-
Technical design report for the CODEX-$β$ demonstrator
Authors:
CODEX-b collaboration,
:,
Giulio Aielli,
Juliette Alimena,
James Beacham,
Eli Ben Haim,
Andras Burucs,
Roberto Cardarelli,
Matthew Charles,
Xabier Cid Vidal,
Albert De Roeck,
Biplab Dey,
Silviu Dobrescu,
Ozgur Durmus,
Mohamed Elashri,
Vladimir Gligorov,
Rebeca Gonzalez Suarez,
Thomas Gorordo,
Zarria Gray,
Conor Henderson,
Louis Henry,
Philip Ilten,
Daniel Johnson,
Jacob Kautz,
Simon Knapen
, et al. (28 additional authors not shown)
Abstract:
The CODEX-$β$ apparatus is a demonstrator for the proposed future CODEX-b experiment, a long-lived-particle detector foreseen for operation at IP8 during HL-LHC data-taking. The demonstrator project, intended to collect data in 2025, is described, with a particular focus on the design, construction, and installation of the new apparatus.
The CODEX-$β$ apparatus is a demonstrator for the proposed future CODEX-b experiment, a long-lived-particle detector foreseen for operation at IP8 during HL-LHC data-taking. The demonstrator project, intended to collect data in 2025, is described, with a particular focus on the design, construction, and installation of the new apparatus.
△ Less
Submitted 22 May, 2024;
originally announced June 2024.
-
Testbeam results of irradiated SiGe BiCMOS monolithic silicon pixel detector without internal gain layer
Authors:
T. Moretti,
M. Milanesio,
R. Cardella,
T. Kugathasan,
A. Picardi,
I. Semendyaev,
M. Elviretti,
H. Rücker,
K. Nakamura,
Y. Takubo,
M. Togawa,
F. Cadoux,
R. Cardarelli,
L. Cecconi,
S. Débieux,
Y. Favre,
C. A. Fenoglio,
D. Ferrere,
S. Gonzalez-Sevilla,
L. Iodice,
R. Kotitsa,
C. Magliocca,
M. Nessi,
A. Pizarro-Medina,
J. Sabater Iglesias
, et al. (5 additional authors not shown)
Abstract:
Samples of the monolithic silicon pixel ASIC prototype produced in 2022 within the framework of the Horizon 2020 MONOLITH ERC Advanced project were irradiated with 70 MeV protons up to a fluence of 1 x 1016 neq/cm2, and then tested using a beam of 120 GeV/c pions. The ASIC contains a matrix of 100 μm pitch hexagonal pixels, readout out by low noise and very fast frontend electronics produced in a…
▽ More
Samples of the monolithic silicon pixel ASIC prototype produced in 2022 within the framework of the Horizon 2020 MONOLITH ERC Advanced project were irradiated with 70 MeV protons up to a fluence of 1 x 1016 neq/cm2, and then tested using a beam of 120 GeV/c pions. The ASIC contains a matrix of 100 μm pitch hexagonal pixels, readout out by low noise and very fast frontend electronics produced in a 130 nm SiGe BiCMOS technology process. The dependence on the proton fluence of the efficiency and the time resolution of this prototype was measured with the frontend electronics operated at a power density between 0.13 and 0.9 W/cm2. The testbeam data show that the detection efficiency of 99.96% measured at sensor bias voltage of 200 V before irradiation becomes 96.2% after a fluence of 1 x 1016 neq/cm2. An increase of the sensor bias voltage to 300 V provides an efficiency to 99.7% at that proton fluence. The timing resolution of 20 ps measured before irradiation rises for a proton fluence of 1 x 1016 neq/cm2 to 53 and 45 ps at HV = 200 and 300 V, respectively.
△ Less
Submitted 21 June, 2024; v1 submitted 19 April, 2024;
originally announced April 2024.
-
In-beam performance of a Resistive Plate Chamber operated with eco-friendly gas mixtures
Authors:
L. Quaglia,
M. Abbrescia,
G. Aielli,
R. Aly,
M. C. Arena,
M. Barroso,
L. Benussi,
S. Bianco,
D. Boscherini,
F. Bordon,
A. Bruni,
S. Buontempo,
M. Busato,
P. Camarri,
R. Cardarelli,
L. Congedo,
D. De Jesus Damiao,
M. De Serio,
A. Di Ciaccio,
L. Di Stante,
P. Dupieux,
J. Eysermans,
A. Ferretti,
G. Galati,
M. Gagliardi
, et al. (32 additional authors not shown)
Abstract:
ALICE (A Large Ion Collider Experiment) studies the Quark-Gluon Plasma (QGP): a deconfined state of matter obtained in ultra-relativistic heavy-ion collisions. One of the probes for QGP study are quarkonia and open heavy flavour, of which ALICE exploits the muonic decay. A set of Resistive Plate Chambers (RPCs), placed in the forward rapidity region of the ALICE detector, is used for muon identifi…
▽ More
ALICE (A Large Ion Collider Experiment) studies the Quark-Gluon Plasma (QGP): a deconfined state of matter obtained in ultra-relativistic heavy-ion collisions. One of the probes for QGP study are quarkonia and open heavy flavour, of which ALICE exploits the muonic decay. A set of Resistive Plate Chambers (RPCs), placed in the forward rapidity region of the ALICE detector, is used for muon identification purposes. The correct operation of these detectors is ensured by the choice of the proper gas mixture. Currently they are operated with a mixture of C$_{2}$H$_{2}$F$_{4}$, i-C$_{4}$H$_{10}$ and SF$_{6}$ but, starting from 2017, new EU regulations have enforced a progressive phase-out of C$_{2}$H$_{2}$F$_{4}$ because of its large Global Warming Potential (GWP), making it difficult and costly to purchase. CERN asked LHC experiments to reduce greenhouse gases emissions, to which RPC operation contributes significantly. A possible candidate for C$_{2}$H$_{2}$F$_{4}$ replacement is the C$_{3}$H$_{2}$F$_{4}$ (diluted with other gases, such as CO$_{2}$), which has been extensively tested using cosmic rays. Promising gas mixtures have been devised; the next crucial steps are the detailed in-beam characterization of such mixtures as well as the study of their performance under increasing irradiation levels. This contribution will describe the methodology and results of beam tests carried out at the CERN GIF++ (equipped with a high activity $^{137}$Cs source and muon beam) with an ALICE-like RPC prototype, operated with several mixtures with varying proportions of CO$_{2}$, C$_{3}$H$_{2}$F$_{4}$, i-C$_{4}$H$_{10}$ and SF$_{6}$ . Absorbed currents, efficiencies, prompt charges, cluster sizes, time resolutions and rate capabilities will be presented, both from digitized (for detailed shape and charge analysis) and discriminated (using the same front-end electronics as employed in ALICE) signals.
△ Less
Submitted 29 February, 2024;
originally announced February 2024.
-
Exploring Eco-Friendly Gas Mixtures for Resistive Plate Chambers: A Comprehensive Study on Performance and Aging
Authors:
The RPC ECOGas@GIF++ collaboration,
:,
L. Quaglia,
M. Abbrescia,
G. Aielli,
R. Aly,
M. C. Arena,
M. Barroso,
L. Benussi,
S. Bianco,
D. Boscherini,
F. Bordon,
A. Bruni,
S. Buontempo,
M. Busato,
P. Camarri,
R. Cardarelli,
L. Congedo,
D. De Jesus Damiao,
M. De Serio,
A. Di Ciaccio,
L. Di Stante,
P. Dupieux,
J. Eysermans,
A. Ferretti
, et al. (35 additional authors not shown)
Abstract:
Resistive Plate Chambers (RPCs) are gaseous detectors widely used in high energy physics experiments, operating with a gas mixture primarily containing Tetrafluoroethane (C$_{2}$H$_{2}$F$_{4}$), commonly known as R-134a, which has a global warming potential (GWP) of 1430. To comply with European regulations and explore environmentally friendly alternatives, the RPC EcoGas@GIF++ collaboration, invo…
▽ More
Resistive Plate Chambers (RPCs) are gaseous detectors widely used in high energy physics experiments, operating with a gas mixture primarily containing Tetrafluoroethane (C$_{2}$H$_{2}$F$_{4}$), commonly known as R-134a, which has a global warming potential (GWP) of 1430. To comply with European regulations and explore environmentally friendly alternatives, the RPC EcoGas@GIF++ collaboration, involving ALICE, ATLAS, CMS, LHCb/SHiP, and EP-DT communities, has undertaken intensive R\&D efforts to explore new gas mixtures for RPC technology.
A leading alternative under investigation is HFO1234ze, boasting a low GWP of 6 and demonstrating reasonable performance compared to R-134a. Over the past few years, RPC detectors with slightly different characteristics and electronics have been studied using HFO and CO$_{2}$-based gas mixtures at the CERN Gamma Irradiation Facility. An aging test campaign was launched in August 2022, and during the latest test beam in July 2023, all detector systems underwent evaluation. This contribution will report the results of the aging studies and the performance evaluations of the detectors with and without irradiation.
△ Less
Submitted 29 February, 2024;
originally announced February 2024.
