Next Article in Journal
Fusion of Enhanced and Synthetic Vision System Images for Runway and Horizon Detection
Previous Article in Journal
Towards Evaluating Proactive and Reactive Approaches on Reorganizing Human Resources in IoT-Based Smart Hospitals
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Highly Fluorescent Green Carbon Dots as a Fluorescent Probe for Detecting Mineral Water pH

1
School of Science, Jiangnan University, Wuxi 214122, China
2
School of Science, Jiangsu Provincial Research Center of Light Industrial Optoelectronic Engineering and Technology, Wuxi 214122, China
*
Author to whom correspondence should be addressed.
Submission received: 11 July 2019 / Revised: 13 August 2019 / Accepted: 27 August 2019 / Published: 3 September 2019
(This article belongs to the Section Chemical Sensors)

Abstract

:
In this report, high-brightness green carbon dots were successfully prepared using 3,5-diaminobenzoic acid as the sole precursor and synthesized in one step using a solvothermal strategy. Under the excitation of 365 nm ultraviolet light, the quantum yield of carbon dots is as high as 53.8%. Experiments revealed that the carbon dots are highly carbonized and the surface is rich in amino and carboxyl groups. The synthesized carbon dots have good water solubility, and are resistant to ions and temperature. The fluorescence intensity of CDs is sensitive to pH changes and is linearly correlated with the pH in the near-neutral range (pH = 6.0 to 9.0). Our experiments showed that carbon dots were sensitive and accurate fluorescent probes for measuring the pH value of drinking water, which could provide an effective method for measuring the pH value of water in the future.

Graphical Abstract

1. Introduction

Carbon dots (CDs) are a new type of zero-dimension photoluminescent nanomaterial with a size less than 10 nm [1]. CDs exhibit outstanding wide-range fluorescence, stable optical properties, and biocompatibility. They also have a simple and abundant synthetic path and pollution-free precursors. CDs have been found to have a series of interesting properties, researched by many scholars in recent years. For example, some unique optical properties such as long-wavelength emission can be applied to bioimaging [2,3,4]. Excitation-dependence is expected to play a role in multicolor imaging or LEDs [5,6]. In addition, CDs are considered to be detectable in response to some metal ions (Fe, Ag, and Hg) or pH due to their rich functional groups on their surface [7,8,9,10]. Therefore, CDs can be used as fluorescent probes for the detection of trace elements or pH in the environment or human body. In general, synthetic routes for preparing CDs are divided into two methods: bottom-up and top-down [11,12]. Compared to other synthetic routes for preparing CDs, the solvothermal method is an effective bottom-up method for synthesizing CDs that can be modified by polymerization and carbonization of precursors [13]. Thank to their excellent physical and chemical properties, there is no denying that CDs are promising nanomaterials to replace the traditional quantum dot in many fields. However, CDs’ research and application face several challenges due to their complex chemical structures, random surface functional groups, and low quantum yield (QY).
pH is an important parameter for living organisms. Biological activities can only be carried out within a limited pH range. A slight change of pH in the environment may have an effect on the organism. Therefore, it is important to observe changes in pH in the environment or in a living body in real time. As a new type of nanoluminescent material, many scholars have found that CDs’ rich fluorophores make them very sensitive to pH changes. At the same time, they have the advantages of fast response, high QY, and good visual recognition [14,15]. Many amino-rich organic materials are well suited for the synthesis of pH-sensitive CDs as precursors. For example, p-phenylenediamine and its isomers (m-phenylenediamine, o-phenylenediamine) are well suited for the synthesis of high-intensity, long-wavelength-emitting, pH-sensitive CDs. Jiao and her team chose p-phenylenediamine as the precursor and synthesized orange fluorescent nitrogen-doped CDs using hydrothermal methods. As the pH of the CDs increases, there is significant fluorescence enhancement in the pH range 1–8. It is therefore used as a biosensing platform to monitor fluctuations in the pH of living cells [16]. Precursors such as diethylamine and ethylenediamine are suitable for the synthesis of CDs with surface modification. Nie and co-workers used chloroform (CHCl3) and diethylamine (DEA) as synthetic raw materials to synthesize continuously adjustable full-color emission CDs by the solvothermal method by changing the reaction conditions. Based on its unique emission characteristics, a ratio pH sensor was constructed and applied to the measurement of intracellular pH values and cancer diagnosis [17]. However, most pH-dependent CDs have a large influence on the excitation wavelength [18,19], have a weak anti-ion interference ability [20,21], are easily affected by temperature changes [22], or are insufficiently sensitive to fluorescence changes in the near-neutral range of pH. This limits the application of CDs in the field of pH sensors. Therefore, it has been very valuable to develop pH-sensitive CDs with a simple synthetic route, high efficiency, and long-wavelength luminescence. Meanwhile, due to the different types of ions contained in the soil of different water sources, the pH value of drinking/mineral water will also change. This means that pH is an important parameter for evaluating the quality of drinking/mineral water. The current use of a pH meter is a common method for detecting the pH of water. Compared to pH meters, pH sensors based on fluorescent nanomaterials have higher sensitivity and can also be used for the detection of trace samples [23,24].
Herein, we synthesize high-quantum-yield green CDs with the sole precursor 3,5-diaminobenzoic acid by solvothermal one-pot synthesis (Scheme 1). After purification by silica gel column chromatography, the CDs were obtained. The prepared CDs have a high QY of 53.8% and are highly sensitive to pH, especially in the neutral pH ranges (pH = 6.0–9.0). Based on this feature, we use the CDs as a pH nanosensor for detecting the pH of commercially available mineral water. Experiments have shown that the CDs have reliable sensitivity as a pH sensor and can be used for small samples instead of traditional pH meters.

