CERN Accelerating science

CERN Document Server 11 records found  1 - 10next  jump to record: Search took 0.64 seconds. 
1.
Sensitivity projections for a dual-phase argon TPC optimized for light dark matter searches through the ionization channel / Global Argon Dark Matter Collaboration
Dark matter lighter than 10 GeV/c$^2$ encompasses a promising range of candidates. A conceptual design for a new detector, DarkSide-LowMass, is presented, based on the DarkSide-50 detector and progress toward DarkSide-20k, optimized for a low-threshold electron-counting measurement. [...]
arXiv:2209.01177.- 2023-06-01 - 19 p. - Published in : Phys. Rev. D 107 (2023) 112006 Fulltext: 2209.01177 - PDF; 91ce6168799b33f720d8ae133fe8e56d - PDF; External link: Fermilab Library Server
2.
Separating $^{39}$Ar from $^{40}$Ar by cryogenic distillation with Aria for dark matter searches / DarkSide Collaboration
The Aria project consists of a plant, hosting a 350 m cryogenic isotopic distillation column, the tallest ever built, which is currently in the installation phase in a mine shaft at Carbosulcis S.p.A., Nuraxi-Figus (SU), Italy. Aria is one of the pillars of the argon dark-matter search experimental program, lead by the Global Argon Dark Matter Collaboration. [...]
arXiv:2101.08686.- 2021-04-26 - 18 p. - Published in : Eur. Phys. J. C 81 (2021) 359 Article from SCOAP3: PDF; Fulltext: PDF; Fulltext from Publisher: PDF;
3.
Sensitivity of future liquid argon dark matter search experiments to core-collapse supernova neutrinos / DarkSide 20k Collaboration
Future liquid-argon DarkSide-20k and ARGO detectors, designed for direct dark matter search, will be sensitive also to core-collapse supernova neutrinos, via coherent elastic neutrino-nucleus scattering. This interaction channel is flavor-insensitive with a high-cross section, enabling for a high-statistics neutrino detection with target masses of $\sim$50~t and $\sim$360~t for DarkSide-20k and ARGO, respectively. [...]
arXiv:2011.07819.- 2021-03-15 - 22 p. - Published in : JCAP 2103 (2021) 043 Fulltext: 2011.07819 - PDF; fermilab-pub-20-601-nd-ppd - PDF; External link: Fermilab Library Server (fulltext available)
4.
SiPM-matrix readout of two-phase argon detectors using electroluminescence in the visible and near infrared range / DarkSide Collaboration
Proportional electroluminescence (EL) in noble gases is used in two-phase detectors for dark matter searches to record (in the gas phase) the ionization signal induced by particle scattering in the liquid phase. The "standard" EL mechanism is considered to be due to noble gas excimer emission in the vacuum ultraviolet (VUV). [...]
arXiv:2004.02024; FERMILAB-PUB-20-155-PPD.- 2021-02-15 - 26 p. - Published in : Eur. Phys. J. C 81 (2021) 153 Article from SCOAP3: PDF; Fulltext: 2004.02024 - PDF; fermilab-pub-20-155-ppd - PDF; External link: Fermilab Library Server (fulltext available)
5.
Design and construction of a new detector to measure ultra-low radioactive-isotope contamination of argon / DarkSide Collaboration
Large liquid argon detectors offer one of the best avenues for the detection of galactic weakly interacting massive particles (WIMPs) via their scattering on atomic nuclei. The liquid argon target allows exquisite discrimination between nuclear and electron recoil signals via pulse-shape discrimination of the scintillation signals. [...]
arXiv:2001.08106.- 2020-02-26 - 19 p. - Published in : JINST 15 (2020) P02024 Fulltext: fermilab-pub-20-023-ppd - PDF; 2001.08106 - PDF; Fulltext from Publisher: PDF; External link: Fermilab Library Server (fulltext available)
6.
EURECA – setting the scene for scintillators / Kraus, H (Oxford U.) ; Armengau, E. (IRFU, Saclay) ; Bauer, M. (Tubingen U.) ; Bavykina, I. (Munich, Max Planck Inst.) ; Benoit, A. (Grenoble, CRTBT) ; Bento, A. (Munich, Max Planck Inst.) ; Blumer, J. (Karlsruhe U., EKP ; Karlsruhe, Forschungszentrum) ; Bornschein, L. (Karlsruhe U., EKP) ; Broniatowski, A. (CSNSM, Orsay) ; Burghart, G. (CERN) et al.
EURECA (European Underground Rare Event Calorimeter Array) will be an astro-particle physics facility aiming to directly detect galactic dark matter. The Laboratoire Souterrain de Modane has been selected as host laboratory. [...]
2009
In : 1st International Workshop on Radiopure Scintillators for EURECA, Kiev, Ukraine, 9 - 10 Sep 2008, pp.7-11
7.
Results of CRESST phase I / Cozzini, C ; Altmann, M ; Angloher, G ; Bruckmayer, M ; Bucci, C ; Cooper, S ; Di Stefano, P ; Feilitzsch, F V ; Frank, T ; Hauff, D et al.
2001
In : 9th International Workshop on Low Temperature Detectors, Madison, WI, USA, 23 - 27 Jul 2001, pp.481-484
8.
Dark matter search using a 70 g Ge bolometer in the Frejus underground laboratory / L’Hote, D ; Bergé, L ; Berkès, I ; Chambon, B ; Chapellier, M ; Chardin, G ; Charvin, P ; De Jésus, M ; Drain, D ; Dumoulin, L et al.
1997
In : 7th International Workshop on Low-Temperature Detectors, Munich, Germany, 27 Jul - 2 Aug 1997, pp.237-239
9.
Development of 300g scintillating calorimeters / Frank, T ; Angloher, G ; Bruckmayer, M ; Cozzini, C ; Di Stefano, P ; Hauff, D ; Pröbst, F ; Schmidt, J ; Seidel, W
2001
In : 9th International Workshop on Low Temperature Detectors, Madison, WI, USA, 23 - 27 Jul 2001, pp.501-504
10.
Latest results from the EDELWEISS WIMP search / EDELWEISS Collaboration
DAPNIA-2003-276.
- 2003. - 10 p.
Fulltext

CERN Document Server : 11 records found   1 - 10next  jump to record:
Interested in being notified about new results for this query?
Set up a personal email alert or subscribe to the RSS feed.
Haven't found what you were looking for? Try your search on other servers:
Di Stefano, P. in Amazon
Di Stefano, P. in CERN EDMS
Di Stefano, P. in CERN Intranet
Di Stefano, P. in CiteSeer
Di Stefano, P. in Google Books
Di Stefano, P. in Google Scholar
Di Stefano, P. in Google Web
Di Stefano, P. in IEC
Di Stefano, P. in IHS
Di Stefano, P. in INSPIRE
Di Stefano, P. in ISO
Di Stefano, P. in KISS Books/Journals
Di Stefano, P. in KISS Preprints
Di Stefano, P. in NEBIS
Di Stefano, P. in SLAC Library Catalog
Di Stefano, P. in Scirus