Author(s)
|
Lechner, A (CERN) ; Barnes, M J (CERN) ; Bartmann, W (CERN) ; Biancacci, N (CERN) ; Bracco, C (CERN) ; Bregliozzi, G (CERN) ; Butcher, M (CERN) ; Muller, J Esteban (CERN) ; Folch, R (CERN) ; Gentini, L (CERN) ; Gilardoni, S (CERN) ; Grudiev, A (CERN) ; Garcia, I Lamas (CERN) ; Losito, R (CERN) ; Masi, A (CERN) ; Metral, E (CERN) ; Marcone, A Perillo (CERN) ; Salvant, B (CERN) ; Taborelli, M (CERN) ; Uythoven, J (CERN) ; Vollenberg, W (CERN) ; Vallgren, C Yin (CERN) |
Abstract
| In Run 1, the LHC injection absorbers (TDIs) were affected by several anomalies
including structural damage of the beam screens and elastic deformations of the
jaws due to heating during fills. Other issues became apparent in 2015, like
excessive vacuum spikes, which gave rise to several beam dumps, as well as
quality issues affecting the hBN absorber blocks. This paper briefly summarizes
past observations and issues like impedance, and describes the modifications
which have been implemented in LS1 and the YETS 2015/2016. In addition, the
expected implications and improvements for operation in 2016 are discussed. |