Skip to main content

Showing 1–50 of 59 results for author: Kapłon, Ł

Searching in archive physics. Search in all archives.
.
  1. arXiv:2408.00574  [pdf

    physics.med-ph

    Investigation of Novel Preclinical Total Body PET Designed With J-PET Technology:A Simulation Study

    Authors: M. Dadgar, S. Parzych, F. Tayefi Ardebili, J. Baran, N. Chug, C. Curceanu, E. Czerwinski, K. Dulski, K. Eliyan, A. Gajos, B. C. Hiesmayr, K. Kacprzak, L. Kaplon, K. Klimaszewski, P. Konieczka, G. Korcyl, T. Kozik, W. Krzemien, D. Kumar, S. Niedzwiecki, D. Panek, E. Perez del Rio, L. Raczynski, S. Sharma, Shivani , et al. (7 additional authors not shown)

    Abstract: The growing interest in human-grade total body positron emission tomography (PET) systems has also application in small animal research. Due to the existing limitations in human-based studies involving drug development and novel treatment monitoring, animal-based research became a necessary step for testing and protocol preparation. In this simulation-based study two unconventional, cost-effective… ▽ More

    Submitted 6 August, 2024; v1 submitted 1 August, 2024; originally announced August 2024.

  2. arXiv:2407.19465  [pdf

    physics.ins-det nucl-ex

    Comparative studies of plastic scintillator strips with high technical attenuation length for the total-body J-PET scanner

    Authors: L. Kaplon, J. Baran, N. Chug, A. Coussat, C. Curceanu, E. Czerwinski, M. Dadgar, K. Dulski, J. Gajewski, A. Gajos, B. Hiesmayr, E. Kavya Valsan, K. Klimaszewski, G. Korcyl, T. Kozik, W. Krzemien, D. Kumar, G. Moskal, S. Niedzwiecki, D. Panek, S. Parzych, E. Perez del Rio, L. Raczynski, A. Rucinski, S. Sharma , et al. (9 additional authors not shown)

    Abstract: Plastic scintillator strips are considered as one of the promising solutions for the cost-effective construction of total-body positron emission tomography, (PET) system. The purpose of the performed measurements is to compare the transparency of long plastic scintillators with dimensions 6 mm x 24 mm x 1000 mm and with all surfaces polished. Six different types of commercial, general purpose, blu… ▽ More

    Submitted 3 August, 2024; v1 submitted 28 July, 2024; originally announced July 2024.

    Comments: 10 pages, 5 figures

    Journal ref: Nuclear Inst. and Methods in Physics Research, A 1051 (2023) 168186

  3. arXiv:2407.08574  [pdf, other

    nucl-ex physics.med-ph quant-ph

    Non-maximal entanglement of photons from positron-electron annihilation demonstrated using a novel plastic PET scanner

    Authors: P. Moskal, D. Kumar, S. Sharma, E. Y. Beyene, N. Chug, A. Coussat, C. Curceanu, E. Czerwinski, M. Das, K. Dulski, M. Gorgol, B. Jasinska, K. Kacprzak, T. Kaplanoglu, L. Kaplon, K. Klimaszewski, T. Kozik, E. Lisowski, F. Lisowski, W. Mryka, S. Niedzwiecki, S. Parzych, E. P. del Rio, L. Raczynski, M. Radler , et al. (7 additional authors not shown)

    Abstract: In the state-of-the-art Positron Emission Tomography (PET), information about the polarization of annihilation photons is not available. Current PET systems track molecules labeled with positron-emitting radioisotopes by detecting the propagation direction of two photons from positron-electron annihilation. However, annihilation photons carry more information than just the site where they originat… ▽ More

    Submitted 11 July, 2024; originally announced July 2024.

  4. arXiv:2309.07171  [pdf, other

    physics.ins-det nucl-ex

    Feasibility studies for imaging e$^{+}$e$^{-}$ annihilation with modular multi-strip detectors

    Authors: S. Sharma, L. Povolo, S. Mariazzi, G. Korcyl, K. Kacprzak, D. Kumar, S. Niedzwiecki, J. Baran, E. Beyene, R. S. Brusa, R. Caravita, N. Chug, A. Coussat, C. Curceanu, E. Czerwinski, M. Dadgar, M. Das, K. Dulski, K. Eliyan, A. Gajos, N. Gupta, B. C. Hiesmayr, L. Kaplon, T. Kaplanoglu, K. Klimaszewski , et al. (19 additional authors not shown)

    Abstract: Studies based on imaging the annihilation of the electron (e$^{-}$) and its antiparticle positron (e$^{+}$) open up several interesting applications in nuclear medicine and fundamental research. The annihilation process involves both the direct conversion of e$^{+}$e$^{-}$ into photons and the formation of their atomically bound state, the positronium atom (Ps), which can be used as a probe for fu… ▽ More

    Submitted 12 September, 2023; originally announced September 2023.

  5. arXiv:2304.05834  [pdf

    physics.med-ph

    Comparative studies of the sensitivities of sparse and full geometries of Total-Body PET scanners built from crystals and plastic scintillators

    Authors: Meysam Dadgar, Szymon Parzych, Jakub Baran, Neha Chug, Catalina Curceanu, Eryk Czerwiński, Kamil Dulski, Kavya Elyan, Aleksander Gajos, Beatrix Hiesmayr, Łukasz Kapłon, Konrad Klimaszewski, Paweł Konieczka, Grzegorz Korcyl, Tomasz Kozik, Wojciech Krzemień, Deepak Kumar, Szymon Niedźwiecki, Domonik Panek, Eleną Perez del Rio, Lech Raczyński, Sushil Sharma, Shivani, Roman Shopa, Magdalena Skurzok , et al. (6 additional authors not shown)

    Abstract: Background: Total-Body imaging offers high sensitivity, single-bed position, and low dose, but high construction costs limit worldwide utilization. This study compares existing and developing tomographs using plastic scintillators via simulations to propose a cost-efficient Total-Body PET scanner. Methods: Simulations of eight uEXPLORER tomographs with different scintillator materials, axial fie… ▽ More

    Submitted 12 April, 2023; originally announced April 2023.

  6. arXiv:2302.14359  [pdf, other

    physics.med-ph

    Feasibility of the J-PET to monitor range of therapeutic proton beams

    Authors: Jakub Baran, Damian Borys, Karol Brzeziński, Jan Gajewski, Michał Silarski, Neha Chug, Aurélien Coussat, Eryk Czerwiński, Meysam Dadgar, Kamil Dulski, Kavya V. Eliyan, Aleksander Gajos Krzysztof Kacprzak, Łukasz Kapłon, Konrad Klimaszewski, Paweł Konieczka, Renata Kopeć, Grzegorz Korcyl, Tomasz Kozik, Wojciech Krzemień, Deepak Kumar, Antony J. Lomax, Keegan McNamara, Szymon Niedźwiecki, Paweł Olko, Dominik Panek , et al. (18 additional authors not shown)

    Abstract: Objective: The aim of this work is to investigate the feasibility of the Jagiellonian Positron Emission Tomography (J-PET) scanner for intra-treatment proton beam range monitoring. Approach: The Monte Carlo simulation studies with GATE and PET image reconstruction with CASToR were performed in order to compare six J-PET scanner geometries (three dual-heads and three cylindrical). We simulated prot… ▽ More

    Submitted 28 February, 2023; originally announced February 2023.

