Główna > Cyclotron-Injector CI-5 for JINR Phasotron |
Preprint | |
Report number | JINR-P9-2004-170 ; P9-2004-170 |
Title | Cyclotron-Injector CI-5 for JINR Phasotron |
Author(s) | Alenitsky, Yu G ; Vorozhtsov, A S ; Vorozhtsov, S B ; Glazov, A A ; Dmitrievskii, V P ; Zaplatin, N L ; Kalinichenko, V V ; Karamysheva, G A ; Kostromin, S A ; Morozov, N A ; Onishchenko, L M ; Samsonov, E V |
Affiliation | (Dzhelepov Laboratory of Nuclear Problems, Dubna) |
Publication | 2004 |
Imprint | 4 Nov 2004 |
Number of pages | 9 |
Subject category | Accelerators and Storage Rings |
Abstract | The separated sector cyclotron CI-5 with the extraction energy of ?$^-$ ions 5 MeV and beam intensity 10-30 mA for injection into the JINR Phasotron is considered. The results of 3D electromagnetic-field calculations of magnetic and accelerating systems are presented. A number of dynamic simulations taking into account space charge effects using fundamentally different methods confirm that the current limit for separated turns is about 30 mA for this cyclotron. |
Submitted by | [email protected] |