CERN Accelerating science

ATLAS Note
Report number ATL-INDET-PROC-2009-006 ; ATL-COM-INDET-2009-024
Title The Data Acquisition and Calibration System for the ATLAS Semiconductor Tracker
Author(s) Barber, TJ (Cambridge U. (main))
Corporate Author(s) The ATLAS collaboration
Publication 2009
Imprint 08 Jun 2009
Number of pages 7
Note June 14th 2009
In: 16th IEEE NPSS Real Time Conference 2009, Beijing, China, 10 - 15 May 2009
Subject category Detectors and Experimental Techniques
Accelerator/Facility, Experiment CERN LHC ; ATLAS
Free keywords Silicon Detector ; Data Acquisition
Abstract The Semiconductor Tracker (SCT) data acquisition (DAQ) system has been built to calibrate, configure, and control the approximately six million front-end channels of the ATLAS silicon strip detector. It provides a synchronized bunch-crossing clock to the frontend modules, communicates first-level triggers to the front-end chips, and transfers information about hit strips to the ATLAS high-level trigger system. The system has been used extensively for calibration and quality assurance during SCT barrel and endcap assembly and for performance confirmation tests after transport of the barrels and endcaps to CERN. Operating in data-taking mode, the DAQ has recorded millions of synchronously-triggered events during commissioning tests including cosmic ray triggered events both in standalone and ATLAS-wide mode. In this paper we describe the components of the data acquisition system, discuss its operation in calibration and data-taking modes and present some detector performance results from these tests.
Copyright/License Preprint: (License: CC-BY-4.0)

Corresponding record in: Inspire


 Δημιουργία εγγραφής 2009-06-08, τελευταία τροποποίηση 2018-05-29


Πλήρες κείμενο:
Κατέβασμα πλήρες κειμένου