CERN Accelerating science

CERN Document Server Encontrados 2,023 registros  1 - 10siguientefinal  ir al registro: La búsqueda tardó 0.43 segundos. 
1.
Union of light ion therapy centers in Europe (ULICE EC FP7) – Objectives and achievements of joint research activities / Pötter, Richard (Med. U. of Vienna, Spitalgasse) ; Balosso, Jaques (U. Grenoble Alpes ; Centre Hospitalier Universitaire Grenoble Alpes) ; Baumann, Michael (OncoRay, Dresden ; TU, Dresden (main) ; HZDR, Dresden ; DKTK, Dresden ; Heidelberg, Inst. Radiology) ; Bert, Christoph (U. Erlangen-Nuremberg (main)) ; Davies, Jim (U. Oxford (main)) ; Enghardt, Wolfgang (OncoRay, Dresden ; TU, Dresden (main) ; HZDR, Dresden ; DKTK, Dresden ; Heidelberg, Inst. Radiology) ; Fossati, Piero (EBG MedAustron GmbH, Wiener Neustadt) ; Harris, Steve (U. Oxford (main)) ; Jones, Bleddyn (U. Oxford (main)) ; Krämer, Michael (Darmstadt, GSI) et al. /ULICE
Under the umbrella of the European Network for Light Ion Therapy (ENLIGHT), the project on Union of Light Ion Centers in Europe (ULICE), which was funded by the European Commission (EC/FP7), was carried out from 2009 to 2014. Besides the two pillars on Transnational Access (TNA) and Networking Activities (NA), six work packages formed the pillar on Joint Research Activities (JRA). [...]
2018 - 18 p. - Published in : Radiotherapy Oncology 128 (2018) 83-100
2.
PROJECT ADMINISTRATION AGREEMENT K1496-TT-AB-007P-MedAustron / THE EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH, CERN ; EBG MedAustron GmbH, Austria
Agreement to invite PJAS
CERN-HR-Note-2013-004.
- 2008. - 20 p.
3.
The Beam Chopper Power Converter for MedAustron: Safety by Design and Development / Stadlbauer, Tobias ; Barnes, Michael (CERN) ; Beerwald, Moritz (Poynting GmbH, Dortmund) ; Dirksen, Uwe (Poynting GmbH, Dortmund) ; Filippini, Roberto (EBG MedAustron, Wr. Neustadt) ; German, Xavier (EBG MedAustron, Wr. Neustadt) ; Kramer, Thomas (CERN) ; Osmić, Fadmar (EBG MedAustron, Wr. Neustadt) ; Urschütz, Peter (EBG MedAustron, Wr. Neustadt)
MedAustron is the Austrian centre for hadron therapy and non-clinical research. The beam chopper system is an essential component for patient safety in specific hazardous situations as well as for beam delivery from the synchrotron to the irradiation rooms. [...]
CERN-ACC-2015-253.- 2015 - 3 p. - Published in : (2015) , pp. WEPMA002 Published version from JACoW: PDF; External link: JACOW
In : 6th International Particle Accelerator Conference, Richmond, VA, USA, 3 - 8 May 2015, pp.WEPMA002
4.
Commissioning the MedAustron Accelerator with ProShell / Moser, R (EBG MedAustron, Wr. Neustadt) ; Brett, A B (EBG MedAustron, Wr. Neustadt) ; Dorda, U (EBG MedAustron, Wr. Neustadt) ; Eichinger, M (EBG MedAustron, Wr. Neustadt) ; Hager, M (EBG MedAustron, Wr. Neustadt) ; Janulis, M (EBG MedAustron, Wr. Neustadt) ; Junuzovic, J (EBG MedAustron, Wr. Neustadt) ; Junuzovic, M (EBG MedAustron, Wr. Neustadt) ; Marchhart, M (EBG MedAustron, Wr. Neustadt) ; Pavetits, H (EBG MedAustron, Wr. Neustadt) et al.
MedAustron is a synchrotron-based centre for light ion therapy under construction in Austria..
2014 External link: Published version from JaCoW
In : 14th International Conference on Accelerator & Large Experimental Physics Control Systems, San Francisco, CA, USA, 6 - 11 Oct 2013, pp.moppc092
5.
Ion Sources for MedAustron / Lettry, J (CERN) ; Penescu, L (EBG MedAustron, Wiener Neustadt) ; Wallner, J (EBG MedAustron, Wiener Neustadt) ; Sargsyan, E (EBG MedAustron, Wiener Neustadt)
The MedAustron Ion therapy center will be constructed in Wiener Neustadt (Austria) in the vicinity of Vienna. Its accelerator complex consists of four ion sources, a linear accelerator, a synchrotron and a beam delivery system to the three medical treatment rooms and to the research irradiation room. [...]