-
Time Resolution of a SiGe BiCMOS Monolithic Silicon Pixel Detector without Internal Gain Layer with a Femtosecond Laser
Authors:
M. Milanesio,
L. Paolozzi,
T. Moretti,
A. Latshaw,
L. Bonacina,
R. Cardella,
T. Kugathasan,
A. Picardi,
M. Elviretti,
H. Rücker,
R. Cardarelli,
L. Cecconi,
C. A. Fenoglio,
D. Ferrere,
S. Gonzalez-Sevilla,
L. Iodice,
R. Kotitsa,
C. Magliocca,
M. Nessi,
A. Pizarro-Medina,
J. Sabater Iglesias,
I. Semendyaev,
J. Saidi,
M. Vicente Barreto Pinto,
S. Zambito
, et al. (1 additional authors not shown)
Abstract:
The time resolution of the second monolithic silicon pixel prototype produced for the MONOLITH H2020 ERC Advanced project was studied using a femtosecond laser. The ASIC contains a matrix of hexagonal pixels with 100 μm pitch, readout by low-noise and very fast SiGe HBT frontend electronics. Silicon wafers with 50 μm thick epilayer with a resistivity of 350 Ωcm were used to produce a fully deplete…
▽ More
The time resolution of the second monolithic silicon pixel prototype produced for the MONOLITH H2020 ERC Advanced project was studied using a femtosecond laser. The ASIC contains a matrix of hexagonal pixels with 100 μm pitch, readout by low-noise and very fast SiGe HBT frontend electronics. Silicon wafers with 50 μm thick epilayer with a resistivity of 350 Ωcm were used to produce a fully depleted sensor. At the highest frontend power density tested of 2.7 W/cm2, the time resolution with the femtosecond laser pulses was found to be 45 ps for signals generated by 1200 electrons, and 3 ps in the case of 11k electrons, which corresponds approximately to 0.4 and 3.5 times the most probable value of the charge generated by a minimum-ionizing particle. The results were compared with testbeam data taken with the same prototype to evaluate the time jitter produced by the fluctuations of the charge collection.
△ Less
Submitted 11 February, 2024; v1 submitted 2 January, 2024;
originally announced January 2024.
-
Preliminary results on the long term operation of RPCs with eco-friendly gas mixtures under irradiation at the CERN Gamma Irradiation Facility
Authors:
L. Quaglia,
D. Ramos,
M. Abbrescia,
G. Aielli,
R. Aly,
M. C. Arena,
M. Barroso,
L. Benussi,
S. Bianco,
D. Boscherini,
F. Bordon,
A. Bruni,
S. Buontempo,
M. Busato,
P. Camarri,
R. Cardarelli,
L. Congedo,
D. De Jesus Damiao,
M. De Serio,
A. Di Ciacco,
L. Di Stante,
P. Dupieux,
J. Eysermans,
A. Ferretti,
G. Galati
, et al. (33 additional authors not shown)
Abstract:
Since 2019 a collaboration between researchers from various institutes and experiments (i.e. ATLAS, CMS, ALICE, LHCb/SHiP and the CERN EP-DT group), has been operating several RPCs with diverse electronics, gas gap thicknesses and detector layouts at the CERN Gamma Irradiation Facility (GIF++). The studies aim at assessing the performance of RPCs when filled with new eco-friendly gas mixtures in a…
▽ More
Since 2019 a collaboration between researchers from various institutes and experiments (i.e. ATLAS, CMS, ALICE, LHCb/SHiP and the CERN EP-DT group), has been operating several RPCs with diverse electronics, gas gap thicknesses and detector layouts at the CERN Gamma Irradiation Facility (GIF++). The studies aim at assessing the performance of RPCs when filled with new eco-friendly gas mixtures in avalanche mode and in view of evaluating possible ageing effects after long high background irradiation periods, e.g. High-Luminosity LHC phase. This challenging research is also part of a task of the European AidaInnova project.
A promising eco-friendly gas identified for RPC operation is the tetrafluoruropropene (C$_{3}$H$_{2}$F$_{4}$, commercially known as HFO-1234ze) that has been studied at the CERN GIF++ in combination with different percentages of CO$_2$. Between the end of 2021 and 2022 several beam tests have been carried out to establish the performance of RPCs operated with such mixtures before starting the irradiation campaign for the ageing study.
Results of these tests for different RPCs layouts and different gas mixtures, under increasing background rates are presented here, together with the preliminary outcome of the detector ageing tests.
△ Less
Submitted 29 November, 2023;
originally announced November 2023.
-
High-rate tests on Resistive Plate Chambers operated with eco-friendly gas mixtures
Authors:
M. Abbrescia,
G. Aielli,
R. Aly,
M. C. Arena,
M. Barroso,
L. Benussi,
S. Bianco,
F. Bordon,
D. Boscherini,
A. Bruni,
S. Buontempo,
M. Busato,
P. Camarri,
R. Cardarelli,
L. Congedo,
D. De Jesus Damiao,
M. De Serio,
A. Di Ciaccio,
L. Di Stante,
P. Dupieux,
J. Eysermans,
A. Ferretti,
G. Galati,
M. Gagliardi,
R. Guida
, et al. (30 additional authors not shown)
Abstract:
Results obtained by the RPC ECOgas@GIF++ Collaboration, using Resistive Plate Chambers operated with new, eco-friendly gas mixtures, based on Tetrafluoropropene and carbon dioxide, are shown and discussed in this paper. Tests aimed to assess the performance of this kind of detectors in high-irradiation conditions, analogous to the ones foreseen for the coming years at the Large Hadron Collider exp…
▽ More
Results obtained by the RPC ECOgas@GIF++ Collaboration, using Resistive Plate Chambers operated with new, eco-friendly gas mixtures, based on Tetrafluoropropene and carbon dioxide, are shown and discussed in this paper. Tests aimed to assess the performance of this kind of detectors in high-irradiation conditions, analogous to the ones foreseen for the coming years at the Large Hadron Collider experiments, were performed, and demonstrate a performance basically similar to the one obtained with the gas mixtures currently in use, based on Tetrafluoroethane, which is being progressively phased out for its possible contribution to the greenhouse effect. Long term aging tests are also being carried out, with the goal to demonstrate the possibility of using these eco-friendly gas mixtures during the whole High Luminosity phase of the Large Hadron Collider.
△ Less
Submitted 14 November, 2023;
originally announced November 2023.
-
Cosmic-ray searches with the MATHUSLA detector
Authors:
Cristiano Alpigiani,
J. C. Arteaga-Velázquez,
Daniela Blanco-Lira,
Davide Boscherini,
K. S. Caballero-Mora,
Paolo Camarri,
Roberto Cardarelli,
Dennis Cazar Ramírez,
Giuseppe Di Sciascio,
Arturo Fernández Téllez,
H. J. Lubatti,
O. G. Morales-Olivares,
Piter Amador Paye Mamani,
David Rivera Rangel,
Mario Rodríguez-Cahuantzi,
Rinaldo Santonico,
Martin Alfonso Subieta Vázquez
Abstract:
The performance of the proposed MATHUSLA detector as an instrument for studying the physics of cosmic rays by measuring extensive air showers is presented. The MATHUSLA detector is designed to observe and study the decay of long-lived particles produced at the pp interaction point of the CMS detector at CERN during the HL-LHC data-taking period. The proposed MATHUSLA detector will be composed of m…
▽ More
The performance of the proposed MATHUSLA detector as an instrument for studying the physics of cosmic rays by measuring extensive air showers is presented. The MATHUSLA detector is designed to observe and study the decay of long-lived particles produced at the pp interaction point of the CMS detector at CERN during the HL-LHC data-taking period. The proposed MATHUSLA detector will be composed of many layers of long scintillating bars that cannot measure more than one hit per bar and correctly report the hit coordinate in case of multiple hits. This study shows that adding a layer of RPC detectors with both analogue and digital readout significantly enhances the capabilities of MATHUSLA to measure the local densities and arrival times of charged particles at the front of air showers. We discuss open issues in cosmic-ray physics that the proposed MATHUSLA detector with an additional layer of RPC detectors could address and conclude by comparing with other air-shower facilities that measure cosmic rays in the PeV energy range.
△ Less
Submitted 13 November, 2023;
originally announced November 2023.
