1.
|
|
PICOSEC Micromegas Precise-timing Detectors: Development towards Large-Area and Integration
/ Meng, Y. (USTC, Hefei ; Hefei, CUST) ; Aleksan, R. (IRFU, Saclay) ; Angelis, Y. (Aristotle U., Thessaloniki) ; Bortfeld, J. (LMU Munich (main)) ; Brunbauer, F. (CERN) ; Brunoldi, M. (Pavia U. ; INFN, Pavia) ; Chatzianagnostou, E. (Aristotle U., Thessaloniki) ; Datt, J. (SUNY, Stony Brook) ; Degmelt, K. (CERN) ; Fanourakis, G. (Democritos Nucl. Res. Ctr.) et al.
PICOSEC Micromegas (MM) is a precise timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and an MM amplifying structure. [...]
arXiv:2501.04991.
-
9.
Fulltext
|
|
2.
|
|
3.
|
PICOSEC-Micromegas Detector, an innovative solution for Lepton Time Tagging
/ Kallitsopoulou, A. (IRFU, Saclay) ; Aleksan, R. (IRFU, Saclay) ; Angelis, Y. (Aristotle U., Thessaloniki) ; Aune, S. (IRFU, Saclay) ; Bortfeldt, J. (Munich U.) ; Brunbauer, F. (CERN) ; Brunoldi, M. (Pavia U. ; INFN, Pavia) ; Chatzianagnostou, E. (Aristotle U., Thessaloniki) ; Datta, J. (SUNY, Stony Brook) ; Desforge, D. (IRFU, Saclay) et al.
The PICOSEC-Micromegas (PICOSEC-MM) detector is a novel gaseous detector designed for precise timing resolution in experimental measurements. It eliminates time jitter from charged particles in ionization gaps by using extreme UV Cherenkov light emitted in a crystal, detected by a Micromegas photodetector with an appropriate photocathode. [...]
arXiv:2411.02532; FERMILAB-PUB-24-0980-CMS-V.-
2024-10-16 - 4 p.
Fulltext: PDF; Fulltext from Publisher: PDF;
|
|
4.
|
Review of particle physics
/ Particle Data Group Collaboration
The Review summarizes much of particle physics and cosmology. Using data from previous editions, plus 2,717 new measurements from 869 papers, we list, evaluate, and average measured properties of gauge bosons and the recently discovered Higgs boson, leptons, quarks, mesons, and baryons [...]
2024 - 2382 p.
- Published in : Phys. Rev. D 110 (2024) 030001
Fulltext: PDF;
|
|
5.
|
Neutron imaging with Micromegas detectors with optical readout
/ Cools, A (IRFU, Saclay) ; Aune, S (IRFU, Saclay) ; Brunbauer, F M (CERN) ; Benoit, T (IRFU, Saclay) ; Corsi, A (IRFU, Saclay) ; Ferrer-Ribas, E (IRFU, Saclay) ; Iguaz, F J (SOLEIL, Saint-Aubin) ; Mazoin, C (IRFU, Saclay) ; Oliveri, E (CERN) ; Papaevangelou, T (IRFU, Saclay) et al.
Optical readout of Micromegas gaseous detectors has been achieved by implementing a Micromegas detector on a glass substrate with a glass anode and a CMOS camera. Efficient X-ray radio-graphy has been demonstrated due to the integrated imaging approach inherent to optical readout. [...]
2023 - 4 p.
- Published in : EPJ Web Conf. 288 (2023) 07009
Fulltext: PDF;
In : Advancements in Nuclear Instrumentation Measurement Methods and their Applications (ANIMMA 2023), Lucca, Italy, 12 - 16 Jun 2023, pp.07009
|
|
6.
|
Photocathode characterisation for robust PICOSEC Micromegas precise-timing detectors
/ Lisowska, M. (CERN ; IRFU, Saclay) ; Aleksan, R. (IRFU, Saclay) ; Angelis, Y. (Aristotle U., Thessaloniki) ; Aune, S. (IRFU, Saclay) ; Bortfeldt, J. (Munich U.) ; Brunbauer, F. (CERN) ; Brunoldi, M. (Pavia U. ; INFN, Pavia) ; Chatzianagnostou, E. (Aristotle U., Thessaloniki) ; Datta, J. (SUNY, Stony Brook) ; Dehmelt, K. (Jefferson Lab) et al.
The PICOSEC Micromegas detector is a~precise-timing gaseous detector based on a~Cherenkov radiator coupled with a~semi-transparent photocathode and a~Micromegas amplifying structure, targeting a~time resolution of tens of picoseconds for minimum ionising particles. Initial single-pad prototypes have demonstrated a~time resolution below 25 ps, prompting ongoing developments to adapt the concept for High Energy Physics applications, where sub-nanosecond precision is essential for event separation, improved track reconstruction and particle identification. [...]
arXiv:2407.09953.-
2024-12-10 - 9 p.
- Published in : Nucl. Instrum. Methods Phys. Res., A 1072 (2025) 170151
Fulltext: 2407.09953 - PDF; 1732afb3515e2b936d222cb357afcde6 - PDF; Fulltext from Publisher: PDF; External link: Fermilab Library Server
|
|
7.
|
A Novel Diamond-like Carbon based photocathode for PICOSEC Micromegas detectors
/ Wang, X. (USTC, Hefei ; Hefei, CUST) ; Aleksan, R. (IRFU, Saclay) ; Angelis, Y. (Aristotle U., Thessaloniki) ; Bortfeldt, J. (LMU Munich (main)) ; Brunbauer, F. (CERN) ; Brunoldi, M. (Pavia U. ; INFN, Pavia) ; Chatzianagnostou, E. (Aristotle U., Thessaloniki) ; Datta, J. (Stony Brook U.) ; Degmelt, K. (Jefferson Lab) ; Fanourakis, G. (Democritos Nucl. Res. Ctr.) et al.
The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector based on a MM detector operating in a two-stage amplification mode and a Cherenkov radiator. Prototypes equipped with cesium iodide (CsI) photocathodes have shown promising time resolutions as precise as 24 picoseconds (ps) for Minimum Ionizing Particles. [...]
arXiv:2406.08712.-
2024-08-12 - 15 p.
- Published in : JINST 19 (2024) P08010
Fulltext: 806956891d4956950d85abdbaee8cf0d - PDF; 2406.08712 - PDF; Fulltext from Publisher: PDF; External link: Fermilab Library Server
|
|
8.
|
Single channel PICOSEC Micromegas detector with improved time resolution
/ Utrobicic, A. (Boskovic Inst., Zagreb) ; Aleksan, R. (IRFU, Saclay) ; Angelis, Y. (Aristotle U., Thessaloniki) ; Bortfeldt, J. (Munich U.) ; Brunbauer, F. (CERN) ; Brunoldi, M. (Pavia U. ; INFN, Pavia) ; Chatzianagnostou, E. (Aristotle U., Thessaloniki) ; Datta, J. (SUNY, Stony Brook) ; Dehmelt, K. (Jefferson Lab) ; Fanourakis, G. (American Coll. of Greece) et al.
This paper presents design guidelines and experimental verification of a single-channel PICOSEC Micromegas (MM) detector with an improved time resolution. The design encompasses the detector board, vessel, auxiliary mechanical parts, and electrical connectivity for high voltage (HV) and signals, focusing on improving stability, reducing noise, and ensuring signal integrity to optimize timing performance. [...]
arXiv:2406.05657; FERMILAB-PUB-24-0499-CMS-V.-
2024-12-16 - 11 p.
- Published in : Nucl. Instrum. Methods Phys. Res., A 1072 (2025) 170127
Fulltext: 2406.05657 - PDF; 9799b01fc06dbef84710538b6ae3d6d9 - PDF; External link: Fermilab Library Server
|
|
9.
|
|
10.
|
|