    Comments: 19 pages, 7 pages

  7. arXiv:2302.02967  [pdf, other

    physics.med-ph physics.comp-ph physics.ins-det

    TOF MLEM Adaptation for the Total-Body J-PET with a Realistic Analytical System Response Matrix

    Authors: R. Y. Shopa, J. Baran, K. Klimaszewski, W. Krzemień, L. Raczyński, W. Wiślicki, K. Brzeziński, N. Chug, A. Coussat, C. Curceanu, E. Czerwiński, M. Dadgar, K. Dulski, J. Gajewski, A. Gajos, B. C. Hiesmayr, E. Kavya Valsan, G. Korcyl, T. Kozik, D. Kumar, Ł. Kapłon, G. Moskal, S. Niedźwiecki, D. Panek, S. Parzych , et al. (10 additional authors not shown)

    Abstract: We report a study of the original image reconstruction algorithm based on the time-of-flight maximum likelihood expectation maximisation (TOF MLEM), developed for the total-body (TB) Jagiellonian PET (J-PET) scanners. The method is applicable to generic cylindrical or modular multi-layer layouts and is extendable to multi-photon imaging. The system response matrix (SRM) is represented as a set of… ▽ More

    Submitted 8 August, 2024; v1 submitted 6 February, 2023; originally announced February 2023.

    Journal ref: IEEE Transactions on Radiation and Plasma Medical Sciences 7(5) (2023) 509-520

  8. J-PET detection modules based on plastic scintillators for performing studies with positron and positronium beams

    Authors: S. Sharma, J. Baran, R. S. Brusa, R. Caravita, N. Chug, A. Coussat, C. Curceanu, E. Czerwinski, M. Dadgar, K. Dulski, K. Eliyan, A. Gajos, B. C. Hiesmayr, K. Kacprzak, L. Kaplon, K. Klimaszewski, P. Konieczka, G. Korcyl, T. Kozik, W. Krzemien, D. Kumar, S. Mariazzi, S. Niedzwiecki, L. Panasa, S. Parzych , et al. (11 additional authors not shown)

    Abstract: The J-PET detector, which consists of inexpensive plastic scintillators, has demonstrated its potential in the study of fundamental physics. In recent years, a prototype with 192 plastic scintillators arranged in 3 layers has been optimized for the study of positronium decays. This allows performing precision tests of discrete symmetries (C, P, T) in the decays of positronium atoms. Moreover, than… ▽ More

    Submitted 7 January, 2023; originally announced January 2023.

  9. arXiv:2212.02285  [pdf, other

    physics.med-ph physics.ins-det

    Realistic Total-Body J-PET Geometry Optimization -- Monte Carlo Study

    Authors: Jakub Baran, Wojciech Krzemien, Lech Raczyński, Mateusz Bała, Aurelien Coussat, Szymon Parzych, Neha Chug, Eryk Czerwiński, Catalina Oana Curceanu, Meysam Dadgar, Kamil Dulski, Kavya Eliyan, Jan Gajewski, Aleksander Gajos, Beatrix Hiesmayr, Krzysztof Kacprzak, Łukasz Kapłon, Konrad Klimaszewski, Grzegorz Korcyl, Tomasz Kozik, Deepak Kumar, Szymon Niedźwiecki, Dominik Panek, Elena Perez del Rio, Antoni Ruciński , et al. (9 additional authors not shown)

    Abstract: Total-Body PET is one of the most promising medical diagnostics modalities. The high sensitivity provided by Total-Body technology can be advantageous for novel tomography methods like positronium imaging. Several efforts are ongoing to lower the price of the TB-PET systems. Among the alternatives, the Jagiellonian PET (J-PET) technology, based on plastic scintillator strips, offers a low-cost alt… ▽ More

    Submitted 16 February, 2024; v1 submitted 5 December, 2022; originally announced December 2022.

  10. arXiv:2112.08741  [pdf

    physics.med-ph physics.bio-ph

    Positronium imaging with the novel multiphoton PET scanner

    Authors: Paweł Moskal, Kamil Dulski, Neha Chug, Catalina Curceanu, Eryk Czerwiński, Meysam Dadgar, Jan Gajewski, Aleksander Gajos, Grzegorz Grudzień, Beatrix C. Hiesmayr, Krzysztof Kacprzak, Łukasz Kapłon, Hanieh Karimi, Konrad Klimaszewski, Grzegorz Korcyl, Paweł Kowalski, Tomasz Kozik, Nikodem Krawczyk, Wojciech Krzemień, Ewelina Kubicz, Piotr Małczak, Szymon Niedźwiecki, Monika Pawlik-Niedźwiecka, Michał Pędziwiatr, Lech Raczyński , et al. (11 additional authors not shown)

    Abstract: In vivo assessment of cancer and precise location of altered tissues at initial stages of molecular disorders are important diagnostic challenges. Positronium is copiously formed in the free molecular spaces in the patient's body during positron emission tomography (PET). The positronium properties vary according to the size of inter- and intramolecular voids and the concentration of molecules in… ▽ More

    Submitted 16 December, 2021; originally announced December 2021.

    Comments: 10 pages, 5 figures

    Journal ref: Science Advances 7 (2021) eabh4394

  11. arXiv:2107.12750  [pdf, other

    physics.med-ph physics.comp-ph physics.ins-det

    Optimisation of the event-based TOF filtered back-projection for online imaging in total-body J-PET

    Authors: R. Y. Shopa, K. Klimaszewski, P. Kopka, P. Kowalski, W. Krzemień, L. Raczyński, W. Wiślicki, N. Chug, C. Curceanu, E. Czerwiński, M. Dadgar, K. Dulski, A. Gajos, B. C. Hiesmayr, K. Kacprzak, Ł. Kapłon, D. Kisielewska, G. Korcyl, N. Krawczyk, E. Kubicz, Sz. Niedźwiecki, J. Raj, S. Sharma, Shivani, E. L. Stȩpień , et al. (2 additional authors not shown)

    Abstract: We perform a parametric study of the newly developed time-of-flight (TOF) image reconstruction algorithm, proposed for the real-time imaging in total-body Jagiellonian PET (J-PET) scanners. The asymmetric 3D filtering kernel is applied at each most likely position of electron-positron annihilation, estimated from the emissions of back-to-back $γ$-photons. The optimisation of its parameters is stud… ▽ More

    Submitted 27 July, 2021; originally announced July 2021.

  12. arXiv:2107.01356  [pdf, other

    physics.ins-det physics.med-ph

    Simulating NEMA characteristics of the modular total-body J-PET scanner -- an economic total-body PET from plastic scintillators

    Authors: Paweł Moskal, Paweł Kowalski, Roman Shopa, Lech Raczyński, Jakub Baran, Neha Chug, Catalina Curceanu, Eryk Czerwiński, Meysam Dadgar, Kamil Dulski, Aleksander Gajos, Beatrix Hiesmayr, Krzysztof Kacprzak, Łukasz Kapłon, Daria Kisielewska, Konrad Klimaszewski, Przemysław Kopka, Gregorz Korcyl, Nikodem Krawczyk, Wojciech Krzemień, Ewelina Kubicz, Szymon Niedźwiecki, Szymon Parzych, Juhi Raj, Sushil Sharma , et al. (4 additional authors not shown)

    Abstract: The purpose of the presented research is estimation of the performance characteristics of the economic Total-Body Jagiellonian-PET system (TB-J-PET) constructed from plastic scintillators. The characteristics are estimated according to the NEMA NU-2-2018 standards utilizing the GATE package. The simulated detector consists of 24 modules, each built out of 32 plastic scintillator strips (each with… ▽ More

    Submitted 3 July, 2021; originally announced July 2021.

