CERN Accelerating science

If you experience any problem watching the video, click the download button below
Download Embed
CMS Detector Performance Summaries
Report number CMS-DP-2021-027 ; CERN-CMS-DP-2021-027
Title Analytical Method (AM) for DT Trigger Primitive Generation in Phase 2. Slice Test Results with 2021 cosmics data
Corporate author(s) CMS Collaboration
Publication 2021
Collaboration CMS Collaboration
Imprint 27 Oct 2021
Number of pages 12
Subject category Detectors and Experimental Techniques
Accelerator/Facility, Experiment CERN LHC ; CMS
Keywords Muons
Abstract A full replacement of the muon trigger system in the CMS (Compact Muon Solenoid) detector is envisaged for operating at the maximum instantaneous luminosities expected in HL-LHC (High Luminosity Large Hadron Collider) of about 5-7.5x10$^{34}$cm$^{-2}$s$^{-1}$. Under this scenario, the new on detector electronics that is being designed for the DT (Drift Tubes) detector will forward all the chamber information at its maximum time resolution. A new trigger system based on the highest performing FPGAs is being designed and will be capable of providing precise muon reconstruction and Bunch Crossing identification. An algorithm easily portable to FPGA architecture has been designed to implement the trigger primitive generation from the DT detector. This algorithm has to reconstruct muon segments from single wire DT hits which, for a given BX, come with a spread of 400 ns due to the drift time in the cell. This algorithm provides the maximum resolution achievable by the DT chambers, bringing the hardware system closer to the offline performance capabilities Results from 2021 cosmics data taking in the Slice Test, where a CMS DT sector has been instrumented with HL-LHC DT electronics prototypes running the AM firmware for trigger primitive generation, are presented.

 


 Záznam vytvorený 2021-12-06, zmenený 2021-12-07


Plný text:
Nahraj plný text
PDF