-
Radiation Tolerance of SiGe BiCMOS Monolithic Silicon Pixel Detectors without Internal Gain Layer
Authors:
M. Milanesio,
L. Paolozzi,
T. Moretti,
R. Cardella,
T. Kugathasan,
F. Martinelli,
A. Picardi,
I. Semendyaev,
S. Zambito,
K. Nakamura,
Y. Tabuko,
M. Togawa,
M. Elviretti,
H. Rücker,
F. Cadoux,
R. Cardarelli,
S. Débieux,
Y. Favre,
C. A. Fenoglio,
D. Ferrere,
S. Gonzalez-Sevilla,
L. Iodice,
R. Kotitsa,
C. Magliocca,
M. Nessi
, et al. (5 additional authors not shown)
Abstract:
A monolithic silicon pixel prototype produced for the MONOLITH ERC Advanced project was irradiated with 70 MeV protons up to a fluence of 1 x 10^16 1 MeV n_eq/cm^2. The ASIC contains a matrix of hexagonal pixels with 100 μm pitch, readout by low-noise and very fast SiGe HBT frontend electronics. Wafers with 50 μm thick epilayer with a resistivity of 350 Ωcm were used to produce a fully depleted se…
▽ More
A monolithic silicon pixel prototype produced for the MONOLITH ERC Advanced project was irradiated with 70 MeV protons up to a fluence of 1 x 10^16 1 MeV n_eq/cm^2. The ASIC contains a matrix of hexagonal pixels with 100 μm pitch, readout by low-noise and very fast SiGe HBT frontend electronics. Wafers with 50 μm thick epilayer with a resistivity of 350 Ωcm were used to produce a fully depleted sensor. Laboratory tests conducted with a 90Sr source show that the detector works satisfactorily after irradiation. The signal-to-noise ratio is not seen to change up to fluence of 6 x 10^14 n_eq /cm^2 . The signal time jitter was estimated as the ratio between the voltage noise and the signal slope at threshold. At -35 {^\circ}C, sensor bias voltage of 200 V and frontend power consumption of 0.9 W/cm^2, the time jitter of the most-probable signal amplitude was estimated to be 21 ps for proton fluence up to 6 x 10 n_eq/cm^2 and 57 ps at 1 x 10^16 n_eq/cm^2 . Increasing the sensor bias to 250 V and the analog voltage of the preamplifier from 1.8 to 2.0 V provides a time jitter of 40 ps at 1 x 10^16 n_eq/cm^2.
△ Less
Submitted 30 October, 2023;
originally announced October 2023.
-
20 ps Time Resolution with a Fully-Efficient Monolithic Silicon Pixel Detector without Internal Gain Layer
Authors:
S. Zambito,
M. Milanesio,
T. Moretti,
L. Paolozzi,
M. Munker,
R. Cardella,
T. Kugathasan,
F. Martinelli,
A. Picardi,
M. Elviretti,
H. Rücker,
A. Trusch,
F. Cadoux,
R. Cardarelli,
S. Débieux,
Y. Favre,
C. A. Fenoglio,
D. Ferrere,
S. Gonzalez-Sevilla,
L. Iodice,
R. Kotitsa,
C. Magliocca,
M. Nessi,
A. Pizarro-Medina,
J. Sabater Iglesias
, et al. (3 additional authors not shown)
Abstract:
A second monolithic silicon pixel prototype was produced for the MONOLITH project. The ASIC contains a matrix of hexagonal pixels with 100 μm pitch, readout by a low-noise and very fast SiGe HBT frontend electronics. Wafers with 50 μm thick epilayer of 350 Ωcm resistivity were used to produce a fully depleted sensor. Laboratory and testbeam measurements of the analog channels present in the pixel…
▽ More
A second monolithic silicon pixel prototype was produced for the MONOLITH project. The ASIC contains a matrix of hexagonal pixels with 100 μm pitch, readout by a low-noise and very fast SiGe HBT frontend electronics. Wafers with 50 μm thick epilayer of 350 Ωcm resistivity were used to produce a fully depleted sensor. Laboratory and testbeam measurements of the analog channels present in the pixel matrix show that the sensor has a 130 V wide bias-voltage operation plateau at which the efficiency is 99.8%. Although this prototype does not include an internal gain layer, the design optimised for timing of the sensor and the front-end electronics provides a time resolutions of 20 ps.
△ Less
Submitted 28 January, 2023;
originally announced January 2023.
-
Searching for an eco-friendly gas mixture for the ALICE Resistive Plate Chambers
Authors:
Luca Quaglia,
R. Cardarelli,
B. Liberti,
E. Pastori,
G. Proto,
G. Aielli,
P. Camarri,
A. Di Ciacco,
L. Di Stante,
R. Santonico,
G. Alberghi,
D. Boscherini,
A. Bruni,
L. Massa,
A. Polini,
M. Romano,
L. Benussi,
S. Bianco,
L. Passamonti,
D. Piccolo,
D. Pierluigi,
A. Russo M. Ferrini,
G. Saviano,
M. Abbrescia,
L. Congedo
, et al. (25 additional authors not shown)
Abstract:
The ALICE RPCs are operated with a mixture of 89.7% $C_{2}H_{2}F_{4}$, 10% i-$C_{4}H_{10}$ and 0.3% $SF_{6}$. $C_{2}H_{2}F_{4}$ and $SF_{6}$ are fluorinated greenhouse gases with a high Global Warming Potential (GWP). New European Union regulations have imposed a progressive phase-down of the production and usage of F-gases, aiming to cut down their emission by two thirds in 2030 with respect to 2…
▽ More
The ALICE RPCs are operated with a mixture of 89.7% $C_{2}H_{2}F_{4}$, 10% i-$C_{4}H_{10}$ and 0.3% $SF_{6}$. $C_{2}H_{2}F_{4}$ and $SF_{6}$ are fluorinated greenhouse gases with a high Global Warming Potential (GWP). New European Union regulations have imposed a progressive phase-down of the production and usage of F-gases, aiming to cut down their emission by two thirds in 2030 with respect to 2014. Even though research activities are excluded from these regulations, the phase-down will inevitably increase their price and CERN is also aiming to cut down on its emissions. For these reasons it is crucial to find a more eco-friendly gas mixture for RPCs by the time of the LHC long shutdown 3, foreseen in 2026. Since $C_{2}H_{2}F_{4}$ is the main contributor to the mixture GWP, an extensive R&D process has started to replace it with tetrafluoropropene ($C_{3}H_{2}F_{4}$), due to its chemical similarity with $C_{2}H_{2}F_{4}$ and its low GWP (around 7). Preliminary tests with cosmic rays have shown promising results in terms of detector performance. The next step is to study the long-term behavior of RPCs operated with these new gas mixtures (aging studies). Since this is a subject of interest for all (and not only) the LHC experiments, a collaboration, ECOgas@GIF++, was setup to carry out joint studies. Among others, a small ALICE-like RPC was installed at the Gamma Irradiation Facility at CERN, where they are exposed to a strong radiation field, coming from a 12.5 TBq $^{137}$Cs source, which allows one to simulate many years of operation in a relatively short time. The facility also provides a muon beam at specific times of the year, which can be used to study the detector performance (e.g. efficiency and cluster size) during and after irradiation.
△ Less
Submitted 5 September, 2022;
originally announced September 2022.
-
Testbeam Results of the Picosecond Avalanche Detector Proof-Of-Concept Prototype
Authors:
G. Iacobucci,
S. Zambito,
M. Milanesio,
T. Moretti,
J. Saidi,
L. Paolozzi,
M. Munker,
R. Cardella,
F. Martinelli,
A. Picardi,
H. Rücker,
A. Trusch,
P. Valerio,
F. Cadoux,
R. Cardarelli,
S. Débieux,
Y. Favre,
C. A. Fenoglio,
D. Ferrere,
S. Gonzalez-Sevilla,
Y. Gurimskaya,
R. Kotitsa,
C. Magliocca,
M. Nessi,
A. Pizarro-Medina
, et al. (2 additional authors not shown)
Abstract:
The proof-of-concept prototype of the Picosecond Avalanche Detector, a multi-PN junction monolithic silicon detector with continuous gain layer deep in the sensor depleted region, was tested with a beam of 180 GeV pions at the CERN SPS. The prototype features low noise and fast SiGe BiCMOS frontend electronics and hexagonal pixels with 100 μm pitch. At a sensor bias voltage of 125 V, the detector…
▽ More
The proof-of-concept prototype of the Picosecond Avalanche Detector, a multi-PN junction monolithic silicon detector with continuous gain layer deep in the sensor depleted region, was tested with a beam of 180 GeV pions at the CERN SPS. The prototype features low noise and fast SiGe BiCMOS frontend electronics and hexagonal pixels with 100 μm pitch. At a sensor bias voltage of 125 V, the detector provides full efficiency and average time resolution of 30, 25 and 17 ps in the overall pixel area for a power consumption of 0.4, 0.9 and 2.7 W/cm^2, respectively. In this first prototype the time resolution depends significantly on the distance from the center of the pixel, varying at the highest power consumption measured between 13 ps at the center of the pixel and 25 ps in the inter-pixel region.
△ Less
Submitted 23 August, 2022;
originally announced August 2022.
