Jump to content

Squeezed states of light

From Wikipedia, the free encyclopedia

In quantum physics, light is in a squeezed state[1] if its electric field strength Ԑ for some phases has a quantum uncertainty smaller than that of a coherent state. The term squeezing thus refers to a reduced quantum uncertainty. To obey Heisenberg's uncertainty relation, a squeezed state must also have phases at which the electric field uncertainty is anti-squeezed, i.e. larger than that of a coherent state. Since 2019, the gravitational-wave observatories LIGO and Virgo employ squeezed laser light, which has significantly increased the rate of observed gravitational-wave events.[2][3][4]

Quantum physical background

[edit]

An oscillating physical quantity cannot have precisely defined values at all phases of the oscillation. This is true for the electric and magnetic fields of an electromagnetic wave, as well as for any other wave or oscillation (see figure right). This fact can be observed in experiments and is described by quantum theory. For electromagnetic waves usually just the electric field is considered, because it is the one that mainly interacts with matter.

Fig. 1. shows five different quantum states that a monochromatic wave could be in. The difference of the five quantum states is given by different electric field excitations and by different distributions of the quantum uncertainty along the phase . For a displaced coherent state, the expectation (mean) value of the electric field shows an oscillation, with an uncertainty independent of the phase (a). Also the phase- (b) and amplitude-squeezed states (c) show an oscillation of the mean electric field, but here the uncertainty depends on phase and is squeezed for some phases. The vacuum state (d) is a special coherent state and is not squeezed. It has zero mean electric field for all phases and a phase-independent uncertainty. It has zero energy on average, i.e. zero photons, and is the ground state of the monochromatic wave we consider. Finally, a squeezed vacuum state has also a zero mean electric field but a phase-dependent uncertainty (e).

Generally, quantum uncertainty reveals itself through a large number of identical measurements on identical quantum objects (here: modes of light) that, however, give different results. Let us again consider a continuous-wave monochromatic light wave (as emitted by an ultra-stable laser). A single measurement of Ԑ is performed over many periods of the light wave and provides a single number. The next measurements of Ԑ will be done consecutively on the same laser beam. Having recorded a large number of such measurements we know the field uncertainty at . In order to get the full picture, and for instance Fig.1(b), we need to record the statistics at many different phases .

Quantitative description of (squeezed) uncertainty

[edit]

The measured electric field strengths at the wave's phase are the eigenvalues of the normalized quadrature operator , defined as[5] where and are the annihilation and creation operators, respectively, of the oscillator representing the photon. is the wave's amplitude quadrature, equivalent to the position in optical phase space, and is the wave's phase quadrature, equivalent to momentum. and are non-commuting observables. Although they represent electric fields, they are dimensionless and satisfy the following uncertainty relation:[6]

,

where stands for the variance. (The variance is the mean of the squares of the measuring values minus the square of the mean of the measuring values.) If a mode of light is in its ground state (having an average photon number of zero), the uncertainty relation above is saturated and the variances of the quadrature are . (Other normalizations can also be found in literature. The normalization chosen here has the nice property that the sum of the ground state variances directly provide the zero point excitation of the quantized harmonic oscillator ).

Definition: Light is in a squeezed state, if (and only if) a phase exists for which .[6][7]

While coherent states belong to the semi-classical states, since they can be fully described by a semi-classical model,[8] squeezed states of light belong to the so-called nonclassical states, which also include number states (Fock states) and Schrödinger cat states.

Squeezed states (of light) were first produced in the mid-1980s.[9][10] At that time, quantum noise squeezing by up to a factor of about 2 (3 dB) in variance was achieved, i.e. . Today, squeeze factors larger than 10 (10 dB) have been directly observed.[11][12][13] A limitation is set by decoherence, mainly in terms of optical loss.[8]

The squeeze factor in Decibel (dB) can be computed in the following way:

, where is the smallest variance when varying the phase from 0 to . This particular phase is called the squeeze angle.

Representation of squeezed states by quasi-probability densities

[edit]
Fig. 1(f): Left: Wigner function of a squeezed vacuum state. Right: Connection to Fig. 1 (e).

Quantum states such as those in Fig. 1 (a) to (e) are often displayed as Wigner functions, which are quasi-probability density distributions. Two orthogonal quadratures, usually and , span a phase space diagram, and the third axes provides the quasi probability of yielding a certain combination of . Since and are not precisely defined simultaneously, we cannot talk about a 'probability' as we do in classical physics but call it a 'quasi probability'. A Wigner function is reconstructed from time series of and . The reconstruction is also called 'quantum tomographic reconstruction'. For squeezed states, the Wigner function has a Gaussian shape, with an elliptical contour line, see Fig.: 1(f).

