CMS Note
Report number CMS-CR-2009-324
Title Design of the CMS-CASTOR sub detector readout system by reusing existing designs
Author(s) Beaumont, Willem (Antwerp U.)
Publication 2009
Collaboration CMS Collaboration
Imprint 19 Oct 2009
Number of pages 7
Presented at Proceedings of the Topical Workshop on Electronics for Particle Physics
Subject category Detectors and Experimental Techniques
Accelerator/Facility, Experiment CERN LHC ; CMS
Keywords Electronics ; General ; HCAL
Abstract CASTOR is a cylindrical calorimeter with a length of 1.5m and a diameter of 60cm located at 14.3 meters from the CMS interaction point and covering the range in pseudo-rapidity corresponding to 5.1  \textless  \textbar  eta  \textbar   \textless   6.6. The CASTOR project was approved in the middle of 2007. Given the limited resources and time, developing a readout system from scratch was excluded. Here the final implementations of the readout chain, the considerations for the different choices as well as the performance of the installed equipment are discussed.
Copyright/License Preprint: (License: CC-BY-4.0)

 