CERN Accelerating science

Article
Title Design Parameters of the Normal Conducting Booster Cavity for the PITZ-2 Test Stand
Author(s) Paramonov, V V ; Brusova, N I ; Kvasha, A I ; Menshov, A ; Pronin, O D ; Skasyrskaya, A ; Stepanov, A A
Affiliation (RAS/INR, Moscow DESY Zeuthen, Zeuthen DESY, Hamburg)
Publication 2004
In: 22nd International Linear Accelerator Conference, Lubeck, Germany, 16 - 20 Aug 2004, pp.204
Subject category Accelerators and Storage Rings
Abstract The normal conducting booster cavity is intended to increase the electron bunch energy in the Photo Injector Test (DESY, Zeuthen) stage 2 experiments. The normal conducting cavity is selected due to infrastructure particularities. The L-band cavity is designed to provide the accelerating gradient up to 14 MV/m with the total input RF power 8.6 MW, RF pulse length up to 900 mks and repetition rate 5 Hz. The multi-cell cavity is based on the CDS compensated accelerating structure with the improved coupling coefficient value. The main design ideas and decisions are described briefly together with cavity parameters - RF properties, cooling and pumping circuits.



 Record created 2006-01-31, last modified 2024-02-23


  • Send to ScienceWise.info