CERN Accelerating science

CERN Document Server 找到 2,043 笔记录  1 - 10下一个最後  跳到记录: 检索需时 0.47 秒. 
1.
Active dosimetry for VHEE FLASH radiotherapy using beam profile monitors and charge measurements / Rieker, Vilde F (CERN ; Oslo U.) ; Corsini, Roberto (CERN) ; Stapnes, Steinar (CERN) ; Adli, Erik (Oslo U.) ; Farabolini, Wilfrid (CERN) ; Grilj, Veljko (SUBATECH, Nantes) ; Sjobak, Kyrre N (Oslo U.) ; Wroe, Laurence M (CERN) ; Aksoy, Avni (CERN ; Ankara U.) ; Robertson, Cameron S (Oxford U.) et al.
The discovery of the FLASH effect has revealed a high potential for treating cancer more efficiently by sparing healthy tissue. The surge in related medical research activities over the last couple of years has triggered a demand for technology with the capability of generating and measuring ionizing radiation at ultra-high doserates (UHDR). [...]
2024 - 12 p. - Published in : Nucl. Instrum. Methods Phys. Res., A 1069 (2024) 169845 Fulltext: PDF;
2.
Plastic Scintillator Dosimetry of Ultrahigh Dose-Rate 200 MeV Electrons at CLEAR / Hart, Alexander (Victoria U.) ; Giguère, Cloé (Laval U.) ; Bateman, Joseph (Oxford U.) ; Korysko, Pierre (Oxford U.) ; Farabolini, Wilfrid (CERN) ; Rieker, Vilde (CERN ; Oslo U.) ; Esplen, Nolan (Victoria U.) ; Corsini, Roberto (CERN) ; Dosanjh, Manjit (Oxford U.) ; Beaulieu, Luc (Laval U.) et al.
Very-high-energy electron (VHEE) beams with energies greater than 100 MeV may be promising candidates for FLASH radiotherapy due to their favorable dose distributions and accessibility of ultrahigh dose rates (UHDRs). Combining VHEE with the normal tissue-sparing FLASH effect of UHDR radiotherapy could improve patient outcomes. [...]
2024 - 9 p. - Published in : IEEE Sensors J. 24 (2024) 14229-14237
3.
Development of a novel fibre optic beam profile and dose monitor for very high energy electron radiotherapy at ultrahigh dose rates / Bateman, Joseph J (JAI, UK) ; Buchanan, Emma (CERN) ; Corsini, Roberto (CERN) ; Farabolini, Wilfrid (CERN) ; Korysko, Pierre (JAI, UK ; CERN) ; Larsen, Robert Garbrecht (CERN ; Groningen U.) ; Malyzhenkov, Alexander (CERN) ; Ruiz, Iñaki Ortega (CERN) ; Rieker, Vilde (CERN ; Oslo U.) ; Gerbershagen, Alexander (Groningen U.)
Objective. Very high energy electrons (VHEE) in the range of 50–250 MeV are of interest for treating deep-seated tumours with FLASH radiotherapy (RT). [...]
2024 - 16 p. - Published in : Phys. Med. Biol. 69 (2024) 085006 Fulltext: PDF;
4.
Real-time Plastic Scintillation Dosimetry of Ultra-High Dose Rate Very High Energy Electrons (VHEE) at CERN CLEAR Facility / Giguère, Cloé (Laval U.) ; Hart, Alexander (Victoria U.) ; Bateman, Joseph (Oxford U.) ; Korysko, Pierre (Oxford U. ; CERN) ; Farabolini, Wilfrid (CERN) ; LeChasseur, Yoan (McGill U.) ; Bazalova-Carter, Magdalena (Victoria U.) ; Beaulieu, Luc (Laval U.)
Very High Energy Electrons (VHEE) that can theoretically treat deep-seated tumours and be delivered at ultra-high dose rates (UHDR) could be the solution to translate FLASH radiotherapy into the clinic. Standard dosimeters have limited application in those extreme conditions, but dose-rate independent and fast-response plastic scintillation detectors (PSDs) are a potential alternative to overcome this. [...]
2024 - 4 p. - Published in : J. Phys. : Conf. Ser. 2799 (2024) 012016 Fulltext: PDF;
In : 13th International Conference on 3D dosimetry (IC3DDose 2024), Aarhus, Denmark, 17 - 19 Jun 2024, pp.012016
5.
Methods for VHEE/FLASH Radiotherapy Studies and High Dose Rate Dosimetry at the CLEAR User Facility / Korysko, Pierre (U. Oxford (main) ; CERN) ; Bateman, Joseph (U. Oxford (main) ; CERN) ; Corsini, Roberto (CERN) ; Dyks, Luke (CERN) ; Farabolini, Wilfrid (CERN) ; Rieker, Vilde (CERN) ; Robertson, Cameron (U. Oxford (main) ; CERN)
The CERN Linear Electron Accelerator for Research (CLEAR), operating since 2017, is a user facility providing electron beams for a varied and large range of experiments. The accelerator can generate a 60-220 MeV electron beam and it was recently selected to study the feasibility of using Very High Energy Electrons (VHEE) at Ultra High Dose Rate (UHDR) for cancer radiotherapy. [...]
2022 - 4 p. - Published in : JACoW LINAC 2022 (2022) 758-761 Fulltext: PDF;
In : 31st Linear Accelerator Conference (LINAC22), Liverpool, UK, 28 Aug - 2 Sep 2022, pp.758-761
6.
