CERN Accelerating science

CERN Document Server 1,385 записей найдено  1 - 10следующийконец  перейти к записи: Поиск длился 0.68 секунд. 
1.
Measurement of the background in the CMS muon detector in ${p}{p}$-collisions at $\sqrt{s} = 13$ $\,\text {Te}\hspace{-.08em}\text {V}$ / CMS Muon Collaboration
The CMS detector, including its muon system, has been operating at the CERN LHC in increasingly challenging conditions for about 15 years. The muon detector was designed to provide excellent triggering and track reconstruction for muons produced in proton–proton collisons at an instantaneous luminosity ($\mathcal {L}$) of $1 \times 10^{34}$ cm$^{-2}$s$^{-1}$. [...]
2024 - 43 p. - Published in : Eur. Phys. J. C 84 (2024) 955 Fulltext: PDF;
2.
Irradiation aging of the CMS Drift Tube muon detector / Ferrero, D.D. Redondo ; Abbiendi, G. ; Maestre, J. Alcaraz ; Fernández, A. Álvarez ; González, B. Álvarez ; Amapane, N. ; Bachiller, I. ; Barcala, J.M. ; Barcellan, L. ; Battilana, C. et al.
During the High Luminosity LHC, the Drift Tube chambers installed in the CMS detector need to operate with an integrated dose ten times higher than expected at the LHC due to the increase in integrated luminosity from 300 fb${-1}$ to 3000 fb$^{-1}$. Irradiations have been performed to assess the performance of the detector under such conditions and to characterize the radiation aging of the detector. [...]
2020 - 6 p. - Published in : Radiat. Phys. Chem. 172 (2020) 108747
In : 3rd International Conference on Dosimetry and its Applications, Lisbon, Portugal, 27 - 31 May 2019, pp.108747
3.
Study of central exclusive $\pi^{+}\pi^{-}$ production in proton-proton collisions at $\sqrt{s} = $ 5.02 and 13 TeV / CMS Collaboration
Central exclusive production of $\pi^{+}\pi^{-}$ pairs is measured with the CMS detector in proton-proton collisions at the LHC at center-of-mass energies of 5.02 and 13 TeV. The theoretical description of these nonperturbative processes, which have not yet been measured in detail at the LHC, poses a significant challenge to models. [...]
arXiv:2003.02811; CMS-FSQ-16-006; CERN-EP-2020-005; CMS-FSQ-16-006-003.- Geneva : CERN, 2020-08-10 - 28 p. - Published in : Eur. Phys. J. C 80 (2020) 718 Article from SCOAP3: PDF; Fulltext: PDF; Fulltext from Publisher: PDF; External links: Additional information for the analysis; CMS AuthorList
4.
Measurement of single-diffractive dijet production in proton-proton collisions at $\sqrt{s} =$ 8 TeV with the CMS and TOTEM experiments / CMS and TOTEM Collaborations
Measurements are presented of the single-diffractive dijet cross section and the diffractive cross section as a function of the proton fractional momentum loss $\xi$ and the four-momentum transfer squared $t$. Both processes ${\mathrm{p}}{\mathrm{p}} \to {\mathrm{p}}\mathrm{X}$ and ${\mathrm{p}}{\mathrm{p}} \to \mathrm{X}{\mathrm{p}}$, ie with the proton scattering to either side of the interaction point, are measured, where $\mathrm{X}$ includes at least two jets; the results of the two processes are averaged [...]
arXiv:2002.12146; CMS-FSQ-12-033; TOTEM-2020-001; CERN-EP-2019-260; CMS-FSQ-12-033-003.- Geneva : CERN, 2020-12-17 - 42 p. - Published in : Eur. Phys. J. C Article from SCOAP3: PDF; Fulltext: PDF; External links: Additional information for the analysis; CMS AuthorList
5.
Motion of CMS detector and mechanical structures during Magnet Cycles and Stability Periods from 2008 to 2013 as observed by the Link Alignment System / Arce, P (Madrid, CIEMAT) ; Barcala, J M (Madrid, CIEMAT) ; Calvo, E (Madrid, CIEMAT) ; Ferrando, A (Madrid, CIEMAT) ; Josa, M I (Madrid, CIEMAT) ; Molinero, A (Madrid, CIEMAT) ; Navarrete, J (Madrid, CIEMAT) ; Oller, J C (Madrid, CIEMAT) ; Brochero, J (Cantabria U., Santander) ; Calderón, A (Cantabria U., Santander) et al.
Magnet Cycles and Stability Periods of the CMS Experiment are studied with the Alignment Link System data recorded along the 2008–2013 years of operation. The motions of the mechanical structures due to the magnetic field forces are studied and the mechanical stability of the detector during the physics data taking periods is verified..
Elsevier, 2016 - 20 p. - Published in : Nucl. Instrum. Methods Phys. Res., A 813 (2016) 36-55
6.
Measurements of dose-rate effects in the radiation damage of plastic scintillator tiles using silicon photomultipliers / CMS Collaboration
Measurements are presented of the reduction of signal output due to radiation damage for plastic scintillator tiles used in the hadron endcap (HE) calorimeter of the CMS detector. The tiles were exposed to particles produced in proton-proton (pp) collisions at the CERN LHC with a center-of-mass energy of 13 TeV, corresponding to a delivered luminosity of 50 fb$^{-1}$. [...]
arXiv:2001.06553; CMS-PRF-18-003; CERN-EP-2019-266; CMS-PRF-18-003-003.- Geneva : CERN, 2020-06-08 - 47 p. - Published in : JINST 15 (2020) P06009 Fulltext: PDF; Fulltext from Publisher: PDF; External links: Additional information for the analysis; CMS AuthorList
7.
