CERN Accelerating science

CERN Document Server Намерени са 42 записа  1 - 10следващкрай  отиване на запис: Търсенето отне 0.65 секунди. 
1.
The ATLAS experiment at the CERN Large Hadron Collider: a description of the detector configuration for Run 3 / ATLAS Collaboration
The ATLAS detector is installed in its experimental cavern at Point 1 of the CERN Large Hadron Collider. During Run 2 of the LHC, a luminosity of $\mathcal{L}=2\times 10^{34}\mathrm{cm}^{-2}\mathrm{s}^{-1}$ was routinely achieved at the start of fills, twice the design luminosity. [...]
arXiv:2305.16623; CERN-EP-2022-259.- Geneva : CERN, 2024-05-23 - 233 p. - Published in : JINST 19 (2024) P05063 Fulltext: 2305.16623 - PDF; document - PDF; External link: Previous draft version
In : The Large Hadron Collider and The Experiments for Run 3
2.
The large inner Micromegas modules for the Atlas Muon Spectrometer Upgrade: construction, quality control and characterization / Allard, J. (IRFU, Saclay) ; Andari, N. (IRFU, Saclay) ; Anfreville, M. (IRFU, Saclay) ; Attié, D. (IRFU, Saclay) ; Aubernon, E. (IRFU, Saclay) ; Aune, S. (IRFU, Saclay) ; Bachacou, H. (IRFU, Saclay) ; Balli, F. (IRFU, Saclay) ; Bauer, F. (IRFU, Saclay) ; Beltramelli, J. (IRFU, Saclay) et al.
The steadily increasing luminosity of the LHC requires an upgrade with high-rate and high-resolution detector technology for the inner end cap of the ATLAS muon spectrometer: the New Small Wheels (NSW). In order to achieve the goal of precision tracking at a hit rate of about 15 kHz/cm$^2$ at the inner radius of the NSW, large area Micromegas quadruplets with 100 \microns spatial resolution per plane have been produced. [...]
arXiv:2105.13709.- 2022-03-01 - 43 p. - Published in : Nucl. Instrum. Methods Phys. Res., A 1026 (2022) 166143 Fulltext: 1-s2.0-S0168900221010330-main - PDF; 2105.13709 - PDF;
3.
A beam-beam monitoring detector for the MPD experiment at NICA / Alvarado, Mauricio (Mexico U., ICN) ; Ayala, Alejandro (Mexico U., ICN) ; Ayala-Torres, Marco Alberto (CINVESTAV, IPN) ; Bietenholz, Wolfgang (Mexico U., ICN ; U. Bern, AEC) ; Dominguez, Isabel (Sinaloa U.) ; Fontaine, Marcos (CINVESTAV, IPN) ; González-Zamora, P. (Puebla U., Mexico) ; Montaño, Luis Manuel (CINVESTAV, IPN) ; Moreno-Barbosa, E. (Puebla U., Mexico) ; Salazar, Miguel Enrique Patiño (Mexico U., ICN) et al.
The Multi-Purpose Detector (MPD) is to be installed at the Nuclotron Ion Collider fAcility (NICA) of the Joint Institute for Nuclear Research (JINR). Its main goal is to study the phase diagram of the strongly interacting matter produced in heavy-ion collisions. [...]
arXiv:1809.10553.- 2020-02-11 - 16 p. - Published in : Nucl. Instrum. Methods Phys. Res., A 953 (2020) 163150 Fulltext: PDF;
4.
STUDY OF THE STABILIZATION TO THE NANOMETER LEVEL OF MECHANICAL VIBRATIONS OF THE CLIC MAIN BEAM QUADRUPOLES   / Artoos, K (CERN) ; Capatina, O (CERN) ; Collette, C (CERN) ; Guinchard, M (CERN) ; Hauviller, C (CERN) ; Lackner, F (CERN) ; Pfingstner, J (CERN) ; Schmickler, H (CERN) ; Sylte, M (CERN) ; Fontaine, M (CEA, France) et al.
WP: 9: Technology for normal conducting higher energy linear accelerators
Task: 9.3: Linac & FF Stabilization