2. Materials and Methods

3,5-diaminobenzoic acid was purchased from Aladdin Industrial Corporation. Ethanol (≥99.7%), methanol (≥99.8%), dichloromethane (≥99.5%), and silica gel (Acuity FCP. 300–400 mesh) were obtained from Sinopharm Group Chemical Reagent Co., Ltd., Shanghai, China. All reagents were analytical reagent grade. BaCl2, CaCl2, CrCl2, CuCl2, FeCl2, FeCl3, KCl, MgCl2, MnCl2, NaCl, PbCl2, NaOH, HCl, NaH2PO4, Na2HPO4, citric acid, sodium citrate dihydrate (C6H5Na3O7·2H2O), and Tris were all purchased from Sinopharm Group Chemical Reagent Co., Ltd. Deionized (DI) water was used throughout the experiments. All aqueous solutions were prepared with ultrapure water (≥18.2 MΩ·cm) from a Labonova Smart system (Think-lab, Germany).

2.1. Characterizations

Transmission electron microscopy (TEM) image was gained from a JEOL (Peabody, MA, USA) 2100F microscope operating at a maximum acceleration voltage of 200 kV. Fourier transform infrared (FTIR) spectra were acquired on a Nicolet iS5 spectrometer (Thermo Fisher Scientific, Waltham, MA, USA) using KBr disks in the wavenumber range of 4000~400 cm−1. The X-ray photoelectron spectra (XPS) were recorded on an ESCALAB (Waltham, MA, USA) 250xi X-ray photoelectron spectrometer. To describe the CDs’ optical characteristics, the UV-Vis absorption spectra were measured on an 2048x14-USB2 fiber optic spectrometer (Aventes, Hemmingen, Germany). Fluorescence emission spectra and excitation spectra were recorded on FLS920 (Edinburgh, Livingston, England).

2.2. Preparation of CDs and pH Buffer Solutions

The CDs was prepared using a one-step hydrothermal process. Firstly, 0.4 g 3,5-diaminobenzoic acid was dissolved in 40 mL ethanol. Then, the mixture was moved to a 100-mL tetrafluoroethylene-lined autoclave and heated at 180 °C in an electric oven for 12 h. After cooling to room temperature, the dark brown reaction was filtered and concentrated in vacuo to one-quarter of the original volume. The purification of the CDs was carried out by column chromatography. The stationary phase was silica gel and the mobile phase was a mixture of methanol and dichloromethane in a ratio of 4:1. Finally the purified CDs were freeze-dried into a powder (Figure S1) using a lyophilizer and stored in a refrigerator.
A series of pH buffer solutions were prepared at 0.1 mol/L. pH 2–6 solutions were prepared using citric acid and sodium citrate; pH = 7–8 solutions were prepared using tris and hydrochloric acid; pH = 9–13 solutions were prepared using sodium hydride and sodium hydrogen phosphate, adjusted by adding different quantities of NaOH solution. All pH buffer solutions were prepared on the same day.

