CERN Accelerating science

CERN Document Server 10 záznamov nájdených  Hľadanie trvalo 0.57 sekúnd. 
1.
Interactive image segmentation of MARS datasets using bag of features / Kanithi, Praveenkumar (Canterbury U.) ; de Ruiter, Niels J A (Canterbury U. ; Otago U. ; MARS Bioimaging) ; Amma, Maya R (Otago U.) ; Lindeman, Robert W (Canterbury U.) ; Butler, Anthony P H (Canterbury U. ; MARS ; Otago U. ; CERN) ; Butler, Philip H (Canterbury U. ; MARS Bioimaging ; Otago U. ; CERN) ; Chernoglazov, Alexander I (Canterbury U. ; MARS Bioimaging) ; Mandalika, V B H (Canterbury U. ; MARS Bioimaging) ; Adebileje, Sikiru A (Canterbury U. ; Otago U.) ; Alexander, Steven D (MARS Bioimaging) et al.
In this paper, we propose a slice-based interactive segmentation of spectral CT datasets using a bag of features method. The data is acquired from a MARS scanner which divides up the x-ray spectrum into multiple energy bins for imaging. [...]
2021 - 9 p. - Published in : IEEE Trans. Rad. Plasma Med. Sci. 5 (2021) 559 - 567
2.
Assessment of material identification errors, image quality and radiation doses using small animal spectral photon-counting CT / MARS Collaboration
Photon-counting CT offers the potential to provide new diagnostic information. In this study, we sought to determine the interplay between material identification errors, image quality indicators, and radiation doses using photon-counting spectral CT, and to determine whether this relationship is replicated in spectral CT scans of mice. [...]
2021 - 10 p. - Published in : IEEE Trans. Rad. Plasma Med. Sci. 5 (2021) 578 - 587
3.
Eye lens monitoring programme for medical staff involved in fluoroscopy guided interventional procedures in Switzerland / Sans-Merce, Marta (Lausanne U. Hospital, Inst. Radiat. Phys. ; Geneva U. Hospital) ; Lemesre, Camille (Lausanne U. Hospital, Inst. Radiat. Phys.) ; Elmiger, Raphael (FOPH, Bern) ; Damet, Jérôme (CERN ; Lausanne U. Hospital, Inst. Radiat. Phys. ; U. Otago, Dept. Radiol.)
Epidemiological studies indicate that radiation damages to the eye lens occurs at lower dose values than previously considered (Worgul et al., 2007; Chodick et al., 2008; Ciraj-Bjelac et al., 2010; Rehani et al., 2011; Vano et al., 2010) [1], [2], [3], [4], [5]. The International Commission on Radiological Protection lowered the equivalent dose limit value for the eye lens to 20 mSv/year (ICRP, n.d.) [6]. [...]
2019 - 8 p. - Published in : Physica Medica 57 (2019) 33-40
4.
Impact of the phantom geometry on the evaluation of the minimum detectable activity following a radionuclide intake: From physical to numerical phantoms / Medici, Siria (CERN ; Lausanne U.) ; Desorgher, Laurent (Lausanne U.) ; Carbonez, Pierre (CERN ; Otago U.) ; Damet, Jérôme (Lausanne U. ; Otago U.) ; Bochud, François (Lausanne U.) ; Pitzschke, Andreas (Lausanne U.)
The establishment of an in vivo internal monitoring programme requires the use of phantoms to represent an activity distribution of an incorporated radionuclide within the body. The aim of this study was to quantify the impact of the phantom geometry on the minimum detectable activity (MDA) of an incorporated radionuclide. [...]
2020 External link: Fulltext from publisher
5.
Use of portable gamma spectrometers for triage monitoring following the intake of conventional and novel radionuclides / Medici, Siria (CERN ; Lausanne U.) ; Carbonez, Pierre (CERN ; U. Otago, Dept. Radiol.) ; Damet, Jérôme (Lausanne U. ; U. Otago, Dept. Radiol.) ; Bochud, François (Lausanne U.) ; Pitzschke, Andreas (Lausanne U.)
Current internal dosimetry monitoring programmes generally feature periodic measurements that are defined for the most commonly-encountered radionuclides. These programmes are not directly applicable to research centres that produce novel and short-lived radionuclides which are then used for the manufacture of radiopharmaceuticals, such as the CERN-MEDICIS facility hosted at CERN. [...]
2020 - 8 p. - Published in : Radiat. Meas. 136 (2020) 106426 Fulltext: PDF;
In : The Medipix/Timepix ASIC family and its applications, pp.106426
6.
Medipix3RX neutron camera for ambient radiation measurements in the CMS cavern / Bheesette, Srinidhi (Otago U. ; CERN) ; Lokhovitskiy, Arkady (CERN) ; Mallows, Sophie (CERN) ; Walsh, Michael F (MARS Bioimaging) ; Doesburg, Robert M N (MARS Bioimaging) ; Bell, Stephen T (MARS Bioimaging) ; Dabrowski, Anne (CERN) ; Butler, Anthony P H (Otago U. ; CERN ; MARS Bioimaging ; Canterbury U.) ; Butler, Philip H (Otago U. ; CERN ; MARS Bioimaging ; Canterbury U.) ; Adebileje, Sikiru A (Otago U.) et al.