-
Picosecond Avalanche Detector -- working principle and gain measurement with a proof-of-concept prototype
Authors:
L. Paolozzi,
M. Munker,
R. Cardella,
M. Milanesio,
Y. Gurimskaya,
F. Martinelli,
A. Picardi,
H. Rücker,
A. Trusch,
P. Valerio,
F. Cadoux,
R. Cardarelli,
S. Débieux,
Y. Favre,
C. A. Fenoglio,
D. Ferrere,
S. Gonzalez-Sevilla,
R. Kotitsa,
C. Magliocca,
T. Moretti,
M. Nessi,
A. Pizarro Medina,
J. Sabater Iglesias,
J. Saidi,
M. Vicente Barreto Pinto
, et al. (2 additional authors not shown)
Abstract:
The Picosecond Avalanche Detector is a multi-junction silicon pixel detector based on a $\mathrm{(NP)_{drift}(NP)_{gain}}$ structure, devised to enable charged-particle tracking with high spatial resolution and picosecond time-stamp capability. It uses a continuous junction deep inside the sensor volume to amplify the primary charge produced by ionizing radiation in a thin absorption layer. The si…
▽ More
The Picosecond Avalanche Detector is a multi-junction silicon pixel detector based on a $\mathrm{(NP)_{drift}(NP)_{gain}}$ structure, devised to enable charged-particle tracking with high spatial resolution and picosecond time-stamp capability. It uses a continuous junction deep inside the sensor volume to amplify the primary charge produced by ionizing radiation in a thin absorption layer. The signal is then induced by the secondary charges moving inside a thicker drift region. A proof-of-concept monolithic prototype, consisting of a matrix of hexagonal pixels with 100 $μ$m pitch, has been produced using the 130 nm SiGe BiCMOS process by IHP microelectronics. Measurements on probe station and with a $^{55}$Fe X-ray source show that the prototype is functional and displays avalanche gain up to a maximum electron gain of 23. A study of the avalanche characteristics, corroborated by TCAD simulations, indicates that space-charge effects due to the large primary charge produced by the conversion of X-rays from the $^{55}$Fe source limits the effective gain.
△ Less
Submitted 25 September, 2022; v1 submitted 16 June, 2022;
originally announced June 2022.
-
Efficiency and time resolution of monolithic silicon pixel detectors in SiGe BiCMOS technology
Authors:
G. Iacobucci,
L. Paolozzi,
P. Valerio,
T. Moretti,
F. Cadoux,
R. Cardarelli,
R. Cardella,
S. Débieux,
Y. Favre,
D. Ferrere,
S. Gonzalez-Sevilla,
Y. Gurimskaya,
R. Kotitsa,
C. Magliocca,
F. Martinelli,
M. Milanesio,
M. Münker,
M. Nessi,
A. Picardi,
J. Saidi,
H. Rücker,
M. Vicente Barreto Pinto,
S. Zambito
Abstract:
A monolithic silicon pixel detector prototype has been produced in the SiGe BiCMOS SG13G2 130 nm node technology by IHP. The ASIC contains a matrix of hexagonal pixels with pitch of approximately 100 $μ$m. Three analog pixels were calibrated in laboratory with radioactive sources and tested in a 180 GeV/c pion beamline at the CERN SPS. A detection efficiency of $\left(99.9^{+0.1}_{-0.2}\right)$% w…
▽ More
A monolithic silicon pixel detector prototype has been produced in the SiGe BiCMOS SG13G2 130 nm node technology by IHP. The ASIC contains a matrix of hexagonal pixels with pitch of approximately 100 $μ$m. Three analog pixels were calibrated in laboratory with radioactive sources and tested in a 180 GeV/c pion beamline at the CERN SPS. A detection efficiency of $\left(99.9^{+0.1}_{-0.2}\right)$% was measured together with a time resolution of $(36.4 \pm 0.8)$ps at the highest preamplifier bias current working point of 150 $μ$A and at a sensor bias voltage of 160 V. The ASIC was also characterized at lower bias voltage and preamplifier current.
△ Less
Submitted 21 January, 2022; v1 submitted 16 December, 2021;
originally announced December 2021.
-
On a new environment-friendly gas mixture for Resistive Plate Chambers
Authors:
G. Proto,
B. Liberti,
R. Santonico,
G. Aielli,
P. Camarri,
R. Cardarelli,
A. Di Ciaccio,
L. Di Stante,
A. Paoloni,
E. Pastori,
L. Pizzimento,
A. Rocchi
Abstract:
This paper studies the performance of RPCs working with a new family of environment-friendly operating gases, mainly based on Carbon Dioxide and Hydro-Fluoro-Olefins. The tests are carried out on a 2 mm gap RPC and concern the measurement of detection efficiency, avalanche-to-streamer transition probability, prompt and ionic charge delivered. The timing properties of the new gas are also measured.
This paper studies the performance of RPCs working with a new family of environment-friendly operating gases, mainly based on Carbon Dioxide and Hydro-Fluoro-Olefins. The tests are carried out on a 2 mm gap RPC and concern the measurement of detection efficiency, avalanche-to-streamer transition probability, prompt and ionic charge delivered. The timing properties of the new gas are also measured.
△ Less
Submitted 13 December, 2021; v1 submitted 5 December, 2021;
originally announced December 2021.
-
A massively scalable Time-to-Digital Converter with a PLL-free calibration system in a commercial 130 nm process
Authors:
Fulvio Martinelli,
Pierpaolo Valerio,
Roberto Cardarelli,
Edoardo Charbon,
Giuseppe Iacobucci,
Marzio Nessi,
Lorenzo Paolozzi
Abstract:
A 33.6 ps LSB Time-to-Digital converter was designed in 130 nm BiCMOS technology. The core of the converter is a differential 9-stage ring oscillator, based on a multi-path architecture. A novel version of this design is proposed, along with an analytical model of linearity. The model allowed us to understand the source of the performance superiority (in terms of linearity) of our design and to pr…
▽ More
A 33.6 ps LSB Time-to-Digital converter was designed in 130 nm BiCMOS technology. The core of the converter is a differential 9-stage ring oscillator, based on a multi-path architecture. A novel version of this design is proposed, along with an analytical model of linearity. The model allowed us to understand the source of the performance superiority (in terms of linearity) of our design and to predict further improvements. The oscillator is integrated in a event-by-event self-calibration system that allows avoiding any PLL-based synchronization. For this reason and for the compactness and simplicity of the architecture, the proposed TDC is suitable for applications in which a large number of converters and a massive parallelization are required such as High-Energy Physics and medical imaging detector systems. A test chip for the TDC has been fabricated and tested. The TDC shows a DNL$\leq$1.3 LSB, an INL$\leq$2 LSB and a single-shot precision of 19.5 ps (0.58 LSB). The chip dissipates a power of 5.4 mW overall.
△ Less
Submitted 1 September, 2021; v1 submitted 21 July, 2021;
originally announced July 2021.
-
An Update to the Letter of Intent for MATHUSLA: Search for Long-Lived Particles at the HL-LHC
Authors:
Cristiano Alpigiani,
Juan Carlos Arteaga-Velázquez,
Austin Ball,
Liron Barak,
Jared Barron,
Brian Batell,
James Beacham,
Yan Benhammo,
Karen Salomé Caballero-Mora,
Paolo Camarri,
Roberto Cardarelli,
John Paul Chou,
Wentao Cui,
David Curtin,
Miriam Diamond,
Keith R. Dienes,
Liam Andrew Dougherty,
Giuseppe Di Sciascio,
Marco Drewes,
Erez Etzion,
Rouven Essig,
Jared Evans,
Arturo Fernández Téllez,
Oliver Fischer,
Jim Freeman
, et al. (58 additional authors not shown)
Abstract:
We report on recent progress in the design of the proposed MATHUSLA Long Lived Particle (LLP) detector for the HL-LHC, updating the information in the original Letter of Intent (LoI), see CDS:LHCC-I-031, arXiv:1811.00927. A suitable site has been identified at LHC Point 5 that is closer to the CMS Interaction Point (IP) than assumed in the LoI. The decay volume has been increased from 20 m to 25 m…
▽ More
We report on recent progress in the design of the proposed MATHUSLA Long Lived Particle (LLP) detector for the HL-LHC, updating the information in the original Letter of Intent (LoI), see CDS:LHCC-I-031, arXiv:1811.00927. A suitable site has been identified at LHC Point 5 that is closer to the CMS Interaction Point (IP) than assumed in the LoI. The decay volume has been increased from 20 m to 25 m in height. Engineering studies have been made in order to locate much of the decay volume below ground, bringing the detector even closer to the IP. With these changes, a 100 m x 100 m detector has the same physics reach for large c$τ$ as the 200 m x 200 m detector described in the LoI and other studies. The performance for small c$τ$ is improved because of the proximity to the IP. Detector technology has also evolved while retaining the strip-like sensor geometry in Resistive Plate Chambers (RPC) described in the LoI. The present design uses extruded scintillator bars read out using wavelength shifting fibers and silicon photomultipliers (SiPM). Operations will be simpler and more robust with much lower operating voltages and without the use of greenhouse gases. Manufacturing is straightforward and should result in cost savings. Understanding of backgrounds has also significantly advanced, thanks to new simulation studies and measurements taken at the MATHUSLA test stand operating above ATLAS in 2018. We discuss next steps for the MATHUSLA collaboration, and identify areas where new members can make particularly important contributions.
△ Less
Submitted 3 September, 2020;
originally announced September 2020.
