CERN Accelerating science

CERN Document Server 2,038 záznamov nájdených  1 - 10ďalšíkoniec  skoč na záznam: Hľadanie trvalo 0.04 sekúnd. 
1.
Online monitoring for proton therapy: A real-time procedure using a planar PET system / Kraan, A C (Pisa U. ; INFN, Pisa) ; Battistoni, G (INFN, Milan) ; Belcari, N (Pisa U. ; INFN, Pisa) ; Camarlinghi, N (Pisa U. ; INFN, Pisa) ; Ciocca, M (CNAO, Pavia) ; Ferrari, A (CERN) ; Ferretti, S (Pisa U. ; INFN, Pisa) ; Mairani, A (CNAO, Pavia) ; Molinelli, S (CNAO, Pavia) ; Pullia, M (CNAO, Pavia) et al.
In this study a procedure for range verification in proton therapy by means of a planar in-beam PET system is presented. The procedure consists of two steps: the measurement of the β+-activity induced in the irradiated body by the proton beam and the comparison of these distributions with simulations. [...]
2015 - Published in : Nucl. Instrum. Methods Phys. Res., A 786 (2015) 120-126 Elsevier Open Access article: PDF;
2.
INSIDE in-beam positron emission tomography system for particle range monitoring in hadrontherapy / Bisogni, Maria Giuseppina (U. Pisa (main)) ; Attili, Andrea (U. Turin (main)) ; Battistoni, Giuseppe (INFN, Italy) ; Belcari, Nicola (U. Pisa (main)) ; Camarlinghi, Niccoló (U. Pisa (main)) ; Cerello, Piergiorgio (INFN, Italy) ; Coli, Silvia (INFN, Italy) ; Del Guerra, Alberto (U. Pisa (main)) ; Ferrari, Alfredo (CERN) ; Ferrero, Veronica (U. Turin (main)) et al.
The quality assurance of particle therapy treatment is a fundamental issue that can be addressed by developing reliable monitoring techniques and indicators of the treatment plan correctness. Among the available imaging techniques, positron emission tomography (PET) has long been investigated and then clinically applied to proton and carbon beams. [...]
2016 - 12 p. - Published in : Journal of Medical Imaging 4 (2016) 011005
3.
Monitoring Proton Therapy Through in-Beam PET: An Experimental Phantom Study / Topi, A (INFN, Pisa) ; Muraro, S (INFN, Pisa) ; Battistoni, G (INFN, Milan) ; Belcari, N (INFN, Pisa ; Pisa U.) ; Bisogni, M G (INFN, Pisa ; Pisa U.) ; Camarlinghi, N (INFN, Pisa ; Pisa U.) ; Del Guerra, A (INFN, Pisa ; Pisa U.) ; Ferrari, A (CERN) ; Kopec, R (Cracow, INP) ; Kraan, A C (INFN, Pisa) et al.
In this paper, we investigate the use of a positron emission tomography (PET) system to monitor the proton therapy. The monitoring procedure is based on the comparison between the β+ activity generated in the irradiated volume during the treatment, with the β+ activity distribution obtained with Monte Carlo (MC) simulation. [...]
2020 - 8 p. - Published in : IEEE Trans. Rad. Plasma Med. Sci. 4 (2020) 194-201
4.
Proton therapy treatment monitoring with the DoPET system: activity range, positron emitters evaluation and comparison with Monte Carlo predictions / Muraro, S (Pisa U. ; INFN, Pisa) ; Battistoni, G (INFN, Milan) ; Belcari, N (Pisa U. ; INFN, Pisa) ; Bisogni, M G (Pisa U. ; INFN, Pisa) ; Camarlinghi, N (Pisa U. ; INFN, Pisa) ; Cristoforetti, L (Trento Hospital, Trento) ; Guerra, A Del (Pisa U. ; INFN, Pisa) ; Ferrari, A (CERN) ; Fracchiolla, F (Trento Hospital, Trento) ; Morrocchi, M (Pisa U. ; INFN, Pisa) et al.
Ion beam irradiations can deliver conformal dose distributions minimizing damage to healthy tissues thanks to their characteristic dose profiles. Nevertheless, the location of the Bragg peak can be affected by different sources of range uncertainties: a critical issue is the treatment verification. [...]
2017 - 10 p. - Published in : JINST 12 (2017) C12026
In : 19th International Workshop on Radiation Imaging Detectors, Krakow, Poland, 2 - 6 Jul 2017, pp.C12026
5.
Low statistics positron activity reconstruction methods for proton therapy / Muraro, S (Pisa U. ; INFN, Pisa) ; Camarlinghi, N (Pisa U. ; INFN, Pisa) ; Battistoni, G (INFN, Milan) ; Belcari, N (Pisa U. ; INFN, Pisa) ; Bisogni, M G (INFN, Pisa ; Pisa U.) ; Cristoforetti, L (Unlisted, IT) ; Del Guerra, A (Pisa U. ; INFN, Pisa) ; Ferrari, A (CERN) ; Fracchiolla, F (Unlisted, IT) ; Kraan, A (Pisa U. ; INFN, Pisa) et al.
Positron emission tomography (PET) is one of the most mature techniques for monitoring in ion beam therapy. PET allows to reconstruct the β$^{+}$ activity generated in the patient by the nuclear interaction of the ions. [...]
2019 - 2 p. - Published in : Nucl. Instrum. Methods Phys. Res., A 936 (2019) 52-53
In : Frontier Detectors for Frontier Physics: XIV Pisa Meeting on Advanced Detectors, La Biodola, Isola D'elba, Italy, 27 May - 2 Jun 2018, pp.52-53
6.