Search for an excited lepton that decays via a contact interaction to a lepton and two jets in proton-proton collisions at ${\sqrt{s}} = $ 13 TeV / CMS Collaboration
Results are presented from a search for events containing an excited lepton (electron or muon) produced in association with an ordinary lepton of the same flavor and decaying to a lepton and two hadronic jets. Both the production and the decay of the excited leptons are assumed to occur via a contact interaction with a characteristic energy scale $\Lambda$. [...]
arXiv:2001.04521; CMS-EXO-18-013; CERN-EP-2019-280; CMS-EXO-18-013-004.- Geneva : CERN, 2020-05-12 - 20 p. - Published in : JHEP 2005 (2020) 052 Article from SCOAP3: PDF; Fulltext: PDF; External links: Additional information for the analysis; CMS AuthorList
8.
Study of the effects of radiation on the CMS Drift Tubes Muon Detector for the HL-LHC / Abbiendi, G. (INFN, Bologna) ; Alcaraz Maestre, J. (Madrid, CIEMAT) ; Álvarez Fernández, A. (Madrid, CIEMAT) ; Álvarez González, B. (ICTEA, Oviedo) ; Amapane, N. (INFN, Turin ; Turin U.) ; Bachiller, I. (Madrid, CIEMAT) ; Barcala, J.M. (Madrid, CIEMAT) ; Barcellan, L. (INFN, Padua) ; Battilana, C. (INFN, Bologna ; U. Bologna (main)) ; Bellato, M. (INFN, Padua) et al. /CMS Muon group
The CMS drift tubes (DT) muon detector, built for withstanding the LHC expected integrated and instantaneous luminosities, will be used also in the High Luminosity LHC (HL-LHC) at a 5 times larger instantaneous luminosity and, consequently, much higher levels of radiation, reaching about 10 times the LHC integrated luminosity. Initial irradiation tests of a spare DT chamber at the CERN gamma irradiation facility (GIF++), at large ($\sim$O(100)) acceleration factor, showed ageing effects resulting in a degradation of the DT cell performance. [...]
arXiv:1912.06178; CMS CR-2019/159.- Geneva : CERN, 2019-12-11 - 10 p. - Published in : JINST
Fulltext: CR2019_159 - PDF; 1912.06178 - PDF;
In : 21st International Workshop on Radiation Imaging Detectors, Kolympari, Chania, Greece, 7 - 12 Jul 2019, pp.C12010
9.
Search for a heavy Higgs boson decaying to a pair of W bosons in proton-proton collisions at $\sqrt{s} =$ 13 TeV / CMS Collaboration
A search for a heavy Higgs boson in the mass range from 0.2 to 3.0 TeV, decaying to a pair of W bosons, is presented. The analysis is based on proton-proton collisions at $\sqrt{s} = $ 13 TeV recorded by the CMS experiment at the LHC in 2016, corresponding to an integrated luminosity of 35.9 fb$^{-1}$. [...]
arXiv:1912.01594; CMS-HIG-17-033; CERN-EP-2019-230; CMS-HIG-17-033-004.- 2020-03-06 - 49 p. - Published in : JHEP 2003 (2020) 034 Article from SCOAP3: PDF; Fulltext: PDF; Fulltext from publisher: PDF; External links: Additional information for the analysis; CMS AuthorList
10.
Search for lepton flavour violating decays of a neutral heavy Higgs boson to $\mu\tau$ and e$\tau$ in proton-proton collisions at $\sqrt{s}=$ 13 TeV / CMS Collaboration
A search for lepton flavour violating decays of a neutral non-standard-model Higgs boson in the $\mu\tau$ and e$\tau$ decay modes is presented. The search is based on proton-proton collisions at a center of mass energy $\sqrt{s}=$ 13 TeV collected with the CMS detector in 2016, corresponding to an integrated luminosity of 35.9 fb$^{-1}$ . [...]
arXiv:1911.10267; CMS-HIG-18-017; CERN-EP-2019-170; CMS-HIG-18-017-003.- Geneva : CERN, 2020-03-18 - 50 p. - Published in : JHEP 2003 (2020) 103 Article from SCOAP3: PDF; Fulltext: PDF; Fulltext from Publisher: PDF; External links: Additional information for the analysis; Fulltext from publisher; CMS AuthorList

CERN Document Server : 1,385 записей найдено   1 - 10следующийконец  перейти к записи:
Смотрите также: похожие имена автора
49 Benvenuti, A C
82 Benvenuti, A.
1 Benvenuti, A. C.
1 Benvenuti, A.C
54 Benvenuti, A.C.
998 Benvenuti, Alberto
303 Benvenuti, Alberto C
Вы хотите получать уведомление о новых документах, соотетствующих этому запросу?
Установите персональное email оповещение или подпишитесь на RSS-канал.
не нашли то, что искали? Попробуйте поискать на других серверах
Benvenuti, A в Amazon
Benvenuti, A в CERN EDMS
Benvenuti, A в CERN Intranet
Benvenuti, A в CiteSeer
Benvenuti, A в Google Books
Benvenuti, A в Google Scholar
Benvenuti, A в Google Web
Benvenuti, A в IEC
Benvenuti, A в IHS
Benvenuti, A в INSPIRE
Benvenuti, A в ISO
Benvenuti, A в KISS Books/Journals
Benvenuti, A в KISS Preprints
Benvenuti, A в NEBIS
Benvenuti, A в SLAC Library Catalog
Benvenuti, A в Scirus