1.
|
Impact of magnetic field on the stability of the CMS GE1/1 GEM detector operation
/ Abbas, M (KIT, Karlsruhe) ; Abbott, S (UC, Davis) ; Abbrescia, M (Bari U. ; INFN, Bari) ; Abdalla, H (Alexandria U. ; American U., Cairo) ; Abdelalim, A (Alexandria U. ; Zewail City Sci. Technol., Giza) ; AbuZeid, S (Ain Shams U., Cairo ; INFN, Pavia) ; Aebi, D (Texas A-M) ; Agapitos, A (Peking U.) ; Ahmad, A (NCP, Islamabad) ; Ahmed, A (Delhi Tech. U.) et al.
The Gas Electron Multiplier (GEM) detectors of the GE1/1 station of the CMS experiment have been operated in the CMS magnetic field for the first time on the 7$^{th}$ of October 2021. During the magnetic field ramps, several discharge phenomena were observed, leading to instability in the GEM High Voltage (HV) power system. [...]
2023 - 24 p.
- Published in : JINST 18 (2023) P11029
Fulltext: PDF;
|
|
2.
|
|
3.
|
Production and validation of industrially produced large-sized GEM foils for the Phase-2 upgrade of the CMS muon spectrometer
/ Abbas, Syed Mohsin (IPM, Tehran) ; Abbrescia, Marcello (INFN, Bari ; Bari U.) ; Abdalla, Hassan Fathy (Cairo, Acad. Sci. Res. Tech.) ; Abdelalim, Ahmed Ali (Cairo, Acad. Sci. Res. Tech.) ; Abuzeid Hassan, Shimaa Abdelwahed (INFN, Pavia) ; Aebi, Devin Michael (Texas A-M) ; Agapitos, Antonis (Peking U.) ; Ahmad, Ashfaq (Quaid-i-Azam U.) ; Ahmed, Asar (Delhi U.) ; Ahmed, Waqar (Quaid-i-Azam U.) et al.
The upgrade of the CMS detector for the high luminosity LHC (HL-LHC) will include gas electron multiplier (GEM) detectors in the end-cap muon spectrometer.
Due to the limited supply of large area GEM detectors, the Korean CMS (KCMS) collaboration had formed a consortium with Mecaro Co., Ltd. to serve as a supplier of GEM foils with area of approximately 0.6 m$^{2}$.
The consortium has developed a double-mask etching technique for production of these large-sized GEM foils.
This article describes the production, quality control, and quality assessment (QA/QC) procedures and the mass production status for the GEM foils. [...]
CMS-NOTE-2023-006; CERN-CMS-NOTE-2023-006.-
Geneva : CERN, 2023 - 18 p.
Fulltext: PDF;
|
|
4.
|
Quality control of mass-produced GEM detectors for the CMS GE1/1 muon upgrade
/ Abbas, M. (KIT, Karlsruhe) ; Abbrescia, M. (Bari Polytechnic ; INFN, Bari) ; Abdalla, H. (Ain Shams U., Cairo ; American U., Cairo) ; Abdelalim, A. (Ain Shams U., Cairo ; British U. in Egypt) ; AbuZeid, S. (Ain Shams U., Cairo) ; Agapitos, A. (Peking U.) ; Ahmad, A. (NCP, Islamabad) ; Ahmed, A. (Delhi Tech. U.) ; Ahmed, W. (NCP, Islamabad) ; Aimè, C. (Pavia U. ; INFN, Pavia) et al.
The series of upgrades to the Large Hadron Collider, culminating in the High Luminosity Large Hadron Collider, will enable a significant expansion of the physics program of the CMS experiment. However, the accelerator upgrades will also make the experimental conditions more challenging, with implications for detector operations, triggering, and data analysis. [...]
arXiv:2203.12037.-
2022-07-01 - 45 p.
