1.
|
Aging tests of full-scale CMS muon cathode strip chambers
/ Acosta, D (U. Florida, Gainesville (main)) ; Apollinari, G (Fermilab) ; Arisaka, K ; Bondar, N ; Breedon, R ; Bujak, A ; Bylsma, B ; Chester, N (Fermilab) ; Clare, R ; Cline, D et al.
Two CMS production Cathode Strip Chambers were tested for aging effects in a high-radiation environment at the Gamma Irradiation Facility at CERN. The chambers were irradiated over a large area: in total, about 2.1m**2 or 700m of wire in each chamber. [...]
FERMILAB-Conf-03-307.-
2003
- Published in : Nucl. Instrum. Methods Phys. Res., A 515 (2003) 226-233
In : International Workshop on Aging Phenomena in Gaseous Detectors, DESY, Hamburg, Germany, 2 - 5 Oct 2001, pp.226-233
|
|
2.
|
|
3.
|
Tests of Cathode Strip Chamber Prototypes
/ Bonushkin, Yuri (University of California Los Angeles, USA) ; Baarmand, Marc M (State Univ. of New York Brook, USA) ; Chrisman, David (University of California Riverside, USA) ; Durkin, S (Ohio State University, USA) ; Ferguson, Thomas (Carnegie Mellon University, USA) ; Giacomelli, Paolo (University of California Riverside, USA) ; Gorn, William (University of California Riverside, USA) ; Hauser, Jay (University of California Los Angeles, USA) ; Hirschfelder, J (Carnegie Mellon University, USA) ; Hoftiezer, John (Ohio State University, Columbus, USA) et al.
We report on the results of testing two six-layer 0.6 x 0.6 cm^2 cathode strip chamber ( CSC) prototypes in a muon beam at CERN. The prototypes were designed to simulate sections of the end-cap muon system of the Compact Muon Solenoid ( CMS) detector which will be installed at the Large Hadron Collider ( LHC). [...]
CMS-NOTE-1997-078.-
Geneva : CERN, 1997
Fulltext: PDF PS.Z;
|
|
4.
|
Six Layers P1 Cathode Strip Chamber Prototype (construction and first results)
/ Eartly, David P (FermiLab, Batavia, USA) ; Acosta, Darin (Ohio State University, Columbus, USA) ; Blomqvist, J M (FermiLab, Batavia, USA) ; Bondar, Nikolai (Carnegie-Mellon University, Pittsburgh, USA) ; Bonushkin, Yuri (University of California, Riverside, USA) ; Bonushkin, Yuri (University of California, Riverside, USA) ; Bujak, Adam (Purdue University, West Lafayette, USA) ; Bylsma, Ben (Ohio State University, Columbus, USA) ; Bylsma, Ben (Ohio State University, Columbus, USA) ; Durkin, S (Ohio State University, Columbus, USA) et al.
A full scale six layer Trapezoidal Cathode Strip Chamber Prototype of 0.8m x 1.2m x 3.3m was constructed and tested at Fermilab. The chamber construction and the first results on the chamber characteristics are presented in this paper..
CMS-NOTE-1997-011.-
Geneva : CERN, 1997
Fulltext: PDF PS.Z;
|
|
5.
|
|
Position and Timing Resolution of Interpolating Cathode Strip Chambers in a Test Beam
/ Gratchev, V ; Kiselev, O ; McCorkle, S ; Mohammadi, M ; O'Connor, P ; Polychronakos, V ; Prokofiev, O E ; Radeka, V ; Shank, J T ; Smith, G et al.
Design and construction details are presented of a four-layer, position sensitive, cathode strip chamber and a low cost, highly multiplexed readout system based on monolithic circuit technology that are well suited for a muon detector at future hadron colliders. [...]
ATL-MUON-94-055 ; ATL-M-PN-55.
-
1994. - 15 p.
Full text - Access to fulltext document
|
|
6.
|
Large CMS cathode strip chambers : design and performance
/ Acosta, D ; Apollinari, G ; Blomqvist, J M ; Breedon, R ; Bondar, N F ; Bonushkin, Yu ; Borissov, E ; Bujak, A T ; Bylsma, B ; Chester, N S et al.
Presented are the main design features of the large cathode strip chambers (CSCs) for the CMS endcap muon system as well as the performance results obtained with the two full-scale 3.4 * 1.5 m/sup 2/ six-plane prototypes. The prototype performance was within the baseline requirements: (a) higher than 99% efficiency of muon track finding at the trigger level with more than 92% probability for bunch crossing identification and better than 2 mm spatial resolution, and (b) better than 150 mu m spatial resolution in off-line. [...]
2000
- Published in : Nucl. Instrum. Methods Phys. Res., A 453 (2000) 182-7
In : 7th International Conference on Instrumentation for Colliding Beam Physics, Hamamatsu, Japan, 15 - 19 Nov 1999, pp.182-187
|
|
7.
|
Large cathode strip chambers for the CMS endcap muon system
/ Acosta, D ; Blomqvist, J M ; Bondar, N F ; Bonushkin, Yu ; Bujak, A T ; Bylsma, B G ; Chrisman, D ; Durkin, S ; Eartly, D P ; Ferguson, T et al.
1998
- Published in : Nucl. Instrum. Methods Phys. Res., A 419 (1998) 469-74
|
|
8.
|
Tests of cathode strip chamber prototypes
/ Baarmand, M M ; Bonushkin, Yu ; Chrisman, D ; Durkin, S ; Ferguson, T ; Giacomelli, P ; Gorn, L ; Gorn, W ; Hauser, J ; Hirschfelder, J et al.
1998
- Published in : Nucl. Instrum. Methods Phys. Res., A 402 (1998) 36-52
|
|
9.
|
Study of the deuteron structure in quasi-elastic break-up reaction $pd \to ppn$ at 1 GeV
/ Aleshin, N P ; Belostotskii, S ; Grebenyuk, O ; Gordeev, V A ; Komarov, E N ; Kochenda, L M ; Lasarev, V I ; Manayenkov, S I ; Miklukho, O ; Nelyubin, V V et al.
Dapnia-SPhN-93-03.
-
1993. - 29 p.