2.3. QY Measurements

The QY of the CDs in water was determined by the reference method. The reference material is quinine sulfate (QY = 55% in 0.1 M H2SO4) and the formula is as follows [4]:
Φ x = A s I s · I x A x · n x 2 n s 2 · Φ s ,
where Φ x is the QY of the CDs, A is the absorbance of the CDs, and I is the integral intensity (excited at 365 nm). n is the refractive index (1.33 in water) and the subscript “s” represents quinine sulfate. In order to make the results more accurate, we prepared a series of different concentrations of the CDs and reference solution (adjusting the concentration so that their absorbance is within 0–0.2).

2.4. Method for Detecting the pH Value of Mineral Water

There were eight kinds of mineral water samples used in the experiment: Ganten mineral water, NongFu mineral water (suitable for infants), NongFu mineral water, Alps mineral water, LIFELONG mineral water, Evergrande Spring low sodium mineral water, Perrier gassy water and Wahaha soda water. First 0.5 mL of a diluted aqueous solution of CDs was added to a 5 mL mineral water sample and buffer solution with pH = 6 and pH = 8 (for emission intensity correction). Then this was shaken well and we measured the fluorescence spectrum of the solution using FLS920. The excitation wavelength was 390 nm and the emission range was from 400 nm to 700 nm. The obtained integrated intensity was taken into the pH change fitting curve to calculate the sample pH value.

3. Results

3.1. Characterizations of the CDs

The distribution and size of the CDs can be observed from the TEM image (Figure 1a). It can be seen that the CDs are globular and well-dispersed. By counting the size of the CDs, it was found that the diameters of the CDs are within the range of 5–11 nm and the average diameter is 7.58 nm. Compared with other CDs, the CDs we prepared are larger, indicating that they have a higher degree of carbonization. The FTIR spectrum can identify functional groups on the surface of the CDs to evaluate the surface function. Figure 1b depicts the FTIR spectrum of the CDs. The obvious absorption bands at 3362 and 1383 cm−1 are consistent with the stretching vibration of the -NH group, which indicated that the surface of the CDs contains a large amount of amino groups. Studies have shown that more amino groups are favorable for the fluorescence emission of CDs, which is the reason for the high QY of the CDs [25,26]. The absorption bands at 3451 and 1466 cm−1 belong to -OH and -C=O, confirming the presence of carboxyl groups, while 1614 cm−1 is from -C=N in the phenazine structure. To characterize the elemental composition of the CDs, X-ray photoelectron spectroscopy (XPS) was used as in Figure 1c. Three dominant peaks at 531.2 (O1s), 399.4 (N1s), and 285.0 eV (C1s), which are composed of O1s, N1s, and C1s, were observed [5,27]. The O, N, and C atom ratio was 15.7%, 6.3%, and 78.0%, respectively. The high-resolution XPS spectrum of C1s (Figure 1d) exhibits three characteristic peaks of C=C/C-C, C-N/C-O, and COOH with binding energies at about 284.7, 285.1, and 288.2 eV, respectively. In Figure 1e, N1s contains three peaks of 398.9, 399.4, and 400.4 eV, indicating the presence of pyridine-N, amino-N, and pyrrole-N structures. The high-resolution XPS spectra of O1s shown in Figure 1f indicate that the O1s could be resolved into two peaks of 531.2 eV (C=O) and 532.4 eV (C-O).