-
Characterization of new eco friendly gas mixtures based on HFO for RPCs
Authors:
G. Proto,
G. Aielli,
E. Alunno Camelia,
P. Camarri,
R. Cardarelli,
A. Di Ciaccio,
L. Di Stante,
B. Liberti,
A. Paoloni,
E. Pastori,
L. Pizzimento,
A. Rocchi,
R. Santonico,
E. Tusi
Abstract:
The ATLAS RPC standard mixture, mainly based on C$_{2}$H$_{2}$F$_{4}$, has a high Global Warming Potential (GWP) and therefore the search for RPC eco friendly gases is mandatory. In this work we present the results on the detector performances in terms of efficiency, prompt and ionic charge, with different gas mixtures.
The ATLAS RPC standard mixture, mainly based on C$_{2}$H$_{2}$F$_{4}$, has a high Global Warming Potential (GWP) and therefore the search for RPC eco friendly gases is mandatory. In this work we present the results on the detector performances in terms of efficiency, prompt and ionic charge, with different gas mixtures.
△ Less
Submitted 30 May, 2020;
originally announced June 2020.
-
Linearity and rate capability measurements of RPC with semi-insulating crystalline electrodes operating in avalanche mode
Authors:
A. Rocchi,
R. Cardarelli,
B. Liberti,
G. Aielli,
E. Alunno Camelia,
P. Camarri,
M. Cirillo,
A. Di Ciaccio,
L. Di Stante,
M. Lucci,
E. Pastori,
L. Pizzimento,
G. Proto,
E. Tusi,
R. Santonico
Abstract:
The intrinsic rate capability and the ageing properties of the Resistive Plate Chambers are closely related to the electrodes material and to the front-end electronics threshold. The development of a low noise pre-amplifier led us to improve the intrinsic rate capability of High Pressure Laminate (bakelite) up to $\sim10\;kHz/cm^2$, nevertheless the effective rate is significantly limited by elect…
▽ More
The intrinsic rate capability and the ageing properties of the Resistive Plate Chambers are closely related to the electrodes material and to the front-end electronics threshold. The development of a low noise pre-amplifier led us to improve the intrinsic rate capability of High Pressure Laminate (bakelite) up to $\sim10\;kHz/cm^2$, nevertheless the effective rate is significantly limited by electrodes ageing. To further improve the effective rate capability new materials are investigated. A Resistive Plate Chamber with crystalline semi-insulating Gallium Arsenide electrodes has been characterized with high energy electrons beam at the Beam Test Facility (BFT), (INFN National Laboratory of Frascati, Italy). The response of the Resistive Plate Chamber to multiple bunched electrons was measured operating the detector in avalanche mode. The intrinsic rate capability has been also measured operating the detector in a uniform high energy gamma radiation field at the GIF++ facility (EHN1 of SPS, CERN).
△ Less
Submitted 30 May, 2020;
originally announced June 2020.
-
Time resolution and power consumption of a monolithic silicon pixel prototype in SiGe BiCMOS technology
Authors:
L. Paolozzi,
R. Cardarelli,
S. Débieux,
Y. Favre,
D. Ferrère,
S. Gonzalez-Sevilla,
G. Iacobucci,
M. Kaynak,
F. Martinelli,
M. Nessi,
H. Rücker,
I. Sanna,
DMS Sultan,
P. Valerio,
E. Zaffaroni
Abstract:
SiGe BiCMOS technology can be used to produce ultra-fast, low-power silicon pixel sensors that provide state-of-the-art time resolution even without an internal gain mechanism. The development of such sensors requires the identification of the main factors that may degrade the timing performance and the characterisation of the dependance of the sensor time resolution on the amplifier power consump…
▽ More
SiGe BiCMOS technology can be used to produce ultra-fast, low-power silicon pixel sensors that provide state-of-the-art time resolution even without an internal gain mechanism. The development of such sensors requires the identification of the main factors that may degrade the timing performance and the characterisation of the dependance of the sensor time resolution on the amplifier power consumption. Measurements with a $ \mathrm{^{90}Sr} $ source of a prototype sensor produced in SG13G2 technology from IHP Microelectronics, shows a time resolution of 140 ps at an amplifier current of 7 $ \mathrmμ $A and 45 ps at higher power consumption. A full simulation shows that the resolution on the measurement of the signal time-over-threshold, used to correct for time walk, is the main factor affecting the timing performance.
△ Less
Submitted 28 August, 2020; v1 submitted 28 May, 2020;
originally announced May 2020.
-
The MATHUSLA Test Stand
Authors:
Maf Alidra,
Cristiano Alpigiani,
Austin Ball,
Paolo Camarri,
Roberto Cardarelli,
John Paul Chou,
David Curtin,
Erez Etzion,
Ali Garabaglu,
Brandon Gomes,
Roberto Guida,
W. Kuykendall,
Audrey Kvam,
Dragoslav Lazic,
H. J. Lubatti,
Giovanni Marsella,
Gilad Mizrachi,
Antonio Policicchio,
Mason Proffitt,
Joe Rothberg,
Rinaldo Santonico,
Yiftah Silver,
Steffie Ann Thayil,
Emma Torro-Pastor,
Gordon Watts
, et al. (1 additional authors not shown)
Abstract:
The rate of muons from LHC $pp$ collisions reaching the surface above the ATLAS interaction point is measured and compared with expected rates from decays of $W$ and $Z$ bosons and $b$- and $c$-quark jets. In addition, data collected during periods without beams circulating in the LHC provide a measurement of the background from cosmic ray inelastic backscattering that is compared to simulation pr…
▽ More
The rate of muons from LHC $pp$ collisions reaching the surface above the ATLAS interaction point is measured and compared with expected rates from decays of $W$ and $Z$ bosons and $b$- and $c$-quark jets. In addition, data collected during periods without beams circulating in the LHC provide a measurement of the background from cosmic ray inelastic backscattering that is compared to simulation predictions. Data were recorded during 2018 in a 2.5 $\times$ 2.5 $\times$ 6.5~$\rm{m}^3$ active volume MATHUSLA test stand detector unit consisting of two scintillator planes, one at the top and one at the bottom, which defined the trigger, and six layers of RPCs between them, grouped into three $(x,y)$-measuring layers separated by 1.74 m from each other. Triggers selecting both upward-going tracks and downward-going tracks were used.
△ Less
Submitted 9 September, 2020; v1 submitted 5 May, 2020;
originally announced May 2020.
-
A 50 ps resolution monolithic active pixel sensor without internal gain in SiGe BiCMOS technology
Authors:
G. Iacobucci,
R. Cardarelli,
S. Débieux,
F. A. Di Bello,
Y. Favre,
D. Hayakawa,
M. Kaynak,
M. Nessi,
L. Paolozzi,
H. Rücker,
DMS Sultan,
P. Valerio
Abstract:
A monolithic pixelated silicon detector designed for high time resolution has been produced in the SG13G2 130 nm SiGe BiCMOS technology of IHP Mikroelektronik. This proof-of-concept chip contains hexagonal pixels of 65 μm and 130 μm side. The SiGe front-end electronics implemented provides an equivalent noise charge of 90 and 160 electrons for a pixel capacitance of 70 and 220 fF, respectively, an…
▽ More
A monolithic pixelated silicon detector designed for high time resolution has been produced in the SG13G2 130 nm SiGe BiCMOS technology of IHP Mikroelektronik. This proof-of-concept chip contains hexagonal pixels of 65 μm and 130 μm side. The SiGe front-end electronics implemented provides an equivalent noise charge of 90 and 160 electrons for a pixel capacitance of 70 and 220 fF, respectively, and a total time walk of less than 1 ns. Lab measurements with a 90Sr source show a time resolution of the order of 50 ps. This result is competitive with silicon technologies that integrate an avalanche gain mechanism.
△ Less
Submitted 26 August, 2019;
originally announced August 2019.
-
Characterization of the demonstrator of the fast silicon monolithic ASIC for the TT-PET project
Authors:
Lorenzo Paolozzi,
Yves Bandi,
Roberto Cardarelli,
Stephane Debieux,
Yannick Favre,
Didier Ferrere,
Dean Forshaw,
Daiki Hayakawa,
Giuseppe Iacobucci,
Mehmet Kaynak,
Antonio Miucci,
Marzio Nessi,
Emanuele Ripiccini,
Holger Ruecker,
Pierpaolo Valerio,
Michele Weber
Abstract:
The TT-PET collaboration is developing a small animal TOF-PET scanner based on monolithic silicon pixel sensors in SiGe BiCMOS technology. The demonstrator chip, a small-scale version of the final detector ASIC, consists of a 3 x 10 pixel matrix integrated with the front-end, a 50 ps binning TDC and read out logic. The chip, thinned down to 100 μm and backside metallized, was operated at a voltage…
▽ More
The TT-PET collaboration is developing a small animal TOF-PET scanner based on monolithic silicon pixel sensors in SiGe BiCMOS technology. The demonstrator chip, a small-scale version of the final detector ASIC, consists of a 3 x 10 pixel matrix integrated with the front-end, a 50 ps binning TDC and read out logic. The chip, thinned down to 100 μm and backside metallized, was operated at a voltage of 180 V. The tests on a beam line of minimum ionizing particles show a detection efficiency greater than 99.9 % and a time resolution down to 110 ps.