- Published in : Nucl. Instrum. Methods Phys. Res., A 1034 (2022) 166716
Fulltext: PDF;
|
|
5.
|
Quality Control of Mass-Produced GEM Detectors for the CMS GE1/1 Muon Upgrade
/ Abbas, Syed Mohsin (IPM, Tehran) ; Abbrescia, Marcello (INFN, Bari ; Bari U.) ; Abdalla, Hassan Fathy (Cairo, Acad. Sci. Res. Tech.) ; Abdelalim, Ahmed Ali (Cairo, Acad. Sci. Res. Tech.) ; Abuzeid Hassan, Shimaa Abdelwahed (INFN, Pavia) ; Agapitos, Antonis (Peking U.) ; Ahmad, Ashfaq (Quaid-i-Azam U.) ; Ahmed, Asar (Delhi U.) ; Ahmed, Waqar (Quaid-i-Azam U.) ; Aimè, Chiara (INFN, Pavia ; Pavia U.) et al.
The series of upgrades to the Large Hadron Collider, culminating in the High Luminosity Large Hadron Collider, will enable a significant expansion of the physics program of the CMS experiment. However, the accelerator upgrades will also make the experimental conditions more challenging, with implications for detector operations, triggering, and data analysis. [...]
CMS-NOTE-2022-004; CERN-CMS-NOTE-2022-004.-
Geneva : CERN, 2022 - 47 p.
Fulltext: PDF;
|
|
6.
|
Performance of a triple-GEM demonstrator in pp collisions at the CMS detector
/ Abbas, M. (KIT, Karlsruhe) ; Abbrescia, M. (Bari U. ; INFN, Bari) ; Abdalla, H. (Ain Shams U., Cairo ; American U., Cairo) ; Abdelalim, A. (Ain Shams U., Cairo ; Zewail City Sci. Technol., Giza) ; AbuZeid, S. (Ain Shams U., Cairo) ; Agapitos, A. (Peking U.) ; Ahmad, A. (NCP, Islamabad) ; Ahmed, A. (Delhi U.) ; Ahmed, W. (NCP, Islamabad) ; Aimè, C. (INFN, Pavia) et al.
After the Phase-2 high-luminosity upgrade to the Large Hadron Collider (LHC), the collision rate and therefore the background rate will significantly increase, particularly in the high $\eta$ region. To improve both the tracking and triggering of muons, the Compact Muon Solenoid (CMS) Collaboration plans to install triple-layer Gas Electron Multiplier (GEM) detectors in the CMS muon endcaps. [...]
arXiv:2107.09364.-
2021-11-12 - 10 p.
- Published in : JINST 16 (2021) P11014
Fulltext: 2107.09364 - PDF; document - PDF;
|
|
7.
|
Benchmarking LHC background particle simulation with the CMS triple-GEM detector
/ CMS Collaboration
An estimate of environmental background hit rate on triple-GEM chambers is performed using Monte Carlo (MC) simulation and compared to data taken by test chambers installed in the CMS experiment (GE1/1) during Run-2 at the Large Hadron Collider (LHC). The hit rate is measured using data collected with proton-proton collisions at 13 TeV and a luminosity of 1.5$\times10^{34}$ cm$^{-2}$ s$^{-1}$. [...]
arXiv:2107.03621.-
2021-12-16 - 19 p.
- Published in : JINST 16 (2021) P12026
Fulltext: 2107.03621 - PDF; document - PDF;
|
|
8.
|
|
9.
|
Triple-GEM discharge probability studies at CHARM: simulations and experimental results
/ CMS Muon Group Collaboration
The CMS muon system in the region with 2.03<|η|<2.82 is characterized by a very harsh radiation environment which can generate hit rates up to 144 kHz/cm2 and an integrated charge of 8 C/cm2 over ten years of operation. In order to increase the detector performance and acceptance for physics events including muons, a new muon station (ME0) has been proposed for installation in that region. [...]
2020 - 23 p.
- Published in : JINST 15 (2020) P10013
Fulltext: PDF;
|
|
10.
|
Interstrip Capacitances of the Readout Board used in Large Triple-GEM Detectors for the CMS Muon Upgrade
/ CMS Muon Group Collaboration
We present analytical calculations, Finite Element Analysis modeling, and physical measurements of the interstrip capacitances for different potential strip geometries and dimensions of the readout boards for the GE2/1 triple-Gas Electron Multiplier detector in the CMS muon system upgrade. The main goal of the study is to find configurations that minimize the interstrip capacitances and consequently maximize the signal-to-noise ratio for the detector. [...]
arXiv:2009.09505.-
2020-12-14 - 21 p.
- Published in : JINST 15 (2020) P12019
Fulltext: PDF; Fulltext from publisher: PDF;
|
|