1.
|
Fulltext - Full text
|
2.
|
|
Damping effects in Penning trap mass spectrometry
/ George, S (Heidelberg, Max Planck Inst.) ; Block, M (Darmstadt, GSI) ; Kowalska, M (CERN ; Heidelberg, Max Planck Inst.) ; Dworschak, M (Darmstadt, GSI ; Mainz U., Inst. Phys.) ; Neidherr, D (Mainz U., Inst. Phys.) ; Blaum, K (Heidelberg U. ; Heidelberg, Max Planck Inst.) ; Schweikhard, L (Greifswald U.) ; Ramirez, E M (Darmstadt, GSI) ; Breitenfeldt, M (Greifswald U.) ; Kretzschmar, M (Mainz U., Inst. Phys.) et al.
Collisions of ions with residual gas atoms in a Penning trap can have a strong influence on the trajectories of the ions, depending on the atom species and the gas pressure. We report on investigations of damping effects in time-of-flight ion-cyclotron resonance mass spectrometry with the Penning trap mass spectrometers ISOLTRAP at ISOLDE/CERN (Geneva, Switzerland) and SHIPTRAP at GSI (Darmstadt, Germany). [...]
2011
- Published in : Int. J. Mass Spectrom. 299 (2011) 102-112
|
|
3.
|
New mass data for the rp-process above Z=32
/ Herfurth, F (Darmstadt, GSI) ; Delahaye, P (CERN) ; Dworschak, M (Darmstadt, GSI) ; Audi, G (CSNSM, Orsay) ; Mukherjee, M (Darmstadt, GSI) ; Beck, D (Darmstadt, GSI) ; Guenaut, C (CSNSM, Orsay) ; Rahaman, S (Darmstadt, GSI) ; Weber, C (Mainz U., Inst. Phys. ; Darmstadt, GSI) ; Lunney, D (CSNSM, Orsay) et al.
High-accuracy mass measurements have been performed with the Penning trap mass spectrometer ISOLTRAP at ISOLDE/CERN. The short-lived nuclides $^{70,71,72,73}$Se, $^{72,73,74,75}$Br, and $^{98,99,100,101,103}$Ag have been measured with an average uncertainty of a few keV. [...]
2011
- Published in : Eur. Phys. J. A 47 (2011) 75
|
|
4.
|
|
Approaching the $N=82$ shell closure with mass measurements of Ag and Cd isotopes
/ Breitenfeldt, M (Greifswald U.) ; Borgmann, Ch (Heidelberg, Max Planck Inst.) ; Audi, G (Orsay) ; Baruah, S (Greifswald U.) ; Beck, D (Darmstadt, GSI) ; Blaum, K (Heidelberg, Max Planck Inst. ; Heidelberg U.) ; Bohm, Ch (Heidelberg, Max Planck Inst.) ; Cakirli, R B (Heidelberg, Max Planck Inst. ; Istanbul U.) ; Casten, R F (Yale U.) ; Delahaye, P (CERN) et al.
2010 - 10 p.
- Published in : Phys. Rev. C 81 (2010) 034313
APS Published version, local copy: PDF;
|
|
5.
|
Mass measurements beyond the major r-process waiting point $^{80}$Zn
/ Baruah, S. (Greifswald U.) ; Audi, G. (CSNSM, Orsay) ; Blaum, K. (Darmstadt, GSI ; Mainz U., Inst. Phys.) ; Dworschak, M. (Darmstadt, GSI) ; George, S. (Darmstadt, GSI ; Mainz U., Inst. Phys.) ; Guenaut, C. (CSNSM, Orsay) ; Hager, U. (Jyvaskyla U.) ; Herfurth, F. (Darmstadt, GSI) ; Herlert, A. (Greifswald U.) ; Kellerbauer, A. (CERN) et al.
High-precision mass measurements on neutron-rich zinc isotopes $^{71m,72-81}$Zn have been performed with the Penning trap mass spectrometer ISOLTRAP. For the first time the mass of $^{81}$Zn has been experimentally determined. [...]
arXiv:0811.2294.-
2008 - 4 p.