Physical meaning of measurement quantity and measurement object

[edit]

Quantum uncertainty becomes visible when identical measurements of the same quantity (observable) on identical objects (here: modes of light) give different results (eigen values). In case of a single freely propagating monochromatic laser beam, the individual measurements are performed on consecutive time intervals of identical length. One interval must last much longer than the light's period; otherwise the monochromatic property would be significantly disturbed. Such consecutive measurements correspond to a time series of fluctuating eigen values. Consider an example in which the amplitude quadrature was repeatedly measured. The time series can be used for a quantum statistical characterization of the modes of light. Obviously, the amplitude of the light wave might be different before and after our measurement, i.e. the time series does not provide any information about very slow changes of the amplitude, which corresponds to very low frequencies. This is a trivial but also fundamental issue, since any data taking lasts for a finite time. Our time series, however, does provide meaningful information about fast changes of the light's amplitude, i.e. changes at frequencies higher than the inverse of the full measuring time. Changes that are faster than the duration of a single measurement, however, are invisible again. A quantum statistical characterization through consecutive measurements on some sort of a carrier is thus always related to a specific frequency interval, for instance described by with Based on this insight, we can describe the physical meaning of the observable more clearly:[8]

Fig. 2: Normalized variances of modulation states of the same carrier light beam versus modulation frequency . Here, the measurement band width is about 10 kHz. Each trace therefore describes about 200 mutually independent modulation modes.

The quantum statistical characterization using identical consecutive modes carried by a laser beam confers to the laser beam's electric field modulation within a frequency interval. The actual observable needs to be labeled accordingly, for instance as . is the amplitude (or depth) of the amplitude modulation and the amplitude (or depth) of the phase modulation in the respective frequency interval. This leads to the doggerel expressions 'amplitude quadrature amplitude' and 'phase quadrature amplitude'.

Within some limitations, for instance set by the speed of the electronics, and can be freely chosen in course of data acquisition and, in particular, data processing. This choice also defines the measurement object, i.e. the mode that is characterized by the statistics of the eigen values of and . The measurement object thus is a modulation mode that is carried by the light beam. – In many experiments, one is interested in a continuous spectrum of many modulation modes carried by the same light beam.[14] Fig. 2 shows the squeeze factors of many neighboring modulation modes versus . The upper trace refers to the uncertainties of the same modes being in their vacuum states, which serves as the 0 dB reference.

The observables in squeezed light experiments correspond exactly to those being used in optical communication. Amplitude modulation (AM) and frequency modulation (FM) are the classical means to imprint information on a carrier field. (Frequency modulation is mathematically closely related to phase modulation). The observables and also correspond to the measurement quantities in laser interferometers, such as in Sagnac interferometers measuring rotation changes and in Michelson interferometers observing gravitational waves. Squeezed states of light thus have ample applications in optical communication and optical measurements. The most prominent and important application is in gravitational-wave observatories.[15][16][8] Arguably, it is the first end-user driven application of quantum correlations.[17] Squeezed light originally was not planned to be implemented in either Advanced LIGO nor in Advanced Virgo, but now it contributes a significant factor towards the observatories design sensitivities and increases the rate of observed gravitational-wave events.[2][3]

Frequency-dependent squeezing

[edit]
Strain noise spectra of the LIGO (Hanford) detector in amplitude spectral density units for frequency-dependent squeezing (purple), frequency-independent squeezing (green) and no squeezing (black)[18][19]

Frequency-dependent squeezing is a method being implemented at the LIGO–Virgo–KAGRA collaboration to improve sensitivity using its 300 m long filter cavities to handle light differently according to frequencies which allows to improve accuracy of phases at high frequencies at the cost of more inaccuracy in amplitudes at low frequencies and equivalently better amplitudes at low frequencies but worse phases at high frequencies, manipulating the uncertainty relation by the measurement of interest.[20][21]

Noise at high frequencies is dominated by shot noise while at low frequencies is dominated by radiation pressure noise so when one source is reduced the other increases.[22]

Applications

[edit]

Optical high-precision measurements

[edit]
Fig. 3: Schematic of a laser interferometer for the detection of gravitational waves. Here, squeezed vacuum states are injected and overlapped with the bright field at the central beam splitter to improve the sensitivity.
Fig. 4: Photo voltages of a photo diode detecting light.

