CERN Accelerating science

CMS Note
Report number CMS-NOTE-2017-007 ; CERN-CMS-NOTE-2017-007
Title The drift velocity monitoring system of the CMS barrel muon chambers
Author(s) Altenhoefer, Georg Friedrich (Julich, Forschungszentrum) ; Hebbeker, Thomas (Aachen, Tech. Hochsch.) ; Heidemann, Carsten Andreas (Aachen, Tech. Hochsch.) ; Reithler, Hans (Aachen, Tech. Hochsch.) ; Sonnenschein, Lars (ADU cologne GmbH, Cologne) ; Teyssier, Daniel Francois (Aachen, Tech. Hochsch.)
Publication 2018
Imprint 18 Jun 2017
Number of pages 8
In: Nucl. Instrum. Methods Phys. Res., A 888 (2018) 1-8
DOI 10.1016/j.nima.2017.12.032
Subject category Detectors and Experimental Techniques
Accelerator/Facility, Experiment CERN LHC ; CMS
Abstract The drift velocity is a key parameter of drift chambers. Its value depends on several parameters: electric field, pressure, temperature, gas mixture, and contamination, for example, by ambient air. A dedicated Velocity Drift Chamber (VDC) with 1-L volume has been built at the III. Phys. Institute A, RWTH Aachen, in order to monitor the drift velocity of all CMS barrel muon Drift Tube chambers. A system of six VDCs was installed at CMS and has been running since January 2011. We present the VDC monitoring system, its principle of operation, and measurements performed.
Copyright/License Preprint: (License: CC-BY-4.0)

Corresponding record in: Inspire


 Zapis kreiran 2017-09-11, zadnja izmjena 2022-07-08


Cjeloviti tekst:
Download fulltext
PDF