    Comments: 31 pages, 11 figures, 6 tables, submitted to Physics in Medicine and Biology 2021

  13. arXiv:2008.10868  [pdf, other

    physics.ins-det physics.med-ph

    Synchronisation and calibration of the 24-modules J-PET prototype with 300~mm axial field of view

    Authors: P. Moskal, T. Bednarski, Sz. Niedzwiecki, M. Silarski, E. Czerwinski, T. Kozik, J. Chhokar, M. Bała, C. Curceanu, R. Del Grande, M. Dadgar, K. Dulski, A. Gajos, M. Gorgol, N. Gupta-Sharma, B. C. Hiesmayr, B. Jasinska, K. Kacprzak, L. Kaplon, H. Karimi, D. Kisielewska, K. Klimaszewski, G. Korcyl, P. Kowalski, N. Krawczyk , et al. (14 additional authors not shown)

    Abstract: Research conducted in the framework of the J-PET project aims to develop a cost-effective total-body positron emission tomography scanner. As a first step on the way to construct a full-scale J-PET tomograph from long strips of plastic scintillators, a 24-strip prototype was built and tested. The prototype consists of detection modules arranged axially forming a cylindrical diagnostic chamber with… ▽ More

    Submitted 25 August, 2020; originally announced August 2020.

    Comments: Accepted for publication in IEEE Transactions on Instrumentation and Measurement

  14. arXiv:2006.07467  [pdf, other

    physics.ins-det nucl-ex

    The J-PET detector -- a tool for precision studies of ortho-positronium decays

    Authors: K. Dulski, S. D. Bass, J. Chhokar, N. Chug, C. Curceanu, E. Czerwiński, M. Dadgar, J. Gajewski, A. Gajos, M. Gorgol, R. Del Grande, B. C. Hiesmayr, B. Jasińska, K. Kacprzak, Ł. Kapłon, H. Karimi, D. Kisielewska, K. Klimaszewski, P. Kopka, G. Korcyl, P. Kowalski, T. Kozik, N. Krawczyk, W. Krzemień, E. Kubicz , et al. (19 additional authors not shown)

    Abstract: The J-PET tomograph is constructed from plastic scintillator strips arranged axially in concentric cylindrical layers. It enables investigations of positronium decays by measurement of the time, position, polarization and energy deposited by photons in the scintillators, in contrast to studies conducted so far with crystal and semiconductor based detection systems where the key selection of events… ▽ More

    Submitted 25 May, 2021; v1 submitted 9 June, 2020; originally announced June 2020.

    Comments: 12 pages, 7 figures

  15. arXiv:2004.12742  [pdf, other

    physics.ins-det physics.med-ph

    Hit-time and hit-position reconstruction in strips of plastic scintillators using multi-threshold readouts

    Authors: N. G. Sharma, M. Silarski, J. Chhokar, E. Czerwinski, C. Curceanu, K. Dulski, K. Farbaniec, A. Gajos, R. Del Grande, M. Gorgol, B. C. Hiesmayr, B. Jasinska, K. Kacprzak, L. Kaplon, D. Kisielewska, K. Klimaszewski, G. Korcyl, P. Kowalski, N. Krawczyk, W. Krzemien, T. Kozik, E. Kubicz, M. Mohammed, Sz. Niedzwiecki, M. Palka , et al. (10 additional authors not shown)

    Abstract: In this article, a new method for the reconstruction of hit-position and hit-time of photons in long scintillator detectors is investigated. This research is motivated by the recent development of the positron emission tomography scanners based on plastic scintillators. The proposed method constitutes a new way of signal processing in Multi-Voltage-Technique. It is based on the determination of th… ▽ More

    Submitted 27 April, 2020; originally announced April 2020.

  16. arXiv:1911.12059  [pdf, other

    physics.ins-det physics.med-ph

    Estimating relationship between the Time Over Threshold and energy loss by photons in plastic scintillators used in the J-PET scanner

    Authors: S. Sharma, J. Chhokar, C. Curceanu, E. Czerwinski, M. Dadgar, K. Dulski, J. Gajewski, A. Gajos, M. Gorgol, N. Gupta-Sharma, R. Del Grande, B. C. Hiesmayr, B. Jasinska, K. Kacprzak, L. Kaplon, H. Karimi, D. Kisielewska, K. Klimaszewski, G. Korcyl, P. Kowalski, T. Kozik, N. Krawczyk, W. Krzemien, E. Kubicz, M. Mohammed , et al. (14 additional authors not shown)

    Abstract: Time-Over-Threshold (TOT) technique is being used widely due to its implications in developing the multi channel readouts mainly when fast signal processing is required. Using TOT technique as a measure of energy loss instead of charge integration methods significantly reduces the signals readout cost by combining the time and energy information. Therefore, this approach can potentially be used in… ▽ More

    Submitted 27 November, 2019; originally announced November 2019.

  17. arXiv:1911.06841  [pdf, other

    physics.ins-det physics.med-ph

    Performance assessment of the 2$γ$ positronium imaging with the total-body PET scanners

    Authors: P. Moskal, D. Kisielewska, Z. Bura, C. Chhokar, C. Curceanu, E. Czerwiński, M. Dadgar 1, K. Dulski, J. Gajewski, A. Gajos, M. Gorgol, R. Del Grande, B. C. Hiesmayr, B. Jasińska, K. Kacprzak, A. Kamińska, Ł. Kapłon, H. Karimi, G. Korcyl, P. Kowalski, N. Krawczyk, W. Krzemień, T. Kozik, E. Kubicz, P. Małczak , et al. (17 additional authors not shown)

    Abstract: In living organisms the positron-electron annihilation (occurring during the PET imaging) proceeds in about 30% via creation of a metastable ortho-positronium atom. In the tissue, due to the pick-off and conversion processes, over 98% of ortho-positronia annihilate into two 511~keV photons. In this article we assess the feasibility for reconstruction of the mean ortho-positronium lifetime image ba… ▽ More

    Submitted 15 November, 2019; originally announced November 2019.

  18. Simulation studies of annihilation-photon's polarisation via Compton scattering with the J-PET tomograph

    Authors: N. Krawczyk, B. C. Hiesmayr, C. Curceanu, E. Czerwiński, K. Dulski, A. Gajos, M. Gorgol, N. Gupta-Sharma, B. Jasińska, K. Kacprzak, Ł. Kapłon, D. Kisielewska, K. Klimaszewski, G. Korcyl, P. Kowalski, T. Kozik, N. Krawczyk, W. Krzemień, E. Kubicz, M. Mohammed, Sz. Niedźwiecki, M. Pałka, M. Pawlik-Niedźwiecka, L. Raczyński, J. Raj , et al. (10 additional authors not shown)

    Abstract: J-PET is the first positron-emission tomograph (PET) constructed from plastic scintillators. It was optimized for the detection of photons from electron-positron annihilation. Such photons, having an energy of 511 keV, interact with electrons in plastic scintillators predominantly via the Compton effect. Compton scattering is at most probable at an angle orthogonal to the electric field vector of… ▽ More

    Submitted 18 January, 2019; originally announced January 2019.

    Comments: Submitted to Hyperfine Interactions

  19. Feasibility studies of the polarization of photons beyond the optical wavelength regime with the J-PET detector

    Authors: P. Moskal, N. Krawczyk, B. C. Hiesmayr, M. Bała, C. Curceanu, E. Czerwiński, K. Dulski, A. Gajos, M. Gorgol, R. Del Grande, B. Jasińska, K. Kacprzak, L. Kapłon, D. Kisielewska, K. Klimaszewski, G. Korcyl, P. Kowalski, T. Kozik, W. Krzemień, E. Kubicz, M. Mohammed, Sz. Niedźwiecki, M. Pałka, J. Raj, Z. Rudy , et al. (9 additional authors not shown)

    Abstract: J-PET is a detector optimized for registration of photons from the electron-positron annihilation via plastic scintillators where photons interact predominantly via Compton scattering. Registration of both primary and scattered photons enables to determinate the linear polarization of the primary photon on the event by event basis with a certain probability. Here we present quantitative results on… ▽ More

    Submitted 27 September, 2018; originally announced September 2018.

