rewranna
Printer Frlenay View
PRO 2008 GMC Sierra 5.3L Eng 1500
DTC B0228, B0413, B0423, Or B3779
Diagnostic Instructions
+ Perform the Diagnostic System Check - Vehicle prior to using this diagnostic
procedure.
+ Review Strategy Based Diagnosis for an overview of the diagnostic approach.
+ Diagnostic Procedure Instructions provides an overview of each diagnostic category.
DTC Descriptor
DTC B0228 02
Recirculate Position Feedback Circuit Short to Ground
DTC B0228 05
Recirculate Position Feedback Circuit Short to Battery or Open
DTC B0228 61
Recirculate Position Circuit Actuator Stuck
DTC B0413 02
Temperature Control 1 Feedback Circuit Short to Ground
DTC B0413 05
Temperature Control 1 Feedback Circuit Short to Battery or Open
DTC B0413 61
Temperature Control 1 Feedback Circuit Actuator Stuck Open
DTC B0423 02
Temperature Control 2 Feedback Circuit Short to Ground
DTC B0423 05
Temperature Control 2 Feedback Circuit Short to Battery or Open
DTC B0423 61
Temperature Control 2 Circuit Actuator Stuck
DTC 83779 02
Air Flow Control 9 Feedback Circuit Short to Ground
hapihwwe2 prodemandcomPrinuindedeontent=atiloBimodulo=flgebiab=falsoBter=faleo8yre=lasefclassNamo= Werewranna
DTC B3779 05
Printer Frlenay View
Air Flow Control 9 Feedback Circuit Short to Battery or Open
DTC B3779 61
Air Flow Control 9 Circuit Actuator Stuck
Circuit
Recirculation Door
Ignition
Recirculation 5-Volt
Reference
Recirculation Door
Position Signal
Recirculation Door
Control
Recirculation Low
Reference
Driver Air
Temperature Door
Ignition
Driver Air
Temperature 5-Volt
Reference
Driver Air
Temperature Door
Position Signal
Driver Air
Temperature Door
Control
Driver Air
Temperature Low
Reference
Passenger Air
Temperature Door
hhapihuved protean comPrinuindedeonter
Fault Information
Short to Ground
B0228 02
B0228 02, B0413
02, B0423 02 or
B3779 02
B0228 02
B0228 02
B0228 02
B0413 02
B0228 02, B0413
02, B0423 02 or
B3779 02
B0413 02
B0413 02
B0413 02
B0423 02
iclobmodle=talsesiab=falsoster
OpentHigh
Resistance
B0228 05
B0228 05
B0228 05
B0228 05
B0228 05
B0413 05
B0413 05
B0413 05
B0413 05
B0413 05
B0423 05
Signal
Short to Voltage Performance
B0228 05 B0228 61
B0228 02,
B0413 02,
B0423 02 or 80228 61
B3779 02
B0228 05 B0228 61
B0228 05 B0228 61
B0228 05 B0228 61
B0413 05 B0413 61
B0228 02,
B0413 02,
B0423 02 or 50413 61
B3779 02
B0413 05 B0413 61
B0413 05 B0413 61
B0413 05 B0413 61
B0423 05 B0423 61
Isodyrms=falsedclassName=
26rewranna Printer Friensty View
Ignition
Passenger Air B0228 02, B0413 Boag nd
Temperature 5-Volt 02,B0423.02 or 80423 05 2 0423 61
Reference B3779 02 80423 02 or
83779 02
Passenger Air
Temperature Door 80423 02 80423 05 B0423 05 B0423 61
Position Signal
Passenger Air
Temperature Door 80423 02 80423 05 B0423 05 B0423 61
Control
Passenger Air
Temperature Low 80423 02 8042305 80423 05 80423 61
Reference
Mode Door Ignition 83779 02 8377905 ——_B377905 83779 61
80228 02,
0228 02, B0413 7
Mode 5-Volt 02, 8042302 0r 8377905 80413 02, 83779 61
Reference 3779 02 80423 02 or
83779 02
Mode Door Position 83779 02 83779 05 83779 05 83779 61
Signal
Mode Door Control 83779 02 8377905 ——_B377905 83779 61
Mode Low 83779 02 83779 05 83779 05 83779 61
Reference
uuit/System Description
The HVAC control module controls the HVAC door actuators to regulate the airflow through the
HVAC system. Each actuator consists of an electric motor and a potentiometer. The module
supplies a lowreference and 5-volt reference source voltage to the potentiometer. The HVAC
control module monitors the voltage drop across the potentiometer on the door position signal
circuit. When the actuator shaft rotates, the voltage on the door position signal circuit changes.