3.2. The Optical Properties of the CDs

The optical properties, including the UV-Vis absorption, fluorescence excitation, and emission of the CDs, are investigated fully. It can be seen from the UV-visible absorption spectrum that the CDs have multiple electronic absorption transitions and there are three absorption peaks in the absorption spectra of the CDs (Figure S2). There are strong absorption bands at 229 nm and 260 nm, which can be attributed to the vibration of π-π* (aromatic C=C) and n–π (C-N) transitions [28,29]. This means that a large π bond is formed between the molecules of the CDs. The wide absorption band at 360 nm is caused by n-π* transition due to the C=O bond on the surface of the CDs [30], which describe the presence of carboxyl groups and amino substituents. The excitation spectrum of the CDs is similar to the absorption spectrum (Figure 2a), with two excitation peaks at 264 nm and 390 nm, and the fluorescence emission reaches a maximum at 390 nm excitation. An excitation peak close to the peak position of the absorption spectrum means that the green emission of the CDs is caused by the carboxyl group and/or C-N structure of the surface of the CDs. Figure 2b displays the fluorescence emission spectra of the CDs excited by different excitation wavelengths. It emerged that there was an unvaried emission at 493 nm under the varied excitations. This observation also implies that the PL emission of CDs is caused by one state of emission, which also proves the uniform size of the CDs [31,32]. The purified CDs have a high quantum yield of 53.8%, and the measurement methods and results are shown in Figure S3. It can be seen that the CDs have good QY in water solvents at a neutral pH. The high QY allows the CDs to be applied as a light sensor that can be recognized by the naked eye.

3.3. Fluorescent Response of the CDs to pH

pH plays a critical role in biological systems, and small changes in pH in the environment can be fatal to living organisms. In the experiments, we studied the response of the CDs to pH by observing changes in the fluorescence emission spectra in different pH buffer solvents. As shown in Figure 3a, the fluorescence intensity of the CDs is stronger under acidic conditions, but sharply reduced under alkaline conditions. The strong response of the CDs to pH is considered to be derived from the protonation–deprotonation of the amino and carboxyl groups on their surface. As shown in the inset of Figure 3a, the fluorescence intensity of the CDs decreases with the increase of pH at 390 nm excitation from 4.5 to 12. The change trend can be fitted with the Boltzmann equation: I = 2626920 + 90256180/(1 + exp((pH − 7.3)/0.49)) (R2 = 0.999, pKa = 7.3). Figure S4 shows that a linear relationship between the photoluminescence (PL) intensity and pH was observed in the near-neutral pH range (pH = 6.0–9.0, R2 = 0.985). When using concentrated sodium hydroxide and a hydrochloric acid solution to repeatedly adjust the pH of CDs and test their fluorescence intensity, we found that CDs are provided with good reversibility, which means that their PL behavior was reversible and sensitive (Figure 3b). Meanwhile, the response of different concentrations of CDs (expressed in absorbance) to pH was also tested (in Figure S5). In the range of 0.05 to 0.24 in absorbance (at a wavelength of 390 nm), the CDs have a good response to pH. This means that the prepared CDs can be used as a probe to detect the pH of the sample to be tested even in a small amount. The CDs’ PL intensity attenuated sharply, which explains how the CDs can be used as a sensitive pH sensor in environmental and biological systems.

3.4. Resistance to Temperature and Ion Interference and Luminescence Stability

In order to show the feasibility of CDs in practical applications, fluorescence intensity of CDs at different temperatures and the anti-ion interference capability of the CDs was tested (Ex = 390 nm). Herein, the CDs were placed in an environment of 10–50 °C to measure the fluorescence intensity. Figure 3c shows that CDs have only slight fluorescence changes at 10–50 °C. Meanwhile, we found that the fluorescence intensity of CDs did not change significantly as the concentration of the NaCl solution increased. This means that the luminescence of CDs is basically not affected by the external environment, so they are ideal as detectors for pH detection as a sensor. The test of luminescence stability was displayed in Figure S6. In the light stability test experiment, CDs were exposed under a 600 W fluorescent lamp for 0–16 h to probe their luminescence stability. The experiments proved that the CDs are a luminescent nanomaterial with favorable stability. At the same time, the response of CDs to common metal ions (Ba2+, Ca2+, Cr2+, Cu2+, Fe2+, Fe3+, K+, Na+, Mg2+, Mn2+, Pb2+) has also been investigated. It can be concluded from Figure 3d that the fluorescence intensity of the CDs does not substantially change in the aqueous solutions of metal ions of 0.5 mM concentration, except for a slight response to iron ions, which can be attributed to the interactions between iron ions and amino or carboxyl groups on the surface of CDs [25,33]. So we can rule out the interference of typical ions in the practical applications of CDs such as cell imaging and water detection.