Squeezed light is used to reduce the photon counting noise (shot noise) in optical high-precision measurements, most notably in laser interferometers. There are a large number of proof-of-principle experiments.[23][24] Laser interferometers split a laser beam in two paths and overlap them again afterwards. If the relative optical path length changes, the interference changes, and the light power in the interferometer's output port as well. This light power is detected with a photo diode providing a continuous voltage signal. If for instance the position of one interferometer mirror vibrates and thereby causes an oscillating path length difference, the output light has an amplitude modulation of the same frequency. Independent of the existence of such a (classical) signal, a beam of light always carries at least the vacuum state uncertainty (see above). The (modulation) signal with respect to this uncertainty can be improved by using a higher light power inside the interferometer arms, since the signal increases with the light power. This is the reason (in fact the only one) why Michelson interferometers for the detection of gravitational waves use very high optical power. High light power, however, produces technical problems. Mirror surfaces absorb parts of the light, become warmer, get thermally deformed and reduce the interferometer's interference contrast. Furthermore, an excessive light power can excite unstable mechanical vibrations of the mirrors. These consequences are mitigated if squeezed states of light are used for improving the signal-to-noise-ratio. Squeezed states of light do not increase the light's power. They also do not increase the signal, but instead reduce the noise.[8]

Laser interferometers are usually operated with monochromatic continuous-wave light. The optimal signal-to-noise-ratio is achieved by either operating the differential interferometer arm lengths such that both output ports contain half of the input light power (half fringe) and by recording the difference signal from both ports, or by operating the interferometer close to a dark fringe for one of the output ports where just a single photodiode is placed.[7] The latter operation point is used in gravitational-wave (GW) detectors.

For improving an interferometer sensitivity with squeezed states of light, the already existing bright light does not need to be fully replaced. What has to be replaced is just the vacuum uncertainty in the difference of the phase quadrature amplitudes of the light fields in the arms, and only at modulation frequencies at which signals are expected. This is achieved by injecting a (broadband) squeezed vacuum field (Fig. 1e) into the unused interferometer input port (Fig. 3). Ideally, perfect interference with the bright field is achieved. For this the squeezed field has to be in the same mode as the bright light, i.e. has to have the same wavelength, same polarisation, same wavefront curvature, same beam radius, and, of course, the same directions of propagation in the interferometer arms. For the squeezed-light enhancement of a Michelson interferometer operated at dark fringe, a polarising beam splitter in combination with a Faraday rotator is required. This combination constitutes an optical diode. Without any loss, the squeezed field is overlapped with the bright field at the interferometer's central beam splitter, is split and travels along the arms, is retro-reflected, constructively interferes and overlaps with the interferometer signal towards the photo diode. Due to the polarisation rotation of the Faraday rotator, the optical loss on signal and squeezed field is zero (in the ideal case). Generally, the purpose of an interferometer is to transform a differential phase modulation (of two light beams) into an amplitude modulation of the output light . Accordingly, the injected vacuum-squeezed field is injected such that the differential phase quadrature uncertainty in the arms is squeezed. On the output light amplitude quadrature squeezing is observed. Fig. 4 shows the photo voltage of the photo diode in the interferometer output port. Subtracting the constant offset provides the (GW) signal.

A source of squeezed states of light were integrated in the gravitational-wave detector GEO600 in 2010,[16] as shown in Fig. 4. The source was built by the research group of R. Schnabel at Leibniz Universität Hannover (Germany).[25] With squeezed light, the sensitivity of GEO600 during observational runs has been increased to values, which for practical reasons were not achievable without squeezed light.[26] In 2018, squeezed light upgrades are also planned for the gravitational wave detectors Advanced LIGO and Advanced Virgo.

Going beyond squeezing of photon counting noise, squeezed states of light can also be used to correlate quantum measurement noise (shot noise) and quantum back action noise to achieve sensitivities in the quantum non-demolition (QND) regime.[27][28]

Radiometry and calibration of quantum efficiencies

[edit]

Squeezed light can be used in radiometry to calibrate the quantum efficiency of photo-electric photo detectors without a lamp of calibrated radiance.[12] Here, the term photo detector refers to a device that measures the power of a bright beam, typically in the range from a few microwatts up to about 0.1 W. The typical example is a PIN photo diode. In case of perfect quantum efficiency (100%), such a detector is supposed to convert every photon energy of incident light into exactly one photo electron. Conventional techniques of measuring quantum efficiencies require the knowledge of how many photons hit the surface of the photo detector, i.e. they require a lamp of calibrated radiance. The calibration on the basis of squeezed states of light uses instead the effect, that the uncertainty product increases the smaller the quantum uncertainty of the detector is. In other words: The squeezed light method uses the fact that squeezed states of light are sensitive against decoherence. Without any decoherence during generation, propagation and detection of squeezed light, the uncertainty product has its minimum value of 1/16 (see above). If optical loss is the dominating decoherence effect, which usually is the case, the independent measurement of all optical losses during generation and propagation together with the value of the uncertainty product directly reveals the quantum uncertainty of the photo detectors used.[12]