We describe a CMS-Medipix3RX neutron camera developed by adapting and modifying detector readout electronics developed at the University of Canterbury. The readout electronics are part of the MARS x-ray scanner used for imaging applications [1]. [...]
2019 - 6 p. - Published in : 10.1109/NSSMIC.2018.8824390
In : 2018 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC 2018), Sydney, Australia, 10 - 17 Nov 2018, pp.8824390
7.
Assessment of metal implant induced artefacts using photon counting spectral CT / Amma, Maya Rajeswari (Otago U.) ; Butler, Anthony P H (MARS Bioimaging ; Canterbury U. ; Otago U.) ; Raja, Aamir Y (Otago U.) ; Bamford, Benjamin (Otago U.) ; Butler, Philip (MARS Bioimaging ; Canterbury U. ; Otago U.) ; Walker, E Peter (Otago U.) ; Matanaghi, Aysouda (Otago U.) ; Adebileje, Sikiru A (Otago U. ; Canterbury U.) ; Anderson, Nigel (Otago U.) ; Anjomrouz, Marzieh (MARS Bioimaging) et al.
The aim is to perform qualitative and quantitative assessment of metal induced artefacts of small titanium biomaterials using photon counting spectral CT. The energy binning feature of some photon counting detectors enables the measured spectrum to be segmented into low, mid and high energy bins in a single exposure. [...]
2019 - 8 p. - Published in : Proc. SPIE 11113 (2019) 111131D
In : Developments in X-Ray Tomography XII, San Diego, CA, United States, 11 - 15 Aug 2019, pp.111131D
8.
MARS pre-clinical imaging: the benefits of small pixels and good energy data / Butler, Philip H (MARS Bioimaging ; Canterbury U. ; Otago U.) ; Adebileje, Sikiru A (Otago U. ; Canterbury U.) ; Alexander, Steven D (MARS Bioimaging) ; Amma, Maya R (Otago U.) ; Amjomrouz, Marzieh (MARS Bioimaging) ; Asghariomabad, Fatemeh (Otago U.) ; Atharifard, Ali (MARS Bioimaging) ; Atlas, James (Canterbury U.) ; Bamford, Benjamin (Otago U.) ; Bell, Stephen T (MARS Bioimaging) et al.
Images from MARS spectral CT scanners show that there is much diagnostic value from using small pixels and good energy data. MARS scanners use energy-resolving photon-counting CZT Medipix3RX detectors that measure the energy of photons on a five-point scale and with a spatial resolution of 110 microns. [...]
2019 - Published in : Proc. SPIE 11113 (2019) 111130C
In : Developments in X-Ray Tomography XII, San Diego, CA, United States, 11 - 15 Aug 2019, pp.111130C
9.
Dosimetry in MARS spectral CT: TOPAS Monte Carlo simulations and ion chamber measurements / Lu, Gray (Canterbury U.) ; Marsh, Steven (Canterbury U.) ; Damet, Jerome (CERN ; Lausanne University Hospital, Lausanne ; U. Otago, Dept. Radiol.) ; Carbonez, Pierre (CERN ; U. Otago, Dept. Radiol.) ; Laban, John (National Centre for Radiation Science, Christchurch) ; Bateman, Christopher (Canterbury U. ; U. Otago, Dept. Radiol. ; MARS Bioimaging) ; Butler, Anthony (U. Otago, Dept. Radiol. ; MARS Bioimaging) ; Butler, Phil (Canterbury U. ; MARS Bioimaging)
Spectral computed tomography (CT) is an up and coming imaging modality which shows great promise in revealing unique diagnostic information. Because this imaging modality is based on X-ray CT, it is of utmost importance to study the radiation dose aspects of its use. [...]
2017 - 7 p. - Published in : Australasian Physical & Engineering Sciences in Medicine 40 (2017) 297-303
10.
Three-dimensional visualisation of tracks in OPERA nuclear emulsion films / Damet, Jerome (Annecy, LAPP) ; Pereiro Lopez, Eva (ESRF, Grenoble) ; Sasov, Alexander
The possibility of a three-dimensional visualisation/reconstruction of tracks in nuclear emulsion films using X-ray imaging is described in this paper. [...]
physics/0509262.
- 2005. - 8 p.
Access to fulltext document - Access to fulltext document - Full text

Viď tiež: podobné mená autorov
18 Damet, J
1 Damet, J A
9 Damet, J.
10 Damet, Jerome
Prajete si byť pravidelne informovaný o výsledkoch tohto hľadania?
Založte si osobný email alert alebo použite RSS feed.
Nenašli ste čo ste hľadali? Skúste Vašu otázku na iných serveroch:
Damet, Jérôme v Amazon
Damet, Jérôme v CERN EDMS
Damet, Jérôme v CERN Intranet
Damet, Jérôme v CiteSeer
Damet, Jérôme v Google Books
Damet, Jérôme v Google Scholar
Damet, Jérôme v Google Web
Damet, Jérôme v IEC
Damet, Jérôme v IHS
Damet, Jérôme v INSPIRE
Damet, Jérôme v ISO
Damet, Jérôme v KISS Books/Journals
Damet, Jérôme v KISS Preprints
Damet, Jérôme v NEBIS
Damet, Jérôme v SLAC Library Catalog
Damet, Jérôme v Scirus