CERN Accelerating science

CERN Document Server 26 record trovati  1 - 10successivofine  salta al record: La ricerca ha impiegato 0.89 secondi. 
1.
Beam test performance of a prototype module with Short Strip ASICs for the CMS HL-LHC tracker upgrade / Tracker Group of the CMS Collaboration
The Short Strip ASIC (SSA) is one of the four front-end chips designed for the upgrade of the CMS Outer Tracker for the High Luminosity LHC. Together with the Macro-Pixel ASIC (MPA) it will instrument modules containing a strip and a macro-pixel sensor stacked on top of each other. [...]
2022 - 24 p. - Published in : JINST 17 (2022) P06039 Fulltext: PDF; Fulltext from Publisher: PDF;
2.
Strategies and performance of the CMS silicon tracker alignment during LHC Run 2 / CMS Collaboration
The strategies for and the performance of the CMS silicon tracking system alignment during the 2015-2018 data-taking period of the LHC are described. The alignment procedures during and after data taking are explained. [...]
arXiv:2111.08757; CMS-TRK-20-001; CERN-EP-2021-203; CMS-TRK-20-001-003.- Geneva : CERN, 2022-08-11 - 45 p. - Published in : Nucl. Instrum. Methods Phys. Res., A 1037 (2022) 166795 Fulltext: fermilab-pub-21-673-cms - PDF; Publication - PDF; 2111.08757 - PDF; CMS-TRK-20-001-arXiv - PDF; Fulltext from Publisher: PDF; External link: Fermilab Library Server
3.
Comparative evaluation of analogue front-end designs for the CMS Inner Tracker at the High Luminosity LHC / CMS Tracker Group of the CMS Collaboration
The CMS Inner Tracker, made of silicon pixel modules, will be entirely replaced prior to the start of the High Luminosity LHC period. One of the crucial components of the new Inner Tracker system is the readout chip, being developed by the RD53 Collaboration, and in particular its analogue front-end, which receives the signal from the sensor and digitizes it. [...]
arXiv:2105.00070.- 2021-12-13 - 31 p. - Published in : JINST 16 (2021) P12014 Fulltext: fermilab-pub-21-744-cms - PDF; 2105.00070 - PDF; Fulltext from Publisher: PDF; External link: Fermilab Library Server
4.
The CMS Phase-1 Pixel Detector Upgrade / CMS Tracker Group of the CMS Collaboration
The CMS detector at the CERN LHC features a silicon pixel detector as its innermost subdetector. The original CMS pixel detector has been replaced with an upgraded pixel system (CMS Phase-1 pixel detector) in the extended year-end technical stop of the LHC in 2016/2017. [...]
arXiv:2012.14304.- 2021-02-22 - 84 p. - Published in : JINST 16 (2021) P02027 Fulltext: 2012.14304 - PDF; fermilab-pub-20-697-cms - PDF; Fulltext from Publisher: PDF; Fulltext from publisher: PDF; External link: Fermilab Accepted Manuscript
5.
Beam test performance of prototype silicon detectors for the Outer Tracker for the Phase-2 Upgrade of CMS / CMS Tracker Group Collaboration
A new CMS tracker detector will be installed for operation at the High Luminosity LHC (HL-LHC). This detector comprises modules with two closely spaced parallel sensor plates and front-end ASICs capable of transmitting tracking information to the CMS Level-1 (L1) trigger at the 40 MHz beam crossing rate. [...]
2020 - 32 p. - Published in : JINST 15 (2020) P03014 Fulltext: PDF;
6.
Experimental Study of Different Silicon Sensor Options for the Upgrade of the CMS Outer Tracker / Tracker Group of the CMS Collaboration
During the high-luminosity phase of the LHC (HL-LHC), planned to start around 2027, the accelerator is expected to deliver an instantaneous peak luminosity of up to $7.5\times10^{34}$ cm$^{-2}$s$^{-1}$. A total integrated luminosity of $3000$ or even $4000$~fb$^{-1}$ is foreseen to be delivered to the general purpose detectors ATLAS and CMS over a decade, thereby increasing the discovery potential of the LHC experiments significantly. [...]
arXiv:2001.02023.- 2020-04-22 - 34 p. - Published in : JINST 15 (2020) P04017 Fulltext: PDF; Fulltext from Publisher: PDF; Fulltext from publisher: PDF;
7.