△ Less
Submitted 27 November, 2018;
originally announced November 2018.
-
A monolithic ASIC demonstrator for the Thin Time-of-Flight PET scanner
Authors:
Pierpaolo Valerio,
Roberto Cardarelli,
Giuseppe Iacobucci,
Lorenzo Paolozzi,
Emanuele Ripiccini,
Daiki Hayakawa,
Salvatore Bruno,
Alessandro Caltabiano,
Mehmet Kaynak,
Holger Rueker,
Marzio Nessi
Abstract:
Time-of-flight measurement is an important advancement in PET scanners to improve image reconstruction with a lower delivered radiation dose. This article describes the monolithic ASIC for the TT-PET project, a novel idea for a high-precision PET scanner for small animals. The chip uses a SiGe Bi-CMOS process for timing measurements, integrating a fully-depleted pixel matrix with a low-power BJT-b…
▽ More
Time-of-flight measurement is an important advancement in PET scanners to improve image reconstruction with a lower delivered radiation dose. This article describes the monolithic ASIC for the TT-PET project, a novel idea for a high-precision PET scanner for small animals. The chip uses a SiGe Bi-CMOS process for timing measurements, integrating a fully-depleted pixel matrix with a low-power BJT-based front-end per channel, integrated on the same 100 $μ m$ thick die. The target timing resolution is 30 ps RMS for electrons from the conversion of 511 keV photons. A novel synchronization scheme using a patent-pending TDC is used to allow the synchronization of 1.6 million channels across almost 2000 different chips at picosecond-level. A full-featured demonstrator chip with a 3x10 matrix of 500x500 $μ m^{2}$ pixels was produced to validate each block. Its design and experimental results are presented here.
△ Less
Submitted 26 November, 2018;
originally announced November 2018.
-
A Letter of Intent for MATHUSLA: a dedicated displaced vertex detector above ATLAS or CMS
Authors:
Cristiano Alpigiani,
Austin Ball,
Liron Barak,
James Beacham,
Yan Benhammo,
Tingting Cao,
Paolo Camarri,
Roberto Cardarelli,
Mario Rodriguez-Cahuantzi,
John Paul Chou,
David Curtin,
Miriam Diamond,
Giuseppe Di Sciascio,
Marco Drewes,
Sarah C. Eno,
Erez Etzion,
Rouven Essig,
Jared Evans,
Oliver Fischer,
Stefano Giagu,
Brandon Gomes,
Andy Haas,
Yuekun Heng,
Giuseppe Iaselli,
Ken Johns
, et al. (39 additional authors not shown)
Abstract:
In this Letter of Intent (LOI) we propose the construction of MATHUSLA (MAssive Timing Hodoscope for Ultra-Stable neutraL pArticles), a dedicated large-volume displaced vertex detector for the HL-LHC on the surface above ATLAS or CMS. Such a detector, which can be built using existing technologies with a reasonable budget in time for the HL-LHC upgrade, could search for neutral long-lived particle…
▽ More
In this Letter of Intent (LOI) we propose the construction of MATHUSLA (MAssive Timing Hodoscope for Ultra-Stable neutraL pArticles), a dedicated large-volume displaced vertex detector for the HL-LHC on the surface above ATLAS or CMS. Such a detector, which can be built using existing technologies with a reasonable budget in time for the HL-LHC upgrade, could search for neutral long-lived particles (LLPs) with up to several orders of magnitude better sensitivity than ATLAS or CMS, while also acting as a cutting-edge cosmic ray telescope at CERN to explore many open questions in cosmic ray and astro-particle physics. We review the physics motivations for MATHUSLA and summarize its LLP reach for several different possible detector geometries, as well as outline the cosmic ray physics program. We present several updated background studies for MATHUSLA, which help inform a first detector-design concept utilizing modular construction with Resistive Plate Chambers (RPCs) as the primary tracking technology. We present first efficiency and reconstruction studies to verify the viability of this design concept, and we explore some aspects of its total cost. We end with a summary of recent progress made on the MATHUSLA test stand, a small-scale demonstrator experiment currently taking data at CERN Point 1, and finish with a short comment on future work.
△ Less
Submitted 2 November, 2018;
originally announced November 2018.
-
RPC performance vs FE electoronics and detector parameters
Authors:
R. Cardarelli,
G. Aielli,
E. Alunno Camelia,
S. Bruno,
A. Caltabiano,
P. Camarri,
A. Di Ciaccio,
B. Liberti,
L. Massa,
L. Pizzimento,
A. Rocchi
Abstract:
The first Resistive Plate Chambers detectors were developed for cosmic ray experiments, where low rate capability, good time resolution and low cost per unit of area were needed. These same features, except for the low rate capability, were required in the muon spectrometers of the collider experiments like LHC. For this purpose newRPCdetectors with increased rate capability were developed. The ra…
▽ More
The first Resistive Plate Chambers detectors were developed for cosmic ray experiments, where low rate capability, good time resolution and low cost per unit of area were needed. These same features, except for the low rate capability, were required in the muon spectrometers of the collider experiments like LHC. For this purpose newRPCdetectors with increased rate capability were developed. The rate capability improvement has been achieved thanks to the transition from streamer to saturated avalanche regime, in which the average charge produced in the gas dicharge is smaller. The price to pay for this working mode switch is the transfer of the amplification from the detector to the FE electorinics. The High luminosity LHC and the future colliders will require even greater rate capability in the muon spectrometer compared to the current one. For this reason, further improving of the rate capability is required. The transition from the saturated avalanche to a low saturated avalanche regime moves in this direction and needs a new front end electronics with better signal to noise ratio, because the average induced charge on the electrode is even smaller. The front end electronics design is crucial for the RPC performances. In this paper we discuss the performances of the RPC detector changing the front end design and the detector parameters.
△ Less
Submitted 27 September, 2018;
originally announced September 2018.
-
Development of gaseous particle detectors based on semiconductive plate electrodes
Authors:
A. Rocchi,
R. Cardarelli,
G. Aielli,
E. Alunno Camelia,
S. Bruno,
A. Caltabiano,
P. Camarri,
A. Di Ciaccio,
B. Liberti,
L. Massa,
L. Pizzimento
Abstract:
A new particle detector with sub-nanosecond time resolution capable of working in high-rate environment (rate capability of the order of $MHz/ cm^2$) is under developmnet. Semiconductive electrodes with resistivity $ρ$ up to $10^8 Ω\cdot cm$ have been used to improve the RPC [1] [2] rate capability. In this paper efficiency and time resolution of three different detector structures are presented.
A new particle detector with sub-nanosecond time resolution capable of working in high-rate environment (rate capability of the order of $MHz/ cm^2$) is under developmnet. Semiconductive electrodes with resistivity $ρ$ up to $10^8 Ω\cdot cm$ have been used to improve the RPC [1] [2] rate capability. In this paper efficiency and time resolution of three different detector structures are presented.
△ Less
Submitted 5 July, 2018;
originally announced July 2018.
-
Development of a new Front End electronics in Silicon and Silicon-Germanium technology for the Resistive Plate Chamber detector for high rate experiments
Authors:
Luca Pizzimento,
Roberto Cardarelli,
Giulio Aielli,
Elio Alunno Camelia,
Salvatore Bruno,
Alessandro Caltabiano,
Paolo Camarri,
Anna Di Ciaccio,
Barbara Liberti,
Lorenzo Massa,
Alessandro Rocchi
Abstract:
The upgrade of the Resistive Plate Chamber (RPC) detector, in order to increase the detector rate capability and to be able to work efficiently in high rate environment, consists in the reduction of the operating voltage along with the detection of signals which are few hundred μV small. The approach chosen by this project to achieve this objective is to develop a new kind of Front End electronics…
▽ More
The upgrade of the Resistive Plate Chamber (RPC) detector, in order to increase the detector rate capability and to be able to work efficiently in high rate environment, consists in the reduction of the operating voltage along with the detection of signals which are few hundred μV small. The approach chosen by this project to achieve this objective is to develop a new kind of Front End electronics which, thanks to a mixed technology in Silicon and Silicon-Germanium, enhance the detector performances increasing its rate capability. The Front End developed is composed by a preamplifier in Silicon BJT technology with a very low inner noise (1000 $e^{-}$ rms) and an amplification factor of 0.3-0.4 mV/fC and a new kind of discriminator in SiGe HJT technology which allows a minimum threshold of the order of 0.5 mV. The performances of this kind of Front End will be shown. The results are obtained by using the CERN H8 beamline with a full-size RPC chamber of 1 mm gas gap and 1.2 mm thickness of electrodes equipped with this kind of Front End electronics.
△ Less
Submitted 11 June, 2018;
originally announced June 2018.
