Skip to main content

Showing 1–19 of 19 results for author: Pitters, F

Searching in archive physics. Search in all archives.
.
  1. arXiv:2209.13676  [pdf, other

    physics.med-ph physics.ins-det

    Novel ion imaging concept based on time-of-flight measurements with low gain avalanche detectors

    Authors: Felix Ulrich-Pur, Thomas Bergauer, Albert Hirtl, Christian Irmler, Stefanie Kaser, Florian Pitters, Simon Rit

    Abstract: Treatment planning in ion beam therapy requires accurate knowledge of the relative stopping power (RSP) distribution within the patient. Currently, RSP maps are obtained via conventional x-ray computed tomography (CT) by converting the measured attenuation coefficients of photons into RSP values for ions. Alternatively, to avoid conversion errors that are inherent to this method, ion computed tomo… ▽ More

    Submitted 27 September, 2022; originally announced September 2022.

  2. arXiv:2111.06855  [pdf, other

    physics.ins-det hep-ex

    Response of a CMS HGCAL silicon-pad electromagnetic calorimeter prototype to 20-300 GeV positrons

    Authors: B. Acar, G. Adamov, C. Adloff, S. Afanasiev, N. Akchurin, B. Akgün, F. Alam Khan, M. Alhusseini, J. Alison, A. Alpana, G. Altopp, M. Alyari, S. An, S. Anagul, I. Andreev, P. Aspell, I. O. Atakisi, O. Bach, A. Baden, G. Bakas, A. Bakshi, S. Bannerjee, P. Bargassa, D. Barney, F. Beaudette , et al. (364 additional authors not shown)

    Abstract: The Compact Muon Solenoid Collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section consisting of 14 double-sided structures, providing 28 sampling layers. Each sampling layer has an hexagonal module, where a multipad large-area silicon sensor is glu… ▽ More

    Submitted 31 March, 2022; v1 submitted 12 November, 2021; originally announced November 2021.

  3. Feasibility study of a proton CT system based on 4D-tracking and residual energy determination via time-of-flight

    Authors: Felix Ulrich-Pur, Thomas Bergauer, Alexander Burker, Albert Hirtl, Christian Irmler, Stefanie Kaser, Florian Pitters, Simon Rit

    Abstract: For dose calculations in ion beam therapy, it is vital to accurately determine the relative stopping power (RSP) distribution within the treated volume. Currently, RSP values are extrapolated from Hounsfield units (HU), measured with x-ray computed tomography (CT), which entails RSP inaccuracies due to conversion errors. A suitable method to improve the treatment plan accuracy is proton computed t… ▽ More

    Submitted 10 September, 2021; originally announced September 2021.

    Comments: Preprint submitted to Physics in Medicine and Biology. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it

  4. A Proton Computed Tomography Demonstrator for Stopping Power Measurements

    Authors: Felix Ulrich-Pur, Thomas Bergauer, Alexander Burker, Albert Hirtl, Christian Irmler, Stefanie Kaser, Florian Pitters

    Abstract: Particle therapy is an established method to treat deep-seated tumours using accelerator-produced ion beams. For treatment planning, the precise knowledge of the relative stopping power (RSP) within the patient is vital. Conversion errors from x-ray computed tomography (CT) measurements to RSP introduce uncertainties in the applied dose distribution. Using a proton computed tomography (pCT) system… ▽ More

    Submitted 24 June, 2021; originally announced June 2021.

    Comments: Preprint submitted to the open-access Journal of Physics: Conference Series. (TIPP2021 conference proceedings). IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it

  5. arXiv:2102.06240  [pdf, other

    physics.acc-ph physics.med-ph

    Commissioning of low particle flux for proton beams at MedAustron

    Authors: Felix Ulrich-Pur, Laurids Adler, Thomas Bergauer, Alexander Burker, Andrea De Franco, Greta Guidoboni, Albert Hirtl, Christian Irmler, Stefanie Kaser, Sebastian Nowak, Florian Pitters, Mauro Pivi, Dale Prokopovich, Claus Schmitzer, Alexander Wastl

    Abstract: MedAustron is a synchrotron-based particle therapy centre located in Wiener Neustadt, Austria. It features three irradiation rooms for particle therapy, where proton beams with energies up to 252.7 MeV and carbon ions of up to 402.8 MeV/u are available for cancer treatment. In addition to the treatment rooms, MedAustron features a unique beamline exclusively for non-clinical research (NCR). This r… ▽ More

    Submitted 27 May, 2021; v1 submitted 11 February, 2021; originally announced February 2021.

