 0.0234 2.786 0.0131
340.00 4.772 0.0468 3.758 0.0262 2.960 0.0146
360.00 5.052 0.0520 3.979 0.0291 3.135 0.0163
380.00 5.333 0.0575 4.200 0.0321 3.309 0.0180
400.00 5.614 0.0632 4.421 0.0354 3.483 0.0198
420.00 5.895 0.0692 4.642 0.0387 3.657 0.0216
440.00 6.175 0.0754 4.863 0.0422 3.831 0.0236
460.00 6.456 0.0819 5.084 0.0458 4.005 0.0256
480.00 6.737 0.0886 5.306 0.0496 4.179 0.0277
500.00 7.017 0.0956 5.527 0.0534 4.354 0.0299

hf= Pérdida de carga en metro de columna de agua por cada metro de tubería
V = Velocidad en metros por segundo (m/s)

18
ECUACIÓN HAZEN WILLIAMS Chw 150 Presión Nominal 10 BAR
Diámetro Nominal mm 90 110 160 200 250 315 355 400
Diámetro Interior mm 84.2 105 152.8 191 238.8 301 339.2 382.2
CAUDAL Vel. hf Vel. hf Vel. hf Vel. hf Vel. hf Vel. hf Vel. hf Vel. hf
l/s m/s m m/s m m/s m m/s m m/s m m/s m m/s m m/s m
1.00 0.180 0.0005
2.00 0.359 0.0017
3.00 0.539 0.0036
4.00 0.718 0.0062
5.00 0.898 0.0094 0.577 0.0032
6.00 1.078 0.0132 0.693 0.0045
7.00 1.257 0.0175 0.808 0.0060
8.00 1.437 0.0224 0.924 0.0077
9.00 1.616 0.0279 1.039 0.0095
10.00 1.796 0.0339 1.155 0.0116 0.545 0.0019
11.00 1.976 0.0404 1.270 0.0138 0.600 0.0022
12.00 2.155 0.0475 1.386 0.0162 0.654 0.0026
13.00 2.335 0.0551 1.501 0.0188 0.709 0.0030
14.00 2.514 0.0632 1.617 0.0216 0.763 0.0035
15.00 2.694 0.0718 1.732 0.0245 0.818 0.0039 0.524 0.0013
20.00 3.592 0.1224 2.310 0.0418 1.091 0.0067 0.698 0.0023
25.00 2.887 0.0631 1.363 0.0102 0.873 0.0034 0.558 0.0012
30.00 3.465 0.0885 1.636 0.0142 1.047 0.0048 0.670 0.0016
35.00 4.042 0.1177 1.909 0.0189 1.222 0.0064 0.781 0.0022
40.00 2.181 0.0242 1.396 0.0082 0.893 0.0028 0.562 0.0009
45.00 2.454 0.0302 1.571 0.0102 1.005 0.0034 0.632 0.0011
50.00 2.727 0.0366 1.745 0.0124 1.116 0.0042 0.703 0.0013 0.553 0.0008
55.00 2.999 0.0437 1.920 0.0147 1.228 0.0050 0.773 0.0016 0.609 0.0009
60.00 3.272 0.0514 2.094 0.0173 1.340 0.0058 0.843 0.0019 0.664 0.0011
65.00 3.545 0.0596 2.269 0.0201 1.451 0.0068 0.913 0.0022 0.719 0.0012 0.567 0.0007
70.00 3.817 0.0683 2.443 0.0231 1.563 0.0078 0.984 0.0025 0.775 0.0014 0.610 0.0008
75.00 4.090 0.0777 2.618 0.0262 1.675 0.0088 1.054 0.0029 0.830 0.0016 0.654 0.0009
80.00 4.363 0.0875 2.792 0.0295 1.786 0.0099 1.124 0.0032 0.885 0.0018 0.697 0.0010
85.00 4.635 0.0979 2.967 0.0330 1.898 0.0111 1.195 0.0036 0.941 0.0020 0.741 0.0011
90.00 4.908 0.1088 3.141 0.0367 2.009 0.0124 1.265 0.0040 0.996 0.0022 0.784 0.0013
95.00 5.181 0.1203 3.316 0.0406 2.121 0.0137 1.335 0.0044 1.051 0.0025 0.828 0.0014
100.00 3.490 0.0446 2.233 0.0150 1.405 0.0049 1.107 0.0027 0.872 0.0015
110.00 3.839 0.0532 2.456 0.0179 1.546 0.0058 1.217 0.0032 0.959 0.0018
120.00 4.188 0.0625 2.679 0.0211 1.686 0.0068 1.328 0.0038 1.046 0.0021
130.00 4.537 0.0725 2.903 0.0244 1.827 0.0079 1.439 0.0044 1.133 0.0025
140.00 4.886 0.0832 3.126 0.0280 1.967 0.0091 1.549 0.0051 1.220 0.0028
150.00 5.235 0.0945 3.349 0.0319 2.108 0.0103 1.660 0.0058 1.307 0.0032
160.00 5.584 0.1065 3.572 0.0359 2.249 0.0116 1.771 0.0065 1.395 0.0036
170.00 5.933 0.1192 3.796 0.0402 2.389 0.0130 1.881 0.0073 1.482 0.0041
180.00 4.019 0.0447 2.530 0.0145 1.992 0.0081 1.569 0.0045
190.00 4.242 0.0494 2.670 0.0160 2.103 0.0089 1.656 0.0050
200.00 4.466 0.0543 2.811 0.0176 2.213 0.0098 1.743 0.0055
210.00 4.689 0.0594 2.951 0.0192 2.324 0.0108 1.830 0.0060
220.00 4.912 0.0647 3.092 0.0210 2.435 0.0117 1.918 0.0066
230.00 5.135 0.0703 3.232 0.0228 2.545 0.0127 2.005 0.0071
240.00 5.359 0.0761 3.373 0.0246 2.656 0.0138 2.092 0.0077
250.00 5.582 0.0820 3.513 0.0266 2.767 0.0148 2.179 0.0083
260.00 5.805 0.0882 3.654 0.0286 2.877 0.0160 2.266 0.0089
270.00 6.028 0.0946 3.794 0.0306 2.988 0.0171 2.353 0.0096
280.00 6.252 0.1012 3.935 0.0328 3.099 0.0183 2.441 0.0102
290.00 6.475 0.1080 4.075 0.0350 3.209 0.0195 2.528 0.0109
300.00 6.698 0.1150 4.216 0.0372 3.320 0.0208 2.615 0.0116
320.00 4.497 0.0420 3.541 0.0235 2.789 0.0131
340.00 4.778 0.0470 3.763 0.0262 2.964 0.0147
360.00 5.059 0.0522 3.984 0.0292 3.138 0.0163
380.00 5.340 0.0577 4.205 0.0322 3.312 0.0180
400.00 5.321 0.0634 4.426 0.0355 3.486 0.0198
420.00 5.902 0.0694 4.648 0.0388 3.661 0.0217
440.00 6.183 0.0754
0.0757 4.869 0.0423 3.835 0.0237
460.00 6.465 0.0822 5.090 0.0459 4.009 0.0257
480.00 6.746 0.0889 5.312 0.0497 4.184 0.0278
500.00 7.027 0.0959 5.533 0.0536 4.358 0.0300

hf= Pérdida de carga en metro de columna de agua por cada metro de tubería
V = Velocidad en metros por segundo (m/s)