The control circuit uses either a 0, 2.5 or 5-volt signal to command the actuator movement.
When the actuator is at rest, the control circuit value is 2.5 volts. A 0 or 5-volt control signal
commands the actuator movement in opposite directions.
+ 80228 is for the recirculate actuator.
+ 80413 is for the drivers air temperature actuator.
+ 80428 is for the passenger air temperature actuator.
+ 83779 is for the mode actuator.
Conditions For Running The DTC
hhapihuved protean comPrinuindedeonter
iclobmodle=talsesiab=falsoster
Isodyrms=falsedclassName=rewranna
Pricer Fenty View
+ Ignition ON.
+ The HVAC module is ON.
Conditions For Setting The DTC
The actual door position differs from the commanded door position by more than 4 counts or the
HVAC control module detects the door position signal circuit is less than 3 counts or greater
than 253 counts.
Action Taken When The DTC Sets
The control circuit is deactivated for the appropriate actuator.
Conditions For Clearing The DTC
+ The DTC becomes history when the HVAC control module no longer detects the
condition that set the DTC.
+ The history DTC will clear after 100 fault-free ignition cycles.
Reference Information
Schematic Reference
HVAC Schematics
Connector End View Reference
Component Connector End Views
Description and Operation
+ Air Delivery Description and Operation
+ Air Temperature Description and Operation
Electrical Information Reference
+ Circuit Testing
+ Connector Repairs
+ Testing for Intermittent Conditions and Poor Connections
+ Wiring Repairs
Scan Tool Reference
Control Module References for scan tool information
Circuit/System Verification
Ignition ON, command the appropriate actuator in both directions with a scan tool. The scan tool
door position parameter reading should be between 3 and 253 counts
hapihwwe2 prodemandcomPrinuindedeontent=atiloBimodulo=flgebiab=falsoBter=faleo8yre=lasefclassNamo=revo Pricer Fenty View
Circuit/System Testing
1. Ignition OFF, disconnect the harness connector at the appropriate actuator.
2. Test for less than 1 ohm between the lowreference circuit terminal 7 and ground.
1. If greater than the specified range, test the low reference circuit for an open/high
resistance. If the circuit tests normal, replace the HVAC control module.
3. Ignition ON, test for 4.8-5.2 volts between the 5-volt reference circuit terminal 10 and
ground.
1. Ifless than the specified range, test the 5-volt reference circuit for a short to
ground or an open/high resistance. If the circuit tests normal, replace the HVAC
control module.
2. If greater than the specified range, test the 5-volt reference circuit for a short to
voltage. If the circuit tests normal, replace the HVAC control module.
4. Verify the appropriate scan tool parameter is less than 4 counts
1. If greater than the specified range, test the signal circuit terminal 9 for a short to
ground. If the circuit tests normal, replace the HVAC control module.
5. Install a 3-amp fused jumper wire between the signal circuit terminal 9 and the low
reference circuit terminal. Verify the appropriate scan tool parameter is greater than
250 counts.
1. Ifless than the specified range, test the signal circuit for a short to voltage or an
‘openthigh resistance. ff the circuit tests normal, replace the HVAC control
module.
6. Ignition ON, verify that a test lamp illuminates between the ignition circuit terminal 5 and
ground.
1. Ifthe test lamp does not illuminate, test the ignition circuit for a short to ground
or an openthigh resistance.
7. Install a DMM between the actuator control circuit terminal 6 and ground. While
monitoring the DMM, use the scan tool to command the appropriate actuator from one
direction to the other. The voltage on the control circuit should move from 0 volts in
one direction to 5 volts in the other direction and 2.5 volts in the at rest state.
1. Ifthe voltage does not change, test the control circuit for an open, short to
voltage or short to ground. If circuit tests normal replace the HVAC control
module.
8. Fall circuits test normal, replace the actuator.
Repair Procedures
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
+ Recirculation Actuator Replacement
hapihwwe2 prodemandcomPrinuindedeontent=atiloBimodulo=flgebiab=falsoBter=faleo8yre=lasefclassNamo=evans Printer Friensty View
+ Mode Actuator Replacement
+ Air Temperature Actuator Replacement - Right Side
+ Air Temperature Actuator Replacement - Left Side
hapihwwe2 prodemandcomPrinuindedeontent=atiloBimodulo=flgebiab=falsoBter=faleo8yre=lasefclassNamo=