Title Radiation tolerance of CVD diamond detectors for pions and protons
Author(s) Adam, W (OAW, Vienna) ; Berdermann, E (Darmstadt, GSI) ; Bergonzo, P (Saclay) ; Bertuccio, G (Milan Polytechnic) ; Bogani, F (Florence U., LENS) ; Borchi, E (U. Florence (main)) ; Brambilla, A (Saclay) ; Bruzzi, M (U. Florence (main)) ; Colledani, C (Louis Pasteur U., Strasbourg I) ; Conway, J (Rutgers U., Piscataway (main)) Visualizza tutti i 72 autori
Collaboration RD42
Publication 2001
Imprint 2002
Number of pages 8
In: Nucl. Instrum. Methods Phys. Res., A
In: 3rd International Conference on Radiation Effects on Semiconductor Material, Detectors and Devices, Florence, Italy, 28 - 30 Jun 2000, pp.686-693
DOI 10.1016/S0168-9002(01)01666-7
Subject category Detectors and Experimental Techniques
Accelerator/Facility, Experiment RD42
Abstract The paper gives new results on the radiation tolerance of CVD diamond for irradiation with 300 MeV/ c pions and 24 GeV/ c protons. The measured charge signal spectrum is compared at several irradiation levels with the spectrum calculated by a model. Irradiation by particles causes damage leading to a decrease of the charge signal. However, both the measurements and the outcome from the model show that for tracker applications this drawback is at least partly counterbalanced by a narrowing of the distribution curve of the charge signal. As a result, the efficiency of a CVD diamond tracker is less affected by irradiation than the mean charge signal.

Corresponding record in: Inspire


 Record creato 2018-08-09, modificato l'ultima volta il 2018-08-10