When a squeezed state with squeezed variance is detected with a photo detector of quantum efficiency (with ), the actually observed variance is increased to Optical loss mixes a portion of the vacuum state variance to the squeezed variance, which decreases the squeeze factor. The same equation also describes the influence of a non-perfect quantum efficiency on the anti-squeezed variance. The anti-squeezed variance reduces, however, the uncertainty product increases. Optical loss on a pure squeezed state produces a mixed squeezed state.

Entanglement-based quantum key distribution

[edit]
Fig. 5: Measurement results on two EPR entangled light fields. The measurement values taken on one subsystem (at A) and on the other subsystem (at B) vary a lot, i.e. show a large local uncertainty. Comparing the data as shown here reveals correlations (top, blue) or anti-correlations (bottom, blue). In this example, correlations as well as anti-correlations are stronger than the vacuum state uncertainty (black).

Squeezed states of light can be used to produce Einstein-Podolsky-Rosen-entangled light that is the resource for a high quality level of quantum key distribution (QKD), which is called 'one-sided device independent QKD'.[29]

Superimposing on a balanced beam splitter two identical light beams that carry squeezed modulation states and have a propagation length difference of a quarter of their wavelength produces two EPR entangled light beams at the beam splitter output ports. Quadrature amplitude measurements on the individual beams reveal uncertainties that are much larger than those of the ground states, but the data from the two beams show strong correlations: from a measurement value taken at the first beam (), one can infer the corresponding measurement value taken at the second beam (). If the inference shows an uncertainty smaller than that of the vacuum state, EPR correlations exist, see Fig. 5.

The aim of quantum key distribution is the distribution of identical, true random numbers to two distant parties A and B in such a way that A and B can quantify the amount of information about the numbers that has been lost to the environment (and thus is potentially in hand of an eavesdropper). To do so, sender (A) sends one of the entangled light beams to receiver (B). A and B measure repeatedly and simultaneously (taking the different propagation times into account) one of two orthogonal quadrature amplitudes. For every single measurement they need to choose whether to measure or in a truly random way, independently from each other. By chance, they measure the same quadrature in 50% of the single measurements. After having performed a large number of measurements, A and B communicate (publicly) what their choice was for every measurement. The non-matched pairs are discarded. From the remaining data they make public a small but statistically significant amount to test whether B is able to precisely infer the measurement results at A. Knowing the characteristics of the entangled light source and the quality of the measurement at the sender site, the sender gets information about the decoherence that happened during channel transmission and during the measurement at B. The decoherence quantifies the amount of information that was lost to the environment. If the amount of lost information is not too high and the data string not too short, data post processing in terms of error correction and privacy amplification produces a key with an arbitrarily reduced epsilon-level of insecurity. In addition to conventional QKD, the test for EPR correlations not only characterizes the channel over which the light was sent (for instance a glas fibre) but also the measurement at the receiver site. The sender does not need to trust the receivers measurement any more. This higher quality of QKD is called one-sided device independent. This type of QKD works if the natural decoherence is not too high. For this reason, an implementation that uses conventional telecommunication glas fibers would be limited to a distance of a few kilometers.[29]

Generation

[edit]
Fig. 6: Schematic of a squeezing resonator. The pumped nonlinear crystal inside the resonator attenuates the electric field at optical frequency . This leads to perfect destructive interference for one quadrature angle that is carried by the optical frequency and propagates towards the left (left side of resonator). The pump light enters from the right and is simply retro-reflected. If the pump light intensity is kept below the resonator's oscillation threshold, its input and output powers are basically identical.
Timeline of experimentally achieved light squeezing values in the laboratory. Since the first demonstration in 1985 values have steadily improved.

