CERN Accelerating science

Article
Report number arXiv:1512.00244
Title CHANTI: a Fast and Efficient Charged Particle Veto Detector for the NA62 Experiment at CERN
Author(s) Ambrosino, F. (Naples U. ; INFN, Naples) ; Capussela, T. (Naples U. ; INFN, Naples) ; Di Filippo, D. (Naples U. ; INFN, Naples) ; Massarotti, P. (Naples U. ; INFN, Naples) ; Mirra, M. (Naples U. ; INFN, Naples) ; Napolitano, M. (Naples U. ; INFN, Naples) ; Palladino, V. (Naples U.) ; Saracino, G. (Naples U. ; INFN, Naples) ; Roscilli, L. (Naples U.) ; Vanzanella, A. (Naples U.) ; Corradi, G. (Frascati) ; Tagnani, D. (Frascati) ; Paglia, U. (Frascati)
Publication 2016-03-29
Imprint 01 Dec 2015
Number of pages 18
In: JINST 11 (2016) P03029
DOI 10.1088/1748-0221/11/03/P03029
Subject category Detectors and Experimental Techniques
Accelerator/Facility, Experiment CERN SPS ; NA62
Abstract The design, construction and test of a charged particle detector made of scintillation counters read by Silicon Photomultipliers (SiPM) is described. The detector, which operates in vacuum and is used as a veto counter in the NA62 experiment at CERN, has a single channel time resolution of 1.14 ns, a spatial resolution of  2.5 mm and an efficiency very close to 1 for penetrating charged particles.
Copyright/License arXiv nonexclusive-distrib. 1.0



Corresponding record in: Inspire


 Registre creat el 2015-12-03, darrera modificació el 2021-05-20


Preprint:
Descarregar el text completPDF
Enllaç extern:
Descarregar el text completPreprint