The High Voltage distribution system of the ATLAS Tile Calorimeter and its performance during data taking

, , , , , , , , , , , , , , , and

Published 6 August 2018 © 2018 IOP Publishing Ltd and Sissa Medialab
, , Citation D. Calvet et al 2018 JINST 13 P08006 DOI 10.1088/1748-0221/13/08/P08006

1748-0221/13/08/P08006

Abstract

This article documents the characteristics of the high voltage (HV) system of the hadronic calorimeter TileCal of the ATLAS experiment. Such a system is suitable to supply reliable power distribution into particles physics detectors using a large number of PhotoMultiplier Tubes (PMTs). Measurements performed during the 2015 and 2016 data taking periods of the ATLAS detector show that its performance, in terms of stability and noise, fits the specifications. In particular, almost all the PMTs show a voltage instability smaller than 0.5 V corresponding to a gain stability better than 0.5%. A small amount of channels was found not working correctly. To diagnose the origin of such defects, the results of the HV measurements were compared to those obtained using a Laser system. The analysis shows that less than 0.2% of the about 10 thousand HV channels were malfunctioning.

Export citation and abstract BibTeX RIS