Начало > CERN Experiments > LHC Experiments > ATLAS > ATLAS Preprints > The Pavia-Romal ATLAS MDT quality control system |
Article | |
Title | The Pavia-Romal ATLAS MDT quality control system |
Author(s) | Bini, C ; Calabro, D ; Cambiaghi, M ; Cardini, A ; Casani, S ; Ferrari, R ; Gaudio, G ; Giacalone, R ; Iuvino, G ; Lacava, F ; Lanza, A ; Locatelli, T ; Montani, L ; Picca, D ; Pinci, D ; Pontecorvo, L ; Prata, M J ; Scagliotti, C |
Affiliation | (Ist Nazionale di Fisica Nucl) |
Publication | 2001 |
In: | Nucl. Instrum. Methods Phys. Res., A 461 (2001) 65-7 |
DOI | 10.1016/S0168-9002(00)01169-4 |
Subject category | Detectors and Experimental Techniques |
Accelerator/Facility, Experiment | CERN LHC ; ATLAS |
Abstract | The physics at LHC imposes very severe requirements on the ATLAS muon detector, which translates into stringent requirements on drift-tubes wire tensioning, leak current, gas leak and wire positioning. In order to verify all these parameters prior to chamber construction, a dedicated quality control system was completely designed and built by our groups. (1 refs). |