- Published in : Phys. Rev. Lett. 101 (2008) 262501
APS Published version, local copy: PDF; Fulltext: PDF; External link: Preprint
|
|
6.
|
Restoration of the N=82 Shell Gap from Direct Mass Measurements of $^{132,134}$Sn
/ Dworschak, M (GSI, Darmstadt, Germany) ; Audi, G (CNRS, Univ. Paris Sud, Orsay, France) ; Blaum, K (GSI, Darmstadt, Germany ; Johannes Gutenberg-Univ., Mainz, Germany ; Max Planck Inst. for Nuclear Physics, Heidelberg, Germany) ; Delahaye, P (CERN) ; George, S (GSI, Darmstadt, Germany ; Johannes Gutenberg-Univ., Mainz, Germany) ; Hager, U (Univ. Jyväskylä, Jyväskylä, Finland) ; Herfurth, F (GSI, Darmstadt, Germany) ; Herlert, A (CERN) ; Kellerbauer, A G (Max Planck Inst. for Nuclear Physics, Heidelberg, Germany) ; Kluge, H J (GSI, Darmstadt, Germany ; Ruprecht-Karls-Univ., Heidelberg, Germany) et al.
A high-precision direct Penning trap mass measurement has revealed a 0.5-MeV deviation of the binding energy of $^{134}$Sn from the currently accepted value. The corrected mass assignment of this neutron-rich nuclide restores the neutron-shell gap at N=82, previously considered to be a case of “shell quenching.” In fact, the new shell gap value for the short-lived $^{132}$Sn is larger than that of the doubly-magic $^{48}$Ca which is stable. [...]
2008
- Published in : Phys. Rev. Lett. 100 (2008) 072501
APS Published version, local copy: PDF;
|
|
7.
|
High-precision mass measurements for reliable nuclear astrophysics calculations
/ Herlert, A ; Baruah, S ; Blaum, K ; Breitenfeldt, M ; Delahaye, P ; Dworschak, M ; George, S ; Guénaut, C ; Hager, U ; Herfurth, F et al.
2006
- Published in : PoS: NIC-IX (2006) , pp. 051
Published version from PoS: PDF;
In : 9th International Symposium on Nuclear Astrophysic: Nuclei in the Cosmos, CERN, Geneva, Switzerland, 25 - 30 Jun 2006, pp.051
|
|
8.
|
Towards a magnetic field stabilization at ISOLTRAP for high-accuracy mass measurements on exotic nuclides
/ Marie-Jeanne, M ; Alonso, J ; Blaum, K ; Djekic, S ; Dworschak, M ; Hager, U ; Herlert, A (CERN) ; Nagy, S ; Savreux, R ; Schweikhard, L et al.
The field stability of a mass spectrometer plays a crucial role in the accuracy of mass measurements. In the case of mass determination of short-lived nuclides with a Penning trap, major causes of fluctuations are temperature variations in the vicinity of the trap and pressure changes in the liquid helium cryostat of the superconducting magnet. [...]
2008
- Published in : Nucl. Instrum. Methods Phys. Res., A 587 (2008) 464-473
|
|
9.
|
Spin-related aspects of mass determination of radionuclides
/ Herlert, A (CERN) ; Baruah, S ; Delahaye, P (CERN) ; Dworschak, M ; George, S ; Guénaut, C ; Hager, U ; Herfurth, F ; Kellerbauer, A G (CERN) ; Kluge, H J et al.
2006
- Published in : Czechoslov. J. Phys. 56 (2006) F277-F286
In : Advanced Studies Institution Symmetries and Spin, Prague, Czech Republic, 19 - 26 Jul 2006, pp.277-286
|
|
10.
|
Magnetic field stabilization for high-accuracy mass measurements on exotic nuclides
/ Marie-Jeanne, M. (Caen U.) ; Alonso, J. (Mainz U., Inst. Phys.) ; Blaum, K. (Mainz U., Inst. Phys. ; Darmstadt, GSI) ; Djekic, S. (Mainz U., Inst. Phys.) ; Dworschak, M. (Darmstadt, GSI) ; Hager, U. (Jyvaskyla U.) ; Herlert, A. (CERN) ; Nagy, Sz. (Mainz U., Inst. Phys.) ; Savreux, R. (Darmstadt, GSI) ; Schweikhard, L. (Greifswald U.) et al.
The magnetic-field stability of a mass spectrometer plays a crucial role in precision mass measurements. In the case of mass determination of short-lived nuclides with a Penning trap, major causes of instabilities are temperature fluctuations in the vicinity of the trap and pressure fluctuations in the liquid helium cryostat of the superconducting magnet. [...]
physics/0701224.-
2007 - 23 p.
- Published in : Nucl. Instrum. Methods Phys. Res., A 587 (2008) 464-473
Access to fulltext document: PDF; Fulltext: PDF; External link: physics/0701224 PDF
|
|