Početna stranica > Beam test of a small MICROMEGAS DHCAL prototype |
Published Articles | |
Title | Beam test of a small MICROMEGAS DHCAL prototype |
Author(s) | Adloff, C (Annecy, LAPP) ; Blaha, J (Annecy, LAPP) ; Chefdeville, M (Annecy, LAPP) ; Dalmaz, A (Annecy, LAPP) ; Drancourt, C (Annecy, LAPP) ; Espargiliere, A (Annecy, LAPP) ; Gaglione, R (Annecy, LAPP) ; Karyotakis, Y (Annecy, LAPP) ; Prast, J (Annecy, LAPP) ; Vouters, G (Annecy, LAPP) |
Publication | 2010 |
Imprint | 2010 |
Number of pages | 14 |
In: | JINST 5 (2010) P01013 |
In: | 1st International Conference on Micro-Pattern Gaseous Detectors, Kolympari, Crete, Greece, 12 - 15 Jun 2009, pp.P01013 |
DOI | 10.1088/1748-0221/5/01/P01013 |
Subject category | Accelerators and Storage Rings |
Accelerator/Facility, Experiment | CERN PS CERN PS |
Test beam | T10 |
Abstract | A sampling hadronic calorimeter with gaps instrumented with thin MICROMEGAS chambers of small pad size and single bit readout is a candidate for an experiment at a future linear collider. Several MICROMEGAS chambers with 1 cm(2) anode pads were fa bricated using the Bulk technology. Some prototypes equipped with analog readout GASSIPLEX chips were developed for characterisation at the CERN/PS facility. A stack of four chambers and stainless steal absorber plates was used to assess the behaviour of MICROMEGAS in 2 GeV/c electron showers. Longitudinal and transverse shower profile are shown. The Bulk fabrication process was adapted to laminate a mesh on anode PCBs with front-end chips connected on the backside. It is well suited for the construction of a 1 m(3) DHCAL MICROMEGAS prototype as large and thin chambers can be made. Such chambers with digital readout chips (HARDROC or DIRAC) were fabricated and tested in a beam. First results are presented. |