3.5. pH Detection in Mineral Water Samples

In order to verify the feasibility of the application of the fluorescent CDs pH sensor in actual samples, we selected some brands of mineral water as test samples, using the commonly-used pH meter and a CDs sensor for pH testing. The test results are shown in Table 1. It can be seen that the pH values measured by the CDs sensor are basically consistent with the pH value measured by the pH meter, which proves the feasibility of using CDs as a fluorescent pH sensor. At the same time, as zero-dimensional nanomaterials, CDs can play a role even in the detection of trace amounts of samples.

4. Conclusions

In summary, we successfully used a simple strategy to synthesize CDs in one step. The prepared CDs emit a bright green light with an average size of 7.58 nm. It has been shown that the surface is rich in carboxyl and amino groups. The CDs have many excellent optical features such as good water solubility, up to 53.8% QY, good light stability, and anti-ion interference capability. At the same time, we found that the CDs have a sensitive response to pH changes, especially in the near-neutral pH range. Therefore, we designed a simple method for testing the pH of mineral water using the CDs as a probe. Studies have shown that CDs have high sensitivity as pH sensors and are expected to be applied in the future.

Supplementary Materials

The following are available online at https://www.mdpi.com/1424-8220/19/17/3801/s1, Figure S1: The image of the CDs solid powder. Figure S2: Absorption spectrum of the CDs. Figure S3: Plot of integrated PL intensity of the CDs and quinine sulfate (referenced dye) as a function of optical absorbance at 365 nm and relevant data. Figure S4: Photo stability of CDs under the irradiation of a 600W light at various times. Figure S5: Response of CDs to pH at different absorbances (at 390 nm). Figure S6: Photo stability of CDs under the irradiation of a 600W light at various times.

Author Contributions

L.L. and T.W. designed the synthesis strategy of the whole experiment and CDs; T.W. carried out the synthesis, purification and characterization of CDs; G.C., L.L. and T.W. designed the application of CDs; G.C. and Y.W. supervised the whole research process and improved the experimental method; Finally, the data was collated and manuscript was written by T.W., and all the authors participated in the review and editing of the manuscript.

Acknowledgments

This work was supported by the National Key R&D Program of China (2018YFC1604204), the National Natural Science Foundation of China (61378037), the National First-class Discipline Program of Food Science and Technology (JUFSTR20180302), the National Key Research and Development Program of China (2018YFC1604204 and 2018YFD0400402).

Conflicts of Interest

The authors declare no conflict of interest regarding the publication of this paper.

