CERN Accelerating science

CERN Document Server 25 εγγραφές βρέθηκαν  1 - 10επόμενοτέλος  μετάβαση στην εγγραφή: Η έρευνα πήρε 0.56 δευτερόλεπτα. 
1.
Demonstration of Gd-GEM detector design for neutron macromolecular crystallography applications / Pfeiffer, D. (ESS, Lund ; CERN ; Milan Bicocca U.) ; Brunbauer, F. (CERN) ; Cristiglio, V. (Laue-Langevin Inst.) ; Hall-Wilton, R. (ESS, Lund ; Milan Bicocca U. ; Fond. Bruno Kessler, Trento) ; Lupbergerf, M. (Bonn U., HISKP) ; Markó, M. (Wigner RCP, Budapest) ; Muller, H. (CERN ; Bonn U.) ; Oksanen, E. (ESS, Lund) ; Oliveri, E. (CERN) ; Ropelewski, L. (CERN) et al.
The European Spallation Source (ESS) in Lund, Sweden will become the world's most powerful thermal neutron source. The Macromolecular Diffractometer (NMX) at the ESS requires three 51.2 x 51.2~cm$^{2}$ detectors with reasonable detection efficiency, sub-mm spatial resolution, a narrow point spread function (PSF) and good time resolution. [...]
arXiv:2211.04335.- 2023-04-18 - 18 p. - Published in : JINST 18 (2023) P04023 Fulltext: 2211.04335 - PDF; document - PDF;
2.
PICOSEC-Micromegas: Robustness measurements and study of different photocathode materials / Sohl, L (IRFU, Saclay) ; Bortfeldt, J (CERN) ; Brunbauer, F (CERN) ; David, C (CERN) ; Desforge, D (IRFU, Saclay) ; Fanourakis, G (Democritos Nucl. Res. Ctr.) ; Franchi, J (CERN) ; Gallinaro, M (LIP, Lisbon) ; García, F (Helsinki U.) ; Giomataris, I (IRFU, Saclay) et al.
Detectors with a time resolution of 20-30 ps and a reliable performance in high particles flux environments are necessary for an accurate vertex separation in future HEP experiments. The PICOSEC-Micromegas detector concept is a Micro-Pattern Gaseous Detector (MPGD) based solution addressing this particular challenge. [...]
2019 - 7 p. - Published in : J. Phys. : Conf. Ser. 1312 (2019) 012012 Fulltext from Publisher: PDF;
In : 9th Symposium on Large TPCs for Low-Energy Rare Event Detection, Paris, France, 12 - 14 Dec 2018, pp.012012
3.
Precise timing with the PICOSEC-Micromegas detector / Sampsonidis, D (Thessaloniki U.) ; Bortfeldt, J (CERN) ; Brunbauer, F (CERN) ; David, C (CERN) ; Desforge, D (IRFU, Saclay) ; Fanourakis, G (Democritos Nucl. Res. Ctr.) ; Franchi, J (CERN) ; Gallinaro, M (LIP, Lisbon) ; García, F (Helsinki U.) ; Giomataris, I (IRFU, Saclay) et al.
This work presents the concept of the PICOSEC-Micromegas detector to achieve a time resolution below 30 ps. PICOSEC consists of a two-stage Micromegas detector coupled to a Cherenkov radiator and equipped with a photocathode. [...]
2020 - 9 p. - Published in : Nuovo Cimento C 43 (2020) 13 Fulltext: PDF;
In : FAst Timing Applications for nuclear physics and medical imaging (FATA 2019), Acireale, Italy, 3 - 5 Sep 2019, pp.13
4.
SRS VMM readout for Gadolinium GEM-based detector prototypes for the NMX instrument at ESS / Lupberger, Michael (CERN) ; Brunbauer, Florian Maximilian (CERN) ; Huang, Yan (Hua-Zhong Normal U.) ; Müller, Hans (CERN) ; Oliveri, Eraldo (CERN) ; Pfeiffer, Dorothea (ESS, Lund) ; Ropelewski, Leszek (CERN) ; Van Stenis, Miranda (CERN) ; Thuiner, Patrik (CERN)
We report on further development and application of a general purpose readout system, the Scalable Readout System (SRS). The SRS was introduced by the RD51 collaboration in 2009 in a common effort. [...]
