1.
|
PICOSEC-Micromegas Detector, an innovative solution for Lepton Time Tagging
/ Kallitsopoulou, A. (IRFU, Saclay) ; Aleksan, R. (IRFU, Saclay) ; Angelis, Y. (Aristotle U., Thessaloniki) ; Aune, S. (IRFU, Saclay) ; Bortfeldt, J. (Munich U.) ; Brunbauer, F. (CERN) ; Brunoldi, M. (Pavia U. ; INFN, Pavia) ; Chatzianagnostou, E. (Aristotle U., Thessaloniki) ; Datta, J. (SUNY, Stony Brook) ; Desforge, D. (IRFU, Saclay) et al.
The PICOSEC-Micromegas (PICOSEC-MM) detector is a novel gaseous detector designed for precise timing resolution in experimental measurements. It eliminates time jitter from charged particles in ionization gaps by using extreme UV Cherenkov light emitted in a crystal, detected by a Micromegas photodetector with an appropriate photocathode. [...]
arXiv:2411.02532.-
2024-10-16 - 4 p.
Fulltext: PDF;
|
|
2.
|
|
3.
|
Photocathode characterisation for robust PICOSEC Micromegas precise-timing detectors
/ Lisowska, M. (CERN ; IRFU, Saclay) ; Aleksan, R. (IRFU, Saclay) ; Angelis, Y. (Aristotle U., Thessaloniki) ; Aune, S. (IRFU, Saclay) ; Bortfeldt, J. (Munich U.) ; Brunbauer, F. (CERN) ; Brunoldi, M. (Pavia U. ; INFN, Pavia) ; Chatzianagnostou, E. (Aristotle U., Thessaloniki) ; Datta, J. (SUNY, Stony Brook) ; Dehmelt, K. (Jefferson Lab) et al.
The PICOSEC Micromegas detector is a~precise-timing gaseous detector based on a~Cherenkov radiator coupled with a~semi-transparent photocathode and a~Micromegas amplifying structure, targeting a~time resolution of tens of picoseconds for minimum ionising particles. Initial single-pad prototypes have demonstrated a~time resolution below 25 ps, prompting ongoing developments to adapt the concept for High Energy Physics applications, where sub-nanosecond precision is essential for event separation, improved track reconstruction and particle identification. [...]
arXiv:2407.09953.-
2024-12-10 - 9 p.
- Published in : Nucl. Instrum. Methods Phys. Res., A 1072 (2025) 170151
Fulltext: 2407.09953 - PDF; 1732afb3515e2b936d222cb357afcde6 - PDF; External link: Fermilab Library Server
|
|
4.
|
A Novel Diamond-like Carbon based photocathode for PICOSEC Micromegas detectors
/ Wang, X. (USTC, Hefei ; Hefei, CUST) ; Aleksan, R. (IRFU, Saclay) ; Angelis, Y. (Aristotle U., Thessaloniki) ; Bortfeldt, J. (LMU Munich (main)) ; Brunbauer, F. (CERN) ; Brunoldi, M. (Pavia U. ; INFN, Pavia) ; Chatzianagnostou, E. (Aristotle U., Thessaloniki) ; Datta, J. (Stony Brook U.) ; Degmelt, K. (Jefferson Lab) ; Fanourakis, G. (Democritos Nucl. Res. Ctr.) et al.
The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector based on a MM detector operating in a two-stage amplification mode and a Cherenkov radiator. Prototypes equipped with cesium iodide (CsI) photocathodes have shown promising time resolutions as precise as 24 picoseconds (ps) for Minimum Ionizing Particles. [...]
arXiv:2406.08712.-
2024-08-12 - 15 p.
- Published in : JINST 19 (2024) P08010
Fulltext: 806956891d4956950d85abdbaee8cf0d - PDF; 2406.08712 - PDF; Fulltext from Publisher: PDF; External link: Fermilab Library Server
|
|
5.
|
|
Single channel PICOSEC Micromegas detector with improved time resolution
/ Utrobicic, A. (Boskovic Inst., Zagreb) ; Aleksan, R. (IRFU, Saclay) ; Angelis, Y. (Aristotle U., Thessaloniki) ; Bortfeldt, J. (Munich U.) ; Brunbauer, F. (CERN) ; Brunoldi, M. (Pavia U. ; INFN, Pavia) ; Chatzianagnostou, E. (Aristotle U., Thessaloniki) ; Datta, J. (SUNY, Stony Brook) ; Dehmelt, K. (Jefferson Lab) ; Fanourakis, G. (American Coll. of Greece) et al.
This paper presents design guidelines and experimental verification of a single-channel PICOSEC Micromegas (MM) detector with an improved time resolution. [...]
arXiv:2406.05657 ; FERMILAB-PUB-24-0499-CMS-V.
-
29.