    Comments: Preprint submitted to NIM A (first revision)

  6. arXiv:2012.06336  [pdf, other

    physics.ins-det hep-ex

    Construction and commissioning of CMS CE prototype silicon modules

    Authors: B. Acar, G. Adamov, C. Adloff, S. Afanasiev, N. Akchurin, B. Akgün, M. Alhusseini, J. Alison, G. Altopp, M. Alyari, S. An, S. Anagul, I. Andreev, M. Andrews, P. Aspell, I. A. Atakisi, O. Bach, A. Baden, G. Bakas, A. Bakshi, P. Bargassa, D. Barney, E. Becheva, P. Behera, A. Belloni , et al. (307 additional authors not shown)

    Abstract: As part of its HL-LHC upgrade program, the CMS Collaboration is developing a High Granularity Calorimeter (CE) to replace the existing endcap calorimeters. The CE is a sampling calorimeter with unprecedented transverse and longitudinal readout for both electromagnetic (CE-E) and hadronic (CE-H) compartments. The calorimeter will be built with $\sim$30,000 hexagonal silicon modules. Prototype modul… ▽ More

    Submitted 10 December, 2020; originally announced December 2020.

    Comments: 35 pages, submitted to JINST

  7. arXiv:2012.03876  [pdf, other

    physics.ins-det hep-ex

    The DAQ system of the 12,000 Channel CMS High Granularity Calorimeter Prototype

    Authors: B. Acar, G. Adamov, C. Adloff, S. Afanasiev, N. Akchurin, B. Akgün, M. Alhusseini, J. Alison, G. Altopp, M. Alyari, S. An, S. Anagul, I. Andreev, M. Andrews, P. Aspell, I. A. Atakisi, O. Bach, A. Baden, G. Bakas, A. Bakshi, P. Bargassa, D. Barney, E. Becheva, P. Behera, A. Belloni , et al. (307 additional authors not shown)

    Abstract: The CMS experiment at the CERN LHC will be upgraded to accommodate the 5-fold increase in the instantaneous luminosity expected at the High-Luminosity LHC (HL-LHC). Concomitant with this increase will be an increase in the number of interactions in each bunch crossing and a significant increase in the total ionising dose and fluence. One part of this upgrade is the replacement of the current endca… ▽ More

    Submitted 8 December, 2020; v1 submitted 7 December, 2020; originally announced December 2020.

  8. Corryvreckan: A Modular 4D Track Reconstruction and Analysis Software for Test Beam Data

    Authors: Dominik Dannheim, Katharina Dort, Lennart Huth, Daniel Hynds, Iraklis Kremastiotis, Jens Kröger, Magdalena Munker, Florian Pitters, Paul Schütze, Simon Spannagel, Tomas Vanat, Morag Williams

    Abstract: Corryvreckan is a versatile, highly configurable software with a modular structure designed to reconstruct and analyse test beam and laboratory data. It caters to the needs of the test beam community by providing a flexible offline event building facility to combine detectors with different read-out schemes, with or without trigger information, and includes the possibility to correlate data from m… ▽ More

    Submitted 13 January, 2021; v1 submitted 25 November, 2020; originally announced November 2020.

    Report number: CLICdp-Pub-2020-005

  9. arXiv:2008.08422  [pdf, other

    physics.med-ph physics.ins-det

    Single particle tracking uncertainties in ion imaging

    Authors: A. Burker, T. Bergauer, A. Hirtl, C. Irmler, S. Kaser, B. Knäusl, F. Pitters, F. Ulrich-Pur

    Abstract: An extensive comparison of the path uncertainty in single particle tracking systems for ion imaging was carried out based on Monte Carlo simulations. The spatial resolution as function of system parameters such as geometry, detector properties and the energy of proton and helium beams was investigated to serve as a guideline for hardware developments. Primary particle paths were sampled within a… ▽ More

    Submitted 22 February, 2021; v1 submitted 19 August, 2020; originally announced August 2020.

    Comments: 19 pages, 6 figures, submitted to Phys. Med. Biol

  10. Charge Collection and Electrical Characterization of Neutron Irradiated Silicon Pad Detectors for the CMS High Granularity Calorimeter

    Authors: N. Akchurin, P. Almeida, G. Altopp, M. Alyari, T. Bergauer, E. Brondolin, B. Burkle, W. D. Frey, Z. Gecse, U. Heintz, N. Hinton, V. Kuryatkov, R. Lipton, M. Mannelli, T. Mengke, P. Paulitsch, T. Peltola, F. Pitters, E. Sicking, E. Spencer, M. Tripathi, M. Vicente Barreto Pinto, J. Voelker, Z. Wang, R. Yohay

    Abstract: The replacement of the existing endcap calorimeter in the Compact Muon Solenoid (CMS) detector for the high-luminosity LHC (HL-LHC), scheduled for 2027, will be a high granularity calorimeter. It will provide detailed position, energy, and timing information on electromagnetic and hadronic showers in the immense pileup of the HL-LHC. The High Granularity Calorimeter (HGCAL) will use 120-, 200-, an… ▽ More

    Submitted 4 August, 2020; v1 submitted 16 May, 2020; originally announced May 2020.

