CERN Accelerating science

CERN Document Server 5 records found  Search took 1.21 seconds. 
1.
The ATLAS experiment at the CERN Large Hadron Collider: a description of the detector configuration for Run 3 / ATLAS Collaboration
The ATLAS detector is installed in its experimental cavern at Point 1 of the CERN Large Hadron Collider. During Run 2 of the LHC, a luminosity of $\mathcal{L}=2\times 10^{34}\mathrm{cm}^{-2}\mathrm{s}^{-1}$ was routinely achieved at the start of fills, twice the design luminosity. [...]
arXiv:2305.16623; CERN-EP-2022-259.- Geneva : CERN, 2024-05-23 - 233 p. - Published in : JINST 19 (2024) P05063 Fulltext: 2305.16623 - PDF; document - PDF; External link: Previous draft version
In : The Large Hadron Collider and The Experiments for Run 3
2.
The Phase-I Trigger Readout Electronics Upgrade of the ATLAS Liquid Argon Calorimeters / Aad, G. (Marseille, CPPM) ; Akimov, A.V. (CERN ; LPI, Moscow (main)) ; Al Khoury, K. (Nevis Labs, Columbia U.) ; Aleksa, M. (CERN) ; Andeen, T. (Arizona U.) ; Anelli, C. (Victoria U.) ; Aranzabal, N. (CERN) ; Armijo, C. (Arizona U.) ; Bagulia, A. (Lebedev Inst.) ; Ban, J. (Nevis Labs, Columbia U.) et al.
The Phase-I trigger readout electronics upgrade of the ATLAS Liquid Argon calorimeters enhances the physics reach of the experiment during the upcoming operation at increasing Large Hadron Collider luminosities. The new system, installed during the second Large Hadron Collider Long Shutdown, increases the trigger readout granularity by up to a factor of ten as well as its precision and range. [...]
arXiv:2202.07384.- 2022-05-16 - 56 p. - Published in : JINST 17 (2022) P05024 Fulltext: document - PDF; 2202.07384 - PDF; Publication - PDF;
3.
Design and Evaluation of the LAr Trigger Digitizer Board in the ATLAS Phase-I Upgrade / Besin, Dominique (Brookhaven Natl. Lab.) ; Chen, Hucheng (Brookhaven Natl. Lab.) ; Chen, Kai (Brookhaven Natl. Lab.) ; Citterio, Mauro (INFN, Milan) ; Deschamps, Herve (Saclay) ; Grabas, Aude (Saclay) ; Lanni, Francesco (Brookhaven Natl. Lab.) ; Latorre, Stefano (INFN, Milan) ; Lazzaroni, Massimo (INFN, Milan) ; Liu, Hongbin (Brookhaven Natl. Lab.) et al.
The LHC upgrade is planned to enhance the instantaneous luminosity during Run 3 from 2021 through 2023. The Phase-I upgrade of the trigger readout electronics for the ATLAS Liquid Argon (LAr) Calorimeters will be installed during the second long shutdown of LHC in 2019-2020. [...]
arXiv:1806.08046.- 2019-06-24 - 6 p. - Published in : IEEE Trans. Nucl. Sci. 66 (2019) 2011-2016 Fulltext: PDF;
In : 21st IEEE Real Time Conference, Williamsburg, Va, United States Of America, 9 - 15 Jun 2018, pp.2011-2016
4.
Micromegas in CAST and prospects / Abbon, P (IRFU, Saclay) ; Andriamonje, S (IRFU, Saclay) ; Aune, S (IRFU, Saclay) ; Besin, D (IRFU, Saclay) ; Cazaux, S (IRFU, Saclay) ; Dafni, T (IRFU, SPhN, Saclay) ; Decker, T (LLNL, Livermore) ; Dogan, B O (Bogazici U.) ; Duportail, N (IRFU, Saclay) ; Fanourakis, G (Democritos Nucl. Res. Ctr.) et al.
A low background Micromegas X-ray detector has been used to search for solar axions in the CAST experiment at CERN. The detector has an active area of 7cm times 7cm, excellent spatial resolution (~70nm), and good energy resolution. [...]
Oct. - 6 p. - Published in : 10.1109/NSSMIC.2006.353827
In : Nuclear Medical Imaging Conference, San Diego, CA, USA, 29 Oct - 4 Nov 2006, pp.3832-3837
5.
A low background Micromegas detector for the CAST experiment / Abbon, P. (DSM, DAPNIA, Saclay) ; Andriamonje, S. (DSM, DAPNIA, Saclay) ; Aune, S. (DSM, DAPNIA, Saclay) ; Besin, D. (DSM, DAPNIA, Saclay) ; Cazaux, S. (DSM, DAPNIA, Saclay) ; Contrepois, P. (DSM, DAPNIA, Saclay) ; Duportail, N. (DSM, DAPNIA, Saclay) ; Ferrer Ribas, E. (DSM, DAPNIA, Saclay) ; Gros, M. (DSM, DAPNIA, Saclay) ; Irastorza, I.G. (DSM, DAPNIA, Saclay) et al.
A low background Micromegas detector has been operating on the CAST experiment at CERN for the search of solar axions during the first phase of the experiment (2002-2004). The detector operated efficiently and achieved a very low level of background rejection ($5\times 10^{-5}$ counts keV$^{-1}$cm$^{-2}$s$^{-1}$) thanks to its good spatial and energy resolution as well as the low radioactivity materials used in the construction of the detector. [...]
physics/0510258; DAPNIA-05-296; DAPNIA-2005-296.- Saclay : DAPNIA, 2005 - 5 p. - Published in : 10.1142/9789812773678_0032 Access to fulltext document: PDF; Fulltext: PDF; External link: physics/0510258 PDF
In : 9th ICATPP Conference on Astroparticle, Particle, Space Physics, Detectors and Medical Physics Applications, Como, Italy, 17 - 21 Oct 2005, pp.196-200

See also: similar author names
2 Besin, D
2 Besin, Dominique
Interested in being notified about new results for this query?
Set up a personal email alert or subscribe to the RSS feed.
Haven't found what you were looking for? Try your search on other servers:
Besin, D. in Amazon
Besin, D. in CERN EDMS
Besin, D. in CERN Intranet
Besin, D. in CiteSeer
Besin, D. in Google Books
Besin, D. in Google Scholar
Besin, D. in Google Web
Besin, D. in IEC
Besin, D. in IHS
Besin, D. in INSPIRE
Besin, D. in ISO
Besin, D. in KISS Books/Journals
Besin, D. in KISS Preprints
Besin, D. in NEBIS
Besin, D. in SLAC Library Catalog
Besin, D. in Scirus