2020 - 6 p. - Published in : J. Phys.: Conf. Ser. 1498 (2020) 012050 Fulltext: PDF;
In : 6th International Conference on Micro Pattern Gaseous Detectors, La Rochelle, France, 5 - 10 May 2019, pp.012050
5.
Recent Developments on Precise Timing with the PICOSEC Micromegas Detector / Manthos, I (Aristotle U., Thessaloniki) ; Bortfeldt, J (CERN) ; Brunbauer, F (CERN) ; David, C (CERN) ; Desforge, D (IRFU, Saclay) ; Fanourakis, G (Democritos Nucl. Res. Ctr.) ; Franchi, J (CERN) ; Gallinaro, M (LIP, Lisbon) ; García, F (Helsinki Inst. of Phys.) ; Giomataris, I (IRFU, Saclay) et al.
The PICOSEC-Micromegas detector was developed for precise timing of the arrival of charged particles with a resolution bellow 30 ps. This contribution, after a brief introduction presents results concerning the PICOSEC-Micromegas response to single photoelectrons, estimation of the photoelectron yield of various photocathode types, as well as its performance to time the arrival of test beam muons. [...]
2020 - 8 p. - Published in : J. Phys.: Conf. Ser. 1498 (2020) 012014 Fulltext: PDF;
In : 6th International Conference on Micro Pattern Gaseous Detectors, La Rochelle, France, 5 - 10 May 2019, pp.012014
6.
Single photoelectron time resolution studies of the PICOSEC-Micromegas detector / Sohl, L (IRFU, Saclay) ; Aune, S (IRFU, Saclay) ; Bortfeldt, J (CERN) ; Brunbauer, F (CERN) ; David, C (CERN) ; Desforge, D (IRFU, Saclay) ; Fanourakis, G (Democritos Nucl. Res. Ctr.) ; Gallinaro, M (LIP, Lisbon) ; García, F (Helsinki Inst. of Phys.) ; Giomataris, I (IRFU, Saclay) et al.
Detectors with a time resolution of a few tens of picoseconds and long-term durability in high particle fluxes are necessary for an accurate vertex separation in future particle physics experiments. The PICOSEC-Micromegas detector concept is a Micro-Pattern Gaseous Detector (MPGD) based solution addressing this particular challenge. [...]
2020 - 12 p. - Published in : JINST 15 (2020) C04053
In : 15th Topical Seminar on Innovative Particle and Radiation Detectors (IPRD 2019), Siena, Italy, 14 - 17 Oct 2019, pp.C04053
7.
Progress on the PICOSEC-Micromegas Detector Development: Towards a precise timing, radiation hard, large-scale particle detector with segmented readout / Kordas, K (Aristotle U., Thessaloniki) ; Bortfeldt, J (CERN) ; Brunbauer, F (CERN) ; David, C (CERN) ; Desforge, D (IRFU, Saclay) ; Fanourakis, G (Democritos Nucl. Res. Ctr.) ; Franchi, J (CERN) ; Gallinaro, M (LIP, Lisbon) ; García, F (Helsinki U.) ; Giomataris, I (IRFU, Saclay) et al.
This contribution describes the PICOSEC-Micromegas detector which achieves a time resolution below 25 ps. In this device the passage of a charged particle produces Cherenkov photons in a radiator, which then generate electrons in a photocathode and these photoelectrons enter a two-stage Micromegas with a reduced drift region and a typical anode region. [...]
Elsevier, 2020 - 5 p. - Published in : Nucl. Instrum. Methods Phys. Res., A 958 (2020) 162877
In : 15th Vienna Conference on Instrumentation, Vienna, Austria, 18 - 22 Feb 2019, pp.162877
8.
