CERN Accelerating science

CERN Document Server 444 ჩანაწერია ნაპოვნი  1 - 10შემდეგიდასასრული  ჩანაწერთან გადასვლა: ძიებას დასჭირდა 0.76 წამი. 
1.
Performance evaluation of the FastIC readout ASIC with emphasis on Cherenkov emission in TOF-PET / Piller, Markus (CERN ; Graz U.) ; Castilla, Antonio M (Barcelona U.) ; Terragni, Giulia (CERN ; Vienna, Tech. U.) ; Alozy, Jerome (CERN) ; Auffray, Etiennette (CERN) ; Ballabriga, Rafael (CERN ; Barcelona U.) ; Campbell, Michael (CERN) ; Deutschmann, Bernd (Graz U.) ; Gascon, David (Barcelona U.) ; Gola, Alberto (Fond. Bruno Kessler, Trento) et al.
Objective. The efficient usage of prompt photons like Cherenkov emission is of great interest for the design of the next generation, cost-effective, and ultra-high-sensitivity time-of-flight positron emission tomography (TOF-PET) scanners. [...]
2024 - 13 p. - Published in : Phys. Med. Biol. 69 (2024) 115014 Fulltext: PDF;
2.
Optimizing time resolution and power consumption in a current-mode circuit for SiPMs / Manera, R (ICC, Barcelona U.) ; Gómez, S (Barcelona, Polytechnic U. ; ICC, Barcelona U.) ; Mariscal-Castilla, A (ICC, Barcelona U.) ; Mauricio, J (ICC, Barcelona U.) ; Ballabriga, R (CERN) ; Gascón, D (ICC, Barcelona U.)
Several applications that employ SiPMs require high time precision readout electronics. This work presents a study for the optimization of timing resolution of readout electronics for SiPMs focused on the effect of sensor area, transistor scaling and power consumption on electronic jitter. [...]
2024 - 21 p. - Published in : JINST 19 (2024) T04009 Fulltext: PDF;
3.
Fast28 a low-power fast readout design for SiPMs in 28nm CMOS / Piller, M (CERN ; Graz, Tech. U.) ; Ballabriga, R (CERN) ; Bandi, F (CERN) ; Campbell, M (CERN) ; Deutschmann, B (Graz, Tech. U.) ; Fernández-Tenllado, J M (CERN) ; Gascon, D (Barcelona U.) ; Gomez, S (Barcelona, Polytechnic U. ; Barcelona U.) ; Michalowska-Forsyth, A (Graz, Tech. U.) ; Mauricio, J (Barcelona U.) et al.
The field of detector readout electronics for precise timing has experienced a remarkable surge of interest due to its diverse range of applications in nuclear medicine such as Positron Emission Tomography (PET), High Energy Physics (HEP), Time-of-Flight (ToF) mass spectrometry and many other fields. This growth can be attributed to rapid advancements in photodetectors, particularly the silicon photomultiplier (SiPM), which has demonstrated exceptional suitability for these applications, owing to its ability to generate signals with unprecedentedly fast rise times. [...]
2023 - 1 p. - Published in : 10.1109/NSSMICRTSD49126.2023.10337864
In : 2023 IEEE Nuclear Science Symposium (NSS), Medical Imaging Conference (MIC) and Room Temperature Semiconductor Detector (RTSD) Conference (2023 IEEE NSS MIC RTSD), Vancouver, Canada, 4 - 11 Nov 2023
4.
FastIC ASIC readout performance for Cherenkov based TOF-PET imaging / Piller, M (CERN ; Graz U.) ; Mariscal-Castilla, A (Barcelona U.) ; Terragni, G (CERN ; TU Vienna) ; Penna, M (Fond. Bruno Kessler, Trento) ; Merzi, S (Fond. Bruno Kessler, Trento) ; Moretti, E (Fond. Bruno Kessler, Trento) ; Gola, A (Fond. Bruno Kessler, Trento) ; Michalowska-Forsyth, A (Graz, Tech. U.) ; Gascon, D (Barcelona U.) ; Ballabriga, R (CERN) et al.
The emerging field of ultra-fast timing has enormous potential in high-energy physics, nuclear medicine, and imaging, and is driving advances in detector and readout electronics. To achieve improved time resolution, significant efforts have been devoted to this field, resulting in impressive coincidence time resolution (CTR) values for silicon photomultiplier (SiPM) and scintillator crystals using state-of-the-art high-frequency (HF) readout. [...]
2023 - 1 p. - Published in : 10.1109/NSSMICRTSD49126.2023.10337861
In : 2023 IEEE Nuclear Science Symposium (NSS), Medical Imaging Conference (MIC) and Room Temperature Semiconductor Detector (RTSD) Conference (2023 IEEE NSS MIC RTSD), Vancouver, Canada, 4 - 11 Nov 2023
5.
The LHCb upgrade I / LHCb Collaboration
The LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. [...]
arXiv:2305.10515; LHCb-DP-2022-002.- 2024-05-23 - 232 p. - Published in : JINST 19 (2024) P05065 Fulltext: document - PDF; 2305.10515 - PDF;
In : The Large Hadron Collider and The Experiments for Run 3
6.
FastIC: a fast integrated circuit for the readout of high performance detectors / Gómez, S (Barcelona, Polytechnic U. ; Barcelona, IEEC) ; Alozy, J (CERN) ; Campbell, M (CERN) ; Fernandez-Tenllado, J M (CERN) ; Manera, R (Barcelona, IEEC) ; Mauricio, J (Barcelona, IEEC) ; Pujol, C (Barcelona, IEEC) ; Sanchez, D (Barcelona, IEEC) ; Sanmukh, A (Barcelona, IEEC) ; Sanuy, A (Barcelona, IEEC) et al.
This work presents the 8-channel FastIC ASIC developed in CMOS 65 nm technology suitable for the readout of positive and negative polarity sensors in high energy physics experiments, Cherenkov detectors and time-of-flight systems. The front-end can be configured to perform analog summation of up to 4 single-ended channels before discrimination in view of improving time resolution when segmenting a SiPM. [...]
2022 - 7 p. - Published in : JINST

In : TWEPP 2021 Topical Workshop on Electronics for Particle Physics, Online, Online, 20 - 24 Sep 2021, pp.C05027
7.
Performance of a spaghetti calorimeter prototype with tungsten absorber and garnet crystal fibres / An, Liupan (CERN) ; Auffray, Etiennette (CERN) ; Betti, Federico (CERN) ; Dall'Omo, Frederik (CERN) ; Gascon, David (ICC, Barcelona U.) ; Golutvin, Andrey (Imperial Coll., London) ; Guz, Yury (Serpukhov, IHEP) ; Kholodenko, Sergey (Serpukhov, IHEP) ; Martinazzoli, Loris (CERN ; Milan Bicocca U.) ; De Cos, José Mazorra (Valencia U., IFIC) et al.
A spaghetti calorimeter (SPACAL) prototype with scintillating crystal fibres was assembled and tested with electron beams of energy from 1 to 5 GeV. The prototype comprised radiation-hard Cerium-doped Gd$_3$Al$_2$Ga$_3$O$_{12}$ (GAGG:Ce) and Y$_3$Al$_5$O$_{12}$ (YAG:Ce) embedded in a pure tungsten absorber. [...]
arXiv:2205.02500.- 2023-01-01 - 14 p. - Published in : Nucl. Instrum. Methods Phys. Res., A 1045 (2023) 167629 Fulltext: 2205.02500 - PDF; Publication - PDF;
8.
High Sensitivity and High Resolution Dynamic Brain-Dedicated TOF-DOI PET Scanner / Bläckberg, L (Harvard Medical School) ; Sanchez, D (ICC, Barcelona U.) ; Borghi, G (ICC, Barcelona U.) ; Ballabriga, R (CERN) ; Sajedi, S (Stanford U., Med. School) ; Gómez, S (ICC, Barcelona U.) ; El Fakhri, G (Harvard Medical School) ; Mazzi, A (Fond. Bruno Kessler, Trento) ; Paternoster, G (Fond. Bruno Kessler, Trento) ; Majewski, S (UC, Davis) et al.
We are presenting a novel design of a high performance brain dedicated PET scanner which focuses on optimizing imaging performance in the whole brain, as well as in head and neck, through simultaneous high resolution and high sensitivity. This is realized using a sensitivity-optimized scanner design composed of an elliptical cylinder that follows the shape of the human head, together with added front and back panels for increased coverage. [...]
2020 - 5 p. - Published in : 10.1109/NSS/MIC42677.2020.9507837
In : 2020 IEEE Nuclear Science Symposium (NSS) and Medical Imaging Conference (MIC), Boston, United States, 31 Oct - 7 Nov 2020
9.
20-ps resolution Clock Distribution Network for a fast-timing single photon detector / Egidos, N (CERN) ; Ballabriga, R (CERN) ; Bandi, F (Seville U.) ; Campbell, M (CERN) ; Gascon, D (ICC, Barcelona U.) ; Gomez, S (ICC, Barcelona U.) ; Fernandez-Tenllado, J M (CERN) ; Llopart, X (CERN) ; Manera, R (ICC, Barcelona U.) ; Mauricio, J (ICC, Barcelona U.) et al.
The time resolution of active pixel sensors whose timestamp mechanism is based on Time-to-Digital Converters is critically linked to the accuracy in the distribution of the master clock signal that latches the timestamp values across the detector. The Clock Distribution Network that delivers the master clock signal must compensate process-voltage-temperature variations to reduce static time errors (skew), and minimize the power supply bounce to prevent dynamic time errors (jitter). [...]
2021 - 13 p. - Published in : 10.1109/tns.2021.3057581 fulltext from publisher: PDF;
10.
Multimodal simulation of large area silicon photomultipliers for time resolution optimization / Sánchez, David (ICC, Barcelona U.) ; Gómez, Sergio (ICC, Barcelona U.) ; Fernández-Tenllado, José María (ICC, Barcelona U. ; CERN) ; Ballabriga, Rafael (CERN) ; Campbell, Michael (CERN) ; Gascón, David (ICC, Barcelona U.)
The Silicon Photomultiplier (SiPM) sensor is replacing the extensive use of the Photomultiplier Tube (PMT) in fast timing applications. These photo-sensors can be applied in different fields such as medical imaging systems like Positron Emission Tomography (PET), LIDAR technologies or High Energy Physics (HEP) experiments. [...]
2021 - 11 p. - Published in : Nucl. Instrum. Methods Phys. Res., A 1001 (2021) 165247

CERN Document Server : 444 ჩანაწერია ნაპოვნი   1 - 10შემდეგიდასასრული  ჩანაწერთან გადასვლა:
ასევე იხილეთ: მსგავსი ავტორის სახელები
124 Gascon, D
383 Gascon, David
124 Gascón, D
48 Gascón, D.
383 Gascón, David
გნებავთ შეტყობინების მიღება, ამ კითხვაზე ახალი პასუხების შემთხვევაში?
დააყენეთ პირადი ელფოსტის შეტყობინება ან ჩაეწერეთ RSS ფიდზე.
ვერ იპოვნეთ რასაც ეძებდით? სცადეთ თქვენი ძებნა სხვა სერვერებზე:
Gascon, D. ში Amazon
Gascon, D. ში CERN EDMS
Gascon, D. ში CERN Intranet
Gascon, D. ში CiteSeer
Gascon, D. ში Google Books
Gascon, D. ში Google Scholar
Gascon, D. ში Google Web
Gascon, D. ში IEC
Gascon, D. ში IHS
Gascon, D. ში INSPIRE
Gascon, D. ში ISO
Gascon, D. ში KISS Books/Journals
Gascon, D. ში KISS Preprints
Gascon, D. ში NEBIS
Gascon, D. ში SLAC Library Catalog
Gascon, D. ში Scirus