-
Design a TDC in SiGe for RPC's electronics Front-end for the use in a high-rate experiment
Authors:
Salvatore Bruno,
Roberto Cardarelli,
Giulio Aielli,
davide Badoni,
Paolo Camarri,
Anna Di Ciaccio,
Eelio Alunno Camelia,
Alessandro Caltabiano,
Lorenzo Massa,
Lorenzo Paolozzi,
Luca Pizzimento,
Alessandro Rocchi
Abstract:
With the new generation of the RPC, it is possible to work with induced signals of hundreds $μV$, hence the front-end electronics is an important and delicate part of the detector in order to get a detectable signal. The electronic chain is made up of an amplifier, a discriminator, a TDC. The new front-end is realized with the use of silicon-germanium (SiGe) components, provided by IHP microelectr…
▽ More
With the new generation of the RPC, it is possible to work with induced signals of hundreds $μV$, hence the front-end electronics is an important and delicate part of the detector in order to get a detectable signal. The electronic chain is made up of an amplifier, a discriminator, a TDC. The new front-end is realized with the use of silicon-germanium (SiGe) components, provided by IHP microelectronics. With this technology we can implement BJT and CMOS transistors on the same chip. The benefit of this improvement is to minimize: power consumption of the channels ($2 ÷3$ $ \frac{mW}{ch}$), noise (500 $e^-$ r.m.s), radiation hardness (10 kGy,$10^3$ $\frac{n}{cm}$) and it maximizes the speed of response electronics. In this work I will highlight the first TDC prototypes' results. The TDC uses a local oscillator, that has an oscillation range between $0.6 ÷3 $ GHz, and a the temporal jitter of 15 ps. The data output from the TDC are presented in binary in order to lighten data processing to the acquisition system. Moreover, we are studying a way to minimize system latency. This optimization involves the addition of a serializer (PISO) that sends the TDC data output to the acquisition system at 2 GHz.
△ Less
Submitted 21 June, 2018; v1 submitted 11 June, 2018;
originally announced June 2018.
-
Optimization of RPCs read-out panel with electromagnetic simulation
Authors:
E. Alunno Camelia,
R. Cardarelli,
A. Di Ciaccio,
S. Bruno,
A. Caltabiano,
P. Camarri,
B. Liberti,
L. Massa,
L. Pizzimento,
A. Rocchi
Abstract:
With the upgrade of the RPCs [1]-[2] and the increase of its performances, the study and the optimization of the read-out panel is necessary in order to maintain the signal integrity and to reduce the intrinsic crosstalk. Through Electromagnetic Simulation, performed with CST Studio Suite, new panels design are tested and their crosstalk property are studied. The behavior of different type of pane…
▽ More
With the upgrade of the RPCs [1]-[2] and the increase of its performances, the study and the optimization of the read-out panel is necessary in order to maintain the signal integrity and to reduce the intrinsic crosstalk. Through Electromagnetic Simulation, performed with CST Studio Suite, new panels design are tested and their crosstalk property are studied. The behavior of different type of panel is shown, in particular a panel with the decoupling strip connected through their characteristic impedance to the ground plane is simulated.
△ Less
Submitted 11 June, 2018;
originally announced June 2018.
-
Test beam measurement of the first prototype of the fast silicon pixel monolithic detector for the TT-PET project
Authors:
L. Paolozzi,
Y. Bandi,
M. Benoit,
R. Cardarelli,
S. Débieux,
D. Forshaw,
D. Hayakawa,
G. Iacobucci,
M. Kaynak,
A. Miucci,
M. Nessi,
O. Ratib,
E. Ripiccini,
H. Rücker,
P. Valerio,
M. Weber
Abstract:
The TT-PET collaboration is developing a PET scanner for small animals with 30 ps time-of-flight resolution and sub-millimetre 3D detection granularity. The sensitive element of the scanner is a monolithic silicon pixel detector based on state-of-the-art SiGe BiCMOS technology. The first ASIC prototype for the TT-PET was produced and tested in the laboratory and with minimum ionizing particles. Th…
▽ More
The TT-PET collaboration is developing a PET scanner for small animals with 30 ps time-of-flight resolution and sub-millimetre 3D detection granularity. The sensitive element of the scanner is a monolithic silicon pixel detector based on state-of-the-art SiGe BiCMOS technology. The first ASIC prototype for the TT-PET was produced and tested in the laboratory and with minimum ionizing particles. The electronics exhibit an equivalent noise charge below 600 e- RMS and a pulse rise time of less than 2 ns, in accordance with the simulations. The pixels with a capacitance of 0.8 pF were measured to have a detection efficiency greater than 99% and, although in the absence of the post-processing, a time resolution of approximately 200 ps.
△ Less
Submitted 6 February, 2018; v1 submitted 5 February, 2018;
originally announced February 2018.
-
Improving the RPC rate capability
Authors:
G. Aielli,
P. Camarri,
R. Cardarelli,
A. Di Ciaccio,
L. Di Stante,
R. Iuppa,
B. Liberti,
L. Paolozzi,
E. Pastori,
R. Santonico,
M. Toppi
Abstract:
This paper has the purpose to study the rate capability of the Resistive Plate Chamber, RPC, starting from the basic physics of this detector. The effect of different working parameters determining the rate capability is analysed in detail, in order to optimize a new family of RPCs for applications to heavy irradiation environments and in particular to the LHC phase 2. A special emphasis is given…
▽ More
This paper has the purpose to study the rate capability of the Resistive Plate Chamber, RPC, starting from the basic physics of this detector. The effect of different working parameters determining the rate capability is analysed in detail, in order to optimize a new family of RPCs for applications to heavy irradiation environments and in particular to the LHC phase 2. A special emphasis is given to the improvement achievable by minimizing the avalanche charge delivered in the gas. The paper shows experimental results of Cosmic Ray tests, performed to study the avalanche features for different gas gap sizes, with particular attention to the overall delivered charge. For this purpose, the paper studies, in parallel to the prompt electronic signal, also the ionic signal which gives the main contribution to the delivered charge. Whenever possible the test results are interpreted on the base of the RPC detector physics and are intended to extend and reinforce our physical understanding of this detector.
△ Less
Submitted 10 June, 2016;
originally announced June 2016.
-
100ps time resolution with thin silicon pixel detectors and a SiGe HBT amplifier
Authors:
Mathieu Benoit,
Roberto Cardarelli,
Stéphane Débieux,
Yannick Favre,
Giuseppe Iacobucci,
Marzio Nessi,
Lorenzo Paolozzi,
Kenji Shu
Abstract:
A 100um thick silicon detector with 1mm2 pad readout optimized for sub-nanosecond time resolution has been developed and tested. Coupled to a purposely developed amplifier based on SiGe HBT technology, this detector was characterized at the H8 beam line at the CERN SPS. An excellent time resolution of (106+-1)ps for silicon detectors was measured with minimum ionizing particles.
A 100um thick silicon detector with 1mm2 pad readout optimized for sub-nanosecond time resolution has been developed and tested. Coupled to a purposely developed amplifier based on SiGe HBT technology, this detector was characterized at the H8 beam line at the CERN SPS. An excellent time resolution of (106+-1)ps for silicon detectors was measured with minimum ionizing particles.
△ Less
Submitted 13 November, 2015;
originally announced November 2015.
-
Response of diamond detector sandwich to 14 MeV neutrons
Authors:
M. Osipenko,
M. Ripani,
G. Ricco,
B. Caiffi,
F. Pompili,
M. Pillon,
G. Verona-Rinati,
R. Cardarelli
Abstract:
In this paper we present the measurement of the response of 50 $μ$m thin diamond detectors to 14 MeV neutrons. Such neutrons are produced in fusion reactors and are of particular interest for ITER neutron diagnostics. Among semiconductor detectors diamond has properties most appropriate for harsh radiation and temperature conditions of a fusion reactor. However, 300-500 $μ$m thick diamond detector…
▽ More
In this paper we present the measurement of the response of 50 $μ$m thin diamond detectors to 14 MeV neutrons. Such neutrons are produced in fusion reactors and are of particular interest for ITER neutron diagnostics. Among semiconductor detectors diamond has properties most appropriate for harsh radiation and temperature conditions of a fusion reactor. However, 300-500 $μ$m thick diamond detectors suffer significant radiation damage already at neutron fluences of the order of $10^{14}$ n/cm$^2$. It is expected that a 50 $μ$m thick diamond will withstand a fluence of $>10^{16}$ n/cm$^2$. We tested two 50 $μ$m thick single crystal CVD diamonds, stacked to form a "sandwich" detector for coincidence measurements. The detector measured the conversion of 14 MeV neutrons, impinging on one diamond, into $α$ particles which were detected in the second diamond in coincidence with nuclear recoil. For $^{12}C(n,α)^{9}Be$ reaction the total energy deposited in the detector gives access to the initial neutron energy value. The measured 14 MeV neutron detection sensitivity through this reaction by a detector of effective area 3$\times$3 mm$^2$ was $5\times 10^{-7}$ counts cm$^2$/n. This value is in good agreement with Geant4 simulations. The intrinsic energy resolution of the detector was found to be 240 keV FWHM which adds only 10 % to ITER's 14 MeV neutron energy spread.
△ Less
Submitted 2 November, 2015; v1 submitted 19 October, 2015;
originally announced October 2015.