    Comments: 36 pages, 34 figures

  11. arXiv:2003.00115  [pdf, other

    physics.ins-det physics.med-ph

    Imaging with protons at MedAustron

    Authors: F. Ulrich-Pur, T. Bergauer, A. Burker, S. Hatamikia, A. Hirtl, C. Irmler, S. Kaser, P. Paulitsch, F. Pitters, V. Teufelhart

    Abstract: Ion beam therapy has become a frequently applied form of cancer therapy over the last years. The advantage of ion beam therapy over conventional radiotherapy using photons is the strongly localized dose deposition, leading to a reduction of dose applied to surrounding healthy tissue. Currently, treatment planning for proton therapy is based on X-ray computed tomography, which entails certain sourc… ▽ More

    Submitted 15 July, 2020; v1 submitted 28 February, 2020; originally announced March 2020.

    Comments: 7 pages, 11 figures, proceedings of the "HSTD12: 12th International "Hiroshima" Symposium on the Development and Application of Semiconductor Tracking Detectors (HSTD12)", 14-18 Dec 2019, Hiroshima (Japan), to be submitted to Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

  12. Detector Technologies for CLIC

    Authors: A. C. Abusleme Hoffman, G. Parès, T. Fritzsch, M. Rothermund, H. Jansen, K. Krüger, F. Sefkow, A. Velyka, J. Schwandt, I. Perić, L. Emberger, C. Graf, A. Macchiolo, F. Simon, M. Szalay, N. van der Kolk, H. Abramowicz, Y. Benhammou, O. Borysov, M. Borysova, A. Joffe, S. Kananov, A. Levy, I. Levy, G. Eigen , et al. (107 additional authors not shown)

    Abstract: The Compact Linear Collider (CLIC) is a high-energy high-luminosity linear electron-positron collider under development. It is foreseen to be built and operated in three stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. It offers a rich physics program including direct searches as well as the probing of new physics through a broad set of precision measurements of Stan… ▽ More

    Submitted 7 May, 2019; originally announced May 2019.

    Comments: 152 pages, 116 figures; published as CERN Yellow Report Monograph Vol. 1/2019; corresponding editors: Dominik Dannheim, Katja Krüger, Aharon Levy, Andreas Nürnberg, Eva Sicking

    Report number: CERN-2019-001

  13. ARRAY: An Open Source, Modular and Probe-Card based System with Integrated Switching Matrix for Characterisation of Large Area Silicon Pad Sensors

    Authors: Erica Brondolin, Dominik Dannheim, Szymon Kulis, Andreas A. Maier, Florian Pitters, Thorben Quast, Eva Sicking

    Abstract: Silicon pad sensors are proposed as active material in highly granular sampling calorimeters of future collider experiments such as the Compact Linear Collider (CLIC) or the International Linear Collider (ILC). The electromagnetic section of these designs often include O(1000 m$^2$) of silicon pad sensors. For the luminosity measurement, a dedicated forward calorimeter called LumiCal is foreseen.… ▽ More

    Submitted 26 February, 2021; v1 submitted 25 March, 2019; originally announced March 2019.

    Comments: preprint submitted to NIM A, version 2

  14. Time Resolution Studies with Timepix3 Assemblies with Thin Silicon Pixel Sensors

    Authors: Florian Pitters, Nilou Alipour Tehrani, Dominik Dannheim, Adrian Fiergolski, Daniel Hynds, Wolfgang Klempt, Xavi Llopart, Magdalena Munker, Andreas Nürnberg, Simon Spannagel, Morag Williams

    Abstract: Timepix3 is a multi-purpose readout ASIC for hybrid pixel detectors. It can measure time and energy simultaneously by employing time-of-arrival (ToA) and time-over-threshold (ToT) techniques. Both methods are systematically affected by timewalk. In this paper, a method for pixel-by-pixel calibration of the time response is presented. Assemblies of Timepix3 ASICs bump-bonded to thin planar silicon… ▽ More

    Submitted 10 March, 2019; v1 submitted 21 January, 2019; originally announced January 2019.