Radiation damage and recovery of plastic scintillators under ultra-high dose rate 200 MeV electrons at CERN CLEAR facility / Giguère, Cloé (Laval U.) ; Hart, Alexander (Victoria U.) ; Bateman, Joseph (Oxford U.) ; Korysko, Pierre (Oxford U. ; CERN) ; Farabolini, Wilfrid (CERN) ; LeChasseur, Yoan (Quebec U., Montreal) ; Bazalova-Carter, Magdalena (Victoria U.) ; Beaulieu, Luc (Laval U.)
The FLASH effect holds significant potential in improving radiotherapy treatment outcomes. [...]
arXiv:2410.12535.
- 14.
Fulltext
7.
VHEE FLASH sparing effect measured at CLEAR, CERN with DNA damage of pBR322 plasmid as a biological endpoint / Wanstall, Hannah C (Manchester U. ; Daresbury) ; Korysko, Pierre (Oxford U. ; CERN) ; Farabolini, Wilfred (CERN) ; Corsini, Roberto (CERN) ; Bateman, Joseph J (Oxford U., Theor. Phys.) ; Rieker, Vilde (CERN ; Oslo U.) ; Hemming, Abigail (U. Manchester (main)) ; Henthorn, Nicholas T (U. Manchester (main) ; Manchester U.) ; Merchant, Michael J (Manchester U.) ; Santina, Elham (Manchester U.) et al.
Ultra-high dose rate (UHDR) irradiation has been shown to have a sparing effect on healthy tissue, an effect known as ‘FLASH’. This effect has been studied across several radiation modalities, including photons, protons and clinical energy electrons, however, very little data is available for the effect of FLASH with Very High Energy Electrons (VHEE). [...]
2024 - 13 p. - Published in : Sci. Rep. 14 (2024) 14803 Fulltext: PDF;
8.
A novel fibre optic monitor for VHEE UHDR beam monitoring: first tests at CLEAR / Bateman, Joseph (JAI, UK ; CERN) ; Buchanan, Emma (CERN) ; Corsini, Roberto (CERN) ; Gerbershagen, Alexander (Groningen U.) ; Ortega Ruiz, Inaki (CERN) ; Dosanjh, Manjit (JAI, UK ; CERN) ; Farabolini, Wilfrid (CERN) ; Rieker, Vilde (CERN ; Oslo U.) ; Korysko, Pierre (JAI, UK ; CERN) ; Malyzhenkov, Alexander (CERN)
Beam monitoring for Ultra High Dose Rate (UHDR) radiation therapy using pulsed beams, i.e. Very High Energy Electrons (VHEE), is a major challenge. [...]
2023 - Published in : JACoW IPAC 2023 (2023) THPL041 Fulltext: PDF;
In : 14th International Particle Accelerator Conference (IPAC 2023), Venice, Italy, 7 - 12 May 2023, pp.THPL041
9.
VHEE High Dose Rate Dosimetry Studies in CLEAR / Rieker, Vilde (CERN) ; Bateman, Joseph (JAI, UK ; CERN) ; Corsini, Roberto (CERN) ; Dyks, Luke (CERN ; Oxford U.) ; Farabolini, Wilfrid (IRFU, Saclay) ; Korysko, Pierre (Oxford U. ; CERN)
The 200 MeV electron beam of the CERN Linear Accelerator for Research (CLEAR) user facility at CERN has been intensively used to study the potential use of Very High Energy Electrons (VHEE) in cancer radiotherapy. In particular, irradiation tests have been performed in the high dose rate regime, which has gained a lot of interest for the so called FLASH biological effect, in which cancer cells are damaged while healthy tissue is largely spared. [...]
2022 - 4 p. - Published in : JACoW IPAC 2022 (2022) 3026-3029 Fulltext: PDF;
In : 13th International Particle Accelerator Conference (IPAC 2022), Bangkok, Thailand, 12 - 17 Jun 2022, pp.3026-3029
10.
CERN-based experiments and Monte-Carlo studies on focused dose delivery with very high energy electron (VHEE) beams for radiotherapy applications / Whitmore, L (Manchester U. ; Cockcroft Inst. Accel. Sci. Tech. ; Texas U., Houston) ; Mackay, R I (Manchester U.) ; van Herk, M (Manchester U.) ; Korysko, P (Oxford U. ; CERN) ; Farabolini, W (CERN) ; Malyzhenkov, A (CERN) ; Corsini, R (CERN) ; Jones, R M (Manchester U. ; Cockcroft Inst. Accel. Sci. Tech.)
Very High Energy Electron (VHEE) beams are a promising alternative to conventional radiotherapy due to their highly penetrating nature and their applicability as a modality for FLASH (ultra-high dose-rate) radiotherapy. The dose distributions due to VHEE need to be optimised; one option is through the use of quadrupole magnets to focus the beam, reducing the dose to healthy tissue and allowing for targeted dose delivery at conventional or FLASH dose-rates. [...]
2024 - 15 p. - Published in : Sci. Rep. 14 (2024) 11120 Fulltext: PDF;

没有寻找到什么? 尝试在以下的服务器查寻:
recid:2914802 在 Amazon
recid:2914802 在 CERN EDMS
recid:2914802 在 CERN Intranet
recid:2914802 在 CiteSeer
recid:2914802 在 Google Books
recid:2914802 在 Google Scholar
recid:2914802 在 Google Web
recid:2914802 在 IEC
recid:2914802 在 IHS
recid:2914802 在 INSPIRE
recid:2914802 在 ISO
recid:2914802 在 KISS Books/Journals
recid:2914802 在 KISS Preprints
recid:2914802 在 NEBIS
recid:2914802 在 SLAC Library Catalog