-
Neutron spectrometer for fast nuclear reactors
Authors:
M. Osipenko,
M. Ripani,
G. Ricco,
B. Caiffi,
F. Pompili,
M. Pillon,
M. Angelone,
G. Verona-Rinati,
R. Cardarelli,
G. Mila,
S. Argiro
Abstract:
In this paper we describe the development and first tests of a neutron spectrometer designed for high flux environments, such as the ones found in fast nuclear reactors. The spectrometer is based on the conversion of neutrons impinging on $^6$Li into $α$ and $t$ whose total energy comprises the initial neutron energy and the reaction $Q$-value. The $^6$LiF layer is sandwiched between two CVD diamo…
▽ More
In this paper we describe the development and first tests of a neutron spectrometer designed for high flux environments, such as the ones found in fast nuclear reactors. The spectrometer is based on the conversion of neutrons impinging on $^6$Li into $α$ and $t$ whose total energy comprises the initial neutron energy and the reaction $Q$-value. The $^6$LiF layer is sandwiched between two CVD diamond detectors, which measure the two reaction products in coincidence. The spectrometer was calibrated at two neutron energies in well known thermal and 3 MeV neutron fluxes. The measured neutron detection efficiency varies from 4.2$\times 10^{-4}$ to 3.5$\times 10^{-8}$ for thermal and 3 MeV neutrons, respectively. These values are in agreement with Geant4 simulations and close to simple estimates based on the knowledge of the $^6$Li(n,$α$)$t$ cross section. The energy resolution of the spectrometer was found to be better than 100 keV when using 5 m cables between the detector and the preamplifiers.
△ Less
Submitted 25 May, 2015;
originally announced May 2015.
-
Test of a prototype neutron spectrometer based on diamond detectors in a fast reactor
Authors:
M. Osipenko,
F. Pompili,
M. Ripani,
M. Pillon,
G. Ricco,
B. Caiffi,
R. Cardarelli,
G. Verona-Rinati,
S. Argiro
Abstract:
A prototype of neutron spectrometer based on diamond detectors has been developed. This prototype consists of a $^6$Li neutron converter sandwiched between two CVD diamond crystals. The radiation hardness of the diamond crystals makes it suitable for applications in low power research reactors, while a low sensitivity to gamma rays and low leakage current of the detector permit to reach good energ…
▽ More
A prototype of neutron spectrometer based on diamond detectors has been developed. This prototype consists of a $^6$Li neutron converter sandwiched between two CVD diamond crystals. The radiation hardness of the diamond crystals makes it suitable for applications in low power research reactors, while a low sensitivity to gamma rays and low leakage current of the detector permit to reach good energy resolution. A fast coincidence between two crystals is used to reject background. The detector was read out using two different electronic chains connected to it by a few meters of cable. The first chain was based on conventional charge-sensitive amplifiers, the other used a custom fast charge amplifier developed for this purpose. The prototype has been tested at various neutron sources and showed its practicability. In particular, the detector was calibrated in a TRIGA thermal reactor (LENA laboratory, University of Pavia) with neutron fluxes of $10^8$ n/cm$^2$s and at the 3 MeV D-D monochromatic neutron source named FNG (ENEA, Rome) with neutron fluxes of $10^6$ n/cm$^2$s. The neutron spectrum measurement was performed at the TAPIRO fast research reactor (ENEA, Casaccia) with fluxes of 10$^9$ n/cm$^2$s. The obtained spectra were compared to Monte Carlo simulations, modeling detector response with MCNP and Geant4.
△ Less
Submitted 23 May, 2015;
originally announced May 2015.
-
SuperB Technical Design Report
Authors:
SuperB Collaboration,
M. Baszczyk,
P. Dorosz,
J. Kolodziej,
W. Kucewicz,
M. Sapor,
A. Jeremie,
E. Grauges Pous,
G. E. Bruno,
G. De Robertis,
D. Diacono,
G. Donvito,
P. Fusco,
F. Gargano,
F. Giordano,
F. Loddo,
F. Loparco,
G. P. Maggi,
V. Manzari,
M. N. Mazziotta,
E. Nappi,
A. Palano,
B. Santeramo,
I. Sgura,
L. Silvestris
, et al. (384 additional authors not shown)
Abstract:
In this Technical Design Report (TDR) we describe the SuperB detector that was to be installed on the SuperB e+e- high luminosity collider. The SuperB asymmetric collider, which was to be constructed on the Tor Vergata campus near the INFN Frascati National Laboratory, was designed to operate both at the Upsilon(4S) center-of-mass energy with a luminosity of 10^{36} cm^{-2}s^{-1} and at the tau/ch…
▽ More
In this Technical Design Report (TDR) we describe the SuperB detector that was to be installed on the SuperB e+e- high luminosity collider. The SuperB asymmetric collider, which was to be constructed on the Tor Vergata campus near the INFN Frascati National Laboratory, was designed to operate both at the Upsilon(4S) center-of-mass energy with a luminosity of 10^{36} cm^{-2}s^{-1} and at the tau/charm production threshold with a luminosity of 10^{35} cm^{-2}s^{-1}. This high luminosity, producing a data sample about a factor 100 larger than present B Factories, would allow investigation of new physics effects in rare decays, CP Violation and Lepton Flavour Violation. This document details the detector design presented in the Conceptual Design Report (CDR) in 2007. The R&D and engineering studies performed to arrive at the full detector design are described, and an updated cost estimate is presented.
A combination of a more realistic cost estimates and the unavailability of funds due of the global economic climate led to a formal cancelation of the project on Nov 27, 2012.
△ Less
Submitted 24 June, 2013;
originally announced June 2013.
-
Studies on fast triggering and high precision tracking with Resistive Plate Chambers
Authors:
G. Aielli,
B. Bilki,
R. Ball,
J. W. Chapman,
R. Cardarelli,
T. Dai,
E. Diehl,
J. Dubbert,
C. Ferretti,
H. Feng,
K. Francis,
L. Guan,
L. Han,
S. Hou,
D. Levin,
B. Li,
L. Liu,
L. Paolozzi,
J. Repond,
J. Roloff,
R. Santonico,
H. Y. Song,
X. L. Wang,
Y. Wu,
L. Xia
, et al. (5 additional authors not shown)
Abstract:
We report on studies of fast triggering and high-precision tracking using Resistive Plate Chambers (RPCs). Two beam tests were carried out with the 180 GeV muon beam at CERN using RPCs with gas gaps of 1.00 or 1.15 mm and equipped with readout strips with 1.27 mm pitch. This is the first beam test of RPCs with fine-pitch readout strips that explores simultaneously precision tracking and triggering…
▽ More
We report on studies of fast triggering and high-precision tracking using Resistive Plate Chambers (RPCs). Two beam tests were carried out with the 180 GeV muon beam at CERN using RPCs with gas gaps of 1.00 or 1.15 mm and equipped with readout strips with 1.27 mm pitch. This is the first beam test of RPCs with fine-pitch readout strips that explores simultaneously precision tracking and triggering capabilities. RPC signals were acquired with precision timing and charge integrating readout electronics at both ends of the strips. The time resolution was measured to be better than 600 ps and the average spatial resolution was found to be 220 um using charge information and 287 um using timing information. The dual-ended readout allows the determination of the average and the difference of the signal arrival times. The average time was found to be independent of the incident particle position along the strip and is useful for triggering purposes. The time difference yielded a determination of the hit position with a precision of 7.5 mm along the strip. These results demonstrate the feasibility using RPCs for fast and high-resolution triggering and tracking.
△ Less
Submitted 24 October, 2012;
originally announced October 2012.
-
Ageing test of the ATLAS RPCs at X5-GIF
Authors:
G. Aielli,
M. Alviggi,
V. Ammosov,
M. Biglietti,
P. Camarri,
V. Canale,
M. Caprio,
R. Cardarelli,
G. Carlino,
G. Cataldi,
G. Chiodini,
F. Conventi,
R. de Asmundis,
M. Della Pietra,
D. Della Volpe,
A. Di Ciaccio,
A. Di Simone,
L. Di Stante,
E. Gorini,
F. Grancagnolo,
P. Iengo,
B. Liberti,
A. Nisati,
Fr. Pastore,
E. Pastori
, et al. (10 additional authors not shown)
Abstract:
An ageing test of three ATLAS production RPC stations is in course at X5-GIF, the CERN irradiation facility. The chamber efficiencies are monitored using cosmic rays triggered by a scintillator hodoscope. Higher statistics measurements are made when the X5 muon beam is available. We report here the measurements of the efficiency versus operating voltage at different source intensities, up to a m…
▽ More
An ageing test of three ATLAS production RPC stations is in course at X5-GIF, the CERN irradiation facility. The chamber efficiencies are monitored using cosmic rays triggered by a scintillator hodoscope. Higher statistics measurements are made when the X5 muon beam is available. We report here the measurements of the efficiency versus operating voltage at different source intensities, up to a maximum counting rate of about 700Hz/cm^2. We describe the performance of the chambers during the test up to an overall ageing of 4 ATLAS equivalent years corresponding to an integrated charge of 0.12C/cm^2, including a safety factor of 5.
△ Less
Submitted 28 October, 2004; v1 submitted 27 October, 2004;
originally announced October 2004.