Fermilab Library Server - Fulltext - Fulltext
|
|
6.
|
Towards robust PICOSEC Micromegas precise timing detectors
/ Lisowska, M. (CERN ; IRFU, Saclay) ; Angelis, Y. (Aristotle U., Thessaloniki) ; Aune, S. (IRFU, Saclay) ; Bortfeldt, J. (Munich U.) ; Brunbauer, F. (CERN) ; Chatzianagnostou, E. (Aristotle U., Thessaloniki) ; Dehmelt, K. (SUNY, Stony Brook) ; Desforge, D. (IRFU, Saclay) ; Fanourakis, G. (American Coll. of Greece) ; Floethner, K.J. (CERN ; Bonn U., HISKP) et al.
The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector consisting of a Cherenkov radiator combined with a photocathode and a MM amplifying structure. A 100-channel non-resistive PICOSEC MM prototype with 10x10 cm^2 active area equipped with a Cesium Iodide (CsI) photocathode demonstrated a time resolution below 18 ps. [...]
arXiv:2303.18141; JLAB-PHY-23-3798.-
2023-07-28 - 8 p.
- Published in : JINST
Fulltext: 2303.18141 - PDF; FERMILAB-PUB-23-158-V - PDF; Publication - PDF; External links: JLab Document Server; Fermilab Library Server
In : 7th International Conference on Micro Pattern Gaseous Detectors 2022 (MPGD 2022), Rehovot, Israel, 11 - 16 Dec 2022, pp.C07018
|
|
7.
|
A large area 100-channel PICOSEC Micromegas detector with time resolution at the 20 ps level
/ Utrobicic, A. (Boskovic Inst., Zagreb) ; Angelis, Y. (Aristotle U., Thessaloniki) ; Aune, Stephan ; Bortfeldt, J. (Munich U.) ; Brunbauer, F. (CERN) ; Chatzianagnostou, E. (Aristotle U., Thessaloniki) ; Dehmelt, K. (SUNY, Stony Brook) ; Desforge, Daniel ; Fanourakis, G. (American Coll. of Greece) ; Floethner, K.J. (CERN ; Bonn U., HISKP) et al.
The PICOSEC Micromegas precise timing detector is based on a Cherenkov radiator coupled to a semi-transparent photocathode and a Micromegas amplification structure. The first proof of concept single-channel small area prototype was able to achieve time resolution below 25 ps. [...]
arXiv:2304.00056; FERMILAB-PUB-23-159-V; JLAB-PHY-23-3799.-
2023-07-12 - 10 p.
- Published in : JINST
Fulltext: FERMILAB-PUB-23-159-V - PDF; e11a25382b5d2a8c79973558bc560c53 - PDF; 2304.00056 - PDF; External links: JLab Document Server; Fermilab Library Server
In : 7th International Conference on Micro Pattern Gaseous Detectors 2022 (MPGD 2022), Rehovot, Israel, 11 - 16 Dec 2022
|
|
8.
|
The present and future of QCD
/ Achenbach, P. (Jefferson Lab) ; Adhikari, D. (Virginia Tech.) ; Afanasev, A. (George Washington U. ; Jefferson Lab) ; Afzal, F. (Bonn U., HISKP ; Bonn U.) ; Aidala, C.A. (Michigan U.) ; Al-bataineh, A. (Jordan U. Sci. Tech. ; Yarmouk U. ; Kansas U.) ; Almaalol, D.K. (Illinois U., Urbana ; Illinois U., Urbana (main)) ; Amaryan, M. (Old Dominion U. ; Old Dominion U. (main)) ; Androić, D. (Zagreb U.) ; Armstrong, W.R. (Argonne ; Argonne, PHY) et al.
This White Paper presents the community inputs and scientific conclusions from the Hot and Cold QCD Town Meeting that took place September 23-25, 2022 at MIT, as part of the Nuclear Science Advisory Committee (NSAC) 2023 Long Range Planning process. A total of 424 physicists registered for the meeting. [...]
arXiv:2303.02579; JLAB-PHY-23-3808.-
2024-04-15 - 111 p.
- Published in : Nucl. Phys. A 1047 (2024) 122874
Fulltext: 2303.02579 - PDF; Publication - PDF; External link: JLab Document Server
|
|
9.
|
|
10.
|
|
Recoil imaging for dark matter, neutrinos, and physics beyond the Standard Model
/ O'Hare, C.A.J. (Sydney U. ; ARC, CoEPP, Australia) ; Loomba, D. (New Mexico U.) ; Altenmuller, K. (U. Zaragoza (main)) ; Alvarez-Pol, H. (Santiago de Compostela U., IGFAE) ; Amaro, F.D. (LIP, Coimbra) ; Araujo, H.M. (Imperial Coll., London) ; Aristizabal Sierra, D. (Santa Maria U., Valparaiso ; Liege U.) ; Asaadi, J. (Texas U., Arlington) ; Attie, D. (IRFU, Saclay) ; Aune, S. (IRFU, Saclay) et al.
Recoil imaging entails the detection of spatially resolved ionization tracks generated by particle interactions. [...]
arXiv:2203.05914 ; FERMILAB-CONF-22-334-ND.
-
78 p.
Fermilab Library Server - eConf - Fulltext - Fulltext
|
|