To reach the design luminosity of CLIC, the movements of the quadrupoles should be limited to the nanometre level in order to limit the beam size and emittance growth. [...]
EuCARD-CON-2009-020.
- 2009.
Access to fulltext document
5.
Study of the Stabilization to the Nanometre Level of Mechanical Vibrations of the CLIC Main Beam Quadrupoles / Artoos, K (CERN) ; Capatina, O (CERN) ; Collette, C (CERN) ; Guinchard, M (CERN) ; Hauviller, C (CERN) ; Lackner, F (CERN) ; Pfingstner, J (CERN) ; Schmickler, H (CERN) ; Sylte, M (CERN) ; Fontaine, M (Saclay) et al.
To reach the design luminosity of CLIC, the movements of the quadrupoles should be limited to the nanometre level in order to limit the beam size and emittance growth. Below 1 Hz, the movements of the main beam quadrupoles will be corrected by a beambased feedback. [...]
CERN-ATS-2009-127; CLIC-Note-796.- Geneva : CERN, 2010 - 3 p. Published version from PAC09: PDF;
In : Particle Accelerator Conference 2009, Vancouver, Canada, 04 - 08 May 2009, pp.TH5RFP080
6.
Commissioning of the magnetic field in the ATLAS muon spectrometer / Arnaud, M ; Bardoux, J ; Bergsma, F (CERN) ; Bobbink, G ; Bruni, A ; Chevalier, L ; Ennes, P ; Fleischmann, P ; Fontaine, M ; Formica, A et al.
ATLAS is a general-purpose detector at the 14 TeV proton-proton Large Hadron Collider at CERN. The muon spectrometer will operate in the magnetic field provided by a large, eight-coil barrel toroid magnet bracketed by two smaller toroidal end-caps. [...]
2008 - Published in : Nucl. Phys. B, Proc. Suppl. 177-178 (2008) 265-266
In : Hadron Collider Physics Symposium, La Biodola, Italy, 20 - 26 May 2007, pp.265-266
7.
The alignment system of the barrel part of the ATLAS muon spectrometer / Barriere, J C ; Bauer, F ; Fontaine, M ; Formica, A ; Gautard, V ; Giraud, P F ; Graaf, H ; Guyot, C ; Hart, R ; Horvat, S et al.
The alignment system of the muon spectrometer of the LHC experiment ATLAS is described. [...]
ATL-MUON-PUB-2008-007 ; ATL-COM-MUON-2008-002.
- 2008. - 16 p.
Access to fulltext - Access to fulltext
8.
The ATLAS muon alignment system / Amelung, C (CERN) ; Barriere, J C (CEA-DAPNIA, Saclay, Gif-sur-Yvette, France) ; Bauer, F (CEA-DAPNIA, Saclay, Gif-sur-Yvette, France) ; Bensinger, J (Brandeis University, Waltham, USA) ; Fontaine, M (CEA-DAPNIA, Saclay, Gif-sur-Yvette, France) ; Formica, A (CEA-DAPNIA, Saclay, Gif-sur-Yvette, France) ; Gautard, V (CEA-DAPNIA, Saclay, Gif-sur-Yvette, France) ; Giraud, P F (CEA-DAPNIA, Saclay, Gif-sur-Yvette, France) ; Guyot, C (CEA-DAPNIA, Saclay, Gif-sur-Yvette, France) ; Hart, R (Nikhef, Amsterdam, The Netherlands) et al.
CERN, 2007 - 11 p. Published version from CERN: PDF;
In : 1st LHC Detector Alignment Workshop, CERN, Geneva, Switzerland, 4 - 6 Sep 2006, pp.159-169 (CERN-2007-004)
9.
Optimization of High-Energy Implanter Beamline Pumping / La Fontaine, Marvin ; Pharand, Michel ; Huang, Yongzhang ; Pokidov, Ilya ; Ferrara, Joseph
2006 - Published in : AIP Conf. Proc.: 866 (2006) , pp. 453-456 External link: Published version from AIP
In : 16th International Conference on Ion Implantation Technology, Marseilles, France, 11 - 16 Jun 2006, pp.453-456
10.
Digital Processing of Medical Images Obtained by a Si Microstrips Detector / Díaz, Claudia C ; Montaño, Luis M ; Leyva, Antonio ; Ortiz, Carlos M ; Fontaine, Marcos
2006 - Published in : AIP Conf. Proc.: 854 (2006) , pp. 151-153 External link: Published version from AIP
In : 9th Mexican Symposium on Medical Physics, Guadalajara, Mexico, 18 - 21 Mar 2006, pp.151-153

CERN Document Server : Намерени са 42 записа   1 - 10следващкрай  отиване на запис:
Виж също: автори с подобни имена
1 Fontaine, M.
2 Fontaine, Marcos
1 Fontaine, Mathieu Emmanuel
1 Fontaine, Michael
1 Fontaine, Michel
Интересувате ли се от уведомяване за нови резултати по тази заявка?
Set up a personal email alert or subscribe to the RSS feed.
Не намерихте, каквото търсите? Опитайте търсене в други сървъри:
Fontaine, M в Amazon
Fontaine, M в CERN EDMS
Fontaine, M в CERN Intranet
Fontaine, M в CiteSeer
Fontaine, M в Google Books
Fontaine, M в Google Scholar
Fontaine, M в Google Web
Fontaine, M в IEC
Fontaine, M в IHS
Fontaine, M в INSPIRE
Fontaine, M в ISO
Fontaine, M в KISS Books/Journals
Fontaine, M в KISS Preprints
Fontaine, M в NEBIS
Fontaine, M в SLAC Library Catalog
Fontaine, M в Scirus