References

  1. Baker, S.N.; Baker, G.A. Luminescent carbon nanodots: Emergent nanolights. Angew. Chem. Int. Ed. 2010, 49, 6726–6744. [Google Scholar] [CrossRef] [PubMed]
  2. Cao, L.; Wang, X.; Meziani, M.J.; Lu, F.; Wang, H.; Luo, P.; Lin, Y.; Harruff, B.A.; Veca, L.M.; Murray, D.; et al. Carbon dots for multiphoton bioimaging. J. Am. Chem. Soc. 2007, 129, 11318–11319. [Google Scholar] [CrossRef] [PubMed]
  3. Ding, H.; Yu, S.B.; Wei, J.S.; Xiong, H.M. Full-color light-emitting carbon dots with a surface-state-controlled luminescence mechanism. ACS Nano 2015, 10, 484–491. [Google Scholar] [CrossRef] [PubMed]
  4. Jiang, K.; Sun, S.; Zhang, L.; Lu, Y.; Wu, A.; Cai, C.; Lin, H. Red, Green and blue luminescence by carbon dots: Full-color emission tuning and multicolor cellular imaging. Angew. Chem. Int. Ed. 2015, 127, 5450–5453. [Google Scholar] [CrossRef]
  5. Pan, L.; Sun, S.; Zhang, A.; Jiang, K.; Zhang, L.; Dong, C.; Huang, Q.; Wu, A.; Lin, H. Truly fluorescent excitation-dependent carbon dots and their applications in multicolor cellular imaging and multidimensional sensing. Adv. Mater. 2015, 27, 7782–7787. [Google Scholar] [CrossRef] [PubMed]
  6. Chen, Y.; Zheng, M.; Xiao, Y.; Dong, H.; Zhang, H.; Zhuang, J.; Hu, H.; Lei, B.; Liu, Y. A self quenching resistant carbon dot powder with tunable solid state fluorescence and construction of dual fluorescence morphologies for white light emission. Adv. Mater. 2016, 28, 312–318. [Google Scholar] [CrossRef] [PubMed]
  7. Qian, Z.; Ma, J.; Shan, X.; Feng, H.; Shao, L.; Chen, J. Highly luminescent N-doped carbon quantum dots as an effective multifunctional fluorescence sensing platform. Chem. Eur. J. 2014, 20, 2254–2263. [Google Scholar] [CrossRef]
  8. Tan, H.C.; Zhao, W.H.; Qi, Q.; Zhang, R.; Zuo, Y.Y.; Yang, L.J. Green synthesis of nitrogen-doped fluorescent carbon quantum dots for selective detection of iron. Fullerenes Nanotubes Carbon Nanostruct. 2017, 25, 417–422. [Google Scholar] [CrossRef]
  9. Luo, L.; Wang, P.; Wang, Y.; Wang, F. pH assisted selective detection of Hg(II) and Ag(I) based on nitrogen-rich carbon dots. Sens. Actuators Chem. 2018, 273, 1640–1647. [Google Scholar] [CrossRef]
  10. Ding, Y.Y.; Gong, X.J.; Liu, Y.; Lu, W.J.; Gao, Y.F.; Xian, M.; Shuang, S.M.; Dong, C. Facile preparation of bright orange fluorescent carbon dots and the constructed biosensing platform for the detection of pH in living cells. Talanta 2018, 189, 8–15. [Google Scholar] [CrossRef]
  11. Lim, S.Y.; Shen, W.; Gao, Z. Carbon quantum dots and their applications. Chem. Soc. Rev. 2015, 44, 362–381. [Google Scholar] [CrossRef] [PubMed]
  12. Sun, X.; Lei, Y. Fluorescent carbon dots and their sensing applications. Trends Anal. Chem. 2017, 89, 163–180. [Google Scholar] [CrossRef]
  13. Sharma, S.; Umar, A.; Sood, S.; Mehta, S.K.; Kansal, S.K. Photoluminescent C-dots: An overview on the recent development in the synthesis, physiochemical properties and potential applications. J. Alloys Compd. 2018, 748, 818–853. [Google Scholar] [CrossRef]
  14. Shangguan, J.; He, D.; He, X.; Wang, K.; Xu, F.; Liu, J.; Huang, J. Label-Free Carbon-Dots-Based Ratiometric Fluorescence pH nanoprobes for intracellular pH sensing. Anal. Chem. 2016, 88, 7837–7843. [Google Scholar] [CrossRef] [PubMed]
  15. Lan, C.; Zhang, L.; Shi, B.; Chen, D.; Zhao, L.; Zhao, S. Fluorescent carbon dots with tunable emission by dopamine for sensing of intracellular pH, elementary arithmetic operations and a living cell imaging based INHIBIT logic gate. J. Mater. Chem. B 2017, 5, 5265–5271. [Google Scholar] [CrossRef]