Squeezed light is produced by means of nonlinear optics. The most successful method uses degenerate type I optical-parametric down-conversion (also called optical-parametric amplification) inside an optical resonator. To squeeze modulation states with respect to a carrier field at optical frequency , a bright pump field at twice the optical frequency is focussed into a nonlinear crystal that is placed between two or more mirrors forming an optical resonator. It is not necessary to inject light at frequency . (Such light, however, is required for detecting the (squeezed) modulation states). The crystal material needs to have a nonlinear susceptibility and needs to be highly transparent for both optical frequencies used. Typical materials are lithium niobate (LiNbO3) and (periodically poled) potassium titanyl phosphate (KTP). Due to the nonlinear susceptibility of the pumped crystal material, the electric field at frequency is amplified and deamplified, depending on the relative phase to the pump light. At the pump's electric field maxima, the electric field at frequency is amplified. At the pump's electric field minima, the electric field at frequency is squeezed. This way, the vacuum state (Fig. 1e) is transferred to a squeezed vacuum state (Fig. 1d). A displaced coherent state (Fig. 1a) is transferred to a phase squeezed state (Fig. 1b) or to an amplitude squeezed state (Fig. 1c), depending on the relative phase between coherent input field and pump field. A graphical description of these processes can be found in.[8]

The existence of a resonator for the field at is essential. The task of the resonator is shown in Fig. 6. The left resonator mirror has a typical reflectivity of about . Correspondingly of the electric field that (continuously) enters from the left gets reflected. The remaining part is transmitted and resonates between the two mirrors. Due to the resonance, the electric field inside the resonator gets enhanced (even without any medium inside). of the steady-state light power inside the resonator gets transmitted towards the left and interferes with the beam that was retro-reflected directly. For an empty loss-less resonator, 100% of the light power would eventually propagate towards the left, obeying energy conservation.

The principle of the squeezing resonator is the following: The medium parametrically attenuates the electric field inside the resonator to such a value that perfect destructive interference is achieved outside the resonator for the attenuated field quadrature. The optimum field attenuation factor inside the resonator is slightly below 2, depending on the reflectivity of the resonator mirror.[8] This principle also works for electric field uncertainties. Inside the resonator, the squeeze factor is always less than 6 dB, but outside the resonator it can be arbitrarily high. If quadrature is squeezed, quadrature is anti-squeezed – inside as well as outside the resonator. It can be shown that the highest squeeze factor for one quadrature is achieved if the resonator is at its threshold for the orthogonal quadrature. At threshold and above, the pump field is converted into a bright field at optical frequency . Squeezing resonators are usually operated slightly below threshold, for instance, to avoid damage to the photo diodes due to the bright down-converted field.

A squeezing resonator works efficiently at modulation frequencies well inside its linewidth. Only for these frequencies highest squeeze factors can be achieved. At frequencies the optical-parametric gain is strongest, and the time delay between the interfering parts negligible. If decoherence was zero, infinite squeeze factors could be achieved outside the resonator, although the squeeze factor inside the resonator was less than 6 dB. Squeezing resonators have typical linewidths of a few tens of MHz up to GHz.[30]

Due to the interest in the interaction between squeezed light and atomic ensemble, narrowband atomic resonance squeezed light have been also generated through crystal[31] and the atomic medium.[32]

Detection

[edit]
Fig. 7: Balanced homodyne detector. LO: local oscillator; PD: photo diode.

Squeezed states of light can be fully characterized by a photo-electric detector that is able to (subsequently) measure the electric field strengths at any phase . (The restriction to a certain band of modulation frequencies happens after the detection by electronic filtering.) The required detector is a balanced homodyne detector (BHD). It has two input ports for two light beams. One for the (squeezed) signal field, and another for the BHDs local oscillator (LO) having the same wavelength as the signal field. The LO is part of the BHD. Its purpose is to beat with the signal field and to optically amplify it. Further components of the BHD are a balanced beam splitter and two photo diodes (of high quantum efficiency). Signal beam and LO need to be overlapped at the beam splitter. The two interference results in the beam splitter output ports are detected and the difference signal recorded (Fig. 7). The LO needs to be much more intense than the signal field. In this case the differential signal from the photo diodes in the interval is proportional to the quadrature amplitude . Changing the differential propagation length before the beam splitter sets the quadrature angle to an arbitrary value. (A change by a quarter of the optical wavelength changes the phase by  .)

The following should be stated at this point: Any information about the electro-magnetic wave can only be gathered in a quantized way, i.e. by absorbing light quanta (photons). This is also true for the BHD. However, a BHD cannot resolve the discrete energy transfer from the light to the electric current, since in any small time interval a vast number of photons are detected. This is ensured by the intense LO. The observable therefore has a quasi-continuous eigenvalue spectrum, as it is expected for an electric field strength. (In principle, one can also characterize squeezed states, in particular squeezed vacuum states, by counting photons, however, in general the measurement of the photon number statistic is not sufficient for a full characterization of a squeezed state and the full density matrix in the basis of the number states has to be determined.)