    Comments: 10 pages, 14 figures, submitted to EPJ C

  20. arXiv:1809.05175  [pdf, other

    physics.ins-det nucl-ex

    Commissioning of the J-PET detector in view of the positron annihilation lifetime spectroscopy

    Authors: K. Dulski, C. Curceanu, E. Czerwiński, A. Gajos, M. Gorgol, N. Gupta-Sharma, B. C. Hiesmayr, B. Jasińska, K. Kacprzak Ł. Kapłon, D. Kisielewska, K. Klimaszewski, G. Korcyl, P. Kowalski, N. Krawczyk, W. Krzemień, T. Kozik, E. Kubicz, M. Mohammed, Sz. Niedźwiecki, M. Pałka, M. Pawlik-Niedźwiecka, L. Raczyński, J. Raj, K. Rakoczy, Z. Rudy , et al. (8 additional authors not shown)

    Abstract: The Jagiellonian Positron Emission Tomograph (J-PET) is the first PET device built from plastic scintillators. It is a multi-purpose detector designed for medical imaging and for studies of properties of positronium atoms in porous matter and in living organisms. In this article we report on the commissioning of the J-PET detector in view of studies of positronium decays. We present results of ana… ▽ More

    Submitted 12 September, 2018; originally announced September 2018.

    Comments: 5 pages, 2 figures

  21. arXiv:1809.00847  [pdf, other

    physics.ins-det hep-ex

    A feasibility study of the time reversal violation test based on polarization of annihilation photons from the decay of ortho-Positronium with the J-PET detector

    Authors: J. Raj, A. Gajos, C. Curceanu, E. Czerwinski, K. Dulski, M. Gorgol, N. Gupta-Sharma, B. C. Hiesmayr, B. Jasińska, K. Kacprzak, L. Kaplon, D. Kisielewska, K. Klimaszewski, G. Korcyl, P. Kowalski, T. Kozik, N. Krawczyk, W. Krzemien, E. Kubicz, M. Mohammed, Sz. Niedzwiecki, M. Palka, M. Pawlik-Niedzwiecka, L. Raczynski, K. Rakoczy , et al. (9 additional authors not shown)

    Abstract: The Jagiellonian Positron Emission Tomograph (J-PET) is a novel de- vice being developed at Jagiellonian University in Krakow, Poland based on or- ganic scintillators. J-PET is an axially symmetric and high acceptance scanner that can be used as a multi-purpose detector system. It is well suited to pur- sue tests of discrete symmetries in decays of positronium in addition to medical imaging. J-PET… ▽ More

    Submitted 4 September, 2018; originally announced September 2018.

  22. Estimating the NEMA characteristics of the J-PET tomograph using the GATE package

    Authors: Paweł Kowalski, Wojciech Wiślicki, Roman Shopa, Lech Raczyński, Konrad Klimaszewski, Catalina Curceanu, Eryk Czerwiński, Kamil Dulski, Aleksander Gajos, Marek Gorgol, Neha Gupta-Sharma, Beatrix Hiesmayr, Bożena Jasińska, Łukasz Kapłon, Daria Kamińska, Grzegorz Korcyl, Tomasz Kozik, Wojciech Krzemień, Ewelina Kubicz, Muhsin Mohammed, Szymon Niedzwiecki, Marek Pałka, Monika Pawlik-Niedźwiecka, Juhi Raj, Kamil Rakoczy , et al. (8 additional authors not shown)

    Abstract: The novel whole-body PET system based on plastic scintillators is developed by the {J-PET} Collaboration. It consists of plastic scintillator strips arranged axially in the form of a cylinder, allowing the cost-effective construction of the total-body PET. In order to determine properties of the scanner prototype and optimize its geometry, advanced computer simulations using the GATE software were… ▽ More

    Submitted 1 August, 2018; originally announced August 2018.

    Journal ref: Kowalski, Paweł, et al. "Estimation of the NEMA characteristics of the J-PET tomograph using the GATE package." Physics in medicine and biology (2018)

  23. arXiv:1805.11696  [pdf, other

    physics.ins-det physics.med-ph

    Feasibility study of the positronium imaging with the J-PET tomograph

    Authors: P. Moskal, D. Kisielewska, C. Curceanu, E. Czerwiński, K. Dulski, A. Gajos, M. Gorgol, B. Hiesmayr, B. Jasińska, K. Kacprzak, Ł. Kapłon, G. Korcyl, P. Kowalski, W. Krzemień, T. Kozik, E. Kubicz, M. Mohammed, Sz. Niedźwiecki, M. Pałka, M. Pawlik-Niedźwiecka, L. Raczyński, J. Raj, S. Sharma, Shivani, R. Y. Shopa , et al. (5 additional authors not shown)

    Abstract: A detection system of the conventional PET tomograph is set-up to record data from e+ e- annihilation into two photons with energy of 511 keV, and it gives information on the density distribution of a radiopharmaceutical in the body of the object. In this paper we explore the possibility of performing the three gamma photons imaging based on ortho-positronium annihilation, as well as the possibili… ▽ More

    Submitted 15 January, 2019; v1 submitted 29 May, 2018; originally announced May 2018.

    Comments: accepted in PMB (http://iopscience.iop.org/article/10.1088/1361-6560/aafe20)

  24. arXiv:1804.07148  [pdf, other

    physics.ins-det hep-ex

    Feasibility study of the time reversal symmetry tests in decays of metastable positronium atoms with the J-PET detector

    Authors: A. Gajos, C. Curceanu, E. Czerwiński, K. Dulski, M. Gorgol, N. Gupta-Sharma, B. C. Hiesmayr, B. Jasińska, K. Kacprzak, Ł. Kapłon, D. Kisielewska, G. Korcyl, P. Kowalski, T. Kozik, W. Krzemień, E. Kubicz, M. Mohammed, Sz. Niedźwiecki, M. Pałka, M. Pawlik-Niedźwiecka, L. Raczyński, J. Raj, Z. Rudy, S. Sharma, Shivani , et al. (7 additional authors not shown)

    Abstract: This article reports on the feasibility of testing of the symmetry under reversal in time in a purely leptonic system constituted by positronium atoms using the J-PET detector. The present state of T symmetry tests is discussed with an emphasis on the scarcely explored sector of leptonic systems. Two possible strategies of searching for manifestations of T violation in non-vanishing angular correl… ▽ More

    Submitted 19 April, 2018; originally announced April 2018.

    Comments: 15 pages, 9 figures. Submitted to Advances in High Energy Physics

  25. arXiv:1710.11369  [pdf, other

    physics.ins-det hep-ex physics.med-ph

    J-PET: a new technology for the whole-body PET imaging

    Authors: S. Niedźwiecki, P. Białas, C. Curceanu, E. Czerwiński, K. Dulski, A. Gajos, B. Głowacz, M. Gorgol, B. C. Hiesmayr, B. Jasińska, Ł. Kapłon, D. Kisielewska-Kamińska, G. Korcyl, P. Kowalski, T. Kozik, N. Krawczyk, W. Krzemień, E. Kubicz, M. Mohammed, M. Pawlik-Niedźwiecka, M. Pałka, L. Raczyński, Z. Rudy, N. G. Sharma, S. Sharma , et al. (8 additional authors not shown)

    Abstract: The Jagiellonian Positron Emission Tomograph (J-PET) is the first PET built from plastic scintillators. J-PET prototype consists of 192 detection modules arranged axially in three layers forming a cylindrical diagnostic chamber with the inner diameter of 85 cm and the axial field-of-view of 50 cm. An axial arrangement of long strips of plastic scintillators, their small light attenuation, superior… ▽ More

    Submitted 31 October, 2017; originally announced October 2017.