19
ECUACIÓN HAZEN WILLIAMS Chw 150 Presión Nominal 16 BAR
Diámetro Nominal mm 90 110 160 200 250 315 355 400
Diámetro Interior mm 81.2 102.2 148.8 186 232.6 293.2 330.4 372.4
CAUDAL Vel. hf Vel. hf Vel. hf Vel. hf Vel. hf Vel. hf Vel. hf Vel. hf
l/s m/s m m/s m m/s m m/s m m/s m m/s m m/s m m/s m
1.00 0.193 0.0006
2.00 0.386 0.0021
3.00 0.579 0.0044
4.00 0.772 0.0074
5.00 0.966 0.0112 0.610 0.0037
6.00 1.159 0.0157 0.731 0.0051
7.00 1.352 0.0209 0.853 0.0068
8.00 1.545 0.0268 0.975 0.0087
9.00 1.738 0.0333 1.097 0.0109
10.00 1.931 0.0404 1.219 0.0132 0.575 0.0021
11.00 2.124 0.0483 1.341 0.0157 0.633 0.0025
12.00 2.317 0.0567 1.463 0.0185 0.690 0.0030
13.00 2.510 0.0658 1.585 0.0214 0.748 0.0034
14.00 2.703 0.0754 1.707 0.0246 0.805 0.0039
15.00 2.897 0.0857 1.829 0.0280 0.863 0.0045 0.552 0.0015
20.00 3.862 0.1460 2.438 0.0476 1.150 0.0076 0.736 0.0026
25.00 3.048 0.0720 1.438 0.0116 0.920 0.0039 0.588 0.0013
30.00 3.657 0.1009 1.725 0.0162 1.104 0.0055 0.706 0.0018
35.00 4.267 0.1343 2.013 0.0215 1.288 0.0073 0.824 0.0024
40.00 2.300 0.0276 1.472 0.0093 0.941 0.0031 0.592 0.0010
45.00 2.588 0.0343 1.656 0.0116 1.059 0.0039 0.666 0.0013
50.00 2.875 0.0417 1.840 0.0141 1.177 0.0047 0.741 0.0015 0.583
55.00 3.163 0.0498 2.024 0.0168 1.294 0.0056 0.815 0.0018 0.641 0.0010
60.00 3.450 0.0585 2.208 0.0197 1.412 0.0066 0.889 0.0021 0.700 0.0012
65.00 3.738 0.0678 2.392 0.0229 1.530 0.0077 0.963 0.0025 0.758 0.0014 0.597 0.0008
70.00 4.025 0.0778 2.576 0.0262 1.647 0.0088 1.037 0.0029 0.816 0.0016 0.643 0.0009
75.00 4.313 0.0884 2.760 0.0298 1.765 0.0100 1.111 0.0032 0.875 0.0018 0.689 0.0010
80.00 4.600 0.0996 2.944 0.0336 1.883 0.0113 1.185 0.0037 0.933 0.0020 0.734 0.0011
85.00 4.888 0.0114 3.128 0.0376 2.000 0.0126 1.259 0.0041 0.991 0.0023 0.780 0.0013
90.00 5.175 0.1238 3.312 0.0418 2.118 0.0141 1.333 0.0046 1.050 0.0025 0.826 0.0014
95.00 5.463 0.1369 3.496 0.0462 2.236 0.0155 1.407 0.0050 1.108 0.0028 0.872 0.0016
100.00 3.680 0.0508 2.353 0.0171 1.481 0.0055 1.166 0.0031 0.918 0.0017
110.00 4.048 0.0606 2.589 0.0204 1.629 0.0066 1.283 0.0037 1.010 0.0021
120.00 4.416 0.0712 2.824 0.0240 1.777 0.0078 1.400 0.0043 1.102 0.0024
130.00 4.784 0.0825 3.059 0.0278 1.925 0.0090 1.516 0.0050 1.194 0.0028
140.00 5.152 0.0947 3.295 0.0319 2.074 0.0103 1.633 0.0058 1.285 0.0032
150.00 5.520 0.1076 3.530 0.0362 2.222 0.0117 1.750 0.0066 1.377 0.0037
160.00 5.888 0.1212 3.765 0.0408 2.370 0.0132 1.866 0.0074 1.469 0.0041
170.00 6.257 0.1356 4.001 0.0457 2.518 0.0148 1.983 0.0083 1.561 0.0046
180.00 4.236 0.0508 2.666 0.0164 2.099 0.0092 1.653 0.0051
190.00 4.471 0.0561 2.814 0.0182 2.216 0.0102 1.744 0.0057
200.00 4.707 0.0617 2.962 0.0200 2.333 0.0112 1.836 0.0062
210.00 4.942 0.0675 3.110 0.0219 2.449 0.0122 1.928 0.0068
220.00 5.177 0.0736 3.258 0.0238 2.566 0.0133 2.020 0.0074
230.00 5.413 0.0799 3.407 0.0259 2.683 0.0145 2.112 0.0081
240.00 5.648 0.0865 3.555 0.0280 2.799 0.0156 2.203 0.0087
250.00 5.883 0.0933 3.703 0.0302 2.916 0.0169 2.295 0.0094
260.00 6.119 0.1003 3.851 0.0325 3.033 0.0181 2.387 0.0101
270.00 6.354 0.1075 3.999 0.0348 3.149 0.0195 2.479 0.0109
280.00 6.589 0.1150 4.147 0.0372 3.266 0.0208 2.571 0.0116
290.00 6.825 0.1228 4.295 0.0397 3.382 0.0222 2.662 0.0124
300.00 7.060 0.1307 4.443 0.0423 3.499 0.0237 2.754 0.0132
320.00 4.739 0.0477 3.732 0.0267 2.938 0.0149
340.00 5.036 0.0534 3.966 0.0298 3.122 0.0167
360.00 5.332 0.0593 4.199 0.0332 3.305 0.0185
380.00 5.628 0.0656 4.432 0.0366 3.489 0.0205
400.00 5.924 0.0721 4.665 0.0403 3.672 0.0225
420.00 6.221 0.0789 4.899 0.0441 3.856 0.0246
440.00 6.517 0.0860 5.132 0.0481 4.040 0.0268
460.00 6.813 0.0934 5.365 0.0522 4.223 0.0291
480.00 7.109 0.1011 5.598 0.0565 4.407 0.0315
500.00 7.405 0.1090 5.832 0.0609 4.591 0.0340

hf= Pérdida de carga en metro de columna de agua por cada metro de tubería
V = Velocidad en metros por segundo (m/s)