Ion charge separation with new generation of nuclear emulsion films / Montesi, M.C. (Naples U. ; INFN, Naples) ; Lauria, A. (Naples U. ; INFN, Naples) ; Alexandrov, A. (INFN, Naples ; Naples U. ; Natl. U. Sci. Tech., Moscow ; Lebedev Inst.) ; Solestizi, L. Alunni (INFN, Perugia ; Perugia U.) ; Giovanni, Ambrosi (INFN, Perugia) ; Argirò, S. (Turin U. ; INFN, Turin) ; Diaz, R. (Havana, CEADEN) ; Bartosik, N. (INFN, Turin) ; Battistoni, G. (INFN, Milan) ; Belcari, N. (Pisa U. ; INFN, Pisa) et al.
In hadron therapy, the accelerated ions, interacting with the body of the patient, cause the fragmentation of both projectile and target nuclei. The fragments interact with the human tissues depositing energy both in the entrance channel and in the volume surrounding the tumor. [...]
2019 - 8 p. - Published in : Open Physics 17 (2019) 233-240 Fulltext: PDF;
7.
The FOOT FragmentatiOn Of Target Experiment / Alexandrov, Andrey (INFN, Naples) ; Alpat, Behcet (INFN, Perugia) ; Ambrosi, Giovanni (INFN, Perugia) ; Argirò, Stefano (Turin U. ; INFN, Turin) ; Battistoni, Giuseppe (INFN, Milan) ; Bisogni, Maria Giuseppina (Pisa U. ; INFN, Pisa) ; Belcari, Nicola (Pisa U. ; INFN, Pisa) ; Biondi, Silvia (INFN, Bologna ; Bologna U.) ; Bruni, Graziano (INFN, Bologna) ; Camarlinghi, Niccolò (Pisa U. ; INFN, Pisa) et al.
In proton-therapy clinical practice a constant RBE equal to 1.1 is adopted, regardless of the demonstrated RBE variations, which depends on physical and biological parameters. Among other mechanisms, nuclear interactions might influence the proton-RBE due to secondary heavier particles produced by target fragmentation that can significantly contribute to the total dose: an un-wanted and undetermined increase of normal tissues complications probability may occur. [...]
Geneva : CERN, 2019 - 8 p. - Published in : CERN Proc.: 1 (2019) , pp. 305-312 Fulltext: PDF;
In : 15th International Conference on Nuclear Reaction Mechanisms, Varenna, Italy, 11 - 15 Jun 2018, pp.305-312
8.
Dosimetric accuracy of a treatment planning system for actively scanned proton beams and small target volumes: Monte Carlo and experimental validation / Magro, G (Pavia U. ; INFN, Pavia ; CNAO, Pavia) ; Molinelli, S (CNAO, Pavia) ; Mairani, A (CNAO, Pavia ; HIT, Heidelberg) ; Mirandola, A (CNAO, Pavia) ; Panizza, D (CNAO, Pavia) ; Russo, S (CNAO, Pavia) ; Ferrari, A (CERN) ; Valvo, F (CNAO, Pavia) ; Fossati, P (CNAO, Pavia ; Milan U.) ; Ciocca, M (CNAO, Pavia)
This study was performed to evaluate the accuracy of a commercial treatment planning system (TPS), in optimising proton pencil beam dose distributions for small targets of different sizes (5–30 mm side) located at increasing depths in water. The TPS analytical algorithm was benchmarked against experimental data and the FLUKA Monte Carlo (MC) code, previously validated for the selected beam-line. [...]
2015 - Published in : Phys. Med. Biol. 60 (2015) 6865-6880
9.
Measurement of $^{12}$C Fragmentation Cross Sections on C, O, and H in the Energy Range of Interest for Particle Therapy Applications / Mattei, I ; Alexandrov, A ; Alunni Solestizi, L ; Ambrosi, G ; Argiro, S ; Bartosik, N ; Battistoni, G ; Belcari, N ; Biondi, S ; Bisogni, M G et al.
In a carbon ion treatment the nuclear fragmentation of both target and beam projectiles impacts on the dose released on the tumor and on the surrounding healthy tissues. Carbon ion fragmentation occurring inside the patient body has to be studied in order to take into account this contribution. [...]
2020 - 14 p. - Published in : IEEE Trans. Rad. Plasma Med. Sci. 4 (2020) 269-282
10.
In-beam PET measurement of $^{7}Li^{3+}$ irradiation induced $\beta^+}$-activity / Priegnitz, M (Forschungszentrum Dresden Rossendorf) ; Möckel, D (Forschungszentrum Dresden Rossendorf) ; Parodi, K (Heidelberg Ion Therapy Center) ; Sommerer, F (CERN) ; Fiedler, F (Forschungszentrum Dresden Rossendorf) ; Enghardt, W (Forschungszentrum Dresden Rossendorf)
At present positron emission tomography (PET) is the only feasible method of an in situ and non-invasive monitoring of patient irradiation with ions. At the experimental carbon ion treatment facility of the Gesellschaft für Schwerionenforschung (GSI) Darmstadt an in-beam PET scanner has been integrated into the treatment site and lead to a considerable quality improvement of the therapy. [...]
2008 - Published in : Phys. Med. Biol. 53 (2008) 4443-4453

Nenašli ste čo ste hľadali? Skúste Vašu otázku na iných serveroch:
recid:2162741 v Amazon
recid:2162741 v CERN EDMS
recid:2162741 v CERN Intranet
recid:2162741 v CiteSeer
recid:2162741 v Google Books
recid:2162741 v Google Scholar
recid:2162741 v Google Web
recid:2162741 v IEC
recid:2162741 v IHS
recid:2162741 v INSPIRE
recid:2162741 v ISO
recid:2162741 v KISS Books/Journals
recid:2162741 v KISS Preprints
recid:2162741 v NEBIS
recid:2162741 v SLAC Library Catalog