See also

[edit]

References

[edit]
  1. ^ Walls, D. F. (1983). "Squeezed states of light". Nature. 306 (5939): 141–146. Bibcode:1983Natur.306..141W. doi:10.1038/306141a0. ISSN 1476-4687. S2CID 4325386.
  2. ^ a b Tse, M.; Yu, Haocun; Kijbunchoo, N.; Fernandez-Galiana, A.; Dupej, P.; Barsotti, L.; Blair, C. D.; Brown, D. D.; Dwyer, S. E.; Effler, A.; Evans, M. (December 5, 2019). "Quantum-Enhanced Advanced LIGO Detectors in the Era of Gravitational-Wave Astronomy". Physical Review Letters. 123 (23): 231107. Bibcode:2019PhRvL.123w1107T. doi:10.1103/physrevlett.123.231107. hdl:1721.1/136579.2. ISSN 0031-9007. PMID 31868462.
  3. ^ a b Acernese, F.; Agathos, M.; Aiello, L.; Allocca, A.; Amato, A.; Ansoldi, S.; Antier, S.; Arène, M.; Arnaud, N.; Ascenzi, S.; Astone, P. (December 5, 2019). "Increasing the Astrophysical Reach of the Advanced Virgo Detector via the Application of Squeezed Vacuum States of Light". Physical Review Letters. 123 (23): 231108. Bibcode:2019PhRvL.123w1108A. doi:10.1103/physrevlett.123.231108. hdl:11573/1343006. ISSN 0031-9007. PMID 31868444.
  4. ^ Abbott, R. (2021). "GWTC-2: Compact Binary Coalescences Observed by LIGO and Virgo during the First Half of the Third Observing Run". Physical Review X. 11 (2): 021053. arXiv:2010.14527. Bibcode:2021PhRvX..11b1053A. doi:10.1103/PhysRevX.11.021053. S2CID 225094244.
  5. ^ Schleich, Wolfgang P. (2001). Quantum Optics in Phase Space (1 ed.). Berlin: WILEY-VCH Verlag Berlin GmbH. ISBN 3-527-29435-X.
  6. ^ a b Gerry, Christopher; Knight, Peter (2004). Introductory Quantum Optics. Cambridge University Press. doi:10.1017/cbo9780511791239. ISBN 9780521527354. S2CID 209908717.
  7. ^ a b Bachor, Hans-Albert; Ralph, Tim C. (2004). A Guide to Experiments in Quantum Optics, Second Edition - Wiley Online Library. doi:10.1002/9783527619238. ISBN 9783527619238. S2CID 118649942.
  8. ^ a b c d e f g Schnabel, Roman (2017). "Squeezed states of light and their applications in laser interferometers". Physics Reports. 684: 1–51. arXiv:1611.03986. Bibcode:2017PhR...684....1S. doi:10.1016/j.physrep.2017.04.001. S2CID 119098759.
  9. ^ R. E. Slusher et al., Observation of squeezed states generated by four wave mixing in an optical cavity, Phys. Rev. Lett. 55 (22), 2409 (1985)
  10. ^ Wu, Ling-An (1986). "Generation of Squeezed States by Parametric Down Conversion" (PDF). Physical Review Letters. 57 (20): 2520–2523. Bibcode:1986PhRvL..57.2520W. doi:10.1103/physrevlett.57.2520. PMID 10033788.
  11. ^ Vahlbruch, Henning; Mehmet, Moritz; Chelkowski, Simon; Hage, Boris; Franzen, Alexander; Lastzka, Nico; Goßler, Stefan; Danzmann, Karsten; Schnabel, Roman (January 23, 2008). "Observation of Squeezed Light with 10-dB Quantum-Noise Reduction". Physical Review Letters. 100 (3): 033602. arXiv:0706.1431. Bibcode:2008PhRvL.100c3602V. doi:10.1103/PhysRevLett.100.033602. PMID 18232978. S2CID 3938634.
  12. ^ a b c Vahlbruch, Henning; Mehmet, Moritz; Danzmann, Karsten; Schnabel, Roman (September 6, 2016). "Detection of 15 dB Squeezed States of Light and their Application for the Absolute Calibration of Photoelectric Quantum Efficiency". Physical Review Letters. 117 (11): 110801. arXiv:2411.07379. Bibcode:2016PhRvL.117k0801V. doi:10.1103/PhysRevLett.117.110801. hdl:11858/00-001M-0000-002B-87B5-3. PMID 27661673.