  16. Jiao, Y.; Gong, X.; Han, H.; Gao, Y.; Lu, W.; Liu, Y.; Dong, C. Facile synthesis of orange fluorescence carbon dots with excitation independent emission for pH sensing and cellular imaging. Anal. Chim. Acta 2018, 1042, 125–132. [Google Scholar] [CrossRef]
  17. Nie, H.; Li, M.; Li, Q.; Liang, S.; Tan, Y.; Sheng, L.; Shi, W.; Zhang, S.X.A. Carbon dots with continuously tunable full-color emission and their application in ratiometric pH sensing. Chem. Mater. 2014, 26, 3104–3112. [Google Scholar] [CrossRef]
  18. Barati, A.; Shamsipur, M.; Abdollahi, H. Carbon dots with strong excitation-dependent fluorescence changes towards pH. Application as nanosensors for a broad range of pH. Anal. Chim. Acta 2016, 931, 25–33. [Google Scholar] [CrossRef]
  19. Wang, C.; Xu, Z.; Zhang, C. Polyethyleneimine-functionalized fluorescent carbon dots: Water stability, pH sensing, and cellular imaging. Chem. Nano. Mat. 2015, 1, 122–127. [Google Scholar] [CrossRef]
  20. Sun, Y.; Wang, X.; Wang, C.; Tong, D.; Wu, Q.; Jiang, K.; Yang, M. Red emitting and highly stable carbon dots with dual response to pH values and ferric ions. Microchim. Acta 2018, 185, 1–8. [Google Scholar] [CrossRef]
  21. Zhang, M.; Su, R.; Zhong, J.; Fei, L.; Cai, W.; Guan, Q.; Xu, Q. Red/orange dual-emissive carbon dots for pH sensing and cell imaging. J. Nano Res. 2019, 12, 815–821. [Google Scholar] [CrossRef]
  22. Wang, C.; Xu, Z.; Cheng, H.; Lin, H.; Humphrey, M.G.; Zhang, C. A hydrothermal route to water-stable luminescent carbon dots as nanosensors for pH and temperature. Carbon 2015, 82, 87–95. [Google Scholar] [CrossRef]
  23. Wang, L.; Li, M.; Li, W.; Han, Y.; Liu, Y.; Li, Z.; Zhang, B.; Pan, D. Rationally designed an efficient dual-mode colorimetric/fluorescence sensor based on carbon dots for detection of pH and Cu2+ ions. ACS Sustain. Chem. Eng. 2018, 1–18. [Google Scholar] [CrossRef]
  24. Song, Z.; Quan, F.; Xu, Y.; Liu, M.; Cui, L.; Liu, J. Multifunctional N, S co-doped carbon quantum dots with pH-and thermo-dependent switchable fluorescent properties and highly selective detection of glutathione. Carbon 2016, 104, 169–178. [Google Scholar] [CrossRef]
  25. Atchudan, R.; Edison, T.N.J.I.; Aseer, K.R.; Perumal, S.; Karthik, N.; Lee, Y.R. Highly fluorescent nitrogen-doped carbon dots derived from Phyllanthus acidus utilized as a fluorescent probe for label-free selective detection of Fe3+ ions, live cell imaging and fluorescent ink. Biosens. Bioelectron. 2018, 99, 303–311. [Google Scholar] [CrossRef] [PubMed]
  26. Zhang, R.; Chen, W. Nitrogen-doped carbon quantum dots: Facile synthesis and application as a “turn-off” fluorescent probe for detection of Hg2+ ions. Biosens. Bioelectron. 2014, 55, 83–90. [Google Scholar] [CrossRef] [PubMed]
  27. Ji, H.; Zhou, F.; Gu, J.; Shu, C.; Xi, K.; Jia, X. Nitrogen-doped carbon dots as a new substrate for sensitive glucose determination. Sensors 2016, 16, 630. [Google Scholar] [CrossRef]
  28. Zhang, T.; Zhu, J.; Zhai, Y.; Wang, H.; Bai, X.; Dong, B.; Song, H. A novel mechanism for red emission carbon dots: Hydrogen bond dominated molecular states emission. Nanoscale 2017, 9, 13042–13051. [Google Scholar] [CrossRef]
  29. Zhu, S.; Song, Y.; Zhao, X.; Shao, J.; Zhang, J.; Yang, B. The photoluminescence mechanism in carbon dots (graphene quantum dots, carbon nanodots, and polymer dots): Current state and future perspective. J. Nano Res. 2015, 8, 355–381. [Google Scholar] [CrossRef]
  30. Wang, H.; Sun, C.; Chen, X.; Zhang, Y.; Colvin, V.L.; Rice, Q.; Seo, J.; Feng, S.; Wang, S.; Yu, W.W. Excitation wavelength independent visible color emission of carbon dots. Nanoscale 2017, 9, 1909–1915. [Google Scholar] [CrossRef]
  31. Jiang, K.; Sun, S.; Zhang, L.; Wang, Y.; Cai, C.; Lin, H. Bright-yellow-emissive N-doped carbon dots: Preparation, cellular imaging, and bifunctional sensing. ACS Appl. Mater. Interfaces 2015, 7, 23231–23238. [Google Scholar] [CrossRef] [PubMed]
