CERN Accélérateur de science

Article
Title Status of the LHC emittance diagnostics
Related titleSTATUS OF THE LHC EMITTANCE DIAGNOSTICS
Author(s) Trad, G (CERN) ; Alexopoulos, A (CERN) ; Baud, G (CERN) ; Bravin, E (CERN) ; Roncarolo, F (CERN) ; Vlachos, S (CERN) ; Wurkner, B (CERN)
Publication 2019
Number of pages 5
In: 8th Evian Workshop on LHC beam operation, Evian Les Bains, France, 12 - 14 Dec 2017, pp.147-151
Subject category Accelerators and Storage Rings
Accelerator/Facility, Experiment CERN LHC
Abstract Measuring the beam transverse emittance is fundamental in every accelerator, in particular for the LHC, where its precise determination and preservation is essential to maximize the luminosity and thus the performance of the colliding beams. In this contribution, a review of the status of the synchrotron radiation monitors, the beam gas vertex detector and the wirescanners will be presented alongside the assessment of the obtained performance. The new features implemented and the issues encountered during 2017's operation will be highlighted. Additionally, the interventions and improvements planned for the coming winter shutdown will be discussed.

Corresponding record in: Inspire


 Notice créée le 2022-06-26, modifiée le 2022-06-26


Fichiers:
Télécharger le document
PDF