    Comments: preprint submitted to JINST, revision 1

  15. arXiv:1812.07337  [pdf, other

    physics.ins-det hep-ex

    A detector for CLIC: main parameters and performance

    Authors: Dominik Arominski, Jean-Jacques Blaising, Erica Brondolin, Dominik Dannheim, Konrad Elsener, Frank Gaede, Ignacio García-García, Steven Green, Daniel Hynds, Emilia Leogrande, Lucie Linssen, John Marshall, Nikiforos Nikiforou, Andreas Nürnberg, Estel Perez-Codina, Marko Petrič, Florian Pitters, Aidan Robson, Philipp Roloff, André Sailer, Ulrike Schnoor, Frank Simon, Rosa Simoniello, Simon Spannagel, Rickard Ström , et al. (3 additional authors not shown)

    Abstract: Together with the recent CLIC detector model CLICdet a new software suite was introduced for the simulation and reconstruction of events in this detector. This note gives a brief introduction to CLICdet and describes the CLIC experimental conditions at 380 GeV and 3 TeV, including beam-induced backgrounds. The simulation and reconstruction tools are introduced, and the physics performance obtained… ▽ More

    Submitted 18 December, 2018; originally announced December 2018.

    Report number: CLICdp-Note-2018-005

  16. The Compact Linear Collider (CLIC) - 2018 Summary Report

    Authors: The CLIC, CLICdp collaborations, :, T. K. Charles, P. J. Giansiracusa, T. G. Lucas, R. P. Rassool, M. Volpi, C. Balazs, K. Afanaciev, V. Makarenko, A. Patapenka, I. Zhuk, C. Collette, M. J. Boland, A. C. Abusleme Hoffman, M. A. Diaz, F. Garay, Y. Chi, X. He, G. Pei, S. Pei, G. Shu, X. Wang, J. Zhang , et al. (671 additional authors not shown)

    Abstract: The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the… ▽ More

    Submitted 6 May, 2019; v1 submitted 14 December, 2018; originally announced December 2018.

    Comments: 112 pages, 59 figures; published as CERN Yellow Report Monograph Vol. 2/2018; corresponding editors: Philip N. Burrows, Nuria Catalan Lasheras, Lucie Linssen, Marko Petrič, Aidan Robson, Daniel Schulte, Eva Sicking, Steinar Stapnes

    Report number: CERN-2018-005-M

  17. The CLIC Detector Concept

    Authors: Florian Pitters

    Abstract: The Compact Linear Collider (CLIC) is a concept for a future linear collider that would provide e$^+$e$^-$ collisions at up to 3 TeV. The physics aims require a detector system with excellent jet energy and track momentum resolution, highly efficient flavour tagging and lepton identification capabilities, full geometrical coverage extending to low polar angles, and timing information of the order… ▽ More

    Submitted 16 February, 2018; originally announced February 2018.

    Journal ref: CERN-Proceedings-2017-001 (CERN, Geneva, 2017), pp. 37-44

  18. arXiv:1802.05987  [pdf, other

    physics.ins-det hep-ex

    The CMS High-Granularity Calorimeter for Operation at the High-Luminosity LHC

    Authors: Florian Pitters

    Abstract: The High Luminosity LHC (HL-LHC) will integrate 10 times more luminosity than the LHC, posing significant challenges for radiation tolerance and event pileup on detectors, especially for forward calorimetry, and hallmarks the issue for future colliders. As part of its HL-LHC upgrade program, the CMS collaboration is designing a High Granularity Calorimeter to replace the existing endcap calorimete… ▽ More

    Submitted 16 February, 2018; originally announced February 2018.

  19. arXiv:1608.07537  [pdf, other

    physics.acc-ph hep-ex

    Updated baseline for a staged Compact Linear Collider

    Authors: The CLIC, CLICdp collaborations, :, M. J. Boland, U. Felzmann, P. J. Giansiracusa, T. G. Lucas, R. P. Rassool, C. Balazs, T. K. Charles, K. Afanaciev, I. Emeliantchik, A. Ignatenko, V. Makarenko, N. Shumeiko, A. Patapenka, I. Zhuk, A. C. Abusleme Hoffman, M. A. Diaz Gutierrez, M. Vogel Gonzalez, Y. Chi, X. He, G. Pei, S. Pei, G. Shu , et al. (493 additional authors not shown)

    Abstract: The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-q… ▽ More

    Submitted 27 March, 2017; v1 submitted 26 August, 2016; originally announced August 2016.

    Comments: 57 pages, 27 figures, 12 tables, published as CERN Yellow Report. Updated version: Minor layout changes for print version

    Report number: CERN-2016-004