The DAQ and control system for the CMS Phase-1 pixel detector upgrade / Adam, W (Vienna, OAW) ; Bergauer, T (Vienna, OAW) ; Blöch, D (Vienna, OAW) ; Brondolin, E (Vienna, OAW) ; Dragicevic, M (Vienna, OAW) ; Frühwirth, R (Vienna, OAW) ; Hinger, V (Vienna, OAW) ; Steininger, H (Vienna, OAW) ; Beaumont, W (Antwerp U.) ; Croce, D Di (Antwerp U.) et al. /CMS
In 2017 a new pixel detector was installed in the CMS detector. This so-called Phase-1 pixel detector features four barrel layers in the central region and three disks per end in the forward regions. [...]
2019 - 36 p. - Published in : JINST 14 (2019) P10017 Fulltext: PDF;
8.
Precision measurement of the structure of the CMS inner tracking system using nuclear interactions / CMS Collaboration
The structure of the CMS inner tracking system has been studied using nuclear interactions of hadrons striking its material. Data from proton-proton collisions at a center-of-mass energy of 13 TeV recorded in 2015 at the LHC are used to reconstruct millions of secondary vertices from these nuclear interactions. [...]
arXiv:1807.03289; CMS-TRK-17-001; CERN-EP-2018-144; CMS-TRK-17-001-003.- Geneva : CERN, 2018-10-29 - 41 p. - Published in : JINST 13 (2018) P10034 Fulltext: 1807.03289 - PDF; fulltext1682069 - PDF; Fulltext from Publisher: PDF; External link: Figures, tables and other information
9.
Characterisation of irradiated thin silicon sensors for the CMS phase II pixel upgrade / Adam, W (Vienna, OAW) ; Bergauer, T (Vienna, OAW) ; Brondolin, E (Vienna, OAW) ; Dragicevic, M (Vienna, OAW) ; Friedl, M (Vienna, OAW) ; Frühwirth, R (Vienna, OAW) ; Hoch, M (Vienna, OAW) ; Hrubec, J (Vienna, OAW) ; König, A (Vienna, OAW) ; Steininger, H (Vienna, OAW) et al. /Tracker Group
The high luminosity upgrade of the Large Hadron Collider, foreseen for 2026, necessitates the replacement of the CMS experiment’s silicon tracker. The innermost layer of the new pixel detector will be exposed to severe radiation, corresponding to a 1 MeV neutron equivalent fluence of up to $\Phi _{eq} = 2 \times 10^{16}$  cm$^{-2}$ , and an ionising dose of ${\approx } 5$  MGy after an integrated luminosity of 3000 fb$^{-1}$ . [...]
2017 - 13 p. - Published in : Eur. Phys. J. C 77 (2017) 567
10.
P-Type Silicon Strip Sensors for the new CMS Tracker at HL-LHC / Adam, W (Vienna, OAW) ; Bergauer, T (Vienna, OAW) ; Brondolin, E (Vienna, OAW) ; Dragicevic, M (Vienna, OAW) ; Friedl, M (Vienna, OAW) ; Frühwirth, R (Vienna, OAW) ; Hoch, M (Vienna, OAW) ; Hrubec, J (Vienna, OAW) ; König, A (Vienna, OAW) ; Steininger, H (Vienna, OAW) et al. /CMS
The upgrade of the LHC to the High-Luminosity LHC (HL-LHC) is expected to increase the LHC design luminosity by an order of magnitude. This will require silicon tracking detectors with a significantly higher radiation hardness. [...]
2017 - 27 p. - Published in : JINST 12 (2017) P06018 Fulltext: PDF;

CERN Document Server : 26 record trovati   1 - 10successivofine  salta al record:
Vedi anche: autori con nomi simili
7 Saizu, M A
10 Saizu, Mirela Angela
Sei interessato ad essere notificato su nuovi risultati di questa ricerca?
Imposta un avviso via mail personale o iscriviti al feed RSS.
Non hai trovato quello che cercavi? Prova la ricerca su altri server:
Saizu, M.A. in Amazon
Saizu, M.A. in CERN EDMS
Saizu, M.A. in CERN Intranet
Saizu, M.A. in CiteSeer
Saizu, M.A. in Google Books
Saizu, M.A. in Google Scholar
Saizu, M.A. in Google Web
Saizu, M.A. in IEC
Saizu, M.A. in IHS
Saizu, M.A. in INSPIRE
Saizu, M.A. in ISO
Saizu, M.A. in KISS Books/Journals
Saizu, M.A. in KISS Preprints
Saizu, M.A. in NEBIS
Saizu, M.A. in SLAC Library Catalog
Saizu, M.A. in Scirus