CERN-BE-Note-2010-001.- Geneva : CERN, 2010 - 3 p. - Published in : Rev. Sci. Instrum. 81 (2010) 02A328 Access to fulltext: PDF;
In : International Conference on Ion Sources, Gatlinburg, TN, USA, 20 - 25 Sep 2009, pp.02A328
6.
Optimizing the modified microdosimetric kinetic model input parameters for proton and $^4$He ion beam therapy application / Mairani, A (CNAO, Milan ; Heidelberg Ion Beam Therapy Center, Heidelberg) ; Magro, G (CNAO, Milan) ; Tessonnier, T (Heidelberg U. Hospital ; LMU Munich (main)) ; Böhlen, T T (EBG MedAustron GmbH, Wiener Neustadt) ; Molinelli, S (CNAO, Milan) ; Ferrari, A (CERN) ; Parodi, K (Heidelberg Ion Beam Therapy Center, Heidelberg ; Heidelberg U. Hospital ; LMU Munich (main)) ; Debus, J (Heidelberg Ion Beam Therapy Center, Heidelberg ; Heidelberg U. Hospital) ; Haberer, T (Heidelberg Ion Beam Therapy Center, Heidelberg)
Models able to predict relative biological effectiveness (RBE) values are necessary for an accurate determination of the biological effect with proton and $^4$He ion beams. This is particularly important when including RBE calculations in treatment planning studies comparing biologically optimized proton and $^4$He ion beam plans. [...]
2017 - 13 p. - Published in : Phys. Med. Biol. 62 (2017) N244-N256
7.
AGREEMENT K1496 / The European Organisation for Nuclear Research, CERN ; EBG MedAustron GmbH, EBG
Agreement to invite Project Associates
CERN-HR-Note-2011-027.
- 2008. - 20 p.
Access to fulltext
8.
Medipix3 proton and carbon ion measurements across full energy ranges and at clinical flux rates in MedAustron IR1 / Bal, Navrit Johan Singh (Nikhef, Amsterdam ; CERN) ; Schmitzer, Claus Stefan (MedAustron) ; De Franco, Andrea (MedAustron) ; Enke, Sascha (MedAustron)
The Medipix3, a hybrid pixel detector with a silicon sensor, has been evaluated as a beam instrumentation device with proton and carbon ion measurements in the non-clinical research room (IR1) of MedAustron Ion Therapy Center. Protons energies are varied from 62.4 to 800 MeV with $10^{4}$ to $10^{8}$ protons per second impinging on the detector surface. [...]
arXiv:2108.01908.- 2021-12-01 - 20 p. - Published in : JINST 16 (2021) C12002 Fulltext: PDF;
In : 22nd International Workshop on Radiation Imaging Detectors, Online, 27 Jun - 1 Jul 2021, pp.C12002
9.
A Shielding Concept for the MedAustron Facility / Jägerhofer, L ; Feldbaumer, E (CERN) ; Roesler, S (CERN) ; Theis, C (CERN) ; Vincke, H (CERN)
MedAustron is a synchrotron based accelerator facility for cancer therapy and research in Wiener Neustadt, 50 km south of Vienna. The facility will provide protons up to kinetic energies of 250 MeV and carbon ions up to 400 MeV/n for ion beam therapy. [...]
2017 - 5 p. - Published in : EPJ Web Conf. 153 (2017) 04006 Fulltext: PDF;
In : 13th International Conference on Radiation Shielding & 19th Topical Meeting of the Radiation Protection & Shielding Division of the American Nuclear Society 2016, Paris, France, 3 - 6 Oct 2016, pp.04006
10.
Status of the Medaustron Ion Beam Therapy centre / Dorda, U (EBG MedAustron Austria) ; Fabich, A (EBG MedAustron Austria) ; Osmic, F (EBG MedAustron Austria) ; Benedikt, M (CERN)
MedAustron is a synchrotron based light-ion beam therapy centre for cancer treatment as well as for clinical and non-clinical research currently in its construction phase. The accelerator design is based on the CERN-PIMMS study and its technical implementation by CNAO. [...]
CERN-ATS-2012-109.- Geneva : CERN, 2012 - 3 p. - Published in : Conf. Proc.: C1205201 (2012) , pp. THPPR046
Fulltext: PDF; External link: Published version from JaCoW
In : 3rd International Particle Accelerator Conference, New Orleans, LA, USA, 20 - 25 May 2012, pp.4077

¿No ha encontrado lo que estaba buscando? Intente su búsqueda en:
recid:2632833 en Amazon
recid:2632833 en CERN EDMS
recid:2632833 en CERN Intranet
recid:2632833 en CiteSeer
recid:2632833 en Google Books
recid:2632833 en Google Scholar
recid:2632833 en Google Web
recid:2632833 en IEC
recid:2632833 en IHS
recid:2632833 en INSPIRE
recid:2632833 en ISO
recid:2632833 en KISS Books/Journals
recid:2632833 en KISS Preprints
recid:2632833 en NEBIS
recid:2632833 en SLAC Library Catalog