    Comments: Presented at the 2nd Jagiellonian Symposium on Fundamental and Applied Subatomic Physics, Kraków, Poland, June 4-9, 2017. To be published in Acta Phys. Pol. B

    Journal ref: Acta Physica Polonica B, Vol. 48, pp. 1567, 2017

  26. arXiv:1602.07528  [pdf, other

    physics.ins-det nucl-ex

    Trilateration-based reconstruction of ortho-positronium decays into three photons with the J-PET detector

    Authors: A. Gajos, D. Kamińska, E. Czerwiński, D. Alfs, T. Bednarski, P. Białas, B. Głowacz, M. Gorgol, B. Jasińska, Ł. Kapłon, G. Korcyl, P. Kowalski, T. Kozik, W. Krzemień, E. Kubicz, M. Mohammed, Sz. Niedźwiecki, M. Pałka, M. Pawlik-Niedźwiecka, L. Raczyński, Z. Rudy, O. Rundel, N. G. Sharma, M. Silarski, A. Słomski , et al. (6 additional authors not shown)

    Abstract: This work reports on a new reconstruction algorithm allowing to reconstruct the decays of ortho-positronium atoms into three photons using the places and times of photons recorded in the detector. The method is based on trilateration and allows for a simultaneous reconstruction of both location and time of the decay. Results of resolution tests of the new reconstruction in the J-PET detector based… ▽ More

    Submitted 24 February, 2016; originally announced February 2016.

    Comments: 18 pages, 5 figures. Accepted for publication in Nuclear Instrumentation and Methods in Physics Research A

  27. arXiv:1602.05376  [pdf

    nucl-ex physics.ins-det

    Determination of the 3γfraction from positron annihilation in mesoporous materials for symmetry violation experiment with J-PET scanner

    Authors: B. Jasińska, M. Gorgol, M. Wiertel, R. Zaleski, D. Alfs, T. Bednarski, P. Białas, E. Czerwiński, K. Dulski, A. Gajos, B. Głowacz, D. Kamińska, Ł. Kapłon, G. Korcyl, P. Kowalski, T. Kozik, W. Krzemień, E. Kubicz, M. Mohammed, Sz. Niedźwiecki, M. Pałka, L. Raczyński, Z. Rudy, O. Rundel, N. G. Sharma , et al. (8 additional authors not shown)

    Abstract: Various mesoporous materials were investigated to choose the best material for experiments requiring high yield of long-lived positronium. We found that the fraction of 3γannihilation determined using γ-ray energy spectra and positron annihilation lifetime spectra (PAL) changed from 20% to 25%. The 3gamma fraction and o-Ps formation probability in the polymer XAD-4 is found to be the largest. Elem… ▽ More

    Submitted 17 February, 2016; originally announced February 2016.

    Comments: 12 pages, 2 figures

  28. Sampling FEE and Trigger-less DAQ for the J-PET Scanner

    Authors: G. Korcyl, D. Alfs, T. Bednarski, P. Białas, E. Czerwiński, K. Dulski, A. Gajos, B. Głowacz, B. Jasińska, D. Kamińska, Ł. Kapłon, P. Kowalski, T. Kozik, W. Krzemień, E. Kubicz, M. Mohammed, Sz. Niedźwiecki, M. Pałka, M. Pawlik-Niedźwiecka, L. Raczyński, Z. Rudy, O. Rundel, N. G. Sharma, M. Silarski, A. Słomski , et al. (7 additional authors not shown)

    Abstract: In this paper, we present a complete Data Acquisition System (DAQ) together with the readout mechanisms for the J-PET tomography scanner. In general detector readout chain is constructed out of Front-End Electronics (FEE), measurement devices like Time-to-Digital or Analog-to-Digital Converters (TDCs or ADCs), data collectors and storage. We have developed a system capable for maintaining continuo… ▽ More

    Submitted 16 February, 2016; originally announced February 2016.

    Comments: 6 pages, 1 figure

  29. arXiv:1602.02058  [pdf, other

    physics.ins-det physics.med-ph

    Time resolution of the plastic scintillator strips with matrix photomultiplier readout for J-PET tomograph

    Authors: P. Moskal, O. Rundel, D. Alfs, T. Bednarski, P. Białas, E. Czerwiński, A. Gajos, K. Giergiel, M. Gorgol, B. Jasińska, D. Kamińska, Ł. Kapłon, G. Korcyl, P. Kowalski, T. Kozik, W. Krzemień, E. Kubicz, Sz. Niedźwiecki, M. Pałka, L. Raczyński, Z. Rudy, N. G. Sharma, A. Słomski, M. Silarski, A. Strzelecki , et al. (5 additional authors not shown)

    Abstract: Recent tests of a single module of the Jagiellonian Positron Emission Tomography system (J-PET) consisting of 30 cm long plastic scintillator strips have proven its applicability for the detection of annihilation quanta (0.511 MeV) with a coincidence resolving time (CRT) of 0.266 ns. The achieved resolution is almost by a factor of two better with respect to the current TOF-PET detectors and it ca… ▽ More

    Submitted 19 March, 2016; v1 submitted 5 February, 2016; originally announced February 2016.

    Comments: To be published in Phys. Med. Biol. (26 pages, 17 figures)

    Journal ref: Phys. Med. Biol. 61 (2016) 2025

  30. arXiv:1509.01114  [pdf, other

    physics.ins-det hep-ex

    Searches for discrete symmetries violation in ortho-positronium decay using the J-PET detector

    Authors: D. Kamińska, T. Bednarski, P. Białas, E. Czerwiński, A. Gajos, M. Gorgol, B. Jasińska, Ł. Kapłon, G. Korcyl, P. Kowalski, T. Kozik, W. Krzemień, E. Kubicz, Sz. Niedźwiecki, M. Pałka, L. Raczyński, Z. Rudy, O. Rundel, N. G. Sharma, M. Silarski, A. Słomski, A. Strzelecki, A. Wieczorek, W. Wiślicki, M. Zieliński , et al. (2 additional authors not shown)

    Abstract: In this paper we present prospects for using the J-PET detector to search for discrete symmetries violations in a purely leptonic system of the positronium atom. We discuss tests of CP and CPT symmetries by means of ortho-positronium decays into three photons. No zero expectation values for chosen correlations between ortho-positronium spin and momentum vectors of photons would imply the existence… ▽ More

    Submitted 3 September, 2015; originally announced September 2015.

    Comments: in Nukleonika 2015

    Journal ref: Nukleonika 60(4) (2015) 729-732

  31. arXiv:1509.00411  [pdf, other

    q-bio.OT physics.ins-det

    Studies of unicellular micro-organisms Saccharomyces cerevisiae by means of Positron Annihilation Lifetime Spectroscopy

    Authors: E. Kubicz, B. Jasińska, B. Zgardzińska, T. Bednarski, P. Białas, E. Czerwiński, A. Gajos, M. Gorgol, D. Kamińska, Ł. Kapłon, A. Kochanowski, G. Korcyl, P. Kowalski, T. Kozik, W. Krzemień, S. Niedźwiecki, M. Pałka, L. Raczyński, Z. Rajfur, Z. Rudy, O. Rundel, N. G. Sharma, M. Silarski, A. Słomski, A. Strzelecki , et al. (4 additional authors not shown)

    Abstract: Results of Positron Annihilation Lifetime Spectroscopy (PALS) and microscopic studies on simple microorganisms: brewing yeasts are presented. Lifetime of ortho - positronium (o-Ps) were found to change from 2.4 to 2.9 ns (longer lived component) for lyophilised and aqueous yeasts, respectively. Also hygroscopicity of yeasts in time was examined, allowing to check how water - the main component of… ▽ More

    Submitted 30 August, 2015; originally announced September 2015.

