CERN Accelerating science

Article
Report number hep-ex/0111066 ; DESY-2001-188 ; DESY-01-188
Title A Purity Monitoring System for the H1 Liquid Argon Calorimeter
Author(s) Barrelet, E (Paris U., VI-VII)
Publication 2002
Imprint 20 Nov 2001
Number of pages 26
Note Comments: 26 pages, 14 figures
In: Nucl. Instrum. Methods Phys. Res., A 490 (2002) 204-22
DOI 10.1016/S0168-9002(02)00973-7
Subject category Detectors and Experimental Techniques
Accelerator/Facility, Experiment CERN SPS
Abstract The ionization probes used for monitoring the liquid argon purity in the H1 calorimeter are described and results of their operation in tests at CERN and during the period 1992 to the end of 1998 at HERA are given. The high sensitivity of the charge measurements leads to refined charge collection models, and to the observation of a variation of the ionization yield of our electron sources with temperature.

Corresponding record in: Inspire
Email contact: [email protected]


 Записът е създаден на 2001-11-22, последна промяна на 2015-06-26


Access to fulltext document:
Сваляне на пълен текстPDF
External link:
Сваляне на пълен текстhep-ex/0111066 PDF