Title Radiation Testing of New Readout Electronics for the CMS ECAL Barrel
Author(s) Harringer, Nico (Zurich, ETH) ; Dissertori, Gunther (Zurich, ETH) ; Gadek, Tomasz (Zurich, ETH) ; Wojciech Hajdas ; Haller, Christian (Zurich, ETH) ; Loukas, Nikitas (Notre Dame U.) ; Lustermann, Werner (Zurich, ETH) ; Morvaj, Ljiljana (Boskovic Inst., Zagreb) ; Singovski, Alexander (Notre Dame U.) ; Stachon, Krzysztof (Zurich, ETH)
Publication 2024
Imprint 13 Nov 2024
Number of pages 8
Presented at Topical Workshop on Electronics for Particle Physics 2024, Glasgow, United Kingdom, 30 Sep - 4 Oct 2024
Subject category Detectors and Experimental Techniques
Accelerator/Facility, Experiment CERN LHC ; CMS
Keywords ECAL ; Electronics ; RadiationHardness ; TestBeams
Abstract In preparation of the operation of the CMS electromagnetic calorimeter (ECAL) barrel at the High Luminosity Large Hadron Collider (HL-LHC) the entire on-detector electronics will be replaced. The new readout electronics comprises 12240 very front end (VFE), 2448 front end (FE) and low voltage regulator (LVR) cards arranged into readout towers (RTs) of five VFEs, one FE and one LVR card. The results of testing one RT of final prototype cards at CERN$'$s CHARM mixed field facility and PSI$'$s proton irradiation facility are presented. They demonstrate the proper functioning of the new electronics in the expected radiation conditions.

 