Report number
| arXiv:1208.5690 |
Title
| CAST microbulk micromegas in the Canfranc Underground Laboratory |
Author(s)
|
Tomas, A. ; Aune, S. (IRFU, SPP, Saclay) ; Dafni, T. (Zaragoza U.) ; Fanourakis, G. (Democritos Nucl. Res. Ctr.) ; Ferrer-Ribas, E. (IRFU, SPP, Saclay) ; Galán, J. (Zaragoza U. ; IRFU, SPP, Saclay) ; García, J.A. (Zaragoza U.) ; Gardikiotis, A. (Patras U.) ; Geralis, T. (Patras U.) ; Giomataris, I. (IRFU, SPP, Saclay) ; Gómez, H. (Zaragoza U.) ; Garza, J.G. (Zaragoza U.) ; Herrera, D.C. (Zaragoza U.) ; Iguaz, F.J. (IRFU, SPP, Saclay) ; Irastorza, I.G. (Zaragoza U.) ; Luzón, G. (Zaragoza U.) ; Papaevangelou, T. (IRFU, SPP, Saclay) ; Rodríguez, A. (Zaragoza U.) ; Ruz, J. (CERN) ; Seguí, L. (Zaragoza U.) ; Vafeiadis, T. (Aristotle U., Thessaloniki) ; Yildiz, S.C. (Dogus U., Kadikoy ; Bogazici U.) Mostrar todos los 22 autores |
Publication
| 2013-07-16 |
Imprint
| 29 Aug 2012 |
Number of pages
| 5 |
Note
| Comments: 6 pages, 8 figures. To appear in the proceedings of the 2nd International Conference on Technology and Instrumentation for Particle Physics (TIPP 2011) 6 pages, 8 figures. To appear in the proceedings of the 2nd International Conference on Technology and Instrumentation for Particle Physics (TIPP 2011) |
In:
| Phys. Procedia 37 (2012) 478-482 |
In:
| 2nd International Conference on Technology and Instrumentation in Particle Physics, Chicago, IL, USA, 9 - 14 Jun 2011, pp.478-482 |
DOI
| 10.1016/j.phpro.2012.02.399
|
Subject category
| Detectors and Experimental Techniques |
Accelerator/Facility, Experiment
| CAST |
Abstract
| During the last taking data campaigns of the CAST experiment, the micromegas detectors have achieved background levels of ≈5×10−6keV−1cm−2s−1 between 2 and 9 keV. This performance has been possible thanks to the introduction of the microbulk technology, the implementation of a shielding and the development of discrimination algorithms. It has motivated new studies towards a deeper understanding of CAST detectors background. One of the working lines includes the construction of a replica of the set-up used in CAST by micromegas detectors and its installation in the Canfranc Underground Laboratory. Thanks to the comparison between the performance of the detectors underground and at surface, shielding upgrades, etc, different contributions to the detectors background have been evaluated. In particular, an upper limit <2×10−7keV−1cm−2s−1 for the intrinsic background of the detector has been obtained. This work means a first evaluation of the potential of the newest micromegas technology in an underground laboratory, the most suitable environment for Rare Event Searches. |
Copyright/License
| publication: © 2012-2025 Elsevier (License: CC-BY-NC-ND-3.0) |