20
Tabla de Pérdida de Carga para Tubería
PAVCO WAVIN BIAXIAL PN8
DARCY-WEISBACH / Ks=0.00000150m / Presión Nominal: 8 BAR / Viscosidad Cinemática del Flujo=0.000000894m2/s / Temperatura 25º C
Diámetro Nominal mm 90 110 160 200 250 315 355 400
Diámetro Interior mm 85.6 105.2 153 191.2 239 301.2 339.4 382.4
CAUDAL Vel. hf Vel. hf Vel. hf Vel. hf Vel. hf Vel. hf Vel. hf Vel. hf
l/s m/s m m/s m m/s m m/s m m/s m m/s m m/s m m/s m
3.00 0.521 0.0034
4.00 0.695 0.0057
5.00 0.869 0.0084 0.575 0.0031
6.00 1.043 0.0117 0.690 0.0044
7.00 1.216 0.0154 0.805 0.0057
8.00 1.390 0.0196 0.920 0.0073
9.00 1.564 0.0243 1.035 0.0090
10.00 1.738 0.0294 1.150 0.0109 0.544 0.0018
11.00 1.911 0.0349 1.266 0.0129 0.598 0.0021
12.00 2.085 0.0409 1.381 0.0151 0.653 0.0025
13.00 2.259 0.0472 1.496 0.0175 0.707 0.0029
14.00 2.433 0.0540 1.611 0.0200 0.761 0.0033
15.00 2.606 0.0613 1.726 0.0227 0.816 0.0037 0.522 0.0013
16.00 2.780 0.0689 1.841 0.0255 0.870 0.0042 0.557 0.0014
17.00 2.954 0.0769 1.956 0.0284 0.925 0.0047 0.592 0.0016
18.00 3.128 0.0853 2.071 0.0315 0.979 0.0052 0.627 0.0018
19.00 3.302 0.0942 2.186 0.0348 1.033 0.0057 0.662 0.0020
20.00 3.475 0.1034 2.301 0.0382 1.088 0.0063 0.697 0.0022
25.00 2.876 0.0573 1.360 0.0094 0.871 0.0032 0.557 0.0011
30.00 3.451 0.0799 1.632 0.0131 1.045 0.0045 0.669 0.0015
35.00 4.027 0.1059 1.904 0.0173 1.219 0.0059 0.780 0.0020
40.00 2.176 0.0221 1.393 0.0075 0.892 0.0026 0.561 0.0008
45.00 2.448 0.0274 1.567 0.0093 1.003 0.0032 0.632 0.0010
50.00 2.720 0.0332 1.741 0.0113 1.115 0.0039 0.702 0.0013 0.553 0.0007
55.00 2.992 0.0395 1.916 0.0134 1.226 0.0046 0.772 0.0015 0.608 0.0008
60.00 3.263 0.0463 2.090 0.0158 1.337 0.0054 0.842 0.0018 0.663 0.0010 0.522 0.0006
65.00 3.535 0.0536 2.264 0.0182 1.449 0.0062 0.912 0.0020 0.718 0.0011 0.566 0.0006
70.00 3.807 0.0614 2.438 0.0209 1.560 0.0071 0.982 0.0023 0.774 0.0013 0.609 0.0007
75.00 4.079 0.0697 2.612 0.0237 1.672 0.0081 1.053 0.0026 0.829 0.0015 0.653 0.0008
80.00 4.351 0.0785 2.786 0.0266 1.783 0.0091 1.123 0.0030 0.884 0.0017 0.697 0.0009
85.00 4.623 0.0877 2.960 0.0298 1.895 0.0101 1.193 0.0033 0.940 0.0019 0.740 0.0010
90.00 4.895 0.0974 3.135 0.0331 2.006 0.0112 1.263 0.0037 0.995 0.0021 0.784 0.0012
95.00 5.167 0.1076 3.309 0.0365 2.118 0.0124 1.333 0.0041 1.050 0.0023 0.827 0.0013
100.00 3.483 0.0401 2.229 0.0136 1.403 0.0045 1.105 0.0025 0.871 0.0014
110.00 3.831 0.0478 2.452 0.0162 1.544 0.0053 1.216 0.0030 0.958 0.0017
120.00 4.179 0.0560 2.675 0.0190 1.684 0.0062 1.326 0.0035 1.045 0.0020
130.00 4.528 0.0649 2.898 0.0220 1.824 0.0072 1.437 0.0040 1.132 0.0023
140.00 4.876 0.0744 3.121 0.0252 1.965 0.0082 1.547 0.0046 1.219 0.0026
150.00 5.224 0.0845 3.344 0.0286 2.105 0.0093 1.658 0.0052 1.306 0.0029
160.00 5.573 0.0952 3.566 0.0322 2.246 0.0105 1.769 0.0059 1.393 0.0033
170.00 5.921 0.1065 3.789 0.0360 2.386 0.0117 1.879 0.0066 1.480 0.0037
180.00 4.012 0.0400 2.526 0.0130 1.990 0.0073 1.567 0.0041
190.00 4.235 0.0442 2.667 0.0144 2.100 0.0081 1.654 0.0045
200.00 4.458 0.0486 2.807 0.0158 2.211 0.0089 1.741 0.0050
210.00 4.681 0.0531 2.947 0.0173 2.321 0.0097 1.828 0.0054
220.00 4.904 0.0579 3.088 0.0188 2.432 0.0106 1.916 0.0059
230.00 5.127 0.0629 3.228 0.0205 2.542 0.0115 2.003 0.0064
240.00 5.350 0.0680 3.368 0.0221 2.653 0.0124 2.090 0.0070
250.00 5.573 0.0733 3.509 0.0238 2.763 0.0134 2.177 0.0075
260.00 5.795 0.0788 3.649 0.0256 2.874 0.0144 2.264 0.0081
270.00 6.018 0.0845 3.789 0.0275 3.984 0.0154 2.351 0.0086
280.00 6.241 0.0904 3.930 0.0294 3.095 0.0165 2.438 0.0092
290.00 6.464 0.0965 4.070 0.0313 3.205 0.0176 2.525 0.0098
300.00 6.687 0.1027 4.210 0.0334 3.316 0.0187 2.612 0.0105
310.00 4.351 0.0354 3.426 0.0198 2.699 0.0111
320.00 4.491 0.0376 3.537 0.0210 2.786 0.0118
330.00 4.631 0.0398 3.648 0.0223 2.873 0.0125
340.00 4.772 0.0420 3.758 0.0235 2.960 0.0132
350.00 4.912 0.0443 3.869 0.0248 3.047 0.0139
360.00 5.052 0.0467 3.979 0.0262 3.135 0.0147
370.00 5.193 0.0491 4.090 0.0275 3.222 0.0154
380.00 5.333 0.0516 4.200 0.0289 3.309 0.0162
390.00 5.473 0.0541 4.311 0.0303 3.396 0.0170
400.00 5.614 0.0567 4.421 0.0318 3.483 0.0178
410.00 5.754 0.0594 4.532 0.0332 3.570 0.0186
420.00 5.895 0.0621 4.642 0.0347 3.657 0.0195
430.00 6.035 0.0649 4.753 0.0363 3.744 0.0203
440.00 6.175 0.0677 4.863 0.0379 3.831 0.0212
450.00 6.316 0.0706 4.974 0.0395 3.918 0.0221
460.00 6.456 0.0735 5.084 0.0411 4.005 0.0230
470.00 6.596 0.0765 5.195 0.0428 4.092 0.0240
480.00 6.737 0.0795 5.306 0.0445 4.179 0.0249
490.00 6.877 0.0826 5.416 0.0462 4.266 0.0259
500.00 7.017 0.0858 5.527 0.0480 4.354 0.0269
hf= Pérdida de carga en metro de columna de agua por cada metro de tubería
V = Velocidad en metros por segundo (m/s)
21
Tabla de Pérdida de Carga para Tubería
PAVCO WAVIN BIAXIAL PN10
DARCY-WEISBACH / Ks=0.00000150m / Presión Nominal: 10 BAR / Viscosidad Cinemática del Flujo=0.000000894m2/s / Temperatura 25º C
Diámetro Nominal mm 90 110 160 200 250 315 355 400
Diámetro Interior mm 85.6 105.2 153 191.2 239 301.2 339.4 382.4
CAUDAL Vel. hf Vel. hf Vel. hf Vel. hf Vel. hf Vel. hf Vel. hf Vel. hf
l/s m/s m m/s m m/s m m/s m m/s m m/s m m/s m m/s m
3.00 0.539 0.0037
4.00 0.718 0.0061
5.00 0.898 0.0091 0.577 0.0032
6.00 1.078 0.0127 0.693 0.0044
7.00 1.257 0.0167 0.808 0.0058
8.00 1.437 0.0213 0.924 0.0074
9.00 1.616 0.0263 1.039 0.0091
10.00 1.796 0.0318 1.155 0.0110 0.545 0.0018
11.00 1.976 0.0378 1.270 0.0131 0.600 0.0022
12.00 2.155 0.0442 1.386 0.0153 0.654 0.0025
13.00 2.335 0.0512 1.501 0.0177 0.709 0.0029
14.00 2.514 0.0585 1.617 0.0202 0.763 0.0033
15.00 2.694 0.0663 1.732 0.0229 0.818 0.0038 0.524 0.0013
16.00 2.873 0.0746 1.848 0.0257 0.873 0.0042 0.558 0.0014
17.00 3.053 0.0833 1.963 0.0287 0.927 0.0047 0.593 0.0016
18.00 3.233 0.0924 2.079 0.0318 0.982 0.0052 0.628 0.0018
19.00 3.412 0.1020 2.194 0.0351 1.036 0.0058 0.663 0.0020
20.00 3.592 0.1120 2.310 0.0385 1.091 0.0063 0.698 0.0022
25.00 2.887 0.0578 1.363 0.0095 0.873 0.0032 0.558 0.0011
30.00 3.465 0.0807 1.636 0.0132 1.047 0.0045 0.670 0.0015
35.00 4.042 0.1069 1.909 0.0174 1.222 0.0059 0.781 0.0020
40.00 2.181 0.0222 1.396 0.0076 0.893 0.0026 0.562 0.0008
45.00 2.454 0.0275 1.571 0.0094 1.005 0.0032 0.632 0.0010
50.00 2.727 0.0334 1.745 0.0114 1.116 0.0039 0.703 0.0013 0.553 0.0007
55.00 2.999 0.0397 1.920 0.0135 1.228 0.0046 0.773 0.0015 0.609 0.0008
60.00 3.272 0.0466 2.094 0.0158 1.340 0.0054 0.843 0.0018 0.664 0.0010 0.523 0.0006
65.00 3.545 0.0539 2.269 0.0183 1.451 0.0062 0.913 0.0020 0.719 0.0011 0.567 0.0006
70.00 3.817 0.0618 2.443 0.0210 1.563 0.0071 0.984 0.0023 0.775 0.0013 0.610 0.0007
75.00 4.090 0.0701 2.618 0.0238 1.675 0.0081 1.054 0.0026 0.830 0.0015 0.654 0.0008
80.00 4.363 0.0789 2.792 0.0268 1.786 0.0091 1.124 0.0030 0.885 0.0017 0.697 0.0009
85.00 4.635 0.0883 2.967 0.0299 1.898 0.0102 1.195 0.0033 0.941 0.0019 0.741 0.0011
90.00 4.908 0.0980 3.141 0.0332 2.009 0.0113 1.265 0.0037 0.996 0.0021 0.784 0.0012
95.00 5.181 0.1083 3.316 0.0367 2.121 0.0124 1.335 0.0041 1.051 0.0023 0.828 0.0013
100.00 3.490 0.0403 2.233 0.0137 1.405 0.0045 1.107 0.0025 0.872 0.0014
110.00 3.839 0.0480 2.456 0.0163 1.546 0.0053 1.217 0.0030 1.959 0.0017
120.00 4.188 0.0563 2.679 0.0191 1.686 0.0062 1.328 0.0035 1.046 0.0020
130.00 4.537 0.0653 2.903 0.0221 1.827 0.0072 1.439 0.0040 1.133 0.0023
140.00 4.886 0.0748 3.126 0.0253 1.967 0.0083 1.549 0.0046 1.220 0.0026
150.00 5.235 0.0849 3.349 0.0287 2.108 0.0094 1.660 0.0053 1.307 0.0030
160.00 5.584 0.0957 3.572 0.0324 2.249 0.0105 1.771 0.0059 1.395 0.0033
170.00 5.933 0.1070 3.796 0.0362 2.389 0.0118 1.881 0.0066 1.482 0.0037
180.00 4.019 0.0402 2.530 0.0131 1.992 0.0073 1.569 0.0041
190.00 4.242 0.0444 2.670 0.0144 2.103 0.0081 1.656 0.0045
200.00 4.466 0.0488 2.811 0.0159 2.213 0.0089 1.743 0.0050
210.00 4.689 0.0534 2.951 0.0174 2.324 0.0097 1.830 0.0055
220.00 4.912 0.0581 3.092 0.0189 2.435 0.0106 1.918 0.0059