    Comments: Nukleonika (2015)

    Journal ref: Nukleonika 60(4) (2015) 749-753

  32. arXiv:1508.07463  [pdf

    physics.ins-det nucl-ex

    Reconstruction of hit-time and hit-position of annihilation quanta in the J-PET detector using the Mahalanobis distance

    Authors: N. G. Sharma, M. Silarski, T. Bednarski, P. Białas, E. Czerwiński, A. Gajos, M. Gorgol, B. Jasińska, D. Kamińska, Ł. Kapłon, G. Korcyl, P. Kowalski, T. Kozik, W. Krzemień, E. Kubicz, Sz. Niedźwiecki, M. Pałka, L. Raczyński, Z. Rudy, O. Rundel, A. Słomski, A. Strzelecki, A. Wieczorek, W. Wiślicki, M. Zieliński , et al. (2 additional authors not shown)

    Abstract: The J-PET detector being developed at Jagiellonian University, is a Positron Emission Tomograph composed of the long strips of polymer scintillators. At the same time it is a detector system which will be used for studies of the decays of positronium atoms. The shape of photomultiplier signals depends on the hit-time and hit-position of the gamma quantum. In order to take advantage of this fact a… ▽ More

    Submitted 29 August, 2015; originally announced August 2015.

    Comments: 12 pages, 4 figures

    Journal ref: Nukleonika 60(4) (2015) 765-769

  33. arXiv:1508.06820  [pdf, other

    physics.ins-det nucl-ex

    PALS investigations of free volumes thermal expansion of J-PET plastic scintillator synthesized in polystyrene matrix

    Authors: A. Wieczorek, B. Zgardzińska, B. Jasińska, M. Gorgol, T. Bednarski, P. Białas, E. Czerwiński, A. Gajos, D. Kamińska, Ł. Kapłon, A. Kochanowski, G. Korcyl, P. Kowalski, T. Kozik, W. Krzemień, E. Kubicz, S. Niedźwiecki, M. Pałka, L. Raczyński, Z. Rudy, O. Rundel, N. G. Sharma, M. Silarski, A. Słomski, A. Strzelecki , et al. (3 additional authors not shown)

    Abstract: The polystyrene dopped with 2,5-diphenyloxazole as a primary fluor and 2-(4-styrylphenyl)benzoxazole as a wavelength shifter, prepared as a plastic scintillator was investigated using positronium probe in wide range of temperatures from 123 to 423 K. Three structural transitions at 260 K, 283 K and 370 K were found in the material. In the o-Ps intensity dependence on temperature, the significant h… ▽ More

    Submitted 27 August, 2015; originally announced August 2015.

    Comments: in Nukleonika 2015

    Journal ref: Nukleonika 60(4) (2015) 777-781

  34. arXiv:1508.02751  [pdf, ps, other

    physics.ins-det physics.comp-ph

    Processing optimization with parallel computing for the J-PET tomography scanner

    Authors: W. Krzemień, M. Bała, T. Bednarski, P. Białas, E. Czerwiński, A. Gajos, M. Gorgol, B. Jasińska, D. Kamińska, Ł. Kapłon, G. Korcyl, P. Kowalski, T. Kozik, E. Kubicz, Sz. Niedźwiecki, M. Pałka, L. Raczyński, Z. Rudy, O. Rundel, N. G. Sharma, M. Silarski, A. Słomski, K. Stola, A. Strzelecki, D. Trybek , et al. (5 additional authors not shown)

    Abstract: The Jagiellonian-PET (J-PET) collaboration is developing a prototype TOF-PET detector based on long polymer scintillators. This novel approach exploits the excellent time properties of the plastic scintillators, which permit very precise time measurements. The very fast, FPGA-based front-end electronics and the data acquisition system, as well as, low- and high-level reconstruction algorithms were… ▽ More

    Submitted 11 August, 2015; originally announced August 2015.

    Comments: 8 pages

    Journal ref: NUKLEONIKA 2015 60 (4) 745

  35. arXiv:1507.03799  [pdf, other

    physics.ins-det hep-ex

    Application of the Compress Sensing Theory for Improvement of the TOF Resolution in a Novel J-PET Instrument

    Authors: L. Raczynski, P. Moskal, P. Kowalski, W. Wislicki, T. Bednarski, P. Bialas, E. Czerwinski, A. Gajos, L. Kaplon, A. Kochanowski, G. Korcyl, J. Kowal, T. Kozik, W. Krzemien, E. Kubicz, Sz. Niedzwiecki, M. Palka, Z. Rudy, P. Salabura, N. G. Sharma, M. Silarski, A. Slomski, J. Smyrski, A. Strzelecki, A. Wieczorek , et al. (2 additional authors not shown)

    Abstract: Nowadays, in Positron Emission Tomography (PET) systems, a Time of Flight information is used to improve the image reconstruction process. In Time of Flight PET (TOF-PET), fast detectors are able to measure the difference in the arrival time of the two gamma rays, with the precision enabling to shorten significantly a range along the line-of-response (LOR) where the annihilation occurred. In the n… ▽ More

    Submitted 8 August, 2015; v1 submitted 14 July, 2015; originally announced July 2015.

    Journal ref: Nukleonika 61, (2016) 35-39

  36. arXiv:1504.06889  [pdf

    physics.med-ph physics.ins-det

    3D PET image reconstruction based on Maximum Likelihood Estimation Method (MLEM) algorithm

    Authors: Artur Słomski, Zbigniew Rudy, Tomasz Bednarski, Piotr Białas, Eryk Czerwiński, Łukasz Kapłon, Andrzej Kochanowski, Grzegorz Korcyl, Jakub Kowal, Paweł Kowalski, Tomasz Kozik, Wojciech Krzemień, Marcin Molenda, Paweł Moskal, Szymon Niedźwiecki, Marek Pałka, Monika Pawlik, Lech Raczyński, Piotr Salabura, Neha Gupta-Sharma, Michał Silarski, Jerzy Smyrski, Adam Strzelecki, Wojciech Wiślicki, Marcin Zieliński , et al. (1 additional authors not shown)

    Abstract: Positron emission tomographs (PET) do not measure an image directly. Instead, they measure at the boundary of the field-of-view (FOV) of PET tomograph a sinogram that consists of measurements of the sums of all the counts along the lines connecting two detectors. As there is a multitude of detectors build-in typical PET tomograph structure, there are many possible detector pairs that pertain to th… ▽ More

    Submitted 26 April, 2015; originally announced April 2015.

    Comments: 10 pages, 7 figures

    Journal ref: Bio-Algorithms and Med-Systems 10(1), 1-7 (2014)

  37. arXiv:1504.06886  [pdf

    physics.ins-det cond-mat.mtrl-sci physics.med-ph

    Plastic scintillators for positron emission tomography obtained by the bulk polymerization method

    Authors: Łukasz Kapłon, Andrzej Kochanowski, Marcin Molenda, Paweł Moskal, Anna Wieczorek, Tomasz Bednarski, Piotr Białas, Eryk Czerwiński, Grzegorz Korcyl, Jakub Kowal, Paweł Kowalski, Tomasz Kozik, Wojciech Krzemień, Szymon Niedźwiecki, Marek Pałka, Monika Pawlik, Lech Raczyński, Zbigniew Rudy, Piotr Salabura, Neha Gupta-Sharma, Michał Silarski, Artur Słomski, Jerzy Smyrski, Adam Strzelecki, Wojciech Wiślicki , et al. (2 additional authors not shown)

    Abstract: This paper describes three methods regarding the production of plastic scintillators. One method appears to be suitable for the manufacturing of plastic scintillator, revealing properties which fulfill the requirements of novel positron emission tomography scanners based on plastic scintillators. The key parameters of the manufacturing process are determined and discussed.

    Submitted 26 April, 2015; originally announced April 2015.