  13. ^ Schönbeck, Axel; Thies, Fabian; Schnabel, Roman (January 1, 2018). "13 dB squeezed vacuum states at 1550 nm from 12 mW external pump power at 775 nm". Optics Letters. 43 (1): 110–113. arXiv:2005.09891. Bibcode:2018OptL...43..110S. doi:10.1364/OL.43.000110. ISSN 1539-4794. PMID 29328207. S2CID 23252788.
  14. ^ G. Breitenbach, F. Illuminati, S. Schiller, J. Mlynek (October 15, 1998), "Broadband detection of squeezed vacuum: A spectrum of quantum states", Europhysics Letters (EPL) (in German), vol. 44, no. 2, pp. 192–197, arXiv:quant-ph/9901044, Bibcode:1998EL.....44..192B, doi:10.1209/epl/i1998-00456-2, ISSN 0295-5075, S2CID 13119216{{citation}}: CS1 maint: multiple names: authors list (link)
  15. ^ Caves, Carlton M. (April 15, 1981). "Quantum-mechanical noise in an interferometer". Physical Review D. 23 (8): 1693–1708. Bibcode:1981PhRvD..23.1693C. doi:10.1103/physrevd.23.1693. ISSN 0556-2821.
  16. ^ a b The LIGO Scientific Collaboration (2011). "A gravitational wave observatory operating beyond the quantum shot-noise limit". Nature Physics. 7 (12): 962–965. arXiv:1109.2295. Bibcode:2011NatPh...7..962L. doi:10.1038/nphys2083. ISSN 1745-2481. S2CID 209832912.
  17. ^ Schnabel, Roman (January 29, 2020). ""Quantum Weirdness" in Exploitation by the International Gravitational-Wave Observatory Network". Annalen der Physik. 532 (3): 1900508. arXiv:1909.13723. Bibcode:2020AnP...53200508S. doi:10.1002/andp.201900508. ISSN 0003-3804.
  18. ^ LIGO O4 Detector Collaboration; Ganapathy, D.; Jia, W.; Nakano, M.; Xu, V.; Aritomi, N.; Cullen, T.; Kijbunchoo, N.; Dwyer, S. E.; Mullavey, A.; McCuller, L.; Abbott, R.; Abouelfettouh, I.; Adhikari, R. X.; Ananyeva, A. (October 30, 2023). "Broadband Quantum Enhancement of the LIGO Detectors with Frequency-Dependent Squeezing". Physical Review X. 13 (4): 041021. Bibcode:2023PhRvX..13d1021G. doi:10.1103/PhysRevX.13.041021. hdl:2440/140376.{{cite journal}}: CS1 maint: numeric names: authors list (link)
  19. ^ "LIGO Surpasses the Quantum Limit". LIGO Lab | Caltech. Retrieved November 15, 2023.
  20. ^ Virgo Collaboration; Acernese, F.; Agathos, M.; Ain, A.; Albanesi, S.; Alléné, C.; Allocca, A.; Amato, A.; Amra, C.; Andia, M.; Andrade, T.; Andres, N.; Andrés-Carcasona, M.; Andrić, T.; Ansoldi, S. (July 25, 2023). "Frequency-Dependent Squeezed Vacuum Source for the Advanced Virgo Gravitational-Wave Detector". Physical Review Letters. 131 (4): 041403. Bibcode:2023PhRvL.131d1403A. doi:10.1103/PhysRevLett.131.041403. hdl:11568/1196710. PMID 37566847. S2CID 260185660.
  21. ^ Polini, E (August 1, 2021). "Broadband quantum noise reduction via frequency dependent squeezing for Advanced Virgo Plus". Physica Scripta. 96 (8): 084003. Bibcode:2021PhyS...96h4003P. doi:10.1088/1402-4896/abfef0. ISSN 0031-8949. S2CID 235285860.
  22. ^ Zhao, Yuhang; Aritomi, Naoki; Capocasa, Eleonora; Leonardi, Matteo; Eisenmann, Marc; Guo, Yuefan; Polini, Eleonora; Tomura, Akihiro; Arai, Koji; Aso, Yoichi; Huang, Yao-Chin; Lee, Ray-Kuang; Lück, Harald; Miyakawa, Osamu; Prat, Pierre (April 28, 2020). "Frequency-Dependent Squeezed Vacuum Source for Broadband Quantum Noise Reduction in Advanced Gravitational-Wave Detectors". Physical Review Letters. 124 (17): 171101. arXiv:2003.10672. Bibcode:2020PhRvL.124q1101Z. doi:10.1103/PhysRevLett.124.171101. PMID 32412296. S2CID 214623227.