230.00 5.135 0.0631 3.232 0.0205 2.545 0.0115 2.005 0.0065
240.00 5.359 0.0683 3.373 0.0222 2.656 0.0124 2.092 0.0070
250.00 5.582 0.0736 3.513 0.0239 2.767 0.0134 2.179 0.0075
260.00 5.805 0.0792 3.654 0.0257 2.877 0.0144 2.266 0.0081
270.00 6.028 0.0849 3.794 0.0276 2.988 0.0154 2.353 0.0087
280.00 6.252 0.0908 3.935 0.0295 3.099 0.0165 2.441 0.0093
290.00 6.475 0.0969 4.075 0.0314 3.209 0.0176 2.528 0.0099
300.00 6.698 0.1031 4.216 0.0335 3.320 0.0187 2.615 0.0105
310.00 4.357 0.0355 3.431 0.0199 2.702 0.0112
320.00 4.497 0.0377 3.541 0.0211 2.789 0.0118
330.00 4.638 0.0399 3.652 0.0223 2.876 0.0125
340.00 4.778 0.0422 3.763 0.0236 2.964 0.0132
350.00 4.919 0.0445 3.873 0.0249 3.051 0.0139
360.00 5.059 0.0468 3.984 0.0262 3.138 0.0147
370.00 5.200 0.0493 4.094 0.0276 3.225 0.0155
380.00 5.340 0.0518 4.205 0.0290 3.312 0.0162
390.00 5.481 0.0543 4.316 0.0304 3.399 0.0170
400.00 5.621 0.0569 4.426 0.0318 3.486 0.0178
410.00 5.762 0.0596 4.537 0.0333 3.574 0.0187
420.00 5.902 0.0623 4.648 0.0348 3.661 0.0195
430.00 6.043 0.0651 4.758 0.0364 3.748 0.0204
440.00 6.183 0.0679 4.869 0.0380 3.835 0.0213
450.00 6.324 0.0708 4.980 0.0396 3.922 0.0222
460.00 6.465 0.0737 5.090 0.0412 4.009 0.0231
470.00 6.605 0.0767 5.201 0.0429 4.097 0.0240
480.00 6.746 0.0798 5.312 0.0446 4.184 0.0250
490.00 6.886 0.0829 5.422 0.0463 4.271 0.0259
500.00 7.027 0.0861 5.533 0.0481 4.358 0.0269
22 hf= Pérdida de carga en metro de columna de agua por cada metro de tubería
V = Velocidad en metros por segundo (m/s)
Tabla de Pérdida de Carga para Tuberías
PAVCO WAVIN BIAXIAL PN16
DARCY-WEISBACH / Ks=0.00000150m / Presión Nominal: 16 BAR / Viscosidad Cinemática del Flujo=0.000000894m2/s / Temperatura 25º C
Diámetro Nominal mm 90 110 160 200 250 315 355 400
Diámetro Interior mm 85.6 105.2 153 191.2 239 301.2 339.4 382.4
CAUDAL Vel. hf Vel. hf Vel. hf Vel. hf Vel. hf Vel. hf Vel. hf Vel. hf
l/s m/s m m/s m m/s m m/s m m/s m m/s m m/s m m/s m
3.00 0.579 0.0044
4.00 0.772 0.0073
5.00 0.966 0.0109 0.610 0.3611
6.00 1.159 0.0151 0.731 0.5003
7.00 1.352 0.0199 0.853 0.6595
8.00 1.545 0.0253 0.975 0.8382
9.00 1.738 0.0313 1.097 1.0360 0.518 0.0017
10.00 1.931 0.0379 1.219 1.2524 0.575 0.0021
11.00 2.124 0.0450 1.341 1.4873 0.633 0.0024
12.00 2.317 0.0527 1.463 1.7402 0.690 0.0029
13.00 2.510 0.0609 1.585 2.0111 0.748 0.0033
14.00 2.703 0.0697 1.707 2.2995 0.805 0.0038
15.00 2.897 0.0790 1.829 2.6055 0.863 0.0043 0.515 0.0013
16.00 2.090 0.0889 1.950 2.9287 0.920 0.0048 0.552 0.0015
17.00 2.283 0.0992 2.072 3.2690 0.978 0.0054 0.589 0.0016
18.00 3.476 0.1101 2.194 3.6262 1.035 0.0059 0.626 0.0018
19.00 3.669 0.1215 2.316 4.0003 1.093 0.0065 0.662 0.0020
20.00 3.862 0.1335 2.438 4.3910 1.150 0.0072 0.699 0.0022
25.00 3.048 6.5911 1.438 0.0108 0.736 0.0025 0.588 0.0013
30.00 3.657 9.1930 1.725 0.0150 0.920 0.0037 0.706 0.0017
35.00 4.267 12.1870 2.013 0.0198 1.104 0.0051 0.824 0.0023 0.518 0.0008
40.00 2.300 0.0253 1.288 0.0068 0.941 0.0029 0.592 0.0010
45.00 2.588 0.0313 1.472 0.0086 1.059 0.0036 0.666 0.0012 0.525 0.0007
50.00 2.875 0.0380 1.656 0.0107 1.177 0.0044 0.741 0.0014 0.583 0.0008
55.00 3.163 0.0452 1.840 0.0129 1.294 0.0052 0.815 0.0017 0.641 0.0010
60.00 3.450 0.0530 2.024 0.0154 1.412 0.0061 0.889 0.0020 0.700 0.0011 0.551 0.0006
65.00 3.738 0.0613 2.208 0.0180 1.530 0.0071 0.963 0.0023 0.758 0.0013 0.597 0.0007
70.00 4.025 0.0703 2.392 0.0208 1.647 0.0081 1.037 0.0027 0.816 0.0015 0.643 0.0008
75.00 4.313 0.0798 2.576 0.0239 1.765 0.0092 1.111 0.0030 0.875 0.0017 0.689 0.0009
80.00 4.600 0.0898 2.760 0.0271 1.883 0.0103 1.185 0.0034 0.933 0.0019 0.734 0.0011
85.00 4.888 0.1004 2.944 0.0305 2.000 0.0115 1.259 0.0038 0.991 0.0021 0.780 0.0012
90.00 5.175 0.1115 3.128 0.0340 2.118 0.0128 1.333 0.0042 1.050 0.0024 0.826 0.0013
95.00 5.463 0.1232 3.312 0.0378 2.236 0.0141 1.407 0.0046 1.108 0.0026 0.872 0.0015
100.00 3.496 0.0417 2.353 0.0155 1.481 0.0051 1.166 0.0028 0.918 0.0016
110.00 3.680 0.0458 2.589 0.0185 1.629 0.0060 1.283 0.0034 1.010 0.0019
120.00 4.048 0.0546 2.824 0.0217 1.777 0.0071 1.400 0.0040 1.102 0.0022
130.00 4.416 0.0641 3.059 0.0251 1.925 0.0082 1.516 0.0046 1.194 0.0026
140.00 4.784 0.0742 3.295 0.0288 2.074 0.0094 1.633 0.0053 1.285 0.0030
150.00 5.152 0.0851 3.530 0.0326 2.222 0.0106 1.750 0.0060 1.377 0.0033
160.00 5.520 0.0966 3.765 0.0368 2.370 0.0120 1.866 0.0067 1.469 0.0038
170.00 5.888 0.1089 4.001 0.0411 2.518 0.0134 1.983 0.0075 1.561 0.0042
180.00 6.257 0.1218 4.236 0.0456 2.666 0.0149 2.099 0.0083 1.653 0.0047
190.00 4.471 0.0504 2.814 0.0164 2.216 0.0092 1.744 0.0052
200.00 4.707 0.0554 2.962 0.0180 2.333 0.0101 1.836 0.0057
210.00 4.942 0.0606 3.110 0.0197 2.449 0.0111 1.928 0.0062
220.00 5.177 0.0661 3.258 0.0215 2.566 0.0120 2.020 0.0067
230.00 5.413 0.0717 3.407 0.0233 2.683 0.0131 2.112 0.0073
240.00 5.648 0.0776 3.555 0.0252 2.799 0.0141 2.203 0.0079
250.00 5.883 0.0837 3.703 0.0272 2.916 0.0152 2.295 0.0085
260.00 6.119 0.0900 3.851 0.0292 3.033 0.0164 2.387 0.0092
270.00 6.354 0.0965 3.999 0.0313 3.149 0.0175 2.479 0.0098
280.00 6.589 0.1032 4.147 0.0335 3.266 0.0187 2.571 0.0105
290.00 6.825 0.1101 4.295 0.0357 3.382 0.0200 2.662 0.0112
300.00 7.060 0.1172 4.443 0.0380 3.499 0.0213 2.754 0.0119
310.00 4.591 0.0404 3.616 0.0226 2.846 0.0127
320.00 4.739 0.0428 3.732 0.0240 2.938 0.0134
330.00 4.888 0.0453 3.849 0.0254 3.030 0.0142
340.00 5.036 0.0479 3.966 0.0268 3.122 0.0150
350.00 5.184 0.0505 4.082 0.0283 3.213 0.0158
360.00 5.332 0.0532 4.199 0.0298 3.305 0.0167
370.00 5.480 0.0560 4.316 0.0313 3.397 0.0175
380.00 5.628 0.0588 4.432 0.0329 3.489 0.0184
390.00 5.776 0.0617 4.549 0.0345 3.581 0.0193
400.00 5.924 0.0647 4.665 0.0362 3.672 0.0203
410.00 6.072 0.0677 4.782 0.0379 3.764 0.0212
420.00 6.221 0.0708 4.899 0.0396 3.856 0.0221
430.00 6.369 0.0739 5.015 0.0414 3.948 0.0231
440.00 6.517 0.0772 5.132 0.0431 4.040 0.0241
450.00 6.665 0.0804 5.249 0.0450 4.131 0.0251
460.00 6.813 0.0838 5.365 0.0468 4.223 0.0262
470.00 6.961 0.0872 5.482 0.0487 4.315 0.0272
480.00 7.109 0.0907 5.598 0.0507 4.407 0.0283
490.00 7.257 0.0942 5.715 0.0527 4.499 0.0294
500.00 7.405 0.0978 5.832 0.0547 4.591 0.0305
hf= Pérdida de carga en metro de columna de agua por cada metro de tubería
V = Velocidad en metros por segundo (m/s)
23
Cálculo de Golpe de Ariete Para disminuir este riesgo se deben tomar
Definición las siguientes precauciones:
Una columna de líquido moviéndose tiene inercia, que es Mantener siempre baja velocidad, especialmente en
proporcional a su peso y a su velocidad. Cuando el flujo diámetros grandes. Durante el llenado de la Tubería,
se detiene rápidamente, por ejemplo al cerrar una válvu- la velocidad no debe ser mayor de 0.3 m/seg., hasta
la, la inercia se convierte en un incremento de presión. que todo el aire salga y la presión llegue a su valor
Entre más larga de línea y más alta la velicdad del líquido, nominal.
mayor será la sobrecarga de presión.
2. Instalar ventosas de doble efecto, en los puntos
Estas sobrepresiones pueden llegar a ser lo sufientemen- altos, bajos y a lo largo de tramos rectos, muy largos,
te grandes para reventar cualquier tipo de tubería. Este para purgar el aire, y permitir su entrada cuando se
fenómeno se conoce con el nombre de Golpe de Ariete. interrumpe el servicio.
Las principales causas de este fenómeno son: 3. Durante la operación de la línea,prevenir la entrada
1. La apertura y el cierre rápidos de una válvula del aire en las bocatomas, rejillas, etc., de manera
2. El arranque y la parada de una bomba que el flujo de agua sea continuo.
3. La acumulación y el movimiento de bolsas de aire dentro
de las Tuberías
Nota Importante:
Al cerrar una válvula, la sobrepresión Los parámetros de diseño de un proyecto y obra, son de
máxima que se puede esperar se calcula así: única responsabilidad del diseñador.