3D printing of gaseous radiation detectors / Brunbauer, F M (CERN ; Lund U.) ; Lupberger, M (Bonn U.) ; Müller, H (CERN) ; Oliveri, E (CERN) ; Pfeiffer, D (Lund U. ; CERN) ; Ropelewski, L (CERN) ; Scharenberg, L (CERN ; Bonn U.) ; Thuiner, P (CERN) ; Van Stenis, M (CERN)
Additive manufacturing techniques such as 3D printing offer unprecedented flexibility in realising intricate geometries. Fused-filament fabrication and high-precision inkjet 3D printing of metals and polymers was used to create functional composite structures, which were operated as radiation detectors. [...]
2019 - 13 p. - Published in : JINST 14 (2019) P12005 Fulltext: PDF;
9.
Timing Performance of a Micro-Channel-Plate Photomultiplier Tube / Bortfeldt, Jonathan (CERN) ; Brunbauer, F. (CERN) ; David, C. (CERN) ; Desforge, D. (IRFU, Saclay) ; Fanourakis, G. (Democritos Nucl. Res. Ctr.) ; Gallinaro, M. (LIP, Lisbon) ; Garcıa, F. (Helsinki U.) ; Giomataris, I. (IRFU, Saclay) ; Gustavsson, T. (LIDYL, Saclay) ; Guyot, C. (IRFU, Saclay) et al.
The spatial dependence of the timing performance of the R3809U-50 Micro-Channel-Plate PMT (MCP-PMT) by Hamamatsu was studied in high energy muon beams. Particle position information is provided by a GEM tracker telescope, while timing is measured relative to a second MCP-PMT, identical in construction. [...]
arXiv:1909.12604.- 2020-04-21 - 6 p. - Published in : Nucl. Instrum. Methods Phys. Res., A 960 (2020) 163592 Fulltext: PDF; Fulltext from Publisher: PDF; Published fulltext: 1-s2.0-S0168900220301613-main - PDF; a51dae9a2ef3e2858edfe138fb2dec2d - PDF;
10.
Precise Charged Particle Timing with the PICOSEC Detector / Bortfeldt, J. (CERN) ; Brunbauer, F. (CERN) ; David, C. (CERN) ; Desforge, D. (IRFU, Saclay) ; Fanourakis, G. (Democritos Nucl. Res. Ctr.) ; Franchi, J. (CERN) ; Gallinaro, M. (LIP, Lisbon) ; García, F. (Helsinki Inst. of Phys.) ; Giomataris, I. (IRFU, Saclay) ; Gustavsson, T. (LIDYL, Saclay) et al.
The experimental requirements in near future accelerators (e.g. High Luminosity-LHC) has stimulated intense interest in development of detectors with high precision timing capabilities. [...]
arXiv:1901.03355.- 2019-02-26 - 7 p. - Published in : AIP Conf. Proc. 2075 (2019) 080009 Fulltext: PDF;
In : 10th International Physics Conference of the Balkan Physical Union, Sofia, Bulgaria, 26 - 30 Aug 2018, pp.080009

CERN Document Server : 25 εγγραφές βρέθηκαν   1 - 10επόμενοτέλος  μετάβαση στην εγγραφή:
Δείτε ακόμη: παρόμοια ονόματα συγγραφέων
11 Thuiner, P
5 Thuiner, Patrik
Ενδιαφέρεστε να ενημερώνεστε για νέα αποτελέσματα σχετικά με το ερώτημα αυτό;
Δημιουργήστε ένα προσωπικό email alert ή εγγραφείτε στο RSS feed.
Δεν βρήκατε αυτό που αναζητούσατε; Δοκιμάστε την έρευνά σας σε άλλους servers:
Thuiner, P. σε Amazon
Thuiner, P. σε CERN EDMS
Thuiner, P. σε CERN Intranet
Thuiner, P. σε CiteSeer
Thuiner, P. σε Google Books
Thuiner, P. σε Google Scholar
Thuiner, P. σε Google Web
Thuiner, P. σε IEC
Thuiner, P. σε IHS
Thuiner, P. σε INSPIRE
Thuiner, P. σε ISO
Thuiner, P. σε KISS Books/Journals
Thuiner, P. σε KISS Preprints
Thuiner, P. σε NEBIS
Thuiner, P. σε SLAC Library Catalog
Thuiner, P. σε Scirus