    Comments: 7 pages, 4 figures

    Journal ref: Bio-Algorithms and Med-Systems 10(1), 27-31 (2014)

  38. Compressive Sensing of Signals Generated in Plastic Scintillators in a Novel J-PET Instrument

    Authors: L. Raczynski, P. Moskal, P. Kowalski, W. Wislicki, T. Bednarski, P. Bialas, E. Czerwinski, A. Gajos, L. Kaplon, A. Kochanowski, G. Korcyl, J. Kowal, T. Kozik, W. Krzemien, E. Kubicz, Sz. Niedzwiecki, M. Palka, Z. Rudy, O. Rundel, P. Salabura, N. G. Sharma, M. Silarski, A. S lomski, J. Smyrski, A. Strzelecki , et al. (3 additional authors not shown)

    Abstract: The J-PET scanner, which allows for single bed imaging of the whole human body, is currently under development at the Jagiellonian University. The dis- cussed detector offers improvement of the Time of Flight (TOF) resolution due to the use of fast plastic scintillators and dedicated electronics allowing for sam- pling in the voltage domain of signals with durations of few nanoseconds. In this pap… ▽ More

    Submitted 4 April, 2015; v1 submitted 17 March, 2015; originally announced March 2015.

  39. arXiv:1503.00465  [pdf, ps, other

    physics.ins-det physics.med-ph

    Analysis framework for the J-PET scanner

    Authors: W. Krzemień, A. Gajos, A. Gruntowski, K. Stola, D. Trybek, T. Bednarski, P. Białas, E. Czerwiński, D. Kamińska, L. Kapłon, A. Kochanowski, G. Korcyl, J. Kowal, P. Kowalski, T. Kozik, E. Kubicz, P. Moskal, Sz. Niedźwiecki, M. Pałka, L. Raczyński, Z. Rudy, P. Salabura, N. G. Sharma, M. Silarski, A. Słomski , et al. (6 additional authors not shown)

    Abstract: J-PET analysis framework is a flexible, lightweight, ROOT-based software package which provides the tools to develop reconstruction and calibration procedures for PET tomography. In this article we present the implementation of the full data-processing chain in the J-PET framework which is used for the data analysis of the J-PET tomography scanner. The Framework incorporates automated handling of… ▽ More

    Submitted 5 July, 2015; v1 submitted 2 March, 2015; originally announced March 2015.

    Comments: 6 pages, 1 figure

    Journal ref: Acta Phys. Pol. A 127 (2015) 1491-1494

  40. arXiv:1502.07886  [pdf, other

    physics.ins-det nucl-ex

    Hit time and hit position reconstruction in the J-PET detector based on a library of averaged model signals

    Authors: P. Moskal, N. G. Sharma, M. Silarski, T. Bednarski, P. Białas, J. Bułka, E. Czerwiński, A. Gajos, D. Kamińska, L. Kapłon, A. Kochanowski, G. Korcyl, J. Kowal, P. Kowalski, T. Kozik, W. Krzemień, E. Kubicz, Sz. Niedźwiecki, M. Pałka, L. Raczyński, Z. Rudy, O. Rundel, P. Salabura, A. Słomski, J. Smyrski , et al. (6 additional authors not shown)

    Abstract: In this article we present a novel method of hit time and hit position reconstruction in long scintillator detectors. We take advantage of the fact that for this kind of detectors amplitude and shape of registered signals depends strongly on the position where particle hit the detector. The reconstruction is based on determination of the degree of similarity between measured and averaged signals s… ▽ More

    Submitted 6 August, 2015; v1 submitted 27 February, 2015; originally announced February 2015.

    Journal ref: Acta Phys. Polon. A 127 (2015) 1495-1499

  41. arXiv:1502.07478  [pdf, other

    physics.ins-det nucl-ex

    GPU accelerated image reconstruction in a two-strip J-PET tomograph

    Authors: P. Białas, J. Kowal, A. Strzelecki, T. Bednarski, E. Czerwiński, A. Gajos, D. Kamińska, Ł. Kapłon, A. Kochanowski, G. Korcyl, P. Kowalski, T. Kozik, W. Krzemień, E. Kubicz, P. Moskal, Sz. Niedźwiecki, M. Pałka, L. Raczyński, Z. Rudy, O. Rundel, P. Salabura, N. G. Sharma, M. Silarski, A. Słomski, J. Smyrski , et al. (4 additional authors not shown)

    Abstract: We present a fast GPU implementation of the image reconstruction routine, for a novel two strip PET detector that relies solely on the time of flight measurements.

    Submitted 6 August, 2015; v1 submitted 26 February, 2015; originally announced February 2015.

    Journal ref: Acta Phys. Polon. A 127 (2015) 1500-1504

  42. Multiple scattering and accidental coincidences in the J-PET detector simulated using GATE package

    Authors: P. Kowalski, P. Moskal, W. Wiślicki, L. Raczyński, T. Bednarski, P. Białas, J. Bułka, E. Czerwiński, A. Gajos, A. Gruntowski, D. Kamińska, Ł. Kapłon, A. Kochanowski, G. Korcyl, J. Kowal, T. Kozik, W. Krzemień, E. Kubicz, Sz. Niedźwiecki, M. Pałka, Z. Rudy, P. Salabura, N. G. Sharma, M. Silarski, A. Słomski , et al. (6 additional authors not shown)

    Abstract: Novel Positron Emission Tomography system, based on plastic scintillators, is developed by the J-PET collaboration. In order to optimize geometrical configuration of built device, advanced computer simulations are performed. Detailed study is presented of background given by accidental coincidences and multiple scattering of gamma quanta.

    Submitted 2 April, 2015; v1 submitted 16 February, 2015; originally announced February 2015.

    Comments: 18 pages, 16 figures

    Journal ref: Acta Phys. Pol A127 (2015) 1505-1512

  43. arXiv:1502.02901  [pdf, other

    physics.ins-det nucl-ex

    A pilot study of the novel J-PET plastic scintillator with 2-(4-styrylphenyl)benzoxazole as a wavelength shifter

    Authors: A. Wieczorek, P. Moskal, Sz. Niedźwiecki, T. Bednarski, P. Białas, E. Czerwiński, A. Danel, A. Gajos, A. Gruntowski, D. Kamińska, Ł. Kapłon, A. Kochanowski, G. Korcyl, J. Kowal, P. Kowalski, T. Kozik, W. Krzemień, E. Kubicz, M. Molenda, M. Pałka, L. Raczyński, Z. Rudy, O. Rundel, P. Salabura, N. G. Sharma , et al. (8 additional authors not shown)

    Abstract: For the first time a molecule of 2-(4-styrylphenyl)benzoxazole containing benzoxazole and stilbene groups is applied as a scintillator dopant acting as a wavelength shifter. In this article a light yield of the plastic scintillator, prepared from styrene doped with 2 wt% of 2,5-diphenylbenzoxazole and 0.03 wt% of 2-(4-styrylphenyl)benzoxazole, is determined to be as large as 60% $\pm$ 2% of the an… ▽ More

    Submitted 4 July, 2015; v1 submitted 10 February, 2015; originally announced February 2015.

    Journal ref: Acta Phys. Pol A127 (2015) 1487-1490

  44. arXiv:1412.6963  [pdf, other

    physics.ins-det nucl-ex

    A novel method for the line-of-response and time-of-flight reconstruction in TOF-PET detectors based on a library of synchronized model signals

    Authors: P. Moskal, N. Zoń, T. Bednarski, P. Białas, E. Czerwiński, A. Gajos, D. Kamińska, Ł. Kapłon, A. Kochanowski, G. Korcyl, J. Kowal, P. Kowalski, T. Kozik, W. Krzemień, E. Kubicz, Sz. Niedźwiecki, M. Pałka, L. Raczyński, Z. Rudy, O. Rundel, P. Salabura, N. G. Sharma, M. Silarski, A. Słomski, J. Smyrski , et al. (4 additional authors not shown)

    Abstract: A novel method of hit time and hit position reconstruction in scintillator detectors is described. The method is based on comparison of detector signals with results stored in a library of synchronized model signals registered for a set of well-defined positions of scintillation points. The hit position is reconstructed as the one corresponding to the signal from the library which is most similar… ▽ More

    Submitted 10 February, 2015; v1 submitted 22 December, 2014; originally announced December 2014.