Fórmula:
Valores de “a” en función del RDE
aV
P = con: SDR a(m/s)
g
21 436
29 371
1420
a = 33 352
1 + (K/E) (RDE-2) 41 312
45.8 295

Donde:
P: Sobrepresión máxima en metros de columna de agua, Diseño de Anclaje
al cerrar bruscamente la válvula.
a: Velocidad de la onda (m/s).
Cuando una Tubería está sujeta a presión hidrostática
V: Cambio de velocidad del agua (m/s).
interna, esta presión actúa igualmente en todas las
g: Aceleración de la gravedad = 9.81 m/s2
paredes de la Tubería produciendo ‘‘fuerzas de empuje’’.
K: Módulo de compresión del agua = 2.06 x 104 Kg/cm2
Es esencial eliminar los movimientos debidos a estos
E: Módulo de elasticidad de la Tubería
empujes cuando la Tubería no está unida por soldadura o
(2.81 x 104 Kg/cm2 para PVC Tipo 1, Grado1)
flanches. Debe proveerse empotramiento externo en
RDE: Relación diámetro exterior/espesor mínimo.
todas las tees, curvas, tapones, válvulas, etc. para
resistir las fuerzas de empuje. Debido a la flexibilidad
intrínseca de PVC, es además importante diseñar los
empotramientos en las curvas para contrarrestar la
tendencia a desacoplarse. Estos anclajes se requieren
en:

24
• Cambios de dirección
EMPUJE DESARROLLADO POR UNA PRESIÓN DE 100psi
• Cambios en tamaño, reducciones
Diámetro Válvulas, TEES,
• Tapones en terminales ciegas Nominal
Codo 90o Codo 45o
Tapones Ciegos
• Conexiones a válvulas, hidrantes, ya que se crea empuje cuando
pulgadas (mm) Lb fuerza (N) Lb fuerza (N) Lb fuerza (N)
se cierran
4 1.800 (8.007) 1.100 (4.893) 1.300 (5.783)
6 4.000 (17.793) 2.300 (10.231) 2.900 (12.900)
El tamaño y tipo de esos bloques o anclajes para el empuje depen- 8 7.200 (32.027) 4.100 (18.238) 5.100 (22.686)
den de: 10 11.200 (48.820) 6.300 (28.024) 7.900 (35.141)
12 16.000 (71.172) 9.100 (40.479) 11.300 (50.265)
• Presión máxima de operación o de prueba del sistema Tomado de AWWA M23
• Diámetro de la Tubería
• Diámetro de los Accesorios
• Tipo de Accesorios o conexiones Para dimensionar los bloques hay varios métodos, uno de ellos
• Perfil de la línea es asumir la capacidad de soporte del suelo. A continuación se
• Resistencia del suelo indican valores de acuerdo con el tipo de suelo y son estima-
das bajo la premisa de que la profundidad de suelo saturado
excede 0.60m. Para mayor seguridad, los valores de capaci-
Tipo de Anclaje dad de carga del suelo deben ser determinados para cada
TEE USADA COMO
CODO PARA FUTURA
proyecto en particular.
VALVULA PROLONGACION

Tipo de Suelo Lb/pie2 N/m 2

Turba 0 0
Arcilla suave 500 23.940
Arena 1.000 47.881
Arena y grava 1.500 71.821
Arena y grava con arcilla 2.000 97.761
CAMBIO DE DIAMETRO CRUZ USADA COMO
Arena y grava cementada con arcilla 4.000 191.523
DE REDUCCION CODO PARA
Arcillas impermeables consolidadas 5.000 239.403
PROLONGACIONES FUTURAS
Tomado de AWWA M2

Nota: El concreto no debe envolver totalmente la Tubería o


accesorio PAVCO ya que con los cambios de presión interna
se presentan variaciones en el diámetro externo que no se
deben impedir, pues causaría esfuerzos innecesarios en la
pared del tubo. Para esto es buena práctica aislar la Tubería
con un fieltro asfáltico o un polietileno grueso colocado entre
CAMBIO DE DIRECCION CAMBIO DE DIRECCION la Tubería o accesorio PAVCO y el concreto.
CON CODO

Diseño de Curvatura Longitudinal


La respuesta de PVC-O-BIAXIAL a la curvatura longitudinal es
una gran ventaja en instalaciones enterradas. Estas curvaturas
pueden hacerse para cambiar el alineamiento para evitar
DERIVACION EN TEE
DERIVACION EN YEE obstrucciones o puede simplemente ocurrir en respuesta a
situaciones no planeadas, tales como asentamientos diferen-
ciales de válvulas e hidrantes a los que la tubería está
rígidamente conectada, asentamientos disparejos o erosión
del encamado de la tubería, movimientos del suelo debidos a
variaciones a las condiciones de humedad, presencia de nivel
freático o movimientos sísmicos.
CAMBIO DE DIRECCION CRUZ USADA COMO TEE
VERTICAL

25
Para el cálculo de la curvatura longitudinal a que puede someterse la Tubería, sin considerar deflexión longitudinal en las uniones:

Cálculo de la tensión de curvatura permitida: Donde:


HDB: Base Hidrostática de Diseño
Fórmula:
St: HDB/2, Esfuerzo de Tensión, psi
SF: Factor de Seguridad, 2
Sb = (HDB - St) T T: Factor de Corrección de Presión de Trabajo con la Temperatura
SF

El Momento inducido por la curvatura longitudinal, Donde:


M: Momento de la curvatura, pulg-lb
Fórmula:
c: DE/2, distancia de la fibra externa al eje neutro, pulg.
l: Momento de inercia, pulg.
M = Sb l
c

En Tuberías de pared sólida, Donde:


DE: Diámetro exterior, pulg
Fórmula:
DI: Diámetro Interior, pulg
π
l = (DE4 - DI4) = 0.0491 (DE4 - DI4)
64

Asumiendo que la curvatura conforma un arco circular, el radio mínimo en pulgadas, Rb, será:

Fórmula: Donde:
Además de los definidos arriba,
I Módulo de Elasticidad de la Tubería, psi
Rb = E E:
M

El valor del ángulo ß en grados, formado por la longitud de la Tubería L,

Fórmula: ß= 360L
2πRb

Con L y Rb con iguales unidades de longitud.


El valor del ángulo oc de la deflexión de la Tubería curvada desde una tangente al círculo,

Fórmula:
oc = ß
2
La distancia perpendicular desde la tangente del círculo hasta el extremo de la Tubería,
Fórmula: 2
Seno ß
A = 2RB
2

Si se asume que durante la instalación, la Tubería está temporalmente fija en un extremo y actúa como una
viga en cantilever, la fuerza lateral requerida para obtener el desplazamiento A es:

Fórmula: A
P = 3 E I
L3

26
Curvatura Longitudinal Permitida para Tubería de PVC

Curvatura para Biaxial®


E 400,000 psi
HDB Longitudinal 4,500 psi
SF 2
Cálculos a 23ºC
Para obtener las curvaturas longitudinales se hace necesario
bloquear las uniones para asegurar la alineación recta de éstas.

Cuando el valor de ß necesario supera el valor permitido para


una longitud dada de tubería, la curvatura longitudinal debe ser
alcanzada distribuyéndola en varias longitudes de tubería.

CURVATURA PARA BIAXIAL

Diámetro Diámetro Espesor de Pared Diámetro Interior Longitud a ß A P


Nominal Exterior mm mm Deflectar Grados m Kg

mm mm PN 8 PN 10 PN 16 PN 8 PN 10 PN 16 m PN 8 PN 10 PN 16 PN 8 PN 10 PN 16 PN 8 PN 10 PN 16

90 90 2.2 2.90 4.40 85.20 84.20 81.20 19.33 19.33 19.33 0.90 0.90 0.90 4.11 5.29 7.62
110 110 2.4 2.50 3.90 105.20 105.00 102.20 15.81 15.81 15.81 0.74 0.74 0.74 6.76 7.02 10.55
160 160 3.5 3.60 5.60 153.00 152.80 148.80 10.87 10.87 10.87 0.51 0.51 0.51 20.91 21.50 32.20
200 200 4.4 4.50 7.00 191.20 191.00 186.00 5.40 8.7 8.7 8.7 0.41 0.41 0.41 41.16 42.03 62.95
250 250 5.5 5.60 8.70 239.00 238.80 232.60 6.96 6.96 6.96 0.33 0.33 0.33 80.44 81.81 122.41
315 315 6.9 7.00 10.90 301.20 301.00 293.20 5.52 5.52 5.52 0.26 0.26 0.26 160.34 162.50 243.74
355 355 7.8 7.90 12.30 339.40 339.20 330.40 4.90 4.90 4.90 0.23 0.23 0.23 230.19 232.95 349.34
400 400 8.8 8.90 13.80 382.40 382.20 372.40 4.35 4.35 4.35 0.20 0.20 0.20 329.74 333.23 497.90

27
Cálculo de la Cimentación

El diseño de la cimentación se hace controlando la deflexión causada por la carga muerta y viva, usando la Ecuación
de lowa modificada:

Donde:
DL: Factor de Deflexión (1.5) ó 1 Para condición de zanja.
Fórmula:
(Marston) o Condición Prisma.
K: Constante de Encamado (0.10) Asumido. (Marston)
(DL x K x P x K x W) (100)
% Deflexión = P: Presión Carga Muerta, kg/m2 (psi) Depende del tipo de relleno.
0.149 x PS + 0.061 x E´ (Suelo SM y SC)
W: Presión de Carga Viva, kg/m2 (psi) Fórmula de Boussinesq.
PS: Rigidez kg/m2 (psi) Rigidez de los tubos BIAXIAL® de PAVCO
E´: Módulo del Suelo kg/m2 (psi) Capacidad del suelo de resistir deflexión.