  23. ^ Xiao, Min; Wu, Ling-An; Kimble, H. J. (July 20, 1987). "Precision measurement beyond the shot-noise limit" (PDF). Physical Review Letters. 59 (3): 278–281. Bibcode:1987PhRvL..59..278X. doi:10.1103/PhysRevLett.59.278. PMID 10035719. S2CID 120065263.
  24. ^ Grangier, P.; Slusher, R. E.; Yurke, B.; LaPorta, A. (November 9, 1987). "Squeezed-light-enhanced polarization interferometer". Physical Review Letters. 59 (19): 2153–2156. Bibcode:1987PhRvL..59.2153G. doi:10.1103/PhysRevLett.59.2153. PMID 10035438.
  25. ^ Vahlbruch, Henning; Khalaidovski, Alexander; Lastzka, Nico; Gräf, Christian; Danzmann, Karsten; Schnabel, Roman (2010). "The GEO 600 squeezed light source". Classical and Quantum Gravity. 27 (8): 084027. arXiv:1004.4975. Bibcode:2010CQGra..27h4027V. doi:10.1088/0264-9381/27/8/084027. S2CID 53991930.
  26. ^ Grote, H.; Danzmann, K.; Dooley, K. L.; Schnabel, R.; Slutsky, J.; Vahlbruch, H. (May 1, 2013). "First Long-Term Application of Squeezed States of Light in a Gravitational-Wave Observatory". Physical Review Letters. 110 (18): 181101. arXiv:1302.2188. Bibcode:2013PhRvL.110r1101G. doi:10.1103/PhysRevLett.110.181101. PMID 23683187. S2CID 3566080.
  27. ^ Jaekel, M. T.; Reynaud, S. (1990). "Quantum Limits in Interferometric Measurements". EPL (Europhysics Letters). 13 (4): 301–306. arXiv:quant-ph/0101104. Bibcode:1990EL.....13..301J. doi:10.1209/0295-5075/13/4/003. ISSN 0295-5075. S2CID 119056243.
  28. ^ Kimble, H. J.; Levin, Yuri; Matsko, Andrey B.; Thorne, Kip S.; Vyatchanin, Sergey P. (December 26, 2001). "Conversion of conventional gravitational-wave interferometers into quantum nondemolition interferometers by modifying their input and/or output optics". Physical Review D. 65 (2): 022002. arXiv:gr-qc/0008026. Bibcode:2001PhRvD..65b2002K. doi:10.1103/PhysRevD.65.022002. S2CID 15339393.
  29. ^ a b Gehring, Tobias; Händchen, Vitus; Duhme, Jörg; Furrer, Fabian; Franz, Torsten; Pacher, Christoph; Werner, Reinhard F.; Schnabel, Roman (October 30, 2015). "Implementation of continuous-variable quantum key distribution with composable and one-sided-device-independent security against coherent attacks". Nature Communications. 6: 8795. Bibcode:2015NatCo...6.8795G. doi:10.1038/ncomms9795. PMC 4640132. PMID 26514280.
  30. ^ Ast, Stefan; Mehmet, Moritz; Schnabel, Roman (June 3, 2013). "High-bandwidth squeezed light at 1550 nm from a compact monolithic PPKTP cavity". Optics Express. 21 (11): 13572–13579. arXiv:1303.1925. Bibcode:2013OExpr..2113572A. doi:10.1364/oe.21.013572. ISSN 1094-4087. PMID 23736610. S2CID 9258803.
  31. ^ Hétet, G.; Glöckl, O.; Pilypas, K. A.; Harb, C.C.; Buchler, B.C.; Bachor, H.-A.; Lam, P.K. (2006). "Squeezed light for bandwidth-limited atom optics experiments at the rubidium D1 line". Journal of Physics B. 40 (1): 221–226. arXiv:quant-ph/0611204. Bibcode:2007JPhB...40..221H. doi:10.1088/0953-4075/40/1/020. ISSN 0953-4075. S2CID 1882589.
  32. ^ Kim, Saesun; Marino, Alberto M. (December 10, 2018). "Generation of 87Rb resonant bright two-mode squeezed light with four-wave mixing". Optics Express. 26 (25): 33366–33375. arXiv:1806.04797. Bibcode:2018OExpr..2633366K. doi:10.1364/OE.26.033366. ISSN 1094-4087. PMID 30645489. S2CID 51685095.