    Journal ref: Nuclear Inst. and Methods in Physics Research A 775 (2015), 54-62

  45. arXiv:1407.8293  [pdf, other

    physics.ins-det hep-ex

    Novel method for hit-position reconstruction using voltage signals in plastic scintillators and its application to Positron Emission Tomography

    Authors: L. Raczynski, P. Moskal, P. Kowalski, W. Wislicki, T. Bednarski, P. Bialas, E. Czerwinski, L . Kaplon, A. Kochanowski, G. Korcyl, J. Kowal, T. Kozik, W. Krzemien, E. Kubicz, M. Molenda, I. Moskal, Sz. Niedzwiecki, M. Palka, M. Pawlik-Niedzwiecka, Z. Rudy, P. Salabura, N. G. Sharma, M. Silarski, A. Slomski, J. Smyrski , et al. (4 additional authors not shown)

    Abstract: Currently inorganic scintillator detectors are used in all commercial Time of Flight Positron Emission Tomograph (TOF-PET) devices. The J-PET collaboration investigates a possibility of construction of a PET scanner from plastic scintillators which would allow for single bed imaging of the whole human body. This paper describes a novel method of hit-position reconstruction based on sampled signals… ▽ More

    Submitted 31 July, 2014; originally announced July 2014.

  46. arXiv:1407.7395  [pdf, ps, other

    physics.ins-det hep-ex nucl-ex physics.med-ph

    Test of a single module of the J-PET scanner based on plastic scintillators

    Authors: P. Moskal, Sz. Niedźwiecki, T. Bednarski, E. Czerwiński, Ł. Kapłon, E. Kubicz, I. Moskal, M. Pawlik-Niedźwiecka, N. G. Sharma, M. Silarski, M. Zieliński, N. Zoń, P. Białas, A. Gajos, A. Kochanowski, G. Korcyl, J. Kowal, P. Kowalski, T. Kozik, W. Krzemień, M. Molenda, M. Pałka, L. Raczyński, Z. Rudy, P. Salabura , et al. (5 additional authors not shown)

    Abstract: Time of Flight Positron Emission Tomography scanner based on plastic scintillators is being developed at the Jagiellonian University by the J-PET collaboration. The main challenge of the conducted research lies in the elaboration of a method allowing application of plastic scintillators for the detection of low energy gamma quanta. In this article we report on tests of a single detection module bu… ▽ More

    Submitted 29 August, 2014; v1 submitted 28 July, 2014; originally announced July 2014.

    Comments: 12 pages, 6 figures; Updated with editorial corrections related to publication in NIM A

    Journal ref: Nuclear Inst. and Methods in Physics Research A 764 (2014), pp. 317-321

  47. arXiv:1402.6840  [pdf

    physics.ins-det

    Determination of the map of efficiency of the J-PET detector with the GATE package

    Authors: P. Kowalski, L. Raczyński, T. Bednarski, P. Białas, E. Czerwiński, K. Giergiel, Ł. Kapłon, A. Kochanowski, G. Korcyl, J. Kowal, T. Kozik, W. Krzemień, M. Molenda, I. Moskal, P. Moskal, Sz. Niedźwiecki, M. Pałka, M. Pawlik-Niedźwiecka, Z. Rudy, P. Salabura, N. G. Sharma, M. Silarski, A. Słomski, J. Smyrski, A. Strzelecki , et al. (5 additional authors not shown)

    Abstract: A novel PET detector consisting of strips of polymer scintillators is being developed by the J-PET Collaboration. The map of efficiency and the map of geometrical acceptance of the 2-strip J-PET scanner are presented. Map of efficiency was determined using the Monte Carlo simulation software GATE based on GEANT4. Both maps were compared using method based on the chi2 test.

    Submitted 27 February, 2014; originally announced February 2014.

    Comments: 14 pages, 9 figures, proceeding from conference Symposium on Positron Emission Tomography: http://koza.if.uj.edu.pl/pet-symposium-2013/

    Journal ref: Bio-Algorithms and Med-Systems 10(2), 85-90 (2014)

  48. arXiv:1402.4116  [pdf

    physics.ins-det

    Database and data structure for the novel TOF-PET detector developed for J-PET project

    Authors: E. Czerwiński, M. Zieliński, T. Bednarski, P. Białas, Ł. Kapłon, A. Kochanowski, G. Korcyl, J. Kowal, P. Kowalski, T. Kozik, W. Krzemień, E. Kubicz, M. Molenda, P. Moskal, Sz. Niedźwiecki, M. Pałka, M. Pawlik, L. Raczyński, Z. Rudy, P. Salabura, N. G. Sharma, M. Silarski, A. Słomski, J. Smyrski, A. Strzelecki , et al. (3 additional authors not shown)

    Abstract: The complexity of the hardware and the amount of data collected during the PET imaging process require application of modern methods of efficient data organization and processing. In this article we will discuss the data structures and the flow of collected data from the novel TOF-PET medical scanner which is being developed at the Jagiellonian University. The developed data format reflects: regis… ▽ More

    Submitted 17 February, 2014; originally announced February 2014.

    Comments: 6 p, 3 figs, based on talk given at Symposium on Positron Emission Tomography, Sept. 19-22, 2013, Jagiellonian University, Kraków PL, submitted to Bio-Algorithms and Med-Systems

    Journal ref: Bio-Algorithms and Med-Systems 10(2), 79-83 (2014)

  49. arXiv:1401.6929  [pdf

    physics.comp-ph cs.CV cs.DC physics.ins-det physics.med-ph

    Computing support for advanced medical data analysis and imaging

    Authors: W. Wiślicki, T. Bednarski, P. Białas, E. Czerwiński, Ł. Kapłon, A. Kochanowski, G. Korcyl, J. Kowal, P. Kowalski, T. Kozik, W. Krzemień, M. Molenda, P. Moskal, S. Niedźwiecki, M. Pałka, M. Pawlik, L. Raczyński, Z. Rudy, P. Salabura, N. G. Sharma, M. Silarski, A. Słomski, J. Smyrski, A. Strzelecki, A. Wieczorek , et al. (2 additional authors not shown)

    Abstract: We discuss computing issues for data analysis and image reconstruction of PET-TOF medical scanner or other medical scanning devices producing large volumes of data. Service architecture based on the grid and cloud concepts for distributed processing is proposed and critically discussed.

    Submitted 27 January, 2014; originally announced January 2014.

    Comments: 9 p, 3 figs, based on talk given at Symposium on Positron Emission Tomography, Sept. 19-22, 2013, Jagiellonian University, Kraków, Pl

    Journal ref: Bio-Algorithms and Med-Systems 10(2014)52

  50. arXiv:1312.2744  [pdf

    physics.ins-det nucl-ex physics.med-ph

    Calibration of photomultipliers gain used in the J-PET detector

    Authors: T. Bednarski, E. Czerwiński, P. Moskal, P. Białas, K. Giergiel, Ł. Kapłon, A. Kochanowski, G. Korcyl, J. Kowal, P. Kowalski, T. Kozik, W. Krzemień, M. Molenda, I. Moskal, Sz. Niedźwiecki, M. Pałka, M. Pawlik, L. Raczyński, Z. Rudy, P. Salabura, N. G. Sharma, M. Silarski, A. Słomski, J. Smyrski, A. Strzelecki , et al. (5 additional authors not shown)

    Abstract: Photomultipliers are commonly used in commercial PET scanner as devices which convert light produced in scintillator by gamma quanta from positron-electron annihilation into electrical signal. For proper analysis of obtained electrical signal, a photomultiplier gain curve must be known, since gain can be significantly different even between photomultipliers of the same model. In this article we de… ▽ More

    Submitted 16 December, 2013; v1 submitted 10 December, 2013; originally announced December 2013.

    Comments: Submitted to Bio-Algorithms and Med-Systems (12 pages, 6 figures)

    Journal ref: Bio-Algorithms and Med-Systems Volume 10(1), 13-17 (2014)