E’ para Grado de Compactación del Relleno en psi


Baja, <85% Moderado, 85% - Alta, >95%
Clase de Suelo Proctor, <40% 95%Proctor, 40% - Proctor, >70%
Densidad Relativa 70% Densidad Relativa Densidad Relativa
Piedra Quebrada
1000 3000 3000 3000
(Clase I)

GW, GP, SW, SP


(Clase II) 200 1000 2000 3000

GM, GC, SM, SC


(Clase III) 100 400 1000 2000

ML,CL, ML - CL
(Clase IV) 50 200 400 1000

Exactitud en Términos
de % de Deflexión ±2 ±2 ±1 ±0.5

Con: Donde:
PS: Rigidez de Tubería, psi
El
PS = E: Módulo de Elasticidad, 400.000 psi
0.149 r3 I: Momento de Inercia de la pared en la sección transversal por unidad
de longitud de Tubería, pulg4 /pulg
R: Radio promedio, RE - t, pulg

Para tubos de pared sólida, Donde:


t3 t: espesor mínimo de pared, pulg
I =
12

3
t DE 4,47 E 4,47 E
Entonces: PS = 0,559 E como: RDE = Entonces: PS = =
DE -1 3 (RDE-1)3
r t
t

28
Guia de instalación

Recepción, Transporte, Almacenamiento


Almacenamiento y Manipulación ®
La Tubería PVCO-BIAXIAL deben almacenarse horizontal-
mente en una zona plana, aislada del terreno por apoyos
espaciados 1.5m de tal forma que se evite el pandeo de los
Recepción en Obra tubos y que no queden en contacto con los extremos.
Deben apilarse en una altura máxima de 1.5m, colocando
A la llegada de la Tubería PVC-O-BIAXIAL a la obra, deben abajo la tubería más pesada y revisando que no se cause
inventariarse e inspeccionarse, de tal forma que se verifique deformación a los tubos.
la adecuada condición y de acuerdo a lo solicitado.
Las campanas deben quedar libres e intercaladas
campanas y espigos.

Si el almacenamiento a la intemperie va a ser mayor a 30


días, debe protegerse de la luz directa del sol con un
material opaco pero manteniendo adecuada ventilación.

Transporte
Es la práctica ideal, usar vehículos de superficie de carga
lisa, libre de clavos
o tornillos salientes para evitar daños.

Cuando se transportan distintos diámetros en el mismo


viaje, los diámetros mayores deben colocarse primero en la
parte baja de la plataforma del camión.

Se deben dejar libres las campanas alternando campanas


y espigos para evitar deformaciones innecesarias que
impidan el normal ensamble del sistema.

Se recomienda amarrar los tubos con elementos no metáli-


cos, para que no se produzcan cortaduras. Preferiblemente
se deben usar correas anchas de lona.

No colocar cargas sobre la tubería, en los vehículos de


transporte.
Manipulación NOTA: Cuando hay agua sobre el fondo de la zanja debe
evacuarse para mantener la zanja seca hasta que la
La Tubería PVC-O-BIAXIAL deben descargarse, no Tubería sea instalada y rellenada al menos un diámetro
dejarlos caer, tanto desde el camión de transporte como a sobre la clave de la tubería para evitar flotación.
la zanja. Durante la manipulación deben evitarse los
golpes y abrasión. RELLENO
El fondo de la zanja debe prepararse de tal forma que
La manipulación no requiere equipos, su peso permite asegure un apoyo estable, firme y uniforme a todo lo largo
que sea manual, pero si se quiere izar varios tubos a la de la tubería. Cuando el fondo es inestable, debe
vez, estos elementos de izaje, que entran en contacto con excavarse una profundidad adicional y rellenarse con
la Tubería no deben ser metálicos, preferiblemente material adecuado como fundación. Cuando hay presen-
correas de lona ancha. cia de rocas puntiagudas y grandes, estas deben ser
removidas y proveer un mínimo de 100mm de apoyo con
material adecuado.
Nunca instale la tubería apoyada directamente sobre
rocas o piedras grandes.

Instalación

La apropiada instalación es esencial para el exitoso desem-


®
peño de las Tuberías BIAXIAL de PAVCO.

Excavación
La tubería para agua a presion se instala normalmente a
una profundidad mínima de 1.0 m sobre la clave del tubo,
pero a criterio del consultor debe definirse esta profundidad.
El ancho de la zanja puede variar de acuerdo con las circun-
stancias. Pueden hacerse zanjas tan estrechas como el
DE+100mm, estándares de DE+300mm y máximos
recomendados de DE+600mm.

Los materiales adecuados para el encamado pueden ser


triturado de roca (angular), tamaño máximo de 3/4’’,
canto rodado, tamaño máximo 1.1/2’’, arena lavada,
arenilla, recebo fino o material proveniente de la
excavación si es adecuado. Su selección dependerá de la
disponibilidad local y de la presencia o no de nivel freático,
caso en el cual debe usarse el primero.

30
Alrededor de la tubería y hasta 100mm sobre la corona • No someta la tubería a contacto directo con elementos
del tubo debe usarse un material fino, libre de piedras, punzantes, tales como herramientas metálicas o piedras
compactado adecuadamente, usando pisones de mano. angulosas mayores a 3/4”.

Después de cubrir al menos 300mm sobre la corona del • Consulte con nosotros condiciones especiales no cubier-
tubo, puede usarse equipo de compactación mecánico. tas por este ma- nual en los teléfonos que aparecen en
la contraportada de este manual.
Instalaciones Especiales
Cuando la tubería va a estar expuesta a la radiación solar, Ensamble de la Tubería:
debe cubrirse con un techo opaco o protegerse con una
pintura que cumpla con las siguientes características: Preparación
Limpie cuidadosamente el interior de la campana así como
• No debe necesitar solvente o tener base en Thinner. el espigo, antes de unir.
Esta sustancia no se comporta bien con el PVC
• Debe tener un componente reflectivo, como el aluminio
Aplicando Lubricante
o similar
Lubrique de manera pareja la mitad de la longitud del
• Debe asegurarse la adherencia al PVC con la aplicación
espigo. Mueva el espigo de tal forma que apenas penetre
directa o a través de la aplicación de un ‘’primer’’
en la boca de la unión.

Antes de pintar la tubería debe prepararse la superficie


para asegurar la adherencia; lijar suavemente en seco,
limpiar con limpiador PAVCO y aplicar la pintura.

ZANJA TI PO

RELLENO
FINAL

Alineando la Tubería
COBERTURA Asegúrese que la Tubería están perfectamente alineadas
Mínima = 0.30 m RELLENO en ambos planos. Esto es muy importante. Nunca trate de
Línea Media del Tubo INICIAL
TUBO introducir el espigo en ángulo.
RELLENO LATERAL CIMENTACION
CAMA DE APOYO E’
Mínima = 0.10 m

Bd

Condiciones extremas para el material


• El PVC es un material termoplástico que puede ser
fundido aplicando calor, de tal forma que nunca debe
instalarse, almacenarse o someterse a una fuente de
calor que pueda deformarlo. La temperatura máxima a
que pue- de transportar agua es de 60°C.

• No aplique solventes ni someta la tubería a contacto con


estos.

31
Insertando el espigo en la Unión Anclajes
Empuje el espigo hasta la marca de entrada. Esto debe Los anclajes con bloques de concreto que restrinjan el
hacerse con un movimiento rápido siendo de gran ayuda movimiento de los accesorios y/o de la tubería se hacen
el impulso que se gana entre la boca de entrada y el sello necesarios en todo sistema presurizado. (Ver Diseño de
de caucho. Anclajes en el numeral de Diseño de este Manual). Estos
bloques transmiten al terreno la carga producida por el
empuje de la tubería o de los accesorios.