  32. Lu, W.; Gong, X.; Yang, Z.; Zhang, Y.; Hu, Q.; Shuang, S.; Dong, C.; Choi, M.M.F. High-quality water-soluble luminescent carbon dots for multicolor patterning, sensors, and bioimaging. RSC Adv. 2015, 5, 16972–16979. [Google Scholar] [CrossRef]
  33. Lu, X.; Liu, C.; Wang, Z.; Yang, J.; Xu, M.; Dong, J.; Wang, P.; Gu, J.; Cao, F. Nitrogen-doped carbon nanoparticles derived from silkworm excrement as on–off–on fluorescent sensors to detect Fe(III) and biothiols. Nanomaterials 2018, 8, 443. [Google Scholar] [CrossRef] [PubMed]
Scheme 1. The synthesis route and purification method of the CDs.
Scheme 1. The synthesis route and purification method of the CDs.
Sensors 19 03801 sch001
Figure 1. (a) TEM image of the CDs. The inset in (a) is the particle size distribution histogram. (b) FTIR image of the CDs. (c) XPS survey spectrum of the CDs. (df) High-resolution XPS spectra of C1s, N1s, and O1s, respectively.
Figure 1. (a) TEM image of the CDs. The inset in (a) is the particle size distribution histogram. (b) FTIR image of the CDs. (c) XPS survey spectrum of the CDs. (df) High-resolution XPS spectra of C1s, N1s, and O1s, respectively.
Sensors 19 03801 g001
Figure 2. The optical properties of CDs. (a) The normalized PL excitation and emission spectra of CDs; (b) PL spectra of CDs at different excitation wavelengths.
Figure 2. The optical properties of CDs. (a) The normalized PL excitation and emission spectra of CDs; (b) PL spectra of CDs at different excitation wavelengths.
Sensors 19 03801 g002
Figure 3. (a) The PL spectra of CDs as the pH increases from 4.5 to 12, excited at 400 nm. The inset displays sigmoidal fitting of pH-dependent fluorescence intensity. (b) PL intensity of CDs upon cycling the pH value seven times between 4 and 10. (c) PL relative intensity of CDs at different temperatures and NaCl solution with various concentrations. (d) The response of the CDs in various metal ions with a concentration of 0.5 mM.
Figure 3. (a) The PL spectra of CDs as the pH increases from 4.5 to 12, excited at 400 nm. The inset displays sigmoidal fitting of pH-dependent fluorescence intensity. (b) PL intensity of CDs upon cycling the pH value seven times between 4 and 10. (c) PL relative intensity of CDs at different temperatures and NaCl solution with various concentrations. (d) The response of the CDs in various metal ions with a concentration of 0.5 mM.
Sensors 19 03801 g003
Table 1. Measurement of pH in mineral water samples.
Table 1. Measurement of pH in mineral water samples.
Mineral Water BrandpH apH b
Ganten5.935.9
NongFu (suitable for infants)7.137.3
NongFu7.347.4
Alps6.806.6
LIFELONG7.747.7
Evergrande Spring (low sodium)7.217.2
Perrier (carbonated water)5.326.2
Wahaha (soda water)8.097.9
a pH was measured with a PHB-1 Instruments pH meter (San Xin, Shanghai, China). b pH was measured with the fluorescence pH sensor based on the CDs in this work.

Share and Cite

MDPI and ACS Style

Wang, T.; Chen, G.; Li, L.; Wu, Y. Highly Fluorescent Green Carbon Dots as a Fluorescent Probe for Detecting Mineral Water pH. Sensors 2019, 19, 3801. https://doi.org/10.3390/s19173801

AMA Style

Wang T, Chen G, Li L, Wu Y. Highly Fluorescent Green Carbon Dots as a Fluorescent Probe for Detecting Mineral Water pH. Sensors. 2019; 19(17):3801. https://doi.org/10.3390/s19173801

Chicago/Turabian Style

Wang, Tingyu, Guoqing Chen, Lei Li, and Yamin Wu. 2019. "Highly Fluorescent Green Carbon Dots as a Fluorescent Probe for Detecting Mineral Water pH" Sensors 19, no. 17: 3801. https://doi.org/10.3390/s19173801

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop