CERN Accelerating science

CERN Document Server 2 のレコードが見つかりました。  検索にかかった時間: 1.31 秒 
1.
High-resolution laser spectroscopy of singly charged natural uranium isotopes / Raggio, Andrea (Jyvaskyla U.) ; Block, Michael (Darmstadt, GSI ; Mainz U., Inst. Phys. ; Helmholtz Inst., Mainz) ; Campbell, Paul (Manchester U.) ; Cheal, Bradley (Liverpool U.) ; deGroote, Ruben P (Jyvaskyla U. ; KU Leuven, Dept. Phys. Astron.) ; Gins, Wouter (Jyvaskyla U.) ; Koszorús, Ágota (Liverpool U. ; KU Leuven, Dept. Phys. Astron.) ; Moore, Iain D (Jyvaskyla U.) ; Ortiz-Cortes, Alejandro (Jyvaskyla U. ; GANIL ; Michigan State U., East Lansing (main)) ; Pohjalainen, Ilkka (Jyvaskyla U.) et al.
High-resolution collinear laser spectroscopy has been performed on singly charged ions of $^{234,235,238}$U at the IGISOL facility of the Accelerator Laboratory, University of Jyväskylä, in Finland. Ten ionic transitions from the $^{4}\hbox {I}_{9/2}$ and $^{6}\hbox {L}_{11/2}$ ground and first excited states were measured in the 300 nm wavelength range, improving the precision of the hyperfine parameters of the lower states in addition to providing newly measured values for the upper levels. [...]
2024 - 9 p. - Published in : Sci. Rep. 14 (2024) 25621 Fulltext: PDF;
2.
High-Precision Mass Measurements of Neutron Deficient Silver Isotopes Probe the Robustness of the <math display="inline"><mrow><mi>N</mi><mo>=</mo><mn>50</mn></mrow></math> Shell Closure / Ge, Zhuang (Jyvaskyla U.) ; Reponen, Mikael (Jyvaskyla U.) ; Eronen, Tommi (Jyvaskyla U.) ; Hu, Baishan (TRIUMF ; ORNL, Oak Ridge (main) ; Oak Ridge) ; Kortelainen, Markus (Jyvaskyla U.) ; Kankainen, Anu (Jyvaskyla U.) ; Moore, Iain (Jyvaskyla U.) ; Nesterenko, Dmitrii (Jyvaskyla U.) ; Yuan, Cenxi (SYSU, Guangzhou) ; Beliuskina, Olga (Jyvaskyla U.) et al.
High-precision mass measurements of exotic $^{95-97}$Ag isotopes close to the $N = Z$ line have been conducted with the JYFLTRAP double Penning trap mass spectrometer, with the silver ions produced using the recently commissioned inductively-heated hot cavity catcher laser ion source at the Ion Guide Isotope Separator On-Line facility. The atomic mass of $^{95}$Ag was directly determined for the first time. [...]
arXiv:2401.07976.- 2024-09-26 - 9 p. - Published in : Phys. Rev. Lett. 133 (2024) 132503 Fulltext: PDF;

似た著者名:
1 Ortiz-Cortes, A
1 Ortiz-Cortes, A.
Interested in being notified about new results for this query?
Set up a personal email alert or subscribe to the RSS feed.
捜していたものを見つけなかったならば、他のサーバーもお試しください:
Ortiz-Cortes, Alejandro 中の Amazon
Ortiz-Cortes, Alejandro 中の CERN EDMS
Ortiz-Cortes, Alejandro 中の CERN Intranet
Ortiz-Cortes, Alejandro 中の CiteSeer
Ortiz-Cortes, Alejandro 中の Google Books
Ortiz-Cortes, Alejandro 中の Google Scholar
Ortiz-Cortes, Alejandro 中の Google Web
Ortiz-Cortes, Alejandro 中の IEC
Ortiz-Cortes, Alejandro 中の IHS
Ortiz-Cortes, Alejandro 中の INSPIRE
Ortiz-Cortes, Alejandro 中の ISO
Ortiz-Cortes, Alejandro 中の KISS Books/Journals
Ortiz-Cortes, Alejandro 中の KISS Preprints
Ortiz-Cortes, Alejandro 中の NEBIS
Ortiz-Cortes, Alejandro 中の SLAC Library Catalog
Ortiz-Cortes, Alejandro 中の Scirus