Es conveniente que la mayor parte de la pared externa


de los accesorios quede envuelta en el concreto, pero no
en su totalidad. Con las variaciones en la presión interna
del sistema ocurren variaciones en el diámetro externo
de la tubería o de los accesorios que no se debe restrin-
Utilice una barra apoyándola sobre un trozo de madera gir.
colocado en el centro del tubo como indica la figura.
Es buena práctica colocar fieltro asfáltico o polietileno
grueso entre la tubería o accesorio PVC-O-BIAXIAL y el
concreto del anclaje.

Acometidas Domiciliarias
Ver Manual Unión Platino Páginas 38 a 42.

Mantenimiento
La Tubería PVC-O-BIAXIAL puede ser ensamblada en el
borde de la zanja y luego instalada en el fondo como se El mantenimiento preventivo debe ser el estipulado por la
muestra en las siguientes imágenes. Empresa de Servicios Públicos que opera el sistema de
agua potable. Pueden usarse los equipos de inspección
y limpieza usualmente dedicados a estas actividades.

Para mantenimiento correctivo, según sea el caso del


daño específico, puede consultarse con PAVCO en los
teléfonos que aparecen en la contraportada de este
manual.

Conexiones Domiciliarias
Las abrazaderas deberan cumplir con la NTP
399.137-2009, Estos accesorios deberan de adaptarse
al diametro exte- rior de la linea de conduccion de agua
potable permitiendo la salida hacia la conexion domici-
liaria.

32
Según NTP - RT - ISO / RT 4191 - 2016:
Puesta en Servicio
• Se deberá llenar lentamente los tubos con agua,
Prueba Hidrostática empezando por el punto más bajo, evitando así el golpe
de ariete y eliminando todo el aire atrapado.

El propósito de esta prueba es verificar los materiales y la Para saber si una tubería que se está probando tiene aire
mano de obra. atrapado, puede hacerse lo siguiente:
El sistema en construcción debe probarse por tramos
1. Presurice con agua a la presión deseada.
terminados, antes de completar todo el sistema. Debe
2. Permita que la presión se reduzca a un cierto nivel.
tenerse en cuenta que el o los tramos a probar deben estar
3. Mida la cantidad de agua requerida para llegar de
suficientemente cubiertos, los anclajes en Accesorios
nuevo a la presión deseada.
suficientemente curados, 3 días al menos, y debidamente
4. Repita los pasos 2 y 3.
restringido el movimiento en los tapones de los extremos.
Si la cantidad de agua requerida para presurizar la línea la
Según NTP - RT - ISO / TR 4191 - 2016: segunda vez es significativamente menor que la requerida
• El ensayo hidrostático de la tubería deberá realizarse a en la primera vez, hay aire atrapado en la línea. Si no hay
temperatura ambiente. una diferencia significativa, hay probable fuga en la línea.”

• Para redes a gran longitud, las pruebas se realizaran en Prueba de Presión


tramos con una longitud La presión de prueba puede ser del orden del 50% sobre
menor de 500m. la presión de operación. La presión de prueba no debe
exceder la presión de diseño de la tubería, de los acceso-
Llenado de la Tubería rios o de los anclajes. La presión debe ser controlada en el
punto más bajo del tramo a probar que no debe ser mayor
La tubería debe llenarse lentamente desde el punto más que la de diseño de la tubería.
bajo de la línea. Debe calcularse la cantidad de agua
necesaria para llenar la línea. Según NTP - RT - ISO / RT 4191 - 2016:
La prueba hidrostática debe realizarse conforme a las
Según NTP - RT - ISO / RT 4191 - 2016:
siguientes condiciones:
• Todas las válvulas de control inmediato deberán abrirse a) Se debe realizar a temperatura ambiente
durante el ensayo. Si una red debe ser sometida a un b) Se debe aplicar por lo menos durante 1h, pero no
ensayo por tramos, los extremos deberán cerrarse exceder las 24h.
temporalmente empleando tapones propios. c) No debe exceder 1,25 a veces la presión asignada
máxima del componente de menor capacidad nominal.
• Los manómetros deberán ser calibrados de acuerdo al
nivel en el cual se ubican. Los orificios de aire ubicados
en puntos elevados deberán abrirse durante el llenado de Prueba de Hermeticidad
la red.”
TEl propósito de esta prueba es verificar que no haya fugas
en las uniones, conexiones a accesorios y otros elementos
Expulsión de Aire del tramo a probar.
La presión de trabajo del tramo puede ser la presión de
Todo el aire debe ser expulsado de la línea durante la prueba. Se mantiene esta presión por un periodo determi-
operación de llenado, antes de iniciar la prueba de presión. nado de tiempo. El ajuste en volumen de agua necesario
Se recomienda instalar válvulas automáticas de expulsión para mantener esa presión debe estar dentro de los
de aire o ventosas en los puntos altos del tramo a probar. valores permitidos por la ecuación siguiente:
La presencia de aire en la línea durante la prueba puede
causar presiones excesivas debido a su compresión por el
agua causando fallas a la tubería o dar errores en la
prueba.

33
6. Dejar pasar otras 24 horas y tomar otra muestra
Fórmula:
haciendo el mismo ensayo.
(N * D * P0.5)
L = 7. Si los resultados son satisfactorios, debe evacuarse el
7400 agua de la desinfección y proceder a hacer la conexión
definitiva
Donde:
L: Permisibilidad de la prueba, gal/hr Rotulado
N: Número de uniones en el tramo, de Tubería y Accesorios
D: Diámetro nominal de la Tubería, pulgadas
P: Presión promedio de la prueba, psi
Marca y uso BIAXIAL de PAVCO
Uso Presión Agua Potable
País de origen y fabricante PAVCO COLOMBIA
El propósito de esta prueba es verificar que no haya fugas Material PVCO 1135 ó PVCO 1125
en las uniones, conexiones a accesorios y otros elementos Norma de fabricación ASTM F1483 ó NTC 5425
del tramo a probar. Diámetro nominal Por Ejemplo IPS 4” (114mm)
Presión de Trabajo Por ejemplo PR 200 psi (1.38 mPa)
La presión de trabajo del tramo puede ser la presión de Código de Trazabilidad Planta Año
prueba. Se mantiene esta presión por un periodo determi- 1 digito 2 digitos
nado de tiempo. El ajuste en volumen de agua necesario Mes Día
para mantener esa presión debe estar dentro de los valores 2 digitos 2 digitos
Turno No.Máquina
permitidos por la ecuación siguiente: 2 digitos 2 digitos
Lote RT Por ejemplo 001
Limpiezan y Desinfección:
1. Inyectar agua al tramo de tubería a desinfectar, mante-
niendo destapada la salida. Dejar drenar para lavar la
tubería.

2. Calcular el volumen de agua necesaria para llenar el


tramo de tubería a desinfectar y determinar la cantidad
de desinfectante a inyectar de tal forma que se garan-
tice una concentración de 50mg/l de Cloro.

3. Inyectar agua potable al tramo a desinfectar, permitien-


do que salga por el extremo de salida por unos minutos.
Inyectar el desinfectante, bien sea con Cloro líquido o
Hipoclorito de Sodio que garantice una concentración
de 50mg/l. Este puede diluirse previamente en el agua
de llenado o inyectarse separadamente. Dejar salir
unos minutos más y taponar la salida y entrada, cuando
se garantice la concentración de 50mg/l.

4. Dejar en reposo 24 horas, tiempo en el cual la concen-


tración de Cloro debe estar, mínimo en 25mg/l. Si está
por debajo de este valor, debe agregarse más desinfec-
tante.

5. Tomar una muestra de agua de la tubería en proceso


de desinfección. Al analizarla en un laboratorio califica-
do para este fin, debe estar libre de microorganismos
coliformes.

34
Anexo

35
Los datos de esta tabla no deben tomarse como definitivos. Son únicamente para dar una idea aproximada. En caso de deuda
comuniquese con la oficina de servicio al cliente.
36
Encuéntranos en: @pavcowavin.pe

www.pavcowavin.com.pe

MEXICHEM PERU S.A. Todos los derechos reservados.