Skip to main content

Showing 1–7 of 7 results for author: Nogiec, J

Searching in archive physics. Search in all archives.
.
  1. arXiv:2312.08166  [pdf

    physics.acc-ph

    Magnetic Measurements and Alignment Results of LQXFA/B Cold Mass Assemblies at Fermilab

    Authors: J. DiMarco, P. Akella, G. Ambrosio, M. Baldini, G. Chlachidze, S. Feher, J. Nogiec, V. Nikolic, S. Stoynev, T. Strauss, M. Tartaglia, P. Thompson, D. Walbridge

    Abstract: MQXFA production series quadrupole magnets are being built for the Hi-Lumi (HL) LHC upgrade by the US Accelerator Upgrade Project (US-HL-LHC AUP). These magnets are being placed in pairs, as a cold mass, within cryostats at Fermilab, and are being tested to assess alignment and magnetic performance at Fermilab's horizontal test stand facility. The ~10 m - long assembly must meet stringent specific… ▽ More

    Submitted 13 December, 2023; originally announced December 2023.

    Comments: 28th International Conference on Magnet Technology (MT-28)

    Report number: FERMILAB-CONF-23-791-TD

  2. Designing a Magnetic Measurement Data Acquisition and Control System with Reuse in Mind: A Rotating Coil System Example

    Authors: J. M. Nogiec, P. Akella, G. Chlachidze, J. DiMarco, M. Tartaglia, P. Thompson, K. Trombly-Freytag, D. Walbridge

    Abstract: Accelerator magnet test facilities frequently need to measure different magnets on differently equipped test stands and with different instrumentation. Designing a modular and highly reusable system that combines flexibility built-in at the architectural level as well as on the component level addresses this need. Specification of the backbone of the system, with the interfaces and dataflow for so… ▽ More

    Submitted 14 December, 2021; originally announced December 2021.

    Report number: FERMILAB-CONF-21-671-TD

  3. Magnetic Measurements of HL-LHC AUP Cryo-Assemblies at Fermilab

    Authors: J. DiMarco, P. Akella, G. Ambrosio, D. Assell, M. Baldini, G. Chlachidze, S. Feher, J. Nogiec, V. Nikolic, S. Stoynev, T. Strauss, M. Tartaglia, P. Thompson, D. Walbridge, W. Ghiorso, X. Wang

    Abstract: LQXFA/B production series cryogenic assemblies are being built for the LHC upgrade by the HL-LHC Accelerator Upgrade Project (AUP). These contain a pair of MQXFA quadrupole magnets combined as a cold mass within a vacuum vessel, and are to be installed in the IR regions of the LHC. The LQXFA/B are being tested at 1.9 K to assess alignment and magnetic performance at Fermilab's horizontal test faci… ▽ More

    Submitted 14 December, 2021; originally announced December 2021.

    Comments: 27th Intl Conf on Magnet Technology (MT27)

    Report number: FERMILAB-CONF-21-688-TD

  4. A Quench Detection and Monitoring System for Superconducting Magnets at Fermilab

    Authors: A. Galt, O. Al Atassi, G. Chlachidze, T. Cummings, S. Feher, A. Hocker, S. Kotelnikov, M. Lamm, A. Makulski, J. Nogiec, D. Orris, R. Pilipenko, M. Tartaglia

    Abstract: A quench detection system was developed for protecting and monitoring the superconducting solenoids for the Muon-to-Electron Conversion Experiment (Mu2e) at Fermilab. The quench system was designed for a high level of dependability and long-term continuous operation. It is based on three tiers: Tier-I, FPGA-based Digital Quench Detection (DQD); Tier-II, Analog Quench Detection (AQD); and Tier-3, t… ▽ More

    Submitted 1 December, 2021; originally announced December 2021.

    Report number: FERMILAB-PUB-21-637-SQMS-TD

  5. arXiv:1501.05241  [pdf

    physics.ins-det hep-ex

    Mu2e Technical Design Report

    Authors: L. Bartoszek, E. Barnes, J. P. Miller, J. Mott, A. Palladino, J. Quirk, B. L. Roberts, J. Crnkovic, V. Polychronakos, V. Tishchenko, P. Yamin, C. -h. Cheng, B. Echenard, K. Flood, D. G. Hitlin, J. H. Kim, T. S. Miyashita, F. C. Porter, M. Röhrken, J. Trevor, R. -Y. Zhu, E. Heckmaier, T. I. Kang, G. Lim, W. Molzon , et al. (238 additional authors not shown)

    Abstract: The Mu2e experiment at Fermilab will search for charged lepton flavor violation via the coherent conversion process mu- N --> e- N with a sensitivity approximately four orders of magnitude better than the current world's best limits for this process. The experiment's sensitivity offers discovery potential over a wide array of new physics models and probes mass scales well beyond the reach of the L… ▽ More

    Submitted 16 March, 2015; v1 submitted 21 January, 2015; originally announced January 2015.

    Comments: compressed file, 888 pages, 621 figures, 126 tables; full resolution available at http://mu2e.fnal.gov; corrected typo in background summary, Table 3.4

    Report number: Fermilab-TM-2594 , Fermilab-DESIGN-2014-1

  6. arXiv:physics/0111044  [pdf

    physics.ins-det physics.comp-ph

    An XML Driven Framework for Test Control and Data Analysis

    Authors: J. M. Nogiec, K. Trombly-Freytag, D. Walbridge, E. Desavouret

    Abstract: An extensible, component-based framework has been developed at Fermilab to promote software reuse and provide a common platform for developing a family of test and data analysis systems. The framework allows for configuring applications from components through the use of XML configurations. It can be easily extended by adding new components and many application independent components are already… ▽ More

    Submitted 12 November, 2001; v1 submitted 9 November, 2001; originally announced November 2001.

    Comments: ICALEPCS 2001, November 2001, (THAP073) 3 pages, PDF

    Journal ref: eConf C011127 (2001) THAP073

  7. arXiv:physics/0111026  [pdf

    physics.ins-det

    Distributed Power Supply Control and Monitoring System

    Authors: J. M. Nogiec, E. Desavouret

    Abstract: An extensible power supply control and monitoring system has been developed at Fermilab's Technical Division as a result of requirements to control and monior power supplies of various types from within many different applications. This system, deployed as a network service, provides uniform programming and user interfaces for various types of power supplies, ranging from 20A to 30kA. It allows… ▽ More

    Submitted 7 November, 2001; originally announced November 2001.

    Comments: ICALEPCS 2001, San Jose, November 2001, (THAP072) 3 pages, PDF